Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹55.1 L+₹15.2 L (38.1%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
14 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
PROVISON OF CERTAIN LBW, REV AND MINOR WORKS IN THE AREA OF AGE E/M E/S UNDER GE (WEST) JABALPUR
2020_MES_405125_1
8296/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
Yes
GE (West) Jabalpur
₹96,000
22 Jan 2021
19 Dec 2020
16 Jan 2021
19 Dec 2020
14 Jan 2021
31 Dec 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation ,laying of cable or pipe ( where provide for protection of cable or fixing poles and stay and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engr-in-charge.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point.
Supply and Laying sand cushioning with dry and clean sand over and under the cable in trenches , ducts for cable protection. (Note - Punned thickness of sand shall be considered for payment)
Supply and Laying Best quality locally available, sub class B bricks (Old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of the cable complete all as specified and as directed by Engr-in-charge.
Supply & laying 40mm bore galvanized steel tubing "light grade" with GI fittings in trenches/ under roads/ along pole/ wall for cable protection including suitable clamps for fitting on wall etc all as specified & directed by Engineer in Charge
Supply & laying 80mm bore galvanized steel tubing "light grade" with GI fittings in trenches/ under roads/ along pole/ wall for cable protection including suitable clamps for fitting on wall etc all as specified & directed by Engineer in Charge
M&L for Drlling (Horizontally) existing road (Maximum 10 mtr length) suitable for passing GI tubing upto 80 to 100mm complete all as specified and directed.
Supply and fixing LED flood lights not less than 150 watts, nominal voltage 240 volts, 50 Hz, high efficiency long life LED module with SMD LED package mounted on MCPCB, lumen efficacy of LED shall not be less than 100 lumen/W, Colour temp (CCT) -5700K and viewing angle of 120 degree to ensure better uniformity, epoxy powder coated pressure die cast aluminium housing elegantly designed heat sink for efficient thermal management, high quality toughened glass IK 07 fixed to housing, having electronic driver, integral, isolated electronic driver with lower THD, output open/short circuit protection, over voltage protection, surge voltage protection with SPD not less than 10 KV and other safety test as per IS 15885 Part-2/Sec 13, having adjustable MS cradle of thickness 5mm provided with the fixture by 2 elliptical slots complete all as specified and directed, Make -Philips Cat part No BVP122 LED 150CW HE SY20° ORION-3.0/200W LTEF200WHPLED, Crompton Cat Part No LSFO-200-CDL/60
M&L for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth strip 32X6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-2009 (Part-I) including charcoal dust common salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including providing 40mm dia GI pipe light grade with all fittings for protection of GI strip including PCC pit 1:2:4 type B-1 using 20mm graded stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm steel bars 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engr in charge and testing for required value complete. Note:- If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including on surface PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel not less than 1.2mm thick with earth dolley terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistrand copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
(a) One light/fan point Exhaust fan controlled by one switch.
(b) Ditto all as per above item but of 2.5 Sqmm copper cable
S&F Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed by Engineer in charge
S&F Exhaust fan heavy duty size 300 mm sweep, 230 v, 50 Hz , with louvers complete all as specified and directed by Engineer in-charge. Make- Crompton Greavs, Bajaj, Khaitan, Orient
S&F Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
S&F Exhaust fan heavy duty size 380 mm sweep, 230 v, 50 Hz , with louvers including making holes and making good to distrubed surface complete all as specified and directed by Engineer in-charge. Make- Crompton Greavs, Bajaj, Khaitan, Orient
S&F Switch socket combination 3 pin 5 and 15 Amps AC 230 volts complete all as specified and directed by Engineer in charge Make- Anchor, Plaza, Leader.
M & L for Cutting hole in existing wall for outlet of chimany and making good the distrubed surface using PCC 1:2:4 type B-1 and 10mm thick cement plaster in CM 1:3 to match with the existing surfaces complete all as specified and directed by Engineer in charge.
Supply and laying or fixing or passing through pipe connecting and testing of XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
(a) 35 Sqmm 3.5 core
(b) 240 Sqmm 3.5 core
M & L for concealed Sub main wiring, with two runs of 6 sqmm single core PVC insulated unsheathed multistranded with copper conductor cable , 1100 Volts FRLS grade ISI marked drawn through in and including non metalic, rigid PVC conduite pipe & including one run of 4 sqmm PVC insulated unsheathed stranded copper conductor cable green in colour for earth continuity conductor in and including cutting/chasing in brick masonary wall and making good the distrubed surfaces after fixing the work and clearing the site complete all as specified and directed. Note :- Two runs of 6 sqmm cable and one run of 4 sqmm earth wire and PVC conduit pipe shall be measured as one length.
M&L for concealed sub main wiring with 4 run of 16 sqmm single core PVC insulated unsheathed multistranded with copper conductor cable 1100 volts FRLS grade ISI marked drawn through in and including non metalic rigid PVC conduit pipe 25mm dia and including two run of 10 sqmm PVC insulated unsheathed stranded copper conductor cable green in colour for earth continuity conductor in and ncluding cutting/chasing in brick masonary wall and making good the distrubed surfaces after fixing the work and clearing the site complete all as specified and directed Note :- Four runs of 16 sqmm cable and Two run of 10 sqmm earth wire and PVC conduit pipe shall be measured as one length.
M & L for concealed Sub main wiring, with two runs of 4 sqmm single core PVC insulated unsheathed multistranded with copper conductor cable , 1100 Volts FRLS grade ISI marked drawn through in and including non metalic, rigid PVC conduite pipe & including one run of 2.5 sqmm PVC insulated unsheathed stranded copper conductor cable green in colour for earth continuity conductor in and including cutting/chasing in brick masonary wall and making good the distrubed surfaces after fixing the work and clearing the site complete all as specified and directed. Note :- Two runs of 4 sqmm cable and one run of 2.5 sqmm earth wire and PVC conduit pipe shall be measured as one length.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
S&F fix GI earth continuity wire of size 4mm dia fixed on wall with suitable size PVC conduit pipe for protection of earth continuity conductor with shadle and screws complete all as specified and directed
S&F change over switch 630 Amps ON load in sheet enclosure four pole 415 volts 50Hz with sheet steel enclosure, including cable gland to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed. Make : L&T/C&S/ABB/Schineider
Supply & Fixing 1200 mm sweep ceiling fan, copper wound motor, 5 star rating suitable for 230 volt AC supply heavy duty complete with making necessary electric connection with ceiling rose with 3 core copper wire of size 0.50 sqmm for connection complete including suitable size of clamp, nuts, bolts with required length of GI pipe etc all as specified & directed by Engineer-in-Charge.Make : Havells/orient/khaitan/Bajaj/Usha
Suply and fixing LED light 2x2 feet of 36 watt capacity complete all as specified and directed Make of Cat Part No Bajaj - BZRSQL36W or Wipro CRC010R036HP57G1 or equivalent in Phhilips
Supply and fixing 20 watt LED security light fitting out door type with stove enamelled finish sheet aluminium housing with CRCA sheet steel reflector, ribbed acrylic bowl cover and accessorieds with 40mm dia GI pipe light grade bracket fixed with 30 x 5 mm FI clamp with nut bolts and washers completed in all resepct as specified and directed by Engineer in Charge Make : Philips Cat Part No BRP022 LED CW MR S1 PSU GR or equivalent in Havells/Crompton/Wipro
Supply and fixing LED solar lights,fitting complete set with inbuilt 12.8V 9Ah NIC battery 6 meter long 50mm dia galvanized pipe pole, 6meter length, including necessary excavation, PCC, nuts and bolts, 12 Watt light source, Solar All -in-one Standard complete all as per model No 12W All- in- one Standard, Product Code -112568 of Bajaj or equivalent make as approved by the GE complete all in one solar street lilght complete all as per specifications as under :-
Light Source - 12W
Solar Panel-20W (MONO)
PIR Sensor- to be provided
Shall be of IP 65
LED Panel - 01 Nos
LED lamp power-BRIDGELUX
No of LED-12x1 =12 Nos
LED lamp life- not less than 50000 Hrs
Battery life(LiFePO4)-12.8V, 9 AH
Charge controller shall be of MPPT type
Efficiency CC shall be in between 90-96%
CRI shall be abt 80%
Dimention(MM) shall be not less than495x355x80mm
Full load working lumen shall be of 1200LM and less load working 475lm, lumen /watt shall be 120lm
Visual angle shall be 120 degree and colour temperature shall be 6000K-6500K and full power shall be 10 hrs, working time in saving mode shall be of 48 hrs, the mounting height shall be 3-4mtr
Mounting pipe dia shall be of 100 mm dia,
The sollar charge controller shall have following parameters
(i) System voltage - 12V
(ii) Output power 50W/12V
(iii) Output current 0.15-303A
(iv) No load loss 9mA/12V
(v) Efficiency of constant current 90 to 96%
(vi) Over voltage protection 16.0V
(vii) Charging voltage limit-15.5V
Note : Necessary excavation, earth work, PCC, R&F and removal shall be deemed to be included in the unit quoted rates
Supply, installation, connecting, commissioning and testing of electrical Chimney with all necessary fixing arrangements as required at site with suction fans with galvanised iron sheet 22 Guage with min 1100 m3/hr suction capacity baffle filter with stainless steel duct pipe of suitable length as required at site and jali corrossion resistant setup of suitable size to avoid birds/rodents including clamps angle iron, nuts, bolts, required, complete with all accessories all as required and directed at site.Make: Hindware Elena auto clean 60 or equivalent
Supply, installation, connecting, commissioning and testing of electrical Chimney with all necessary fixing arrangements as required at site suitable for 6 to 7 gas stove setup with 2 suction fans with galvenised iron sheet 22 Guage with min 1100 m3/hr suction capacity baffle filter with stainless steel duct pipe and jali corrossion resistant setup of suitable size to avoid birds/rodents including clamps , complete with all accessories all as required and directed at site.
Supply, install, connecting with mains and for input and output and battery, commissioning and testing of online UPS of out put capacity 30 KVA 3 phase 415 Volts, +/- 1%, frequency 50 Hz, +/- 0.5%, Volts, input 340V to 480 Volts, AC, 50 Hz +/- 3%, three phase AC, minimum 85 % overall efficiency, overload withstand shall be not less than 10% over load for 1 minutes and 540% overload for 10 sec, the UPS shall have overvoltage, shortcuircuit and over load at UPS output terminals, under voltage at battery terminals, overshoot and unershoot shall be greater than 4 % of rated voltage for duration of 40ms, MCCB shall be provided input, the UPS shall be provided proper indications and meters , main presence, battery charging and discharging, output overload, low battery voltage, Digital meers for inuput AC voltage, output AC voltage, load percentage and frequency, battery voltage and current, true online UPS, inverter technology, with recifier, perfect generator compatibility, isolation transformer inbuilt complete in and including battery 30 Nos of battery , 12volts, 100 Ah connected in series or parrallel as per site requirement so as to make the UPS functional in all respect with necessary stand and with minmum 2 years warranty of battery complete all as specified and directed of Make :- Microtek, Volina, , Luminous, V -Guard
Supply and fixing industrial wall mounted plug socket suitable for IP 67 degree of protection of capacity 32 Amps rating 2P+E complete all as specified and directed, Make - Legrand, Schneider, ABB
M&L for Design, supply, erection, commissioning and testing of indoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 630 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation LT Panel complete and including the followings :
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, Make of LT Panel : Mc Layer Pvt Ltd, Tricolite, Asian Switchgear
INCOMING :- MCCB 630 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, electronic release Make Legrand -422075 or equivalent make of ABB, Seimens - 01 Nos
INCOMING :-Automatic transfer switch, 630 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, Make Legrand , ABB, Seimens - 01 Nos
OUTGOING : (a) MCCB 250 Amps, 4 pole, 415 volts, 36 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420249, ABB, Seimens - 04 Nos
(b) MCCB 200 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420218, ABB, Seimens - 02 Nos
(c) MCCB 160 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420217, ABB, Seimens - 01 Nos
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos
Make : Legrand, L&T, Hager, Havells
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos
Make : L&T, Hager, Havells
(f) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos
(g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01)
Make : CG/L&T/Siemens
(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos
(j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos.
(k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No.
(l) Danger Notice Plate -02 Nos
(m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos
(n) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos
(o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area) ' Make of Panel - Asian Switchgear/ Tricolite/Universal Switchgear/ Mc Layer Pvt Ltd
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
M&L for Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 6mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947.
The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. Make of LT Panel : Mc Layer Pvt Ltd, Tricolite, Asian Switchgear
(Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 600mm width and 500mm depth).
Supply, installation, commissioning and testing of latching High mast made up of galvanised special steel conforming to IS, ASTM- A- 572/BN -EN -10025 continuously tapered 12 sided polygonal cross section suitable for lighting system. it shall be suitable for wind speed as per IS-875, Part- 3, 1987 single section of length approximately 12.5 meters to sustain as arising wind speed as per is 875 . An opening door shall be provided at the base that shall access to quipment installed in it in and including providing of winch & cable Plug and socket, double lock paddle, raising & lowering mechanism, lantern carriage ring suitable to carry 06 Nos LED light of wattage above 150 watts, whinch head frame, torque motor, limitor switch, cable trailing which, aluminium Pulley, stainless steel wire rope AISI 316 grade, 7/19 construction in and including suitable terminal box shall be provided at base compartment of high mast for terminating incoming cables made up of special rubber trailing with EPR insulation and PVC sheathed & suitable power electrically driven tool shall couple with winch using sprocket motor mounted at base of mast with compartment one number heavy duty hot dip galvanised lighting finial shall be of 1.2 mtr in length shall provide centre of head frame, suitable earthing terminal at base minimum 12mm diameter GI nuts and bolts, base plate shall be not less than 520mm, 25mm thick, bottom of the mhigh mast shall be not less than 360mm and top shall be not less than 150mm dia in and including providing foundation bolt manufactured from special steel and hot dip galvanised alongwith nuts and bolt fixing the same in PCC foundation and base plate of high mast complete all as specified and directed in and including the following :-
(a) Excavation, returning and filling in excavated soil, removal of surplus soil from site and depositing upto meter in low laying area as directed by Engr-in-charge at site
(b) Material and labour for construction of foundation for 12.5 meter high mast considering the soil load bearing capacity 10 ton/sqm at 2 meter depth, proposed foundation details enclosed as appendix 'A' ( the contractor shall submit the foundation drawing with complete details for approval by the Engr-in-charge before progressing the work at site)
(c ) Providing of suitable size and length of cable from terminal block in base of High mast upto LED light with the provision of rolling winch which can be operable at the time of taking down of light carriage from top to bottom.
Note : 1. The contracotr will make the High Mast functional in all respect, if anything missed out, the contractor shall provide the same without any extra cost or claim to the department 2. The contractor shall submit warranty of material for material for one year from the date of certified date of completion
Design, supply, erection, commissioning and testing of outdoor type LT feeder pillar box, double door, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Copper bus bar not less 200 Amps mounted FRP insulators for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (09) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032.
The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.15mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom and having welded equal angle of 75mmx75mmx6mm of length 0.9mtr, 04 nos, 30cm of of angle shall be embedded in PCC 1:2:4, 20mm graded stone agregate below GL level and 30cm shall be above ground level of size as directed by Engr-in-charge at site. The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. Necessary cable gland shall be provided for all incoming and outgoing cables. The feeder pillar shall be comprising of the followings and all as shown in drawings :- Make of LT Panel : M/s MC Layer Pvt Ltd, Tricolite, Asian Switchgear
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-stranded type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
Cable Alley : Necessary cable alley shall be provided for out going cables in both sides of LT panel with terminal block, the terminal block shall be connected with the outgoing MCCB/MCB with copper bas bar of suitable size
INCOMING : 4 pole MCCB having breaking capacity 16 KA ,thermal magnetic release of rating 63Amps, 415 Volts, 50 Hz. - 01 No (Make : Schneider, ABB, Legrand)
OUTGOINGS : (a) 4 pole MCB having breaking capacity 10 KA , 'C' series of rating 40 Amps. - 01 No (Make : C&S /LEGRAND/ L&T/ABB)
(b) 4 Pole MCB having breaking capacity 10 KA , 415 Volts f rating 32 Amps. - 03 No (Make : Schneider, ABB, Legrand)
(c) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos (Make : Schneider, ABB, Legrand)
(d) Power contactor four pole with coil voltage 230 volt of capacity 16 Amps 50 cycles.Cat Part No 412544 of Legrand - 02 Nos (Make : Schneider, ABB, Legrand)
(e) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos and other standard instrumentation complete (Make : Schneider, ABB, Legrand)
(f) Toggle switch auto off manual
(g) MCB SPN having breaking capacity 10 KA , 230 Volts of rating 06 Amps. - 03 No (Make : Schneider, ABB, Legrand)
Metering and Instrumentation
(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos
(j) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.
(k) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos
Make : Legrand, L&T, Hager, Havells
(l) Digital Ammeter 96mm x 96mm suitable to read 0 to 200 Amps, accuracy class 1% - 01 Nos
Make : L&T, Hager, Havells
(m) Current transformer (CT) of rating 200/5, tape wound, rated burden 5 VA - 03 Nos
(n) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.
(Note : 1. The feeder pillar Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 750 mm height (without base frame & canopy), 500mm width and 450mm depth).
S&F aviation obstruction light, yellow painted die-cast aluminium alloy housing LED twin lights , heat resistent clear thick glass and accessories all as specified and directed connected electrically from LT feeder Pillar box to aviation lights of suitable length of size 2.5sqmm, 3 core industrial, copper flexible cable all as direted by Engr-in-Charge (Note : The rate of copper cable and its fixing shall be deemed to be inclussive in unit quoted rated)
M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) for coping of poles/pipe/plateform/path etc including necessary form work and finished surfaces complete all as specified and directed by Engineer in Charge
Supply, installation, commissioning and testing of outdoor type, 440volts, AC, LT, APFC panel of 60 KVAr capacity, factory fabricated, made out of 3.15mm CRCA sheet, CPRI approved, duly wiring with copper flexible wire of suitable rating for power control , Panel shall be dully powder coated with 8 tanks sheet treatment ( De-greasing, water rinsing, de-rusting, water rinsing, Activation- phosphating, water rinsing, (Passivationthickness of powder coating shall no be less than 80 microns) in and including the following :-
(A) Incoming
(i) MCCB, 415 volts, 4 pole, 160 Amps, 25 kA with rotary Handle Mechanism - 01 Nos
(iv) LED indication lamp 230 Volts, AC 22.5mm dia RYB-03 Nos
(v) MCB 2 Amp, Single Pole-03 Nos
(vi) Microprocessor APFC relay with single CT sensing 12 stages auxilary supply 230volts, AC - 01 Nos
(vii) Aluminium busbar 25x10mm, TPN - 01 Set
(viii) Auto/Manual Switch - 01 Nos
(B) Outgoing
(i) Capacitor 20 KVAr ultra heavy duty 440V cylindrical - 01 Nos
(ii) Capacitor 10 KVAr ultra heavy duty 440V cylindrical - 01 Nos
(iii) Capacitor 05 KVAr ultra heavy duty 440V cylindrical - 06 Nos
(iv) MCB Triple pole 63 Amps, 10 kA, 'C' sries - 01 Nos
(v) MCB Triple pole 32 Amps, 10 kA, 'C' sries - 01 Nos
(vi) MCB Triple pole 16 Amps, 10 kA, 'C' sries - 06 Nos
(vii) Capacitor duty contactor 3 pole 20 KVAr - 01 Nos
(viii) Capacitor duty contactor 3 pole 10 KVAr - 01 Nos
(ix) Capacitor duty contactor 3 pole 05 KVAr - 06 Nos
x) 22.5mm dia Push Button ON/OFF-08 set
(xi) 22.5 mm dia LED Red - 08Nos
(xii) 22.5mm dia LED Green-08 Nos
(xiii) Armoured 2 core copper cable 1.5sqmm shall be provided for sensing CT
(xiv) Sensing CT as per site load condition shall be provided alongwith APFC Panel
(xv ) All power connection shall be done with 1100 volts FRLS copper flexible wire with copper termination of proper size and proper type
Make : MCCBs/MCB/LED/PB/Capacitor/Contactor/APFC : L&T/Siemens/Schneider
Make (APFC Panel) Tricolite/ Mc Layers/Universal Switchgear)
Note (i) GA drawing for APFC panel shall be got approved from the Accepting Officer/Engineer-in-charge before manufacturing of APFC panels
(ii) Pre dispatch inspection shall be arranged for routine test at manufacturer's works by the contractor
(iii) Test report for powder coating shall be provided with panels
(iv) The manufacturers shall have inhouse 8 tanks Powder coating Process Plant to avoid defective process
(v) PCC plateform of suitable size shall be provided after demolition of existing PCC plateform, The cost of all above shall be demmed to be included in unit quoted rates.
S&F aviation obstruction light, yellow painted die-cast aluminium alloy housing LED twin lights , heat resistent clear thick glass and accessories all as specified and directed connected electrically from LT feeder Pillar box to aviation lights of suitable length of size 2.5sqmm, 3 core industrial, copper flexible cable all as direted by Engr-in-Charge (Note : The rate of copper cable and its fixing shall be deemed to be inclussive in unit quoted rated)
Supply & fixing water heater storage type [Geyser] and Installed on walls with screw bolts grouted on wall by drilling holes, of capacity 25 litre five star rating BEE complete all as directed by Engineer-in-Charge. Make : Bajaj/Havells/Usha Lexus/Recold
Supply & Fixing single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with & including one number MCB SP 20/25 Amps complete all as specified & directed.
Supply & Fixing PVC connection 15mm size with PTMT nuts on both ends of length 450mm complete all as specified & directed.
Supply & Fixing 15mm bore stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipe or for union complete all as specified & directed.
Supply & Fixing 15mm bore bib tap cast copper alloy screwed down for iron pipes or for brass ferrule complete all as specified & directed.
S&F GI water tubes of size 15 mm bore medium grade, galvanised with all fittings, fixed to walls/ceiling or laid in floors etc complete all as specified and directed.
Supply and fixing 3 core 1.5 sqmm copper conductor cable all as specified and directed by Engineer in charge.
Sachdeva Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .