Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC 408 409 HAASH BUSINESS CENTER NR ANKUR SCHOOL FATEHPURA PALDI AHMEDABAD 380007 | AHMADABAD | GUJARAT | 380007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.2 L+₹30,315.50 (1.09%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹28.6 L+₹71,575 (2.57%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹30.5 L+₹2.6 L (9.35%)Rejected-Finance | L4 | Rejected-Finance Not being L1 |
Tender Value
₹31.9 L
EMD Value
₹63,801
Closing Date
21 Aug 2024, 6:00 pmClosed
Senior Manager (Engg Elect.)
Senior Manager (Engg.Elect.), Airports Authority of India, Operational Offices, Maharana Pratap Airport, Dabok, Udaipur 313022 (Rajasthan)
Rate Contract of Internal Wiring and Associated works at M.P. Airport Udaipur
2024_AAI_203104_1
AAI/UDR/EE/24-25/INT. WIRING
Open Tender
Electrical Works
Item Rate
365 days
Maharana Pratap Airport, Dabok, Udaipur (Rajasthan
As per WNIT
17 documents required · 17 mandatory
₹1,180
₹63,801
2 Jan 2025
30 Jul 2024
23 Aug 2024
31 Jul 2024
21 Aug 2024
31 Jul 2024
31 Jul 2024 - 7 Aug 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group A
Group B
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq . mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2X2.5sq. mm +1 X2.5sq. mm earth wire
2X4sq. mm +1 X4sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface/recessed steel/PVC conduit as required.
1 x1.5sq. Mm
2x1.5sq. Mm
2x2.5 sq. Mm
3x2.5 sq. Mm
2x4 sq.Mm
3x4 sq. Mm
Supplying and fixing of following sizes of steeI conduit along with accessories in surface/recess including painting in case ofsurface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch (Anchor penta or equivalent)
5/6 A switch (Gold medal Aura or equivalent)
15/16 A switch (Anchor penta or equivalent)
15/16 A switch (Gold medal Aura or equivalent)
3 pin 5/6 A socket outlet (Anchor penta or equivalent)
3 pin 5/6 A socket outlet (Gold medal Aura or equivalent)
6 pin 15/16 A socket outlet (Anchor penta or equivalent)
6 pin 15/16 A socket outlet (Gold medal Aura or equivalent)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or2 Module (75mmX75mm) (Anchor penta or equivalent)
1 or 2 Module (75mmX75mm) (Gold medal -Wega metallic or equivalent)
3 Module (100mmX75mm) (Anchor penta or equivalent)
3 Module (100mmX75mm) (Gold medal -Wega metallic or equivalent)
4 Module (125mmX75mm) (Gold medal -Wega metallic or equivalent)
6 Module (200mmX75mm) (Gold medal -Wega metallic or equivalent)
8 Module (125mmX125mm) (Gold medal -Wega metallic or equivalent)
12 Module (200mmX150mm) (Gold medal -Wega metallic or equivalent)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module (Gold medal -Wega metallic or equivalent)
3 Module(Gold medal -Wega metallic or equivalent)
4 Module(Gold medal -Wega metallic or equivalent)
6 Module (Gold medal -Wega metallic or equivalent)
8 Module (Gold medal -Wega metallic or equivalent)
12 Module (Gold medal -Wega metallic or equivalent)
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6Amodular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16Amodular switch, connection etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.
Group A
Group B
Group C
Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connection, painting etc. as required.
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) (Honeywell, IHPSPNDD012 or equivalent)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)
4 way (4+12), Double door (Honeywell, IHPTPNDD404 or equivalent)
6 way (8+18), Double door (Honeywell, IHPTPNDD006 or equivalent)
8 way (8 + 24), Double door (Honeywell, IHPTPNDD008 or equivalent)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 As tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (8 + 24), Double door (Honeywell, IHPVMCBDD08 or equivalent)
Supplying and fixing 5 Ato 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 25 A rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Aeres in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 25 A, four pole, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli aeres in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32A 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32A 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Boxes (IP 43) suitable for following trippie pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with testing and commissioning etc.
For4way, Double door TPN MCBDB
For 6 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
Supplying and fixing Cable End Boxes (IP 43) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 volts, on surface/ recess, complete with testing and commissioning.
SITC of Digital Ammeter having size 96mm x 96mm for existing electrical panels with programable CT ratio.
SITC of Digital Voltmeter having size 96mm x 96mm for existing electrical panels.
Supply of Quartz type daily timer switch suitable to operate at 110ac -240ac, 50Hz.(L&T GIC or equivalent)
ANUKOM ENTERPRISES
Manish Electricals
M/s Sogani Electrical
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .