Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAccepted-AOC 8 1 B PAHARPUR HOUSE DIAMOND HARBOUR ROAD ALIPORE KOLKATA WEST BENGAL 700027 | KOLKATA | WEST BENGAL | 700027 | ₹5.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.2 CrRejected-AOC BEHRAMPUR ROAD BEHRAMPUR ROAD KHANDSA GURGAON GURGAON HARYANA 122001 UDYAM HR 05 0000018 06AAACM6798C1ZD R M MII STATUS AS VERIFIED | GURUGRAM | HARYANA | 122001 | ₹5.2 Cr | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical UNIT NO 121 ANDHERI INDL PREMISES CO OP SOCIETY 22 VEERA DESAI RD ANDHERI W MUMBAI MAHARASHTRA INDIA 400053 | MUMBAI SUBURBAN | MAHARASHTRA | 400053 | - | - | Rejected-Technical As per NIT Part-2 clause No. 15.10. The Part-1 of evaluation shall be done based on the data provided in excel sheet and the relevant uploaded supporting documents. As the bidder has not filled excel sheet. Therefore, not considered for evaluation. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Bidder has mentioned conflict of interest Yes In point no. 15 of format-1 of NIT. Hence the bidder is disqualified as not meeting the general eligibility criteria point no. 11.2 of Part-1 of NIT. |
| Sl No | Description | Qty | Unit | Paharpur Cooling Towers Limited L1 | MM AQUA TECHNOLOGIES LTD L2 |
|---|---|---|---|---|---|
| 1.00 | Supply of PVC fill type C10.19, (Munter's PVC film type fill) in white colour, 0.25mm thick, double edge folded, UV inhibited in nested sheet of different size including cost of preparation of fills in the block form by gluing/pasting by machine ,removal of existing old fills and refixing the same with newly fabricated PVC fills in NDCT at locations with suitable arrangement including cost of providing all necessary tools & tackles, transportation,man power, erection / de-erection of scaffolding (approx. height upto 15 meter), transportation of the removed old PVC fills ,shreding of the same at their own cost and dispose off the waste material like old PVC fills/sand/dust etc.(generated after shreding) at low lying area (s) within the periphery up to 10.0 Km lead including sweeping/cleaning the area in side and around NDCT complete as per direction of the Engineer in charge. Note:- a) Different size block of fills shall be used as per field condition. However typical dimension is provided in technical report. b) Measurement of block of PVC fill installed at location shall be considered for payment in Cum. c) No recovery shall be made angaist the old removed PVC fills which are to be taken out from RAPS 5&6 area after shreding and no extra payment is to be made against transportation, shreding of PVC fills and disposal of waste etc. d) Shreding machine, tools and tackles, covering arrangements around the machine is to be arranged by the contractor at his own cost. e) All pieces of PVC fills shall be removed either by vaccum or sweeping around the NDCT within 2 km area. f) Removed/fabricated PVC fills shall be transported directly from NDCT basin to designated shreding area and not to be stored nearby basin area. | 2,900 | Cum | 16,850 ₹4.9 Cr | 17,450 ₹5.1 Cr |
| 2.00 | Removal, Providing & Fixing of PVC pipe of OD 200 mm in NDCT as per IS:4985, for 6 Kg/cm2 pressure rating with one end socket for self connection of Supreme/Finlox/Astral/Kasta as approved make or equivalent.
Note:-
1. Nozzle shall be Provided By Department.
2. Other consumables i.e. rivet, pvc strip and clip shall be arranged by the Contractor 3. Shifting of removed pipe shall be done by contractor at his own cost. | 500 | Mtr. | 2,248 ₹11.2 L | 2,750 ₹13.8 L |
| 3.00 | Providing & Fixing of PVC Coupler for connecting of ID 200 mm pipes of 6 Kg/cm2 pressure rating. | 150 | No | 1,575 ₹2.4 L | 2,000 ₹3 L |
| 4.00 | Providing & Fixing of PVC End CAP Threaded from Inner Side with socket of ID 200mm and 6 Kg/cm2 pressure rating. | 50 | No | 850 ₹42,500 | 1,250 ₹62,500 |
Tender Value
₹4.6 Cr
EMD Value
₹9.2 L
Closing Date
26 Aug 2025, 3:30 pmClosed
Chief Superintendent
RAPS-5 and 6, RR Site
Removal of old PVC fills along with associated components and providing, fixing, and erecting of new PVC fills along with associated components at location in NDCT-6 during Biennial Shutdown of Unit-6, RRS- 5and6, Plant Site.
2025_NPCIL_243910_1
NPC/RRS/56/2025/CPT-A2865
Open Tender
Civil Works
300 days
RAPS-5 and 6, RR Site
As per tender documents
4 documents required · 4 mandatory
₹0
₹9.2 L
Head (CMMWG) office
12 Jan 2026
5 Aug 2025
27 Aug 2025
5 Aug 2025
26 Aug 2025
19 Aug 2025
5 Aug 2025 - 12 Aug 2025
14 Aug 2025
Amount
Supply of PVC fill type C10.19, (Munter's PVC film type fill) in white colour, 0.25mm thick, double edge folded, UV inhibited in nested sheet of different size including cost of preparation of fills in the block form by gluing/pasting by machine ,removal of existing old fills and refixing the same with newly fabricated PVC fills in NDCT at locations with suitable arrangement including cost of providing all necessary tools & tackles, transportation,man power, erection / de-erection of scaffolding (approx. height upto 15 meter), transportation of the removed old PVC fills ,shreding of the same at their own cost and dispose off the waste material like old PVC fills/sand/dust etc.(generated after shreding) at low lying area (s) within the periphery up to 10.0 Km lead including sweeping/cleaning the area in side and around NDCT complete as per direction of the Engineer in charge. Note:- a) Different size block of fills shall be used as per field condition. However typical dimension is provided in technical report. b) Measurement of block of PVC fill installed at location shall be considered for payment in Cum. c) No recovery shall be made angaist the old removed PVC fills which are to be taken out from RAPS 5&6 area after shreding and no extra payment is to be made against transportation, shreding of PVC fills and disposal of waste etc. d) Shreding machine, tools and tackles, covering arrangements around the machine is to be arranged by the contractor at his own cost. e) All pieces of PVC fills shall be removed either by vaccum or sweeping around the NDCT within 2 km area. f) Removed/fabricated PVC fills shall be transported directly from NDCT basin to designated shreding area and not to be stored nearby basin area.
Removal, Providing & Fixing of PVC pipe of OD 200 mm in NDCT as per IS:4985, for 6 Kg/cm2 pressure rating with one end socket for self connection of Supreme/Finlox/Astral/Kasta as approved make or equivalent. Note:- 1. Nozzle shall be Provided By Department. 2. Other consumables i.e. rivet, pvc strip and clip shall be arranged by the Contractor 3. Shifting of removed pipe shall be done by contractor at his own cost.
Providing & Fixing of PVC Coupler for connecting of ID 200 mm pipes of 6 Kg/cm2 pressure rating.
Providing & Fixing of PVC End CAP Threaded from Inner Side with socket of ID 200mm and 6 Kg/cm2 pressure rating.
MM AQUA TECHNOLOGIES LTD (BID ID -888699)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Excelformats.xls
BOQ • 0.16 MB
GCCnew.pdf
Tender Documents • 3.30 MB
BOQ_278590.xls
BOQ • 0.33 MB
eTenderCPTA2865.pdf
Tender Documents • 3.70 MB
Download all tender documents and submit your bid