Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.6 LAccepted-AOC 205 2ND FLOOR VIPUL SQUARE B BLOCK SUSHANT LOK 1 GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | 1 | Accepted-AOC L1 | |
| 2 | 2₹29.7 L+₹2.8 L (10.4%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | 2 | Rejected-Finance OTHER THAN L1 | |
| 3 | 3₹3.2 Cr+₹2.9 Cr (1080.5%)Rejected-Finance | 3 | Rejected-Finance OTHER THAN L1 | |
| 4 | 4₹32.8 L+₹5.8 L (21.7%)Rejected-Finance H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | 4 | Rejected-Finance OTHER THAN L1 | |
| 5 | Rejected-Technical SANTIPUR HILL SIDE PS BHARALUMUKH GUWAHATI 781 009 | KAMRUP METRO | ASSAM | 781009 | - | Rejected-Technical AS NO REMARKS IN WLR |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
18 Mar 2021, 6:00 pmClosed
CWE SHILLONG
HQ CWE SHILLONG SE FALLS SHILLONG MEGHALAYA - 793011
PROVISION OF HEAVY DUTY DRY CLEANING MACHINE FOR MECHANICAL LAUNDRY PLANT AT 151 BH UNDER GE GUWAHATI
2021_MES_423470_1
8461/GUW/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GUWAHATI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE GUWAHATI
₹61,000
Yes
19 Apr 2021
18 Feb 2021
20 Mar 2021
18 Feb 2021
18 Mar 2021
4 Mar 2021
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out including forming bottom surface for laying HT cable Complete all as specified and directed by Eng.-in-charge.
Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed by Engr-in-charge.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engr-in-charge.
M & L for sand cushioning to underground cable for protection with fine river sand over, UG cable laid in trenches and gently punned to cushioning to cable complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.)
Material and Labour for laying in trenches old size sub class “B” for cable protection complete all as specified and directed.
Supply and fix on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade 50 bore dia , ISI marked including necessary fittings ,clamps, bolts, nuts etc complete all as specified and directed.
Supply and lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable ,1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc, of 35 Sq.mm 3.5 core , confirming to IS specifications complete all as specified and directed.
Supply, fixing, testing and commissioning of Heavy Duty Perc Dry Cleaning Machine of capacity 10 Kg, electric heated, 03 tanks with transfer from one to another, fully computerised with manual over ride, variable speed control device for delicate fabrics and built in various electricals protections including deco filter, safety tank, doze pump, air compressor and water / oil based recovery. The machinery should mounted on suitable foundation for fixing as per OEM instructions with suitable nuts and bolts (as required) complete all as specified and directed. Make: FABCARE Model No 160FDQ or equivalent to XSONI Systems / XCEL. NOTE: 1. Cost of PCC foundation and nuts, bolts are deemed to be inclusive in the unit rate. 2. Installation of Machine shall be done only authorised representative of manufacturer. 3. Suitable Demo/tranining shall also be given to MES representative after installation. 4. Manufacturer test report / Purchase voucher shall be submitted by Contractor before claiming of payment.
Supply and fixing of Percholoroethylene (PERC) for Heavy Duty Dry Cleaning Machine of 330 Kg original packing drum all as specified and directed. Make: ARCO CHEM or its equivalent make.
M&L Sub main wiring with 16 Sqmm (Nominal area) with four runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor cables 1100 V grade drawn through and including PVC casing capping of adequate size but not less than 25mm width including 10 sqmm (nominal area) two runs of single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed. Note- One run PVC casing capping, four runs main cable and two run of earth wire shall be measured as one unit length.
Supply and fix MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. (Note: 1. MCB SP/TPN shall be measured and paid separately under appropriate items of this schedule. 2. Copper thimble shall be used for connection of cable). Make: Indoasian / Havells / L&T
Supply and fix of MCB four pole 63 Amps 10 KA C Curve complete all as specified and directed. Make: Indoasian / Havells / L&T
Supply and fix of MCB four pole 32 Amps 10 KA C Curve complete all as specified and directed. Make: Indoasian / Havells / L&T
M&L earthing complete with galvanized steel earth plate 600 x 600 x 6mm thick buried directly in ground pit not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level connected to & including galvanized iron strips 32 X 6 mm duly encased in 40 mm bore light grade GI protection pipe both up to 7.5 mtr in length by means of nuts bolts check nut and washers of GI starting from earth plate to panel/transformer side all as specified and including necessary excavation earth work, PCC pit 40mm RCC cover made RCC (1:2:4) type B1 using 20mm graded stone aggregate concrete reinforced with 8mm dia bars 75mm C/C both ways with MS handle 12mm dia PGI funnel wire mesh and GI pipe light grade 20mm for watering starting from top edge of the plate complete all as specified and testing as per SSR -Part 1.The earth plate shall be surrounded with adequate quantity of charcoal dust with common salt, packed on all side of earth plate in alternate layers of thickness 15 cm each including excavation, earth work in any type of soil, returning and filling in, removal of surplus soil to a distance upto 50 mtr complete all as shown on electrical plate No. 3 of SSR Part- I complete all as specified and directed.
M/S SEWAK SINGH
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
M/S. SUBHAS CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .