Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹10.0 L+₹65,865.96 (7.08%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹11.1 L+₹1.8 L (19.5%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹13.5 L+₹4.2 L (45.1%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹15.5 L+₹6.2 L (66.8%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
18 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Himanshu
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2021_MES_496635_1
GE(S)/PAT-70/P/2021-22
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Patiala
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE(S) Patiala
₹60,000
Yes
4 Feb 2022
22 Dec 2021
20 Jan 2022
22 Dec 2021
18 Jan 2022
5 Jan 2022
22 Dec 2021 - 29 Dec 2021
60 days
Amount
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for cement plastering 15mm thick in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished Even and Fair without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
M&L for cement plastering 10mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified & as directed by Engineer-in-Charge.
M&L for cement plastering 10mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/ description such as cement base paint, external emulsion etc from external surfaces of walls/ RCC surfaces/ soffits of chajjas/ roof projections/ cantilevers/ balcony etc with mechanical means/ grinder complete all as specified and directed by Engineer-in-Charge.
Applying acrylic wall care putty in external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed by Engineer-in-Charge. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
Applying 02 coats of exterior emulsion paint as per manufacture instructions by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of existing old surfaces of external wall/RCC surfaces/soffits of chajjas/Roof projection/centilevers/balcony etc incl cornics and applying Two coats of Cements base paint@ 5 sqm/KG/1coat by using of cement base paint by roller /brush complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of existing old surfaces of external wall/RCC surfaces/soffits of chajjas/Roof projection/centilevers/balcony etc incl cornics and applying one coats of Cements base paint@ 5 sqm/KG/1coat by using of cement base paint by roller /brush complete all as specified and directed by Engineer-in-Charge.
M &L for preparation of 0ld plastered surfaces/unplastered surfaces incl washing,rubbing down and stoping of distempered and painted surfaces and applying one coat of Oil Bound Distemper on wall surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered surfaces/ unplastered surfaces incl washing, rubbing down and stoping of distempered and painted surfaces and applying Two coat of Oil Bound Distemper on wall surfaces complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatmenton Internal surface of any type/ description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/ grinder complete all as specified and directed by Engineer-in-Charge.
Applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior painting complete all as specified and directed by Engineer-in-Charge. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
Applying 02 coats of interior emulsion paint (light shade) as per manufacture instruction by using roller to wall surfaces over & including a coat of interior wall primer as recommanded for under coat by manufacturer of interior emulsion by using approved brands of emulsion and primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered surfaces of ceilings and applying one coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by Engineer-in-Charge.
M&L for preparing existing treated surfaces on walls and applying two coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old painted steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old painted wood & wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Writing letter of figures (block, roman italic or Indian) n exc 30cm high complete all and the colour of paint and dimension of letter to be used complete all as specified and directed by Engineer-in-Charge.
Writing stops , commas, short lines, dashes, hypens, brackets etc and the colour of paint and dimension of letter to be used complete all as specified and directed by Engineer-in-Charge.
M/s Rakesh Singla
m/s panchmukhi builders
Arneja Builders
M/s Harmans
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .