Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.0 L+₹2.3 L (14.2%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹21.9 L+₹5.3 L (31.9%)Rejected-Finance | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹27.0 L+₹10.4 L (62.5%)Rejected-Finance | L4 | Rejected-Finance Being Higher Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 May 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/REPLACEMENT AND MAINT OF WINDOW TYPE AC, SPLIT TYPE AC, TOWER AC, CASSETTE TYPE AC INCLUDING MISC SUMMER APPLIANCES IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW
2022_MES_519031_1
GE/EM/LKO/EXT(WS)/T-05 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
240 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹50,000
Yes
4 Jun 2022
20 Apr 2022
18 May 2022
20 Apr 2022
16 May 2022
4 May 2022
Amount
Disconnecting ACs and Voltage stabilizers and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE complete all as specified and directed. (Note :- Spare parts shall be measured and paid separately under appropriate items)
M&L for rewal running capacitor of capacity 45+4 Mfd in plastic container complete all as specified and directed. Make- Epcos/Seacon/Godrej
M&L for rewal running capacitor of capacity 36 Mfd in plastic container complete all as specified and directed. Make- Epcos/Seacon/Godrej
Supply and replacement of running capacitor of capacity 50+5Mfd in plastic container complete all as specified and directed. Make- Epcos/Seacon/Godrej
Supply and replacement of Air Censor for temperature control for 1.5 TR / 2 TR compressor complete all as specified and directed.
S&F in repairs Swing motor for 1.5 TR / 2 TR indoor unit (Cooling/Hot&Cold/Inverter) of split type air conditioner of Make :- LG/Carrier/Voltas/Hitachi/Daikin/Bluestar) complete all as specified and directed.
S&F in repairs Swing motor suitable for 1.5 TR / 2 TR window AC (Cooling/Hot&Cold/Inverter) complete all as specified and directed. Make :- LG/Carrier/Voltas/Hitachi/Daikin/Bluestar)
S&F ( in repairs) suction copper pipe line heavy duty ½” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed.
S&F ( in repairs) suction copper pipe line heavy duty 1/4” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed.
S&F( in reapirs) discharge copper pipe line heavy duty 3/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed.
S & F( in repairs) PVC insulated three core stranded FRLS copper cable of size 80/0.20 ( 2.5 sqmm) complete all as specified and directed.
S & F ( in repairs) copper Gas filter for AC 1.5 TR / 2 TR capacity complete all as specified and directed.
Taking out defective blower motor from window type AC of cap 1.5/2.0 TR or outdoor unit of Split type AC of capacity 1.5 TR / 2 TR of any make & capacity including dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
S & F( in repairs) PVC pipe nylon imbraided 15 mm dia for condensed water drain fitted with clamps/concealed in wall complete all as specified and directed.
Dismantling of existing window type AC. from its location and refixing after doing the following repairs wherever required and as directed by EIC. (a) Servicing & cleaning with liquid soap , cleaning of fins by means of air blower and water with pressure jet and changing of air filter complete with cleaning of Cooling & Condensing coil all as directed by EIC. (b) M&L for painting of outer cage and front grill window type A/C with two coats of synthetic enameled paint of approved shade and tint including preparation of steel surface by emery paper including writing SM No. / MES No. etc with front of grill complete all as directed by EIC
Taking down old plywood and S&F plywood 6 mm thick,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished complete all as specified and directed.
Renewal of 2nd class HW (SAL) fillets, cross sectional area excd 3 and not excd 6 sqcm on all four sides of window type AC splayed or chamfered edge including polishing etc complete all as specified and directed.
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply and fixing new indoor unit(Hot &Cold) of the same capacity in working condition with blower motor, front grill and all other connected items and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted complete all as specified and directed. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective outdoor unit of 1.5 TR capacity split type AC and supply and fixing new outdoor unit(Hot&Cold) of the same capacity in working condition with blower motor,fan, and condensing unit of copper, and cabinet and all other connected electricals and items for connecting with indoor unit and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with refrigerant gas as required with stand and installing the unit in wall/ceiling mounted complete all as specified and directed. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit ( except compressor) complete with condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade complete all as specified and directed. ( Make :- Totaline/ Bluestar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 2 TR capacity and supply & fixing new condensing unit ( except compressor) complete with condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade complete all as specified and directed. ( Make :- Totaline/ Bluestar/LG/Voltas/Daikin/Hitachi)
S & F ( in repairs) MCB SP -6 to 32 Amps rating to be housed in DBs catered here in after complete all as specified and directed Make-Indoasian/Schneider/C&S
S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified and directed. Make-Indoasian/Schneider/C&S
S&F in repairs Mettalic Plugs ( top) of AC box 20A, existing make, 2P+E and connecting complete all as specified and directed.
Dismantling of defective cooling coil of 1.5 TR window type/Split type AC of any make and S&F new cooling coil for AC, detecting the leakage with N2 Gas, reconnecting in to the system complete all as specified and directed.
All as per item No 25 above but for 2.0 TR Split AC/Window AC
Dismantling of defective condensing coil of 1.5 TR window type AC of any make and S&F new cooling coil for AC, detecting the leakage with N2 Gas, reconnecting in to the system complete all as specified and directed.
All as per item No 27 above but for 2.0 TR Split AC
Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC(Hot&Cold/Cooling type/Inverter) (indoor unit) and supply & fixing new blower motor Suitable for Carrier/Voltas/Blue star/LG/Samsung/Daikin/Hitachi) Make ACs as per sample complete all as specified and directed.
Dismantling of burnt outdoor fan motor of 1.5 TR/2.0TR split AC (Hot&Cold/Cooling type/Inverter) (outdoor unit) and supply & fixing new outdoor fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung/Daikin/Hitachi Make ACs as per sample complete all as specified and directed.
Dismantling of burnt fan motor of 1.5 TR/2.0TR window AC double shaft and supply & fixing new fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed.
Dismantling of unserviceable compressors of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and directed. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson/ Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 2 TR capacities including disconnecting suction / discharge copper tubing and S&F compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and directed. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 1.5 TR capacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and directed. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 2 TR capacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as specified and directed. Note :_ (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Servicing of IDU (Indoor unit) of ceiling mounted casset type split Air conditioner of 3 TR capacity comprising of Blower, blower motor ,water lifting motor, , & greasing of moving parts complete all as specified and directed.
Servicing of IDU (Indoor unit) of ceiling mounted casset type split Air conditioner of 4 TR capacity comprising of Blower, blower motor ,water lifting motor, , & greasing of moving parts complete all as specified and directed.
Servicing of condensing unit comprising of condensing coil, condensing fan and tubing by cleaning condensing coil tighting nuts, bolts, screw and other petty repairs ceiling suspended split AC of capacity 3 TR complete all as specified and directed.
Servicing of condensing unit comprising of condensing coil, condensing fan and tubing by cleaning condensing coil tighting nuts, bolts, screw and other petty repairs ceiling suspended split AC of capacity 4 TR complete all as specified and directed.
Renewal of remote hand set of window type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar)
Renewal of remote hand set of Split type air conditioner (Hot&Cold/Cooling/Inverter type) of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed.
S&F in repairs brass suction valve size 3/8" complete all as specified and directed
S&F in repairs Discharge valve size 1/2" complete all as specified and directed .
S&F ( in repairs) charging valve 1/4" dia for carrier make split AC complete all as specified and directed.
S&F in repairs flare nuts size 3/8" complete all as specified and directed
S&F in repairs flare nuts size 1/4"complete all as specified and directed
S&F in repairs flare nuts size 1/2" complete all as specified and directed
S&F in repairs ML-1 contactor 240 volt, 25 Amp for split type AC complete all as specified and directed. Make- Annapurna/L&T
S&F in repairs copper capillary of size 0.55 mm complete all as specified and directed.
S&F ( in repairs) Aluminium fan blade with gun metal bush of blower , Screw complete as per complete all as specified and directed.
S&F Aluminium runner for window A.C. as per sample complete all as specified and directed
Supply and fixing ( in repairs) PVC knob of window type AC complete all as specified and directed (Make LG / Carrier/Voltas)
Supply and fixing in repairs front grill of superior quality for window AC of 1.5 TR/ 2 TR of Make National/ Casmo/LG/Carrier / Blue Star/Samsung/Videocon complete all as specified and directed.
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR including unserviceable electronic remote control, supply and fixing new control wiring and electronic remote control to suit / match the existing system complete all as specified and directed. (Make of AC and remote:- ITC / Carrier / Cool Air/LG/Voltas/Hitachi/Daikin)
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and directed. (Make of AC and remote:- ITC / Carrier / Cool Air/LG/Voltas/Hitachi/Daikin)
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR ( heating and cooling type) including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and directed. (Make of AC and remote:-Carrier / LG- HI- SERIES)
Dismantling of defective worn out wiring of window AC/Split ac of capacity 1.5 TR / 2 /3 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and directed. (Make of AC and remote:-Carrier / LG- HI- SERIES).
Dismantling of defective worn out wiring of CASSETE Type AC of capacity 3 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control and sensor supply and fixingNEW PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and directed. (Make of AC and remote:-Carrier / LG- HI- SERIES).
Dismantling of defective worn out wiring of CASSETE Type AC of capacity 4 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control, supply and fixingNEW PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system complete all as specified and directed. (Make of AC and remote:-Carrier / LG- HI- SERIES).
S&F in replacement with New Water pump for CASSETE Type AC of capacity 3 TR/4TR including Floate valve and connected items complete all as specified and directed. Make-LG/Carrier/Bluestar
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC of any make &(cooling only/hot& cold type) from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
All as per item 61 above but for 1.5/2.0 TR WINDOW AC OF any make.
All as per item 61 above but for 3.0/4.0 TR cassette type AC OF any make.
Dismantling carefully front cover of indoor unit split type AC of any make & model of capacity 1.5 / 2 TR and disconnecting the water drain pipe for cleaning sludge etc refixing the water drain pipe at its original position of indoor unit including provision of necessary accessories for fixing of drain pipe and testing complete for proper functioning of indoor unit and refixing of front cover complete all as specified and directed.
M & L for servicing of Indoor unit and outdoor unit by means of electric blower & water under pressure ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,, & greasing of moving parts such as blower motor etc complete of 1.5 TR capacity complete all as specified and directed.
M & L for servicing of Indoor unit and outdoor unit by means of electric blower & water under pressure ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,, & greasing of moving parts such as blower motor etc complete of 2 TR complete all as specified and directed.
M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22/R-32/R-410 into the system for 1.5 TR capacity split type AC complete all as specified and directed. (The refrigerant gas R-22 will be provided by Contractor)
All as per item No 67 above but for 2.0 TR Split AC
All as per item No 67 above but for window type AC of capacity 1.5/2.0 TR
Supply & (Charging /Top up) the AC unit of 1.5 TR / 2 TR split type AC/Window AC unit with refrigerant gas R-22/R-32/R-410 in required Qty complete all as specified and directed
S&F ( in repairs) PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 3 core 6sqmm complete all as specified and directed. Make-Havelles/Grandlay/RR cable/Finolex
Taking down unserviceable voltage stabilizers of any make of following capacities and dismantling the stablizer of any size for repairs of the defective parts/ spares & reassembling including repairs of defective screws, rubber shoes, testing complete all as specified and directed. (Note: Spares parts measured and paid seprately
S&F Relay 25/30 Amps 24 Volt for 4 KVA/ 5 KVA voltage stablizers complete all as specified and directed. Make- Dunmag,Eaglemen,Powerman
S&F Relay 6Amps 18 Volt for 0.5KVA voltage stablizers complete all as specified and directed. Make- Dunmag,Eaglemen,Powerman
Supply and fixing ( in repairs) Main PCB with high & low voltage cut off suiable for 4 KVA/ 5 KVA voltage stablizers of any make complete all as specified and directed. ( Make:- Blue birds/ Hitech)
Supply and fixing ( in repairs) Main PCB with high & low voltage cut off suiable for 0.5 KVA voltage stablizers of any make complete all as specified and directed. ( Make:- Blue birds/ Hitech) .
S&F ( in repairs) 2 Metre long copper conductor cable 3 core PVC insulated and sheathed 80 / 0.20 ( 2.5 sqmm)size duly fitted with 3 pin top, 20 Amps ( Cat No. 38637 of Anchor or any equivalent specified make complete all as specified and directed.
S&F ( in repairs) 2 Metre long copper conductor cable 3 core PVC insulated and sheathed 24 / 0.20 ( 2.5 sqmm)size duly fitted with 3 pin top, 20 Amps ( Cat No. 38637 of Anchor or any equivalent specified make complete all as specified and directed.
S&F (in repairs ) power transformer suitable for Voltage stablizers of capacity 4/5 KVA of make Blue Bird / Vinitec / Servel suitable for following capacity stabilizer duly winded with suitable size super enamelled copper wire and testing complete all as specified and directed.
All as per item No 80 above but 0.5 KVA
S&F in replacement with AC volt meter, square/round type, 0-300 volts suitable for 8 KVA / 4 KVA / 5 KVA / 0.5 KVA single phase voltage stablizer complete all as specified and directed.
S&F (in repairs ) trigger transformer suitable for 4/5 KVA Voltage stabilizer of make Blue Bird / Vinitec / Servel duly winded with suitable size super enamelled copper wire and testing complete all as specified and directed.
Supply only connector for in - out supply of voltage stablizer, 15 Amp with earth connection complete all as specified and directed.
S&F(in repairs) socket outlet, 6 pin , 20 Amp, 240 volts, complete all as specified and directed.
S&F piano switch flash, 6 Amp, 240 volts single pole, one way, complete all as specified and directed.
S&F(in repairs) SP , push switch, 6 Amp, 240 volts single pole, complete all as specified and directed.
S&F in replacement voltage stabilizer of capacity 4KVA working range 150 to 285 volt AC With time delay system( 3 minute+/- 20 sec ITDS) wall mount 12 Amp suitable for AC up to 1.5TR or 18000 BTU/Hour capacity, complete all as specified and directed.
S&F in replacement New PCB for indoor unit of (Make-Samsung/LG/Voltas/Daikin/Hitachi/Carrier) of Cap 1.5/2.0 TR Split AC Inverter type( hot & cold) complete all as specified and directed.
S&F in replacement New PCB for Outdoor unit (Make-Samsung/LG/Voltas/Daikin/Hitachi/Carrier) of Cap 1.5/2.0 TR Split AC Inverter type( hot & cold) complete all as specified and directed.
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC inverter type of any make &(hot& cold type) from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .