Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.7 L+₹1.4 L (4.09%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.8 L+₹4.4 L (13.1%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹39.7 L+₹6.3 L (18.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹39.8 L+₹6.4 L (19.2%)Rejected-Finance RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L5 | Rejected-Finance Being L5 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
3 Apr 2024, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF LT INFRASTRUCTURE INCLUDING AREA LIGHTING AT STADIUM 11 GRRC PROVN OF 08 X STREET LIGHT WITH STEEL POLE INCLUDING CONNECTED ITEMS FROM OLD KLP GATE TO PERS LINE ADM BN AMC CENTRE AND COLLEGE PROVISION OF AIR CONDITIONER FOR ENGINEEER OFFRS
2024_MES_645650_1
GE/EM/LKO/EXT(ELECT)/T-02 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹88,000
Yes
15 Jun 2024
8 Mar 2024
5 Apr 2024
8 Mar 2024
3 Apr 2024
22 Mar 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning & filling in Including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick using excavated soil all as specified and directed.
Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads/path/hardstanding etc complete all as specified and as directed by Engineer-in-Charge.
Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade of size 16 Sqmm, 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed. Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
All as per item No 12 above but UG cable of size 25 Sqmm 4 core
All as per item No 12 above but UG cable of size 50 Sqmm 3.5 core
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Disconnecting the existing cable from Panel / Pole, removing the old end termination joint, preparing the end for jointing, supply and fix Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 / 4 core 10 to 16 Sqmm and reconnecting the cable in same location complete.
All as per item No 17 above but end termination joint of size 25 to 50 Sqmm
All as per item No 17 above but end termination joint of size 70 to 120 Sqmm
All as per item No 17 above but end termination joint of size 150 to 185 Sqmm
Supply drawing, connecting and testing 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
S&F wheather proof pole mounting PVC junction box, base and door of junction box made out of SMC having outside dimention 333 x 233 x 120 mm, inside dimention 300 x 200 x 105 mm, single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including S&F MCB SP 10 Amp -1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
Supply, installing, testing and commissioning factory made, CPRI approved powder coated Timer panel board (Dimention of Cubical / enclosure not less than 600mm x 450mm x 450 mm) ,cubical compartmentalized, out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The timer panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 40 x 40 x 6 mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50 x 50 x 6mm duly powder coated, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos (ii) 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC -01 Nos (iii) Astronomical Digital Timer Switch 240 V AC -01 Nos (iv) Digital VAF+PF meter with RS 485 Cl-1 -01No (v) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three (vii) Four Pole , Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 40 Amps,50 Hz,415 Volts, 16 KA thermal magnetic release - 02 Nos
Note:- Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply and installation, testing, commissioning, factory made, bus bar panel board of size 600 mm x 450 mm x 450 mm size, CPRI approved, outdoor type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 50 x 50 x 6 mm frame dust & vermin proof gasket, busbar insulated with colour coated heat shrinkable sleeves, mounted on proper insulator, overall powder coated, complete all as specified and directed & comprising of the following:-. (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 400 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
(d) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply and installation, testing, commissioning, factory made, bus bar panel board of size 600 mm x 450 mm x 450 mm size, CPRI approved, outdoor type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 50 x 50 x 6 mm frame dust & vermin proof gasket, busbar insulated with colour coated heat shrinkable sleeves, mounted on proper insulator, overall powder coated, complete all as specified and directed & comprising of the following:-. (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 160 Amps 25 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
(d) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-S grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
Supply & fix GI brackets made of 40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc complete all as specified & directed by Engr-in-Charge.
Supply, fixing and testing 60 W LED street light fitting with IP65 / 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass / polycarbonate LED lenses, surge protecton device of 10 KV External, BIS electronic potted / encapsulated driver and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core.Street light should have, impact resistance of IK 07 , Lumen efficiency of LED not less than 110 lumen per watt system efficiency, power factor >0.95, THD<10% at Full load CRI> 70% , street light should have, lower THD, open circuit protection, over voltage protection, surge voltage protection. Company LOGO ingraved on housing of the street light complete all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fix 400 W LED flood fitting having epoxy powder coated die cast aluminium housing ADC12 in grey finish with elegantly designed heat sink for efficient thermal management , sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout , PC lens/IP lens with narrow /wide beam distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,flood light should have built in potted electronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection , and provided with company LOGO ingraved on housing of the flood light complete all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply, install and erect in true vertical position steel tubular swaged welded poles complete with C.I. base plate of 6 mm thick of size 300 mm x 300 mm, B 118 finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of MS tubing conforming to IS-2713 Part II, type 410-SP-31 ( 09 meters long) poles, drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer on complete length , two coats of black bituminous paint for portion embeded in concrete, upper portion of pole painted with two coat of aluminium paint, painting three black / red bands at lower portion of pole each of 300mm height at 300mm spacing, painting pole No with black paint at suitable height including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:2:4 type B1 as in plinth block as , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed by Engr -in-charge.
Supply, install and erect in true vertical position steel tubular swaged welded poles complete with C.I. base plate of 6 mm thick of size 300 mm x 300 mm, B 118 finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of MS tubing conforming to IS-2713 Part II, type 410-SP-55 ( 11 meters long) poles, drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer on complete length , two coats of black bituminous paint for portion embeded in concrete, upper portion of pole painted with two coat of aluminium paint, painting three black / red bands at lower portion of pole each of 300mm height at 300mm spacing, painting pole No with black paint at suitable height including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:2:4 type B1 as in plinth block as , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed by Engr -in-charge.
Supply, erection and installation of 16 metre High mast shaft of approved make with raising system hot dip galvanised, having pole sheet thickness 3 mm,Top dia minimum 150 mm, Bottom dia 360 mm, base plate 32 mm thick, designed for wind speed 47 m / sec as per IS 875 part- III with head frame, winch mounting bracket, luminaries carriage suitable to install 08 Nos of flood light. Luminaries in symmetrical arrangement with raising lowering system comprising in double drum winch, 6 mm diameter SS wire rope, trailing cable, connector, suitable integral tool motor 1.5 HP, manual handle, junction box, lightening funnel including wiring material from junction box to individual luminaires with MCBs in base compartment. Foundation bolts (M 30 x 850 mm x 8 Nos) shall be of hot dip galvanized steel with high tensile strength along with nuts, washers, anchor plate and common template, suitable for LED type single dome aviation obstruction light including outdoor stand mounted feeder pillar, IP 55 made with 3.15 mm thick CRCA sheet including 01 Nos 32 Amps TPN MCB as incomer, single dial timer switch, 22 Amp TP contactor for the automatic switching of luminaries, power tool control with 02 Nos 9 Amp contactors and raise lower push button of incoming 35 Sqmm and outgoing 16 & 2.5 sq mm terminals and including construction of shallow foundation with M-25 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sq mtr at 2 meter depth. The cost of construction of RCC foundation including material shall be deemed to be included quoted unit rate.
Note:- (i) Design, drawings and all data sheets for the foundation and highmast/pole work shall be submitted to GE for approval prior to execution of work. Cost of this provision shall be deemed to be inclusive in quoted unit rate. (ii) Flood light fitting will be measured & paid seperatly under respective item of this BOQ.
Supply, installing, commissioing and testing, inverter type, high wall split Air Conditioner of capacity 1.5 TR (Hot & Cold) with degital invertor rotary compressor, Nano Titanium filter, auto clean function, indoor sound level 32 db, front panel display, wireless LCD remote, precoated aluminium fins, 477 cfm air circulation , auto fan speed, 5 star rated, electric driven , suitable for working on 230 volts, single phase, 50 Hz supply complete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall etc and remote operation complete, all as specified and directed and details as under.
(a) Fixing the indoor unit unit on wall with grouting nuts, cutting groove / hole to wall for gas pipe & water drainage pipe (b) S&F cutting, bent to shape copper refrigerint pipe (upto 3 metre length) of appropriate size with insulation from outdoor unit to indoor unit by cutting holes to wall including brazing the copper pipe fixing union including making good disturbed surfaces as existing (note copper refrigering pipe beyond 3.00 metre will be measured & paid seperatly) (c) S&F PVC pipe 20 mm dia transparent flexible heavy duty for water drainage pipe upto 06 RM length.
(d) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing & caping of size 75 x 75 mm / reqd size for mechanical protection of copper pipe complete. (e) Charging of correct qty of refrigerant gas after necessary braing/ f ixing of both the outdoor / indoor unit and testing complete on load to obtain 18 degree celsius temperature at specified amps. (f) All other connected civil work, like hole cutting & other misc work reqd for split AC for proper functioning as directed by EIC. (g) Outdoor unit shall be fixed on wall mounted stand and wall mounted stand will be measured & paid seperatly. (h) Plug top provided by contractor with wire.
Supply & fix mild steel wall mounted bracket sutable for fixing of outdoor unit of 1.5 ton split AC, fixed on wall at any height with sutable fastener as per manufacturer instruction complete
S & F metal cald type plug & socket enclosure with 2 pin and earth metal plug & socket complete with 32 Amp MCB SP C type all as specified and directed by Engg -In -Charge.
Supply & install voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 140 V to 280 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capacity 4KVA.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC rigid conduit not less than 25 mm dia and 1.8 mm wall thickness with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply & fix copper refrigerint pipe for connecting indoor unit and outdoor unit of 1.5 ton capacity split unit of size 1/2″ for suction line and 1/4″ for liquid line including insulation, cut to size, bend to shape including soldring & brazing complete. Note:- (i) 1 run of sunction line and 1 run of liquid line with insulation will be measured as 01 RM for payment.
S&F mild steel framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spiked framed guard bars barred iron doors ladders framed blasters walkways railings framework of water tanks and similar work conforming to Fe 290 Grade E-165. Note:- Quoted rates shall be deem to include fixing of grill in existing opening with sutable fasteners and making good disturbed surface
M&L for preparation of new steel surfaces, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and as directed by Engineer-In-Charge.
Enviro India
M/s A.K Construction
M K Engineers and Contractors
NAVJYOTI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .