Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹4 L
EMD Value
₹8,000
Closing Date
8 Aug 2022, 4:30 pmClosed
Er. Sudhir Kumar Sharma
Ex. Engineer Jal Shakti Hydraulic Division Ramban
Refer to BOQ
2022_IFC_181042_2
E-NIT 34 OF 2022-23
Open Tender
Civil Works
Item Rate
25 days
Ramban
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
Ex. Engineer Jal Shakti Hydraulic Division Ramban
₹8,000
Yes
24 Aug 2022
2 Aug 2022
9 Aug 2022
2 Aug 2022
8 Aug 2022
2 Aug 2022
Amount
Providing and fixing aluminum work for doors , windows , ventilators and partitions with extruded build up standard tubular section / appropriate Z section and other sections of approved make conforming to IS : 733 and IS : 1285 , fixed with dash fastener of required dia and size including necessary filling up of gaps at junctions i.e. at top bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth , rust free , straight , mitered and joined mechanically where required including cleat angle , aluminum snap beading forglazing / paneling , , C.P brass / stainless steel screws , all complete as pre-architectural drawing and the directions of Engineer-in-Incharges powder coated aluminum (minimum thickness of powder coated 50 microns) including glazing , paneling and dash fasteners complete item. Sample Collection Rooms = 114 Sft Micro Lab = 270 Sft Staff Room = 132 Sft Total = 516 Sft
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V level.
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars
Centering and shuttering including strutting, propping etc. and removal of form for:. Shelves (cast-in-situ)
Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machinecut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed withmatching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels (Area of slab over 0.5 sqm) ( 16MM)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class deodar wood
Providing and fixing 25 mm thick shutters for cupboard etc, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws:First class kail wood
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 75 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary 100x10 mm
Providing and Fixing of Stainless steel kitchen sink - without drain board 470x420 mm bowl depth 178 mm
Providing and Fixing of Flexible (coil shaped) PVC waste pipe for sink and washbasin 32mm dia with length not less than 700 mm i/c PVC waste fittings
Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 20mm nominal outer dia pipes.
Providing and Fixing uPVC pipes (working pressure 4 kg / cm2 ) Single socketed pipe 75 mm dia
Providing and Fixing UPVC coupler for UPVC drainage pipes 75 mm
Providing and Fixing 75 mm bend UPVC pipe clip
Providing and Fixing UPVC bend 87.5° 75 mm bend
Carriage of sand from source to site of work av. 120 KM by M.T. & 50 M by manual means
Carriage of Stone aggregate 20 mm nominal size from source to site of work av. 10.00 KM by M.T. & 50 M by manual means
Carriage of Cement from nearest Market to site of work Av. 50 M by manual means
Carriage of Steel from nearest Market to site of work Av. 50 M by manual means
Carriage of Bricks from source to site of work av. 120 KM by M.T. & 50 M by manual means
ghulam nabi parihar
mubashir bashir
RAFIQ AHMED DRABOO
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .