Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹52.1 L+₹2.2 L (4.48%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹54.7 L+₹4.8 L (9.69%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹55.5 L+₹5.7 L (11.3%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹54.5 L+₹4.7 L (9.39%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
16 Jul 2024, 6:00 pmClosed
GE (AF) CHABUA
Office of GE (AF) CHABUA, Pin-786102
As per BOQ
2024_MES_661068_1
577/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF) CHABUA
As per tender document
8 documents required · 8 mandatory
₹500
GE(AF) CHABUA
₹99,800
Yes
12 Sept 2024
21 Jun 2024
18 Jul 2024
21 Jun 2024
16 Jul 2024
9 Jul 2024
Amount
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc . Removing materials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces of walls, floors etc.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site.
M&L for point wiring with 2.5 Sq mm single core PVC insulated FRLSH unsheathed copper multi stranded conductor in and including PVC casing capping of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc including sunk Anodized pressed steel box 1.6 mm thick concealed in wall with white laminated colour 3 mm thick sheet cover of suitable size complete including PVC insulated multi stranded copper conductor 2.5 Sq mm as earth wire to common earth dolly for connection to ceiling rose to earth terminal incl cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan/bell point controlled by one one way switch complete all as specified and directed at site.
All as per ser item No. 4 here-in-before but one 3 pin socket out let 5 Amps on the same board
All as per ser item No. 4 here-in-before but point wiring with 2.5 sqmm for one 3 pin socket out let 5 Amps on the Independent board
All as per Srl items No.4 here-in-before but point wiring with 2.5 Sqmm for 15 Amp socket out let with 2.5 sqmm earth continuity wire.
All as per Srl items No.4 here-in-before but point wiring with 4 Sqmm for Heater or lectric equipment/ AC 1.5 / 2 Ton / more than or equal to 3 KW load with 4.0 sqmm earth continuity wire.
All as per item No.4 above but for one light point controlled by two way switch with 1.5 sqmm copper wire
All as per item No. 4 above but for one bell/ buzzer point with 1.5 sqmm copper wire controlled by one push button on the independent board
S&F in repair switch Piano type two way 5 amp 230 volts complete all as specified and as directed.
S&F in repair switch bell push flush type 5 amp 230 volts complete all as specified and as directed.
S&F in repair Switch Piano flush type single pole one way 5 amp 230 v complete all as specified and directed at site.
S&F in repair socket outlet 2 in 1 , 5 pin, 5 amp complete all as specified and directed at site.
S&F in repair Switch Piano flush type single pole one way 15 amp 230 v complete all as specified and directed at site.
S&F in repair socket outlet 2 in 1 , 6 pin,5 and 15 amp complete all as specified and directed at site.
S&F in repair ceiling rose surface type Bakelite 65x50 mm three terminals complete all as specified and directed at site.
S&F in repair stepped type electronic fan regulator flushType complete all as specified and directed at site.
S&F in repair lamp holder , PVC /Polycarbonate type with back plate suitabl for batten fittings.
S&F in repair Modular switch , one way, 10 ams, 1 module 230 v complete all as specified and directed at site.
S&F in repair Modular switch , one way, 16 ams, 1 module 230 v complete all as specified and directed at site.
S&F in repair socket outlet,modular type ,multipurpose,multipin, 6/10 amps,1 module, 230 v complete as per direction by engr in charge
S&F in repair socket outlet,modular type ,multipurpose,multipin, 6/10/16/20 amps ,two module, 230 v complete as per direction by engr in charge.
S&F in repair modular type fan regulator,two module, 230 v complete all as specified and directed at site.
S&F in repair modular bell push 6 Amps 230 volts complete all as specified and as directed.
S&F in repair call bell Ding-Dong AC, 230 volts single pole complete all as specified and as directed.
S&F in repair surface and wall mounted LED batten fitting energy efficient fittings 20 watt complete , inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100Volts grade all as specified and directed.
S & F in repair surface and wall mounted LED batten fitting energy efficient fittings 10 watt complete , inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100Volts grade all as specified and directed.
Supply and fix LED Lamps 12 w B 22 base 3 star rating suitable for batten holder
S&F Blanking Plates for covering of MCCB DB open space complete all as specified and directed at site.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed at site
S&F in repair for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through & including PVC casing-caping medium grade complete all as specified and as directed.
All as per ser item No 32 here-in-before but 2x 4 sqmm for Phase and Neutral and 1x 4 sqmm for earth wire
S&F in repair MCB DB TPN 4 way with metal door suitable for Provision of incomer MCB and outgoing MCB's complete all as specified and as directed.
S&F in repair MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
S&F in repair MCB DB SPN 4 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
S&F in repair MCB SPN 240 volt 32 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F in repair MCB SPN 240 volt 40 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F in repair MCB FP 240 volt 63 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F in repair MCB SP 240 volt 6 to 32 Amps 'C' Series 10 KA complete all as specified and directed at site.
Supply and fix in repair factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket of 20 amps capacity complete all as specified and directed at site.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed at site.Make : Havells Ambrose /USHA Energia/CROMPTON ENERGION HS Note : Old unsv ceiling fan will be deposited to MES store yard
Supply and fix exhaust fan, steel body AC Single Phase, 230 V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed at site. Note : Old unsv exhaust fan will be deposited to MES store yard. Make : Havells Terbo Force/Crompton EXHD /Usha Terbo HD
S&F in repair switch socket combination 5/6 Amps 230/240 V complete all as specified and as directed.
S&F in repair switch socket combination 3 pin combination, 15/16 Amps 230/240 V complete all as specified and as directed.
S&F in repair Capacitor 2.5 mfd epoxy filled type copper wound complete all as specified and directed at site. Make : Havells/Epsco or equivalent make in MES
S&F in repair Capacitor 3.15 mfd epoxy filled type copper wound complete all as specified and directed at site. Make : Havells/Epsco or equivalent make in MES
S&F in repair PVC rectangular block for mounting of switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep. Make : Anchor/Presto or equivalentt make approved in MES
S&F in repair PVC rectangular block for mounting of switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep.Make : Anchor/Presto or equivalentt make approved in MES
Supply and fix in repair electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 ltr,BEE 5 star rated complete with all accessories such as safety valve,thermostate,NRV,connection pipe etc complete all as specified and directed at site. Note : Old unsv water heater will be deposited to MES store yard
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed at site. Make/Model : Havells ( Model 250 mm Fan ventil Air DX White)/Crompton ( Brisk Air_White)/Usha ( Crisp Air VX )
Supply and fixin repair PVC heavy duty hot and cold water pipe 450 mm long fixed both side with brass ferrule nuts for 25 ltr capacity geysers for inlet/outlet pipe complete all as specified and directed at site.
S&F in repairs heating element 2 KW,AC 230 volts (Cup/Triangular type) complete all as specified and directed at site.
S&F in repair thermostate switch suitable for 25 ltr geyser all as specified and directed at site.
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x 6 mm buried directly in ground verticvally to depth not less than 2.25 mtr below ground level and with top edge of the plate at a depth not less than 1.5 mtr below ground level, size of dipth 0.90 x 0.9 x 2.25 mtr ,earth plate connected to galvanised earth wire of size 4.00 mm dia 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth lead protection pipe light gade GI of size 15 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing lead with Main switch/main control board,filling with charcoal dust 200 Kg, and common salt 100 KG , including necessary excavation and earth work in any type of soil ,perforated watering pipe of 20 mm light grade,funnel with wire mesh,PCC chamber 1:3:6 type C1 of size 400mm x400 mm x400mm(for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by Engr-in-Charge
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep for taking out/ laying of pipe and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread any type of soil complete all as specified and directed by Engr-in-Charge.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Taking up or down old GI/MS/CI/DI/PPR tubing of 80/90 mm bore dia and connections including cleaning for refixng (serviceable) or removal to store complete all as specified and directed. (Excavation and earthwork measured and paid separately).
All as per ser item No 59 here-in- before above but bore of Pipe 50/63 mm dia pipe
All as per ser item No 59 here-in- before above but bore of Pipe 40 mm dia pipe
All as per ser item No 59 here-in- before above but bore of Pipe 32/25 mm dia pipe
Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-16) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 90 mm including all fittings complete all as specified.
All as per ser item No 63 here-in-before but size of PPR Pipe 63 mm
All as per ser item No 63 here-in-before but size of PPR Pipe 50 mm
All as per ser item No 63 here-in-before but size of PPR Pipe 40 mm
All as per ser item No 63 here-in-before but size of PPR Pipe 32 mm
All as per ser item No 63 here-in-before but size of PPR Pipe 25 mm
M&L for 50 mm bore gate valve cast bronze alloy screwed down high pressure with clutch handle screwed both ends for iron pipe including taking out of old gate valve complete all as specified and directed.
All as per ser item No 69 here-in- before above but size 25 mm bore
Supply & fixed in repairs PP-R Gate valves (brass insert) 63 mm outer dia of pipe complete all as specified and directed.
All as per ser item No 71 here-in-before but size of PPR gate valve 50 mm
All as per ser item No 71 here-in-before but size of PPR gate valve 40 mm
All as per ser item No 71 here-in-before but size of PPR gate valve 32 mm
All as per ser item No 71 here-in-before but size of PPR gate valve 25 mm
M&L for cutting of all burned winding of motor upto 7.5-10 HP, cleaning of all parts and rewinding with new super enameled winding wire copper of suitable /existing gauge including all insulating materials such as PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and applying insulating varnish and heating in heat chamber at appropriate temperature complete all as directed.
Supply and fixing in repair fully automatic star delta starter for submersible pump set of rating upto 10 HP, 415 volts, 50 Hz having with sheet metal encloser and relay range 3 phase, 15 to 23 Amps rating alongwith single phase preventer, contactor, panel mounting type complete all as specified.
M&L for run lead joint for CI pipes or specials suitable for 100 mm bore pipes incl spun yarn or any other consumable required at site including cleaning of old complete all as specified and directed.
All as per ser item No 78 here-in- before but size of pipe 80 pipe mm bore
Material & labour for repairing of 80 mm dia sluice valve by opening for rectifying leakage, refacing, regrinding, replacement of galand packing, gasket, nut, bolt, washer, wheel and refixing in its original position after testing comeplete all as specified and directed.
Material & labour for repairing of 100 mm dia sluice valve by opening for rectifying leakage, refacing, regrinding, replacement of galand packing, gasket, nut, bolt, washer, wheel and refixing in its original position after testing comeplete all as specified and directed.
Material and labour for repairing of leakage of GI tube size from 20 mm bore to 25 mm bore dia at any location and any position by cutting /threading /jointing and including earth work etc incl GI fittings such as tee /socket/ elbow/reducer /nipple or as site requirement complete all as specified and directed.
Material and labour for repairing of leakage of GI tube size from 32 mm bore to 50 mm bore dia at any location and any position by cutting /threading /jointing and including earth work etc incl GI fittings such as tee /socket/ elbow/reducer /nipple or as site requirement complete all as specified and directed.
Material and labour for construction of valve pit chamber of internal dimension 90 x 90 x 90 cm with sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8), type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 5 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/ loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete including dismantling of old all as specified and and directed.
All as per ser item No 84 here-in-before but of size of valve chamber 60 x 60 x 60 cm complete all as specified and directed at site
Supply only Calcium Hypo Chlorine (55-65%) Chlorine content calcium based granular disinfectant (45 kg sealed drum ) for water treatment, much more stable than Chorine Gas, and stronger than bleaching powder & sodium hypochoride complete all as specified and directed by Engr-in-Charge.
M&L for cleaning of internal surface of 10000 Gallons capacity Steel PS OH tank installed at height of 40' to 50' by scraping with brush, rubbing down scales, dirt, sludge etc and washing with clear using bleaching powder/caustic soda and taking all rubbish from the tank and removing the same to a distance not exc 50 mtr and applying filling compound to fill joint gap internally including the writing of date of cleaning complete all as specified and directed.
Opening completely pressure filter & oxidation chamber of capacity up to 10000 GPH and taking out existing filter media (sand, gravells), stainers and nozzles, removing (except serviceable for reuse) and depositing filter media to a distance not exceeding 50 m including necessary repair/welding to make the pressure filter vessels complete leak proof for improving the strength and finally reassembling the pressure filter including filling of new strainer, gravells & sand in existing position duly cleaned complete after replacing worn out gasket and nut bolts and washers complete all as specified and directed. Note:- (i) New nozzles, stainers, gravells shall be measured and paid seperatley. (ii) Serviceable nozzles, stainers, gravells shall be reuse after cleaning and washing and rate for same is deemed to be included in the item quoted rate.
M&L for prepration of old painted steel/iron surfaces of pressure filter & oxidation chamber by scrapping and cleaning of internal surfaces and applying two coats of black bituminious anti corrosive paint suitable for drinking water and marking the date of cleaning on the body complete all as specified and directed.
Supply and fixing in repair of PVC push type/threaded type strainer suitable for filteration plant complete all as directed.
Supplying and charging in layers special coarse sand( Barakar sand) suitable for use in filtration plant of size 1/8'' x 1/16'' mesh, complete all as specified and as directed at site.
All as per ser item No 91 here in before but 1/16'' x 1/24'' mesh complete all as specified and directed at site.
Supplying and charging in layers new washed, cleaned, dust free graded gravels filter media suitable for use in filtration plant of size above 20 mm to 40 mm complete all as specified and directed at site.
All as per ser item No 93 here in before but size above 12 mm to 20 mm complete all as specified and directed at site.
All as per ser item No 93 here in before but size above 6 mm to 12 mm complete all as specified and directed at site.
All as per ser item No 93 here in before but size above 3 mm to 6 mm complete all as specified and directed at site.
Supply and fixing in repair in layers mix of manganese dioxide (MnO2) and treated carbofil in lumps of size 20 mm to 15 mm containing 65% of manganese dioxide and 35% KG carbofil suitable for use in filltration plant complete all as directed.
Chemical Analysis (Turbidity,PH Total Hardness, Iron, Chloride, Suplhates, Fluorides, Nitrates , Calcium, Arsenic) of Raw water( before filteration) and filtered water (after filteration) for Pump Houses SFF at Doom Dooma from government labortory or NABL accredited labortory as per IS 10500 on quarterly basis, including collection of water sample and arrangements for sending the water to labortory,for testing and submission of the test report complete all as specified and directed. Note: For set of one borewell ( both after and before treating ) will be measured as one job and testing will be carried out on quarterly basis for each Pump House.
Material and labour for Cleaning, desludging and removing of all scales and dirt from external surface of OH Pressed Steel Tank of capacity 9600/10000 gallons installed at height upto 40' staging by complete removal of old paint/ rust by applying detergent and scrapping / wire brushing/sand papering and washing with clear water and painting of external/internnal surface of PS OH tank complete with two coats of aluminium paint over a coat of red oxide primer including painting of structure and connected all pipe lines (rising mains and delivery lines) from tank as per colour coading and write (Size of lettering 75 mm height) on indicated space at a height 3.5 mtr from ground level (ie. DATE OF CLEANING................, CAPACITY OF TANK ..................etc.) in black synthetic paint over white synthetic enamel paint all as directed and specified. NOTE : (a) Cost of staging/working platform involved shall be deemed to be included in the unit rate quoted. (b) Work shall be carried out in safety norms and all safety shall be provided by the contractor and no extra claim shall be admissable at later stage.
M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid.
M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick including taking out old complete all as specified.
Taking down Old burnt /Unserviceable 3.5 core 70 Sqmm underground XLPE Cable aluminum conductor LT 1100 V grade after disconnecting of electric connection all as specified and directed at site. Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule ( 2 ) Serviceable brick protection to be stacked carefully for counting and re use ,
All as per ser item No 102 here-in-before but Size of cable 50 Sqmm X 3.5 core
All as per ser item No 102 here-in-before but Size of cable 25 Sqmm X 3.5 core
All as per ser item No 102 here-in-before but Size of cable 16 Sqmm X 4 core
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs of size 70 sqmm x 3.5 core complete all as specified and as directed.
All as per ser item No 106 here-in-before but Size of cable 50 Sqmm X 3.5 core
All as per ser item No 106 here-in-before but Size of cable 25 Sqmm X 4 core
All as per ser item No 106 here-in-before but Size of cable 16 Sqmm X 4 core
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for indoor joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing 40 to 50 mm bore complete all as specified and directed.
Cutting bituminous road/ Hard path for passing of cable through 80/50/40 mm GI pipes, width not less than 30 cm and deep not less thhan 45 cm and making good to the cut surfaces by concreting PCC 1:3:6 , depth not less than 15 cm and width not less than 30 CM ) to match with the adjacent surfaces complete all as specified and directed at site.
Supply and fixing in replacement GI protection pipe of 50 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as specified. Note:- Earth work shall be measured and paid separately.
Supply and fixing steel tubes, galvanised, light grade, ISI marked 40 mm bore for protection of cable under floor, road and on wall including fixing material such as GI clamp,nut and bolts etc complete.
S&F in replacement of MCCB, 4P, 250 Amps, 35/36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, Ics100 %, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in replacement of MCCB, 4P, 200 Amps, 35/36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, Ics 100% , 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in replacement of MCCB, 4P, 100 Amps, 16 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, Ics 75% , 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in replacement of MCCB, 4P, 63 Amps, 16 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, Ics 75% , 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in replacement of on load changeover switch four pole of 250 Amps, 415 volts, 50 Hz without enclosure complete all as specified & directed. Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates.
M & L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer, complete all as directed.
Supply and stringing in repair ACSR conductor of any size for LT over head line as directed including fixing to insulators with proper size of binding wire complete.
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on LT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire, complete all as directed by Engr-in-Charge.
Supply and fix in replacement pin type, porcelain, vitreous, white brown or green insulator including one galvnised mild steel spindle, two nos galvanised iron washer and one galvnised iron nut, 100mm height, 65mm dia for 1100v grade complete all as specified & directed.
Supply and fix in replacement shackle, porcelain, vitreous, white brown or green insulator including galvnised mild steel straps, washers, insulator, bolts, washers and nuts for size 100mm height and 115mm dia for 1100 Volts with 31x5mm galvanised steel straps and 14 mm dia of bolts complete all as specified.
M&L for preparation of old painted steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enameled spray painting of approved shade all as specified.
S&F in replacement of voltmeter digital type 0-500 volts AC, flush mounting type, 3 phase complete all as specified.
S&F in replacement of ammeter digital type, flush mounting type, 3 phase complete with suitable CTs of range as required on site complete all as specified.
S&F in replacement of CTs of range 400/5Amps as required on site complete all as specified.
S&F in replacement of LED indicator as per colour scheme (Red/Yellow/Blue/Green) suitable for LT panel complete all as specified.
M&L for repair/ maintenance of LT panel door by replacement of hinges and locking arrangement including necessary welding/ nuts, bolts, washers as per existing size/ type complete all as specified and directed. (Note: (i) One side door will be measured & paid as one job). (ii) New LT panel door (only) of suitable size and thickness shall be measured and paid separately under relevant item of this schedule.)
M&L for dehydration & filteration of transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed by Engr-in-charge. Note: (a) The filtration of the transformer oil shall be carried out at different sub stations of Air Force Station Mohanbari. (b) The report before filtration & after filtration to be submitted by contractor. (c) Transformer oil for topping up will be measured and paid separately.
Supply & toping up of new transformer oil (in sealed barrel) confirming to IS 335 Std having dielectric strength 40KV at 2.5mm gap after initial dehydration complete all as specified. Make: Savita/ Castrol/ Power oil/ Truoil.
M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of 250KVA transformer (11/0.433KV) complete with all connected fittings & fixtures i.e. buchholz relay, conservator tank, cooling fins and other standard fittings & attachments as per existing colour scheme and pattern with atleast two coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction of Engr-in-Charge complete all as specified. Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates.
Material and labour for painting of erected steel tubular swaged pole of HT over head line of 11 m long (except embedded portion) complete including all MS work mounted on pole with two coat of aluminium paint after necessary preparation, cleaning including scrapping up of old corroded paint dirt/ dust/ rust carefully and providing 03 Nos bands/ straps with synthetic enamel paint (any tint 30 cm wide each) from top of plinth block and writing of pole number with white synthetic enamel paint on black back ground complete all as specified and directed by Engr-in-charge.
Disconnecting the distribution transformer outdoor/ indoor type from HT and LT side, opening carefully at site, draining out transformer oil (keeping safe in barrel for reuse) upto HT/ LT box for rectifying the leakage by replacing the unserviceable spare parts of capacity 250 KVA , 11/ 0.433 KV transformer, refilling the transformer oil and re-assembling after repair including testing for any oil leakages and connecting the HT/ LT side and testing on available electric load complete all specified and directed by Engr-in-Charge. Note:- (a) Defective parts shall be measured and paid separately as "Supply only". (b) Charge of welding work (if require) is deemed to be included in the quoted rate.
Supply only LT bushings with brass studs of 250 KVA Transformer
Supply only top cover gasket set of 250 KVA Transformer
Supply only HT bushing with brass studs of 250 KVA Transformer
Supply onlyt oil level indicator suitable for 250 KVA, 11/ 0.433 KV transformer alongwith connected accessories complete all specified and directed by Engr-in-Charge.
Supply and fix in replacement of air breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with new silica gel (blue in colour) suitable for 125 to 315 KVA, 11/ 0.433 KV transformer, fixing on existing pipe of size 15/20/25 mm dia with suitable reducer/ connector complete as per site requirement all specified and directed by Engr-in-Charge. Note:- (a) Cost of modification (if required to fix on existing MS pipe) shall be deemed to included in the item quoted rate.
Supply and fix in replacement of danger notice plate of 1.6 mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull & bones in signal red colour & fixed with & including MS clamps, bolts, nuts and of size 25 x 20cm for HT 11KV complete all specified and directed.
Supplying and laying in replacement of synthetic rubber insulated mats 2.5 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006 (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all specified and directed.
S&F in replacement of lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, 11000 volts complete all as specified and directed.
M&L for spreading of graded coarse stone aggregate 40mm nominal size to a true surface and leveled in layers not exc. 20 cm thick for switch yard complete all as specified and directed by Engr-in-Charge.
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x 6 mm buried directly in ground verticvally to depth not less than 2.25 mtr below ground level and with top edge of the plate at a depth not less than 1.5 mtr below ground level, size of dipth 0.90 x 0.9 x 2.25 mtr ,earth plate connected to galvanised earth strip of size 32 x 6mm 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing strip with Main switch/main control board,filling with charcoal dust 200 Kg, and common salt 100 KG , including necessary excavation and earth work in any type of soil ,perforated watering pipe of size 20 mm light grade ,funnel with wire mesh,earth strip protection pipe light grade of 40 mm dia, PCC chamber 1:3:6 type C1 of size 400 mm x400 mm x 400 mm (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC
Cutting and trimming of branches n.exc 50 mm dia in size obstructing lumination of street Light and touching of LT/HT Pole up to a grith of 3 mtr in both side along the conductors as per direction by Engr-in-Charge.
Cleaning around any E/M installations/ pole structures including removing all grass, creepers and other vegetations with roots on soil, hard standing and on chain link fencing complete all as directed and removing the rubbish to a distance not exceeding 50 mtr and depositing where directed.
Dismantling/taking down carefully defective any type LED street light/security light/ flood light fitting from pole/structure/bldg from any height and repair/checking and identifying of faulty spares, such as loose connection, cleaning of fittings, removing of carbon particles etc and reassembling the same in original location after testing and reconnecting with the electrical line complete all as directed by Engr-in-Charge. Note : (i) Materials required for replacement such as driver,wires, etc will be measured and paid separately under relevant items. (ii) If E-N value on security feeder is high,it should be checked and rectified without extra claim.
Supply and fix in repair LED driver suitable for 45 watt LED street light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 60 watt LED street light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 100 watt LED flood Light fitting complete all as specified and directed.
Supply and fix LED street light 45 W with minimum lumen of 4500Lm, PF >0.95 new generation energy saving and environmental friendly long life made up of pressure diecast aluminium housing with high power LED as lighting source cover having driver compartment with IP66 protection and impact resistance with built-in surge protection device suitable for mounting for pole complete including taking down of old complete all as specified and diected. Make : Crompton/ Philips/ GE.
Supply and fix LED street light 60 W with minimum lumen of 6000Lm, PF >0.95 new generation energy saving and environmental friendly long life made up of pressure diecast aluminium housing with high power LED as lighting source cover having driver compartment with IP66 protection and impact resistance with built-in surge protection device suitable for mounting for pole complete including taking down of old complete all as specified and diected. Make : Crompton/Philips/ GE.
Supply and fix LED Flood light 100 W with minimum lumen of 10000Lm, PF >0.95 new generation energy saving and environmental friendly long life made up of pressure diecast aluminium housing with high power LED as lighting source cover having driver compartment with IP66 protection and impact resistance with built-in surge protection device suitable for mounting for pole complete including taking down of old complete all as specified and diected. Make : Crompton/Philips/ GE.
Supply and fix in replacement of cable junction box IP 66 weather proof for outdoor installation (with metric knockouts for cable entry) size 205 x 255 x 112 mm suitable for 16/25 sqmm cable fixed to pole/ wall with suitable FI clamp 20X3 mm nuts , bolts and washers including provision of 01 No MCB, single pole, 240 volts, 10 KA 10 Amps, and suitable aluminium bus bar/ connector complete all as specified and directed.
Supply and fixing in replacement of PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, 1100 volts grade, three core of copper conductor for connection of street light/ flood light/ post top lantern/ garden lights etc. fittings on pole/ wall/ pillar/ from over head conductor / junction box / DB including termination clip complete in all respect complete all as specified & directed.
Supply and fix street light GI bracket,bend to 120 degree angle,made out of 40 mm bore,gI pipe,light grade (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts,bolts and washers etc and two coat of synthetic enameled paint over a coat of red oxide primer including taking down the old rusted one complete all as specified and directed.
Supply and fix in replacement of street light bracket clamps of size 32 x 6 mm made out of Galavanised iron fix with street light GI bracket and street light pole or as directed by Engr-In-Charge including suitable size three nos nuts,bolts and washers and two coat of synthetic enameled paint over a coat of red oxide primer including taking down the old rusted one complete all as specified and directed.
Carrying out routine, preventive maint & servicing of 125 KVA DG set of any Make in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center/ auth service center of OEM periodicaly or on requirement basis and replacement of unserviceable spare parts/ accessories including calibration of control devices/ refitting of serviceable parts after cleaning/ servicing including minor consumables accessories like cotton, waste cloth, kerosene oil etc including draining of oil dust from foundation/ base plate complete all as specified and directed for the following under mentioned DG set:- (a) Check clearance of suction and exhaust valves including adjust, if required. (b) Changing of oil filter, fuel filters, water filter,screen filters assy, air filter etc. (c) Topping up of coolant & changing of hydraulic governer oil. (d) Tightening of all nut bolts including greasing of all points. (e) Checking of any leaking in fuel tank and oil lines. (f) Adjusting valve tappet clearance/timing, injector pressure test, cleaning and repairing,,tightining fasteners and making lubrication leak proof. (g) Repair/ rewiring of broken/ damaged control panel connection including measuring instruments, indicators, engine protection devices etc. Note . (a): Labour charges for dismantling/ taking down and replacement/ refixing parts as and when required is deemed to be included in unit item quoted rate. (b): Spare parts like oil filter, fuel filter, water filter, screen filter by pass filter, air filter etc will be measured and paid separately.
All as per ser item No 160 here-in-before but 62.5 KVA DG Set
Supply only fuel filter assembly to the125 KVA DG set all as specified and directed f Note:- Labour charge for the same is paid under Schedule Sl item No. 128
All as per ser item No 162 here-in-before but 62.5 KVA DG Set
Supply only air filter element to the DG set of capacity 125 KVA complete all as specified and directed for following DG set:- Note:- Labour charge for the same is paid under Schedule Sl item No. 128
All as per ser item No 164 here-in-before but 62.5 KVA DG Set
Supply only lubricating oil filter to the DG set of capacity 125 KVA complete all as specified and directed at site. Note:- Labour charge for the same is paid under Schedule Sl item No. 128
All as per ser item No 166 here-in-before but 62.5 KVA DG Set
Dismantling the cylinder head assembly from engine of 62.5 KVA DG Set of any make , including overhauling of Engine and shifting to authorised workshop and back for carrying out following repair and replacement of spares as mentioned below :- Note : (a) Transporting and any type addn/altn work to be included in quotaed rate (b) Spare parts to be measured and paid and separately.
(i) Piston
(ii) Piston Ring
(iii) Liner
(iv) Liner 'O' ring
(v) CR bearing
(vi) Engine Gasket
(vii) Head Gasket
(viii) Thermostate Valve
(ix) Nozzle repair /replacement and pressure check
M & L for rewinding of DG set alternator/Stator/Rotor coil /Rectifier Coil Unit of any capacity with super enemelled copper wire of existing gauge incluiding all connected insulating material, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out of rotor with proper care and reinsulation of burnt out rotor/stator after rewinding work including re-assembling and testing on site including transporting, taking out alternator from AF Stn Chabua to auth workshop and after repair from workshop to site complete all as specified and directed at site.
S&F in replacement battery terminal cable, copper conductor with brass adaptor at both side of end point, multistrand, unsheathed, single core, 25 Sqmm, 1100 volts grade in length of 1.5 mtr long suitable for 12 Volts & upto 180 AH battery. Complete all as specified and directed.
M&L for taking out self starter 12 volt from the DG set, transportation to civil workshop and opening/ disconnecting all internal connection, cleaning the same taking out burnt armature, segrigation of serviceable parts for re-use, rewinding of armature with copper wire of existing size, assembling all parts, testing & fixing back to the DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement of fuel pipe to the DG set of various capacities complete including clip all as specified and directed.
S&F in replacement fan V belt to the DG set of capacities 125/62.5KVA all as specified and directed.
Supply & topping up heavy duty pre mixed concentrate/ anti freeze radiator coolant complete all as specified. (Make-HP/ Servo/ Castrol)
Supply & topping up distilled water for batteries complete all as specified.
S&F in replacement of battery 12 Volt, 150 Ah heavy duty complete all as specified.
Supply and filling lubricant oil 15 w 40 for topping up/replacement in engine chamber complete all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
Supply and fix in replacement AVR suitable for 62.5 KVA DG Set complete complete all as specified and directed.
Supply and fixing in repair actuator suitable for DG set of capacity 125 KVA complete all as specified and directed at site.
Supply and fixing in repair running rectifier assembly suitable for DG set of capacity 100/to 125 KVA complete all as specified and directed at site.
Dismantling the defective water pump assembly and supply and fix new water pump assembly suitable for existing DG set of capacity 100 to 125 KVA complete all as specified and directed at site.
Dismantling the defective turbo charger and supply and fix new turbocharger suitable for existing 100 to 125 KVA DG set of complete all as specified and directed at site.
Material and labour for cleaning of fuel tank of DG Sets of 125KVA/62.5 KVA capacities by taking out diesel in separate container, tank out of DG set, cleaning & removing all dirt/ sluge/ mud, dust, washing with fresh water thoroughly, drying and fixing back to its original location including making of all connection and re-filling of diesel in tank complete all as specified and directed.
Description of Work / Item(s)
Amount
S & F in repair exhaust fan louer suitable upto 300 mm sweep exhaust fan fixing with wall with with nut,bolt etc complete all as specified and directed at site
S & F in repair BLDC ceiling fan PCB suitable for 1200 mm sweep complete all as specified and directed at site
Attending day to day complaints related to electrical internal complaints such as break down/no light, repair of all electrical fittings and fixtures including wiring and repair of LT feederpillar boxs and connected works installed at various location of SB Doom Dooma etc in any type of buidings including taking down of existing material as ordered/required on working day (Week days) to attend the complaint cell by rep of contractor at 0900 AM and report to complaint cell at every evening at 0500 PM on daily basis after satisfactory completion,complete all as specified and directed. Material such as insulation tape, fuse, screws, nut and bolts, and any other minor consumables etc as per site requirement shall be included in the the quoted rate. Note :- (i) The above task will be carried out by employing one electrician and one helper by the contractor on daily basis. (ii) The complaint against docket shall be taken from MES Complaint cell at every morning at 0900 AM by rep of contractor on daily basis (iii) Every docket will submit at complaint cell of daily basis on same day at 0500 PM or early morning on next day after satisfacotry complition. (iv) Necessary T&P, complaint slip, complaint register ,equipment and safety gear shall be provided by the contractors. (v) In case non attending/rectify of complaint with in time limit by contractor, will be penalized with a penalty of double the rate quoted by the contractor in addition to the complaint not taken into consideration for payment. (vi) Material will be measured and paid separatly under respective items as supply only. However quoted rate for fixing of the same shall be deemed to be included in this item.
Supply only Switch Piano flush type single pole one way 5 amp 230 v complete all as specified and directed at site.
Supply only socket outlet 2 in 1 , 5 pin, 5 amp complete all as specified and directed at site.
Supply only Switch Piano flush type single pole one way 15 amp 230 v complete all as specified and directed at site.
Supply only socket outlet 2 in 1 , 6 pin,5 and 15 amp complete all as specified and directed at site.
Supply only ceiling rose surface type Bakelite 65x50 mm three terminals complete all as specified and directed at site.
Supply only stepped type electronic fan regulator flushType complete all as specified and directed at site.
Supply only lamp holder , PVC /Polycarbonate type with back plate suitabl for batten fittings.
Supply only Modular switch , one way, 10 ams, 1 module 230 v complete all as specified and directed at site.
Supply only Modular switch , one way, 16/20 ams, 1 module 230 v complete all as specified and directed at site.
Supply only socket outlet,modular type ,multipurpose,multipin, 6/10 amps,1 module, 230 v complete as per direction by engr in charge
Supply only socket outlet,modular type ,multipurpose,multipin, 16/20 amps ,two module, 230 v complete as per direction by engr in charge
Supply modular type fan regulator,two module, 230 v complete all as specified and directed at site.
Supply only fan capacitor 2.5 mfd
Supply only fan capacitor 3.15 mfd
Supply only LED driver suitable for 60/65 Watt LED street light
Supply only LED driver suitable for 100 Watt LED flood light
Supply only LED driver suitable for 600x 600 mm, 36/40 Watt surface mounted LED ceiling light fitting
Supply only LED driver suitable for 300x 300 mm, 18 Watt surface mounted LED ceiling light fittings
Supply only PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, 1100 volts grade, single core in 90 mtr roll
Supply only PVC insulated and PVC round sheathed, copper conductor industrial cable 2.5 sqmm, 1100 volts grade, single core in 90 mtr long
Supply only PVC rectangular block for mounting of switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep.Make : Anchor/Presto or equivalentt make approved in MES
Supply only PVC rectangular block for mounting of switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep.Make : Anchor/Presto or equivalentt make approved in MES
Supply only MCB SP 240 volt 32 Amps 'C' Series 10 KA complete all as specified and directed at site.
Supply only MCB SP 240 volt 16 Amps 'C' Series 10 KA complete all as specified and directed at site.
Supply only MCB SP 240 volt 10 Amps 'C' Series 10 KA complete all as specified and directed at site.
Supply only MCB SP 240 volt 6 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F MCB DP 240 volt 40 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F MCB DP 240 volt 63 Amps 'C' Series 10 KA complete all as specified and directed at site.
Supply only MCB DB SPN 8 way double door with metal door suitable for housing of MCBs
Supply only Casing capping of 20x12 mm
Supply only Casing capping of 25x16 mm
Supply only Rigid non-metallic PVC conduit MMS of 20 mm external dia
Supply only Rigid non-metallic PVC conduit MMS of 25 mm external dia
Supply only PVC non-metallic junction box 1 to 4 way suitable for non-metallic PVC conduit 20 mm external dia
Supply only PVC non-metallic junction box 1 to 4 way suitable for non-metallic PVC conduit 25 mm external dia
Supply only slip type bend suitable for non-metallic PVC conduit 20 mm external dia
Supply only slip type bend suitable for non-metallic PVC conduit 25 mm external dia
Supply only space bar saddle suitable for non metallic PVC conduit 20 mm external dia
Supply only space bar saddle suitable for non metallic PVC conduit 25 mm external dia
Supply only plug top 15 amps
Supply only plug top 5 amps
Supply only PVC electrical insulation Tape of size 18 mm width x 6 mtr length
Supply only LED street light 60 W
Supply only 50 mm plastic sleeve wall plugs/PVC sleeve gitti/wall column plug
Supply only 3.5 x60 mm drywall Gypsum screws
Supply only LED flood light 100 W Make : Crompton/ Philips/ GE.
Supply only LED lamp 9 watt Make : Crompton/ Philips/ GE.
Supply only 1x9W/1X10W bulkhead luminaires including LED light driver holder
Supply only LED strip suitable for 600x600 mm surface mounted LED fittings
Supply only LED strip suitable for 300x300 mm surface mounted LED fittings
Supply only surface mounted LED fitting 600x 600 mm, 36/40 Watt surface mounted LED ceiling light fitting
Supply only 18 watt surface mounted ceiling mounted LED fitting
Supply & Fix ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated complete all as specified and directed at site.Note old unsv ceiling fan to be deposited to be MES sotre
Disconnection fro socket outlets split type/window AC of capacity upto 2 ton of any brand,servicing by dusting,cleaning of indoor and outdoor units,rectifying gasleakage by applying necessary brazing,adjusting and rectifying faulty operation of elect and electronic remote control panels,replacing of perished elect wires for proper connection from voltage stabilizer, reinstalling the units to its original position,replacement of remote cell and testing complete all as specified and directed at site. Note : Spare parts shall be measured & paid separately under relevant items.
Supply and fixing in repairs copper condernser fins suitable for 1.5 Ton split/window type AC as per existing type/ make /model / complete all as specified and directed by the engr-in- charge.
Supply and fixing in repairs copper condernser fins suitable for 2 Ton split/window type AC as per existing type/ make /model / complete all as specified and directed by the engr-in- charge.
S&F in replacement of compressor unit including necessary charging the system suitable for Window/Split type AC 1.5 Ton Capacity. Note : The rate quoted by the tendred shall be inclusive of cost of refrigerant Gas the charging Gas (R22/134A) as required for the cooling appliances.
S&F in replacement of compressor unit including necessary charging the system suitable for Window/Split type AC 2 Ton Capacity. Note : The rate quoted by the tendred shall be inclusive of cost of refrigerant Gas the charging Gas (R22/134A) as required for the cooling appliances.
Supply and fix in repairs PCB board suitable for 2 Ton split/window type AC complete all as specified and directed at site.
Supply and fix in repairs PCB board suitable for 1.5 Ton split/window type AC complete all as specified and directed at site.
Supply only blower Fan motor for split type AC upto 2 ton complete all as specified and directed at site.
Supply only charging of refrigerant R-22/307 complete all as specified and as directed.
Supply and fixing in repair starting capacitor 45+6 mfd suitable for 1.5 Ton AC complete all as specified and directed at site.
Supply and fixing in repair starting capacitor 55+6 mfd suitable for 2 Ton AC complete all as specified and directed at site.
Carrying out routine, preventive maint & servicing of 62.5 KVA any make DG set in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center/ auth service center of OEM periodicaly or on requirement basis and replacement of unserviceable spare parts/ accessories including calibration of control devices/ refitting of serviceable parts after cleaning/ servicing including minor consumables accessories like cotton, waste cloth, kerosene oil etc including draining of oil dust from foundation/ base plate complete all as specified and directed for the following under mentioned DG set:- (a) Check clearance of suction and exhaust valves including adjust, if required. (b) Changing of oil filter, fuel filters, water filter,screen filters assy, air filter etc. (c) Topping up of coolant & changing of hydraulic governer oil. (d) Tightening of all nut bolts including greasing of all points. (e) Checking of any leaking in fuel tank and oil lines. (f) Adjusting valve tappet clearance/timing, injector pressure test, cleaning and repairing,,tightining fasteners and making lubrication leak proof. (g) Repair/ rewiring of broken/ damaged control panel connection including measuring instruments, indicators, engine protection devices etc. Note . (a): Labour charges for dismantling/ taking down and replacement/ refixing parts as and when required is deemed to be included in unit item quoted rate. (b): Spare parts like oil filter, fuel filter, water filter, screen filter by pass filter, air filter etc will be measured and paid separately.
All as per ser item No 68 here-in-before but 30 KVA DG Set
Supply only fuel filter assembly suitable for 62.5 KVA DG set .
All as per ser item No 70 here-in-before but suitable for 30 KVA DG Set
Supply only air filter element suitable for 62.5 KVA DG set.
Supply only air filter element suitable for 30 KVA DG set.
Supply only lubricating oil filter suitable for 62.5 kVA DG Set.
Supply only lubricating oil filter suitable for 30 kVA DG Set.
S&F in replacement battery terminal cable, copper conductor with brass adaptor at both side of end point, multistrand, unsheathed, single core, 25 Sqmm, 1100 volts grade in length of 1.5 mtr long suitable for 12 Volts & upto 180 AH battery. Complete all as specified and directed.
S&F in replacement of fuel pipe to the DG set of various capacities complete including clip all as specified and directed.
S&F in replacement fan V belt to the DG set of capacities 30 KVA to 62.5 KVA all as specified and directed.
Supply & topping up heavy duty pre mixed concentrate/ anti freeze radiator coolant complete all as specified. (Make-HP/ Servo/ Castrol)
Supply & topping up distilled water for batteries complete all as specified.
Supply and filling lubricant oil 15 w 40 for topping up/replacement in engine chamber including drain out old unsv engine oil complete all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
Material and labour for cleaning of fuel tank of DG Sets of 125/65 KVA capacities by taking out diesel in separate container, tank out of DG set, cleaning & removing all dirt/ sluge/ mud, dust, washing with fresh water thoroughly, drying and fixing back to its original location including making of all connection and re-filling of diesel in tank complete all as specified and directed.
Supply only Calcium Hypo Chlorine (55-65%) Chlorine content calcium based granular disinfectant (45 kg sealed drum ) for water treatment, much more stable than Chorine Gas, and stronger than bleaching powder & sodium hypochoride complete all as specified and directed by Engr-in-Charge.
S&F of 7/7.5 Ltr Plastic Filter Set to removes Chlorine Fluoride Heavy Metals Hard Water Softener Water complete to match with existing model complete all as specified and directed by Engr-in-charge
M&L for dehydration & filteration of transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed by Engr-in-charge. Note: (a) The filtration of the transformer oil shall be carried out at different sub stations of Air Force Station Mohanbari. (b) The report before filtration & after filtration to be submitted by contractor. (c) Transformer oil for topping up will be measured and paid separately.
Supply & toping up of new transformer oil (in sealed barrel) confirming to IS 335 Std having dielectric strength 40KV at 2.5mm gap after initial dehydration complete all as specified. Make: Savita/ Castrol/ Power oil/ Truoil.
M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of 250KVA transformer (11/0.433KV) complete with all connected fittings & fixtures i.e. buchholz relay, conservator tank, cooling fins and other standard fittings & attachments as per existing colour scheme and pattern with atleast two coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction of Engr-in-Charge complete all as specified. Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates.
Material and labour for painting of erected steel tubular swaged pole of HT over head line of 11 m long (except embedded portion) complete including all MS work mounted on pole with two coat of aluminium paint after necessary preparation, cleaning including scrapping up of old corroded paint dirt/ dust/ rust carefully and providing 03 Nos bands/ straps with synthetic enamel paint (any tint 30 cm wide each) from top of plinth block and writing of pole number with white synthetic enamel paint on black back ground complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of air breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with new silica gel (blue in colour) suitable for 125 to 315 KVA, 11/ 0.433 KV transformer, fixing on existing pipe of size 15/20/25 mm dia with suitable reducer/ connector complete as per site requirement all specified and directed by Engr-in-Charge. Note:- (a) Cost of modification (if required to fix on existing MS pipe) shall be deemed to included in the item quoted rate.
Supply and fix in replacement of danger notice plate of 1.6 mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull & bones in signal red colour & fixed with & including MS clamps, bolts, nuts and of size 20 x 15 cm for LT 1.1KV complete all specified and directed.
Supply and fix in replacement of danger notice plate of 1.6 mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull & bones in signal red colour & fixed with & including MS clamps, bolts, nuts and of size 25 x 20cm for HT 11KV complete all specified and directed.
Taking down Old burnt /Unserviceable 3.5/4 core 70 Sqmm underground XLPE Cable aluminum conductor LT 1100 V grade after disconnecting of electric connection all as specified and directed at site. Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs of size 70 sqmm x 4 core complete all as specified and as directed.
Excavation in trenches not exceeding 1.5mtrs wide & not exceeding 1.5mtr in depth as in soft/ loose soil & getting out complete all as spfd & directed.
Returning , filling in spreading, levelling, watering & well Ramming in layers not exc 25cm thick complete all as spfd & directed.
Removing excavated material not exc 50mtr & deposited where directed at a level not exc 1.5mtr above the starting point complete all as specified and directed by EIC.
M&L for Sand filling in cable trenches for cable protection with clean dry sand unwashed incl gently punning, complete.
M&L for Bricks Sub class 'B' kiln burnt, well burnt, laid as in trenches/cable cover/protection, complete.
Cutting bituminous road/ Hard path for passing of cable through 80/50/40 mm GI pipes, width not less than 30 cm and deep not less thhan 45 cm and making good to the cut surfaces by concreting PCC 1:3:6 , depth not less than 15 cm and width not less than 30 CM ) to match with the adjacent surfaces complete all as specified and directed at site.
Supply and fixing in replacement GI protection pipe of 50 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as specified. Note:- Earth work shall be measured and paid separately.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for outdoor/indoor joint complete with Jointing material heat Shrink type and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x 6 mm buried directly in ground verticvally to depth not less than 2.25 mtr below ground level and with top edge of the plate at a depth not less than 1.5 mtr below ground level, size of dipth 0.90 x 0.90 x 2.25 mtr ,earth plate connected to galvanised earth strip of size 32 x 6 mm 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing strip with Main switch/main control board,filling with charcoal dust 200 Kg and common salt 100 Kg , including necessary excavation and earth work in any type of soil ,perforated watering pipe of size 20 mm light grade ,funnel with wire mesh,earth strip protection pipe light grade of 40 mm dia, PCC chamber 1:3:6 type C1 of size 400 mm x400 mm x 400 mm (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC
M & L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer, including dismantling of old rusted cross arms etc complete all as directed.
S&F in replacement of rechargeable lead acid battery 12 Volt, 100 Ah heavy duty complete all as specified.
Supply and fixing of bottle type/cutout type fuse link of 100 Amps complete all as specified and directed
Chemical Analysis (Turbidity,PH Total Hardness, Iron, Chloride, Suplhates, Fluorides, Nitrates , Calcium, Arsenic) of Raw water( before filteration) and filtered water (after filteration) for Pump Houses No C, D, E and Tech Area at Doom Dooma from government labortory or NABL accredited labortory as per IS 10500 on quarterly basis, including collection of water sample and arrangements for sending the water to labortory,for testing and submission of the test report complete all as specified and directed. Note: For set of one borewell ( both after and before treating ) will be measured as one job and testing will be carried out on quarterly basis for each Pump House.
M&L for cleaning of internal surface of under ground sump of capacity up to 5000 Gln,by scraping with brush, rubbing down scales, dirt, sludge etc and washing with clear using bleaching powder/caustic soda and taking all rubbish from the tank and removing the same to a distance not exc 50 mtr including the writing of date of cleaning complete all as specified and directed.
M&L for disconnecting of defective air compressor from the Pump house including motor of 3 phase, capacity upto 5HP and compressor alongwith PVC pipe including disconnection electrical connection as required and dismantling spare parts of Air Compressor of any size and motor overhauling and rewinding, greasing, testing and separating the unserviceable parts cleaning the serviceable parts, re-metalling machinery polishing and re-assembling including replacement of old parts and necessary painting apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer complete all as specified. Note:- The following spare items ashall be measured and paid separately as "Supply only".
Piston for pump set
Piston oil ring
Liner
Bearing
Gear oil
Compressor air meter
Nozzle (Air)
Gate valve 1/2 inch
PVC nylon heavy duty pipe
Fan belt
M&L for dismantling defective centrifugal/mono block pump of capacity 15 HP and shifting from installation to civil work shop for repairing and replacement of Ball bearing/NDE bearing, gun metal bush, gland packing, nut bolt and washer,studs and remetaling,grinding and polishing work and other connected items/works as required for smooth functioning of pump and reassembling /fixing at site to it's original position incl testing on load for smooth functioning all as directed including transportation charges,testing and commissioning all as directed by the Engineer-in- Charge. Note :- (i) T&P items and any other minor items required for instalation and commissioning of pump set will deemed to be including in the quoted rates. (ii) Any water/electric connection,nut, bolts,washers,gaskets,flanges including welding and cutting work will deemed to be including in quoted rates. (iii) The Cost of any other spare required for smooth functioning of pump,not mentioned above is deemed to be included in the unit rate of item.
M&L for rewinding of stator of induction motor working on AC 440 volts for Centrifugal/monoblock pump set of 7.5 HP capacity with copper wire winding of appropriate existing guage including taking out old unserviceable winding complete all as specified and as directed.
Material & Labour for servicing/maintenance of fire alarm control Panel (FACP), upto 32 bit microprocessor based intelligent addressable fire alarm control system with single loop with battery backup ,once in six months all as specified and directed.
Dismantling, Servicing of multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturers instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and directed.
Supply and fixing in repair indoor addressable detectors complying with and type certified to EN-54 addressable type multisensor detector with heat and smoke combination photoelectric/optical with base with base with self built intelligence complete all as specified and directed.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe.
Supply & fix in repair 3 phase LED indicator use of ultra- bright LED for view from long distance and clear indication of phase energized status of commercial supply ,operating power 4.5 to 5 watt per phase 4 terminal wiring with one common neutral and three phase wiring, colour R,Y,B complete all as specified and directed by Engr-in-Charge
Attending day to day complaints related to external water supply such as leakage in external pipe line of any size of pipe lines, no water supply in overhead tank, no starting of sumersible pump, repair of valves, change of gasket, cleaning and backwashing of IRP plant ,pouring of chemical in BP dozer installed at various location of SB Doom Dooma etc taking down of existing material as ordered/required on all working days to attend the complaint cell by rep of contractor at 0900 AM and report to complaint cell at every evening at 0500 PM on daily basis after satisfactory completion,including excavation and earth work complete all as specified and directed. Material such as glands,petroliug gelly,oil , nut,bolt and washer and any other minor consumables items as per site requirement shall be included in the the quoted rate. Note :- (i) The above task will be carried out by employing one FGM by the contractor on daily basis. (ii) The complaint against docket shall be taken from MES Complaint cell at every morning at 0900 AM by rep of contractor on daily basis (iii) Every docket will submit at complaint cell of daily basis on same day at 0500 PM or early morning on next day after satisfacotry complition. (iv) Necessary T&P, equipment,complaint slip,complaint register and safety gear and minor spares like gasket, gland packing, screews, nutbolts etc shall be provided by the contractors with no extra cost to the department. (v) In case non attending/rectify of complaint with in time limit by contractor, will be penalized with a penalty of double the rate quoted by the contractor in addition to the complaint not taken into consideration for payment. (vi) Material will be measured and paid separatly under respective items as supply only. However quoted rate for fixing of the same shall be deemed to be included in this item.
Supply only Gun metal, globe or gate valves, with iron wheel head, screwed both ends of size 25 mm dia
Supply only GI Union 20 mm bore. Make Jindal/Tata/Unik
Supply only GI Union 25 mm bore. Make Jindal/Tata/Unik
Supply only GI Union 40 mm bore. Make Jindal/Tata/Unik
Supply only GI Socket 20 mm bore. Make Jindal/Tata/Unik
Supply only GI Socket 25 mm bore. Make Jindal/Tata/Unik
Supply only GI Socket 40 mm bore. Make Jindal/Tata/Unik
Supply only GI Nipple 6" long 20 mm bore . Make Jindal/Tata/Unik
Supply only GI Nipple 6" long 25 mm bore . Make Jindal/Tata/Unik
Supply only GI Tee equal 20 mm bore. Make Jindal/Tata/Unik
Supply only GI Tee equal 25 mm bore. Make Jindal/Tata/Unik
Supply only GI Tee equal 40 mm bore. Make Jindal/Tata/Unik
Supply only GI elbow 20 mm bore. Make Jindal/Tata/Unik
Supply only GI elbow 25 mm bore. Make Jindal/Tata/Unik
Supply only GI elbow 40 mm bore. Make Jindal/Tata/Unik
Supply only medium grade GI Pipe 20 mm bore Make Jindal/Tata/Unik
Supply only medium grade GI Pipe 25 mm bore Make Jindal/Tata/Unik
Supply only medium grade GI Pipe 40 mm bore Make Jindal/Tata/Unik
Supply only medium grade GI Pipe 50 mm bore Make Jindal/Tata/Unik
M/S S. P. ENTERPRISE (BID ID -3063576)
STANDARD ELECTRIC WINDERS (BID ID -3060512)
M/s HALDER ENTERPRISE (BID ID -3062780)
MAA COMMUNICATION (BID ID -3062992)
NChetia and Sons Trading (BID ID -3061243)
J D construction (BID ID -3063366)
FREEZCON (BID ID -3063037)
M/S S. P. ENTERPRISE (BID ID -3063576)
MAA COMMUNICATION (BID ID -3062992)
J D construction (BID ID -3063366)
STANDARD ELECTRIC WINDERS (BID ID -3060512)
NChetia and Sons Trading (BID ID -3061243)
M/s HALDER ENTERPRISE (BID ID -3062780)
FREEZCON (BID ID -3063037)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .