| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹18.4 L+₹27,615 (1.53%)Rejected-Finance 16 B DR AMBEDKAR ROAD SAROSH APARTMENTS PUNE 411001 | PUNE | MAHARASHTRA | 411001 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹19.3 L+₹1.2 L (6.82%)Rejected-Finance | L3 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
20 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Pune
GE (Central) Pune Arjun Marg Pune-411001
REPAIR AND MAINTENANCE OF FANS GEYSERS, SOLAR WATER HEATERS AND CONNECTED ALLIED ITEMS IN AFMC LOWER VC OMMAND HOSPITAL NURSING MESS NURSING COLLEGE AND OTHER AREAS UNDER GE (CENTRAL) PUNE
2024_MES_639345_1
8459/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Central) Pune
As per NIT
8 documents required · 8 mandatory
₹500
GE (Central) Pune
₹60,000
Yes
2 Apr 2024
27 Jan 2024
22 Feb 2024
27 Jan 2024
20 Feb 2024
8 Feb 2024
Amount
Taking down ceiling fan / Exhaust Fan / wall mounting fan of any size , sealing cable end, dismantling blades and removing fan and blades to store yard of AGE E/M complete all as directed. Note : Necessary Issue voucher / receipt voucher shall be made with contractor while handing over and taking over the fans.
Hanging only ceiling fan / Exhaust fan / wall Fan of any size after refixing of fan blades, checking the condition of MS clamps, rubber reels of hanging rod including replacement of split pin and nut & bolts complete all as specified and as directed. Note : Necessary Issue voucher / receipt voucher shall be made with contractor while handing over and taking over the fans.
M & L for cleaning, servicing and overhauling of ceiling / exhaust / wall mounting fan including lubricating , greasing and painting with one coat of synthetic enamel white paint and writing MES No on it complete all as directed of following sizes :-
(a) Ceiling fans of 1200/1400mm Sweep
(b) Exhaust fan of 150 to 450mm sweep
(c) Wall mounting fan of any sweep
M & L transporting the ceiling / exhaust / wall mounting fans to local workshop for rewinding complete, replacement of super enamelled copper winding wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete and depositing to AGE E/M store yard for refixing on site all as directed of following. Note : Necessary Issue voucher / receipt voucher shall be made with contractor while handing over and taking over the fans.
(a) Ceiling fan 1200/1400mm sweep working on 230 Volts AC supply
(b) Exhaust fan upto 150/ 200/ 250/300/350/ 450mm sweep working on 230 Volts AC supply
(c) Wall mounting fan of any sweep, working on 230 Volts AC supply
Supply and fixing in replacement of following spare parts :-
(a) Bearing 6200 .
(b) Bearing 6203 ZZ .
(c) Terminal connector 3 way Bakelite
(d) Brass, gun metal bushing suitable for 1200/1400mm sweep ceiling fan.
(e) Capacitor 2.5 MFD 230 Volts complete all as specified and directed.
(f) Capacitor 4 MFD 230 Volts complete all as specified and directed.
(g) Canopy for ceiling fans (Set of two) complete all as specified.
(h) MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400mm sweep ceiling fan complete all as specified.
(j) Down rod made out of GI pipe medium grade 20mm bore dia with fan clamps including drilling , cutting threading etc all as directed for ceiling fan 1200/1400/1500mm sweep of following sizes:-
(i) 2 feet long
(ii) 4 feet long
(iii) 6 feet long
Taking down geyser 25/50 Ltrs capacity from existing location, servicing of geyser of including cleaning, overhauling, spray painting with one coat of synthetic enamel paint and writing MES number and refixing the geyser to its original position complete all as directed.
S & F in replacement thermostat ISI marked suitable for the 25 Ltrs to 50 Ltrs capacity Geysers complete all as specified and as directed.
S & F in replacement fusible plug ISI marked suitable for 25 to 50 ltrs capacity Geysers complete all as specified and as directed.
S & F in replacement safety valve ISI marked suitable for 25 to 50 Ltrs capacity Geysers complete all as specified and as directed.
S & F in replacement of heating element including rubber washers (ISI marked) of following rating as required at site (any type) complete all as specified and as directed.
S & F in replacement of storage inner tank made out of copper sheet suitable for following capacity geysers complete all as specified and as directed.
(i) 25 Ltrs capacity
(ii) 50 Ltrs capacity
S & F in replacement 15mm bore dia & 60cm long PVC connections pipe with brass hexagonal adapters both side suitable for cold water complete all as specified and as directed.
S & F in replacement 15mm bore dia & 60cm long PVC connections pipe with brass hexagonal adapters both side suitable for for hot water complete all as specified and as directed.
S & F in replacement 15mm / 20mm bore dia brass non return valve ISI marked complete all as specified and as directed.
S & F in replacement indicators of Geysers 25 to 50 Ltrs capacity complete all as specified and as directed.
S & F in replacement gasket rubber ring for Heater plate of any size Geysers complete all as specified and as directed.
S & F in replacement outer container made out of CRCA sheet duly painted suitable for following capacity geysers complete all as specified and as directed.
(i) 25 Ltrs capacity Geyser
(ii) 50 Ltrs capacity Geyser
S & F in replacement of Apparatus plate assembly suitable for Geyser 25 to 50 Ltrs capacity all as specified and as directed.
S & F cable PVC insulated PVC Sheathed 3 core , 2.5 Sqmm with stranded copper conductor 1100 Volt grade , ISI marked including taking out old existing worn ou cable complete all as specified and as directed.
S & F in replacement hot water tank 500 Ltrs capacity made out of steel sheet 2mm thick including replacement of hot water piping insulation with glass wool , wire mesh & aluminium cladding (24 gauge) complete all as specified and as directed.
S & F in replacement hot water tank 100 Ltrs capacity made out of steel sheet 2mm thick including replacement of hot water piping insulation with glass wool , wire mesh & aluminium cladding (24 gauge) complete all as specified and as directed.
S & F in replacement solar tubular collectors ISI marked suitable for 500 Ltrs capacity Solar Water Heater including replacement of rubber gasket, aluminium strip & making connection etc complete all as specified and as directed.
M & L in replacement solar tubular / glass collectors with glass ISI marked suitable for solar geyser 100 Ltrs capacity including replacement of rubber gasket, aluminium strip & making connection etc complete all as specified and as directed.
S & F in replacement 20mm bore dia brass gate valve including fittings, connection etc complete all as specified and as directed.
S & F in replacement 15mm bore dia brass bib tap including fitttings, connection etc complete all as specified and as directed.
Servicing & overhauling of solar collector system of capacity 500/100 LPD by cleaning & opening of choked tubes & replacement of rubber gasket & repair to dismantled / damaged alum strip, aluminium clidding complete all as directed.
S & F 500 Ltrs capacity rotational moulded polythylene water storage tanks of tripple layers (cylindrical vertical with colsed top) hoisted and fixed in postion including all necessary GI fittings such as nipple, union / sockets etc and connecting up pipes etc including dismantling old water tanks complete all as specified and directed.
S & F in replacement heating element 3 KW suitable for solar water heater (Hybrid Type) of existing make & shape including making connection & testing complete all as specified and directed.
Repairs to hot water tank of capacity 500/100 Ltrs by welding / brazing where required to avoid leakage after dismantling of hot water & cold water pipes , connection , aluminium cladding including testing of leakage etc complete all as directed.
S & F 20mm bore dia hot water GI tubing medium grade including insulation & connection such as glass wool , wire mesh & aluminium cladding including taking down old GI tubing with insulation etc complete all as specified all as specified and directed.
S & F 15mm bore dia hot water GI tubing medium grade including insulation & connection such as glass wool , wire mesh & aluminium cladding including taking down old GI tubing with insulation etc complete all as specified all as specified and directed.
S & F PVC insulated & sheated copper conductor cable of size 4.0 Sqmm , 3 core , 1100 Volt grade , ISI marked including taking out old existing worn out cable complete all as specified all as specified and directed.
Supply and Fix self adhesive printed sticker of vinyl sheet and of size 10 x 3 cm with writen letter GE( C) Pune all as specified & as directed.
M/S CHANDAN BUILDERS
Sparkh Electricals & Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .