Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.3 LAccepted-AOC | 1 | Accepted-AOC Lowest | |
| 2 | 2₹44.5 L+₹2.2 L (5.16%)Rejected-Finance | 2 | Rejected-Finance Higher | |
| 3 | 3₹48.4 L+₹6.1 L (14.4%)Rejected-Finance | 3 | Rejected-Finance Higher |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Nov 2020, 4:00 pmClosed
GE Amritsar
GE Amritsar PIN-143001
PROVN OF 01 X STORE WITH PARTITION IN PRC, STORE ROOM AND SHED WITH HARDSTANDING OF 13 ELINT SUB GP AND CSD STORE AT OLD AMRITSAR CANTT
2020_MES_368156_3
GE/ASR-20/2020-21
Open Tender
Civil Works
Item Rate
273 days
GE Amritsar
Class D, category ai
8 documents required · 8 mandatory
₹500
GE Amritsar
₹90,000
Yes
13 Nov 2020
5 Oct 2020
5 Nov 2020
5 Oct 2020
4 Nov 2020
13 Oct 2020
Amount
B/R PORTION Excavating in post holes( or similar holes) each n exc 0.5 cu.m. getting out and removing surplus soil to a distance n.exc 50 m and making good surface. (16)
M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate cement concrete in foundations, filling and mass concrete all as specified and as directed. (3.46 + 3.85 + 4.11 +3.85)
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 all as specified and as directed. (1844)
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and as directed. (84)
M&L two coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of previously untreated surfaces all as specified and as directed. (60)
M&L Hardcore of broken bricks gauge n exc. 63 mm, deposited , spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all asspecified and as directed. (9.60 + 9.00 + 9.00 + 9.00)
M&L PCC (1:5:10) type E-2 using 40mm graded stone aggregate in foundation,mass concrete complete all as specified and as directed. (7.68 + 4.50 + 4.65 + 5.25)
M&L 100mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate in floor of surface complete all as specified and as directed. (64)
M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm sealed with sealing compoud all as specified and as directed. (3.20)
M&L for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. (6.00 + 34.52 + 36.82 + 34.52)
Surface dressing n exc 15 cm deep in soft/loose soil all as specified and as directed. (146.94 + 156.74 +146.94)
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Hard / dense soil complete all as specified and as directed. (35.45 + 37.81 + 35.45)
M&L RCC M-25 (Design Mix) using 20 mm graded stone aggregates as in column footings, plinth beams all as specified and as directed. (25.20 + 26.88 + 25.20)
All as per item No 13 above but as in columns. (4.60 + 4.91 +4.60)
All as per item No 13 above but as in beams. (8.40 + 8.96 +8.40)
All as per item No 13 above but as in chajja and fascia. (0.54 + 0.58 + 0.54)
All as per item No 13 above but as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like (13.80 + 14.72 + 13.80)
M & L mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified and as directed. (3300 + 3520 + 3300)
M & L mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed. (907 + 967.47 + 907)
Use & waste of formwork to sides of fair finished flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces (67.62 + 72.13 + 67.62)
All as per item No 20 above but to sides of pillars, posts, struts, columns and stanchions. (54.60 + 58.24 +54.60)
All as per item No 20 above but to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc. (89.60 + 95.57 + 89.60)
All as per item No 20 above but to chajjas and similar items including edges. (5.40 + 5.76 + 5.40)
All as per item No 20 above but to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) (111.10 + 118.51 + 111.10)
M&L for 15mm rendering in cement mortar (1:4) on brick/concrete surfaces finished the surface even and smooth without using extra cement all as specified and as directed. (156.94 + 167.40 + 156.94)
M & L for 15mm rendering in cement mortar (1:6) on brick/concrete surfaces finished the surface even and smooth without using extra cement all as specified and as directed. (172.80 + 184.32 + 172.80)
M&L for preparation of newly plastered surfaces of walls & applying two coats of white wash wall surface and all as specified as directed by Engr-in-Charge all as specified and as directed. (172.80 + 184.32 + 172.80)
M&L for preparation of newly plstered wall surface and applying two coats of cement Base all as specified and as directed. (156.94 + 167.40 + 156.94)
M&L for preparation of surfaces and applying two coats of white wash ceiling surface and all as specified as directed. (111.10 + 118.51 + 111.10)
Filling in floors using surplus excavated soil, spreading and levelling in layers n exc. 25 cm thick and rammed including watering. (13.20 + 14.08 +13.20)
M & L for hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface in broken boulder complete all as specified and as directed. (13.20 + 14.08 + 13.20)
M & L for 100 mm thick, PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in Sub base for flooring finishing surfaces of concrete topping even & rough to receive the topping layer complete all as specified and as directed. (88.00 +93.87+ 88.00)
M&L for 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) (88 + 93.87 +88)
M&L for ATT, Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface (88 + 93.87 + 88)
M&L for Machine cut Kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20mm thick screed bed in CM 1:6. (88 + 93.87 + 88)
All as per item No 35 but CM 1:4, 10 mm thick on skirting all as specified and directed (8 + 8.53 + 8)
M& L for Box type steel window double (glazed & gauged) made of ERW tube P- section of size 60 mm x 25 mm double rebated outer frame comprise glazed skelton shutter door frame of ERW tube P-section size 50 mm x 20 mm with two Nos openable leaf cnsisting of two Nos of sash bar of T-sec 20 mm x 3 mm welded to frame with one No vertcale mullion of ERW of ERW box type T-section size of 60 mm x25 mm FI 2 mm thick welded / screwed to frame for fixing of wire guage/glass including fixture and fitting like as handle, tower bolt stopper , cleat, pintal hinges, holdfast primer etc, all as shown on drg No.CEJZ/TD-06/07 and CEJZ/TD/07/07 complete. (11 + 11.73 + 11)
S/F framed work as door, chowkhats, and Grill gates of angle frame work fixed with Nut & bolt to wall or other section complete drilling or fixing welding be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also festering and fixing complete. (53.90 + 57.49 + 53.90)
M&L for PCC 1:3:6 type B-1 (using 20 mm graded stone aggregate) in bed blocks for hold fast & similar work etc complete all as specified and directed. (0.25 + 0.27 + 0.25)
S & F factory made 35 mm thick flush shutters solid core construction with block board core and plywood face panels. (5.85 + 6.24 +5.85)
S&F butt hinges 100mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised type C-21 all as specified. (12 + 13 +12)
S&F extruded aluminium alloy handles, fabricated type, anodised all as specified of size 150mm long (8 + 9 + 8)
S&F 300mm long aluminum alloy anodized sliding door bolt with hasp and staple(bolt type)and fixing clips of sheet cast or ectruded sec and fixing bolts and sliding bolts of extruded sec or cast aluminum alloy and fixed all as spd and directed. (3+ 3+ 3)
S&F butt hinges medium weight cold rolled mild steel complete size 100mm (6+ 6+ 6)
S&F 200mm long aluminum anodized barrel tower bolt of extruded section and fixed all as spd and directed. (8 + 9 + 8)
S & F frame work such as grills/guard bars grating etc with ends of bars complete all as specified and directed. (149.82 + 159.81 + 149.82)
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exc 0.5 sqm in each pane complete all as specified and directed. (7.15 + 7.63 + 7.15)
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or galvanized wire staples. (7.15 + 7.63 + 7.15)
M&L for preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint). (33 + 35.20 + 33)
M&L two coats of synthetic enamel paint over a coat of pink primer over wooden surfaces including preparation fo surfaces complete all as specified. (14.04 + 14.98 + 14.04)
M&L for 75mm thick cement concrete type C-2, 1:3:6 using 40mm graded aggregate as in plinth protection etc (40 + 42.67 + 40)
M & L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm at 180 degree temperature in each layer ( first layer below APP membrane and second layer above APP membrane) on 0.40 kg/sqm bitumen primer surfaces including cleaning surfaces etc complete all as specified and directed. (119.09 + 127.03 + 119.09)
M & L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on bitumen surfaces by forced application complete all as specified. (119.09 + 127.03 + 119.09)
M&L for 15mm rendering in cement mortar (1:4) on concrete surfaces finished the surface even and fair mixed with water proofing compound without using extra cement all as specified and as directed. Note: - water proofing compound shall be measured separately. (119.00+127.03+119.09)
Supply only water proofing compound
M & L 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska (119.09 + 127.03 + 119.09)
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.(66+ 65 + 62+ 70)
M&L for Machine pressed pre-cast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment over 25mm thick sand filling. (58+62+68)
M&L Providing, cement concrete Type C1, 1:3:6 ((20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges (0.80 + 1.00 + 1.35)
E/M PORTION M & L Wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, FR multistranded with copper conductor conforming to IS specifications, drawn through and including 20 mm PVC conceled conduit concealed/ fixed on wall / ceiling with suitable clamps, screws, etc or concealed in wall including terminal boxes fabricated with 1.6 mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc, including provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified and as directed :-Make of wire RR Kabel/Poly cab/Havells (a) One light point/Bell/Fan point controlled by one switch.(10+10+3) Note : The wiring shall be done in proper colour coding using red, yellow & blue for phase, black for neutral & green for earth lead.
All as per item No 60 above but one 3 pin 5 amps switch socket on independent board. (1+1+1)
All as per item No 60 above but one 3 pin 5 amps switch socket on same board. (1+1+1)
All as per item No 60 herein before but with cable 2.5 sqmm (nominal area) multistranded copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continous earth wirte PVC insulated 2.5 sqmm copper multistranded conductor connecting to common earth and earth dolly complete all as specified and directed . (1+1) Note for item Nos 60 to 63 : The wiring shall be done in proper colour coding using red, yellow & blue for phase, black for neutral & green for earth lead.
Supply and fix switch piano one way 5 A, SP, 230 Volts.Make Anchor/Plaza/SSK (12+12+5)
Supply and fix Socket outlet 2 in 1, 3 pin 5 Amps Flush type. Make Anchor/Plaza/SSK (2+2+2)
Supply and fix Switch outlet 2 in 1, 3 pin15 Amps Flush type. Make Anchor/Plaza/SSK (1+1)
Supply and fixing ceiling rose surface bakelite 3 terminals 65x32mm complete all as specified Make Anchor/Plaza/SSK (10+10+3)
Supply and fix wall/ceing mounting LED 18 Watt 6000k PC Diffuser tube light fitting complet with all aceesories 1x18W LED suitable for domestic application 240Volts 50HZ including one tube rode and internally pre-wired with 1.5 sqmm twin twisted flexible copper conductor and complete . Make Havells/ Wipro /Philips (8+8+2)
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. Make Schneider/Siemens/Legrand (1+1+1)
S & F in repair MCB double pole, 240 volts, 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. Make Schneider/Siemens/Legrand (1+1)
S & F in repair MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. Make Schneider/Siemens/Legrand (2+2+2)
Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed. Make Anchor/Plaza/SSK. (1+1)
Supply and fixing /laying galvanised pipe 25 mm bore medium grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. (7+12)
S & F Ceiling fan 50W, 1200 mm sweep inlcuding fan hook and all accessories complete with including fitting and fixtures as per site requirement and complete accessories 230 Volts single phase 50 Hz AC supply and connectin up with and including two core PVC insulated, PVC sheathed copper conductor all as specified and directed. Make: Havells /Orient/Crompton Greaves. ( 2+2 )
Supply and fix in replacement of security light fitting LED 25 Watt 5700k aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old CFL security light fitting all as specified and as directed of Make Havells/Wipro/Philips (2+2)
S& F GI bracket light grade GI Pipe 1.2 mtr Length for fixing of street light fitting 36/40 Watt including connection all as specified and directed. (2+2)
M & L for laying of LT cable of 1100 volt XLPE insulated and PVC sheathed of size 10 sqmm 2 core with cable gland including taking down old unserviceble cable complete all as specified and directed by Engineer-in-Charge.Make : Havells / polycab / finolex . (110+80)
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth all as specified & directed. (19+12)
Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified& directed. (10+7)
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed. (9+5)
M & L for brick protection to cable using old size sub class 'B' bricks, laidflat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified & directed. (0.70 + 0.50)
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of calbe in trenches complete all as specified & directed. (7+3)
S&F energy saving new generation 10 watt LED, 6000k bulk head luminaire with opal diffuser light fitting complete with all acessories and connection complete. Make Philips/Wipro/CG
S & F in repair MCB double pole, 240 volts, 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. Make Schneider/Siemens/Legrand
S & F PVC body fresh air heavy duty 250 mm sweep complete including cutting of wall louvers etc complete all as specified & directed. Make : Havells/Cromplton/Orient.
M & L service connection PVC cable 6 sqmm 2 core including GI wire & PVC conduit for fixing in wall / pole connection complete all as specified & directed. Make : Havells / Polycab / Finolex.
M/s. M Company
tarlok singh contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .