Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-Finance 221 BISARIYA COMPLEX ZONE II M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | L1 | Accepted-Finance AOC | |
| 2 | L2₹49.1 L+₹3.3 L (7.17%)Rejected-Finance | L2 | Rejected-Finance EMD return | |
| 3 | L3₹55.6 L+₹9.8 L (21.4%)Rejected-Finance S 3 S 4 1ST FLOOR SANKUL SURESH VIHAR PANSAR KOLAR ROAD BHOPAL | BHOPAL | BHOPAL | MADHYA PRADESH | L3 | Rejected-Finance EMD return | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹65.2 L
EMD Value
₹65,235
Closing Date
7 Nov 2020, 5:30 pmClosed
SHAILENDRA SHRIVASTAVA
ZONE NO.14 BMC BHOPAL
Electrification Work For Shifting of Split and Cassette Type Units and Provision For SITC work of VRF system at ISBT, Bhopal.
2020_UAD_112190_1
2020200442
Open Tender
Electrical Works
Fixed-rate
30 days
ZONE NO.14 BMC BHOPAL
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹10,000
ONLINE
₹65,235
25 Feb 2021
23 Oct 2020
9 Nov 2020
23 Oct 2020
7 Nov 2020
23 Oct 2020
Amount
Electrification Work For Shifting of Split and Cassette Type Units and Provision For SITC work of VRF system at ISBT, Bhopal.
3000012022-Conditioning unit 1.0TR / 1.5 TR / 2 TR Dismantling & Shifting, Installation, testing & commissioning of Split Air Conditioning unit 1.0TR / 1.5 TR / 2 TR capacity including indoor/ outdoor unit complete as required within town.AS PER MPPWD SOR
3000012023-Copper tube 1/4" Copper tube 1/4" - Supply, Installation, testing & commissioning of suction/ discharge copper pipe line in split Air Conditioning unit 1.0 /1.5 TR/2 TR /3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required. AS PER MPPWD SOR.
3000012024-Copper tube 5/8" Copper tube 5/8" - Supply, Installation, testing & commissioning of suction/ discharge copper pipe line in split Air Conditioning unit 1.0 /1.5 TR/2 TR /3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required.AS PER MPPWD SOR.
3000012025-2.0 TR 2.0 TR - Gas ( F 22 / 410 A ) charging of Window /Split Air Conditioning unit including flushing of cooling & condensing uni ts with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any. AS PER MPPWD SOR
3000012028-0.83TR 0.83TR - VRF / VRV INDOOR AC UNIT (WALL MOUNTED) :- Supply installation testing and commissioning of wall mounted indoor Split Unit comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, auto air swing louvers, temperature & ON/OFF display with provision of discharge angle setting by wireless remote controller including internal wiring, controls complete as per specification. (Single Phase / Three Phase) AS PER MPPWD SOR
3000012029-1.33TR 1.33TR - VRF / VRV INDOOR AC UNIT (WALL MOUNTED) :- Supply installation testing and commissioning of wall mounted indoor Split Unit comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, auto air swing louvers, temperature & ON/OFF display with provision of discharge angle setting by wireless remote controller including internal wiring, controls complete as per specification. (Single Phase / Three Phase) AS PER MPPWD SOR
3000012030-1.65TR 1.65TR - VRF / VRV INDOOR AC UNIT (WALL MOUNTED) :- Supply installation testing and commissioning of wall mounted indoor Split Unit comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, autoair swing louvers, temperature & ON/OFF display with provision of discharge angle setting by wireless remote controller including internal wiring, controls complete as per specification. (Single Phase / Three Phase) AS PER MPPWD SOR
3000012031-2.08TR 2.08TR - VRF / VRV INDOOR AC UNIT (WALL MOUNTED) :- Supply installation testing and commissioning of wall mounted indoor Split Unit comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, auto air swing louvers, temperature & ON/OFF display with provision of discharge angle setting by wireless remote controller including internal wiring, controls complete as per specification. (Single Phase / Three Phase) AS PER MPPWD SOR
3000012032-8.19TR 8.19TR - VRF/VRV INDOOR AC UNIT (HIGH STATIC DUCTABLE) :- Supply, installation, testing and commissioning of High Static Ductable type comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, with inbuilt drain pump including internal wiring, controls with cordless remote. (Single Phase / Three Phase) AS PER MPPWD SOR
3000012033-44 mm O.D.. wall thinkness ≥1.4mm (insu 44 mm O.D.. wall thinkness ≥ 1.4mm (insulation – 19 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012034-41.1 mm O.D., wall thinkness ≥1.4mm (in 41.1 mm O.D., wall thinkness ≥ 1.4mm (insulation – 19 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012035-38 mm O.D., wall thinkness ≥1.4mm 38 mm O.D., wall thinkness ≥ 1.4mm (insulation – 19 mm thick) - COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012036-34.9 mm O.D., wall thinkness ≥1.4mm 34.9 mm O.D., wall thinkness ≥ 1.4mm (insulation – 19 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012037-28.6 mm O.D., wall thinkness ≥1.2mm (i 28.6 mm O.D., wall thinkness ≥ 1.2mm (insulation – 19 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012038-25 mm O.D., wall thinkness ≥1.2mm (ins 25 mm O.D., wall thinkness ≥ 1.2mm (insulation – 19 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012039-22.2 mm O.D., wall thinkness ≥1.0mm (in 22.2 mm O.D., wall thinkness ≥ 1.0mm (insulation – 19 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012040-19.1 mm O.D., wall thinkness ≥1.0mm (in 19.1 mm O.D., wall thinkness ≥ 1.0mm (insulation – 13 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012041-15.9 mm O.D., wall thinkness ≥0.8mm (in 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012042-12.7 mm O.D., wall thinkness ≥0.8mm (in 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012043-9.5 mm O.D., wall thinkness ≥0.8mm (ins 9.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012045-6.4 mm O.D., wall thinkness ≥0.8mm (ins 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)- COPPER PIPING :- Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection.Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification. AS PER MPPWD SOR
3000012046-20 mm dia ID 20 mm dia ID - Drain Piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitile rubber insulation complete as per specification. AS PER MPPWD SOR
3000012047-25 mm dia ID 25 mm dia ID - Drain Piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitile rubber insulation complete as per specification. AS PER MPPWD SOR
3000012048-32 mm dia ID 32 mm dia ID - Drain Piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitile rubber insulation complete as per specification. AS PER MPPWD SOR
3000012049-Refrigerant R410 / 410A to compensate REFRIGERANT :- Supply and additional refrigerant charge of Refrigerant R410 / 410A to compensate the additional piping done at site for all systems including testing commissioning as required,AS PER MPPWD SOR
3000012051-Ref Nut / Y-joints brass Y JOINTS :- Supply, Installation, testing & commissioning of Ref Nut / Y-joints brass for indoor and outdoor units of suitable size as per requirement, AS PER MPPWD SOR
3000012053-24G 24G - DUCTING :- Supply and fixing of SITE FABRICATED GI sheet metal ducts in accordance with the approved shop drawings and as required as per specifications. GI sheet will be as per IS-277. All necessary GI /MS supports using thread rods (as directed). angle, flat, and anchor bolts, food grade neoprene gaskets, food grade adhesive included in the scope. AS PER MPPWD SOR
3000012054-22G 22G - DUCTING :- Supply and fixing of SITE FABRICATED GI sheet metal ducts in accordance with the approved shop drawings and as required as per specifications. GI sheet will be as per IS-277. All necessary GI /MS supports using thread rods (as directed). angle, flat, and anchor bolts, food grade neoprene gaskets, food grade adhesive included in the scope. AS PER MPPWD
3000012055-12/13 mm Thick 12/13 mm Thick - THERMAL INSULATION :- Supplying and fixing of following thickness of mat finish closed cell Nitrile rubber (class "1") insulation on existing duct after applying two coats of cold setting adhesive complete as per specifications and as required.
3000012056-10 MM Thick 10 MM Thick - INTERNAL DUCT ACCOUSTIC INSULATION :- Supply, installation, testing and commissioning of Internal duct accoustic insulation with open cell structured Class "O" fire retardent nitrile rubber with density 140 - 180 kg/m³ and specs as per RISAC Chart specfication sheet inside of the AHU supply air ducting up to 4 mtr.length from AHU mouth as per the specifications, it should have antimicrobial properties. AS PER MPPWD SOR
3000012057-GRILLS AND DIFFUSERS GRILLS AND DIFFUSERS - Supplying & fixing of powder coated extruded aluminum Square Diffuser without volume control damper complete as required. AS PER MPPWD SOR
3000012058-GRILLS AND DIFFUSERS Supplying & fixing of powder coated extruded aluminum Square Diffuser with volume control damper complete as required. AS PER MPPWD SOR
3000012059-G.I Duct Volume control damper Supplying & fixing of G.I Duct Volume control damper AS PER MPPWD SOR
3000012060-Providing & fixing of flexible canvas FLEXIBLE CONNECTIONS :- Providing & fixing of flexible canvas connection between indoor unit and duct to avoid the vibration transfer AS PER MPPWD SOR
3000012061-4Cx1.5 Sqmm Control Cable CONTROL CABLE :- Supply and laying ,testing & commissioning of following sizes of Copper conductor control cables on existing tray including fixing clamps & proper connections to equipment etc.complete as required. AS PER MPPWD SOR
3000012062-4Cx 2.5 Sqmm Control Cable CONTROL CABLE :- Supply and laying ,testing & commissioning of following sizes of Copper conductor control cables on existing tray including fixing clamps & proper connections to equipment etc.complete as required. AS PER MPPWD SOR
3000012063-Angle/Chanel/Flat iron stand OUTDOOR STAND FABRICATION :- Supply, fabrication and erection of Angle/Chanel/Flat iron stand, hanging arrangement for air conditioning machines & ducts etc, Back /Support clamps or other similar work etc.including nut bolts of required size, making holes, fabrication,welding, cutting, etc. and painting with one coat of red oxide paint& two coat of enamel paint as required as per specification.AS PER MPPWD SOR
3000012064-15 mm under deck insulation Underdeck Insulation as per specification
3000012026-48 HP 48 HP - VRV / VRF OUTDOOR AC UNIT :- Supply installation testing and commissioning of VRV /VRF /MRV outdoor units with following multiple inverter based Scroll type compressors, electronic expansion valve, R 410A /eco friendly green refrigerant, cooling & heating mode both options, special pre-coated fin type heat exchanger, low noise direct driven propeller condenser fans in each module with top discharge including internal wiring, microprocessor controls, safety. The condensing unit should be capable of providing cooling between +/- 5deg. C. to 48 deg.C & heating within 0 deg.C to 15 deg.C, COP not less than 3.3. Each system should have the provision to combine maximum 3 nos compressor in each outdoor unit ,Every single outdoor unit should not have more than maximum Capacity 20 HP (3 Phase) each compressor complete as per specification. Outdoor/Indoor units should be of same make (Brand). (Single Phase / Three Phase) (Make- LG, Daikin, Carrier, O Genral, Mitsubishi Electric) AS PER MPPWD SOR
3000012027-56 HP 56 HP - VRV / VRF OUTDOOR AC UNIT :- Supply installation testing and commissioning of VRV /VRF /MRV outdoor units with following multiple inverter based Scroll type compressors, electronic expansion valve, R 410A /eco friendly green refrigerant, cooling & heating mode both options, special pre-coated fin type heat exchanger, low noise direct driven propeller condenser fans in each module with top discharge including internal wiring, microprocessor controls, safety. The condensing unit should be capable of providing cooling between +/- 5deg. C. to 48 deg.C & heating within 0 deg.C to 15 deg.C, COP not less than 3.3. Each system should have the provision to combine maximum 3 nos compressor in each outdoor unit ,Every single outdoor unit should not have more than maximum Capacity 20 HP (3 Phase) each compressor complete as per specification. Outdoor/Indoor units should be of same make (Brand). (Single Phase / Three Phase) (Make- LG, Carrier, Daikin, O Genral, Mitsubishi Electric) AS PER MPPWD SOR
Bidder Name
Amount
Weartech Engineers Pvt Ltd(GSTN-23AABCW1561C1ZV)
KAMAL ASSOCIATES(GSTN-23ADBPA0263F1ZH)
M/S ALFA COMMUNICATIONS(GSTN-NA)
KAMAL ASSOCIATES
M/S ALFA COMMUNICATIONS
Weartech Engineers Pvt Ltd
M/S ALFA COMMUNICATIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .