Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.7 LAccepted-AOC | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹39.8 L+₹1.6 L (4.33%)Rejected-AOC | 2 | Rejected-AOC 2nd | |
| 3 | 3₹43.6 L+₹5.5 L (14.3%)Rejected-AOC D 2 212 JEEVAN PARK PANKHA ROAD UTTAM NAGAR WEST DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | 3 | Rejected-AOC 3rd |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
19 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
ADDN/ALTN/IMPROVEMENT TO RECEIPT AND DISPATCH (R/D) HANGAR AT LGS SECTION AT 12 BRD UNDER GE (AF) TUGHLAKABAD
2022_MES_559467_1
GE/TKD-32/2022-23
Open Tender
Civil Works - Others
Item Rate
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹96,000
Yes
28 Dec 2022
22 Oct 2022
21 Nov 2022
29 Oct 2022
19 Nov 2022
5 Nov 2022
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed by Engr-in-Charge.
M&L for bricks works with sub class "B" bricks straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and as directed by Engr-in-Charge.
M&L for marble stone chipping of desired colour grit wash on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement : 4 coarse sand) the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 12mm white cement plaster (1:1/2:2) (1 white cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed by Engr-in-Charge.
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15mm thick in cm (1:4) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement including taking down cement plaster or concrete, brick surface and raking out hacking for key scrubbing down with water to receive plaster complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15mm thick in cm (1:6) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement including taking down cement plaster or concrete, brick surface and raking out hacking for key scrubbing down with water to receive plaster complete all as specified and as directed by Engr-in-Charge. Note: The work to be executed at the height of 12 to 15 mtr the rate for necessary scaffolding deemed to be included in the quoted rate.
M&L for two coats with distemper oil emulsion over a coat of primer on new plastered surface on wall complete all as specified and as directed by Engr-in-Charge.
M&L for applying two coats of cement base paint white or tinted on newly plastered wall surface including preparation of surface complete all as specified and as directed by Engr-in-Charge.
M&L for preparing old distempered surface of wall complete removal of existing treatment and applying two coat of oil emulsion distemper over 1 mm thickness birla/JK wall care putty complete all as specified and as directed by Engr-in-Charge.
M&L for preparing old distempered surface of wall complete removal of existing treatment and applying two coat of cement base paint complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm and but n,exc 4 Sqm each for archives soffits, linings window boarss etc complete all as specified and as directed by Engr-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C. P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engr-in-Charge.
S&F for anodised aluminium frame (minimum 50 micron powder coating) for doors, windows, ventilators with one or more rebates including cleat for fixing etc complete all as specified and as directed by Engr-in-Charge.
S&F Aluminium powder coated of any colour (thickness or powder coating not less than 50 micron) doors shutters aluminium section weighing 0.55 Kg/Sqm including necessary jointing cleats glazing clips rubber neoprene packing hangles two nos in each door hinges anodised aluminium snap beading screws complete all as specified and as directed by Engr-in-Charge.
S&F aluminium colour powder coated (shade or tint as directed by GE) window frame of three track using Jindal or equivalent section NO 20832 (92x31.75x1.50mm) fixed thrust bolt in walls by drilling and sliding shutter of section No 20844(40x18x1.29) or equivalent section for glass or wire mesh fixed with rubber beading and bushes complete in two track aluminium beading complete all as specified and directed by Engr-in-Charge. Note: Glass & wire cloth shall be measured and paid separately under respectively item of this schedule.
S&F 12mm thick prelaminated particle board interior grade prelaminated both side with decorative choice lamination fixed with screws to timber frame work or as in cubicals, partition or cupboards, complete all as specified and as directed by Engr-in-Charge.
S&F double action floor spring hydraulically regulated made up of aluminium 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by Engr-in-Charge.
S&F stainless steel wire cloth (SS-304 grade) 0.36 mm nominal dia of wire and average with of aperture 1.40 mm and fixed with stainless steel wire staples with wooden/aluminium beads/ screws to window/door complete all as specified and as directed by Engr-in-Charge.
S&F 4 lever brass mortice lock, vertical type, size 100 mm complete all as specified and as directed by Engr-in-Charge.
S&F steel rolling shutter with ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete gear operated type with bevel gear box and cranked handle (1.25 mm thickness of laths) complete all as specified and as directed by Engr-in-Charge.
S&F Ball bearing for rolling shutters complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete reinforced in any position incl cut of bars as required complete all as specified and as directed by Engr-in-Charge.
M&L for reinforced cement concrete(1:2:4) type B1 using 20mm graded crushed stone aggregate as in chajjas complete all as specified and as directed by Engr-in-Charge.
M&L for Reinforced cement concrete (1:2:4) type B1 as in slabs supported on walls, beams and columns in floors, roofs, landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engr-in-Charge.
M&L for Form work to soffits of suspended slab such as roof slab, floor slab etc n exc 200 mm thick rough finished surface of concrete slab complete all as specified and as directed by Engr-in-Charge.
M&L for rough finished surfaces if concreter formwork to sides and soffits if floor or roof beams haunching girder bressummer chajja shelves including supports complete all as specified and as directed by Engr-in-Charge.
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
S&F Mild steel bars 5mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (un reinforced) in ground floors and pavings exc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engr-in-Charge.
M&L for 75mm thick cement concrete (1:2:4) type-B2 using 40mm graded stone aggregate as in path/plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by Engr-in-Charge.
M&L for factory made vibro compacted cement concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100mm thickness, M-50 grade With grey cement and pigment complete all as specified and as directed by Engr-in-Charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-Charge.
M&L for cement concrete 100 mm thick (1:4:8) type D2 using 40mm graded stone aggregate complete all as specified and directed by Eng-in-charge.
M&L for cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimeter in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and as directed by Engr-in-Charge.
M&L for forming contraction (Dummy) joints 65mm deep X 10mm wide, filled with Grade 'A' sealing compound complete all as specified and as directed by Engr-in-Charge.
M&L for 25mm thick cement concrete flooring (1:2:4) type B1 using 20 mm graded stone aggregate finished even and fair complete all as specified and as directed by Engr-in-Charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick (minimum size 55 cms x 55 cms) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing complete all as specified and as directed by Engr-in-Charge.
M&L for Screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and as directed by Engr-in-Charge.
M&L for machine cut kota stone slabs as in vertical surfaces such as risers of steps 20-25 mm thick over 15 mm thick rendering in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing also moulding edges complete all as specified and as directed by Engr-in-Charge.
Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and as directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Eng-in-charge.
S&F 0.56 mm Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and as directed by Engr-in-Charge.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engr-in-Charge.
Dismantling of wrought iron or Mild Steel work of any description complete all as specified and directed by EIC complete all as specified and directed by Eng-in-charge.
S&F roof trusses Fe 410-W (Gde E-250) quality -A (framed), trussed, purling, wind tie, crane gantries and rail and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engr-in-Charge.
M&L for false ceiling of approved (ISI marked) make with 4mm thick HPS board fixed to galvanised iron steel angled grid 600x600mm size suspended system fixed to MS framed work of approved make and section as specified in SSR Part I with suitable hook/fasteners and GI/aluminium suspenders not less than 3mm dia @ 1.00m C/C minimum. ceiling system is to be fixed in water level without any sag and dismantling old ceiling board with frame complete all as specified and as directed by Engr-in-Charge.
Cutting out cracks to V-section in existing roofs or terracing cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight) complete all as specified and as directed by Engr-in-Charge.
Dismantling of old brick tiles or terracing tiles, single layer on roofs complete all as specified and directed by Engr-in-Charge.
Demolition of existing mud in roofs of any thickness including plastering and leaping, whether full thickness removed or only a part there of, and removing of mud complete all as specified and directed by Engr-in-Charge.
Roughening the surfaces of old concrete roof surfaces by dismantling old tiles, mud phuska and old brick boulders, picking, sweeping clean and washing down with water to remove dust etc including removal of old treatment of any description and removing the debris to a distance of n.exc 50 cm away from plinth protection complete all as specified and as directed by Engr-in-Charge.
M&L for 10mm thick rendering in CM (1:4) using water proofing compound at the rate of 3% weight of cement over concrete surfaces complete all as specified and as directed by Engr-in-Charge.
M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (wt not less than 150 gms /Sqm ) land on primed surface by forced application complete all as specified and as directed by Engr-in-Charge.
Supply only water proofing compound complete all as specified and as directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as in roof, kerbs, or mud stops rounded or chamfered on edges complete all as specified and as directed by Engr-in-Charge.
Disconnecting existing tanks exc 250 & n exc 500, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position complete all as specified and as directed by Engr-in-Charge. Note: Cleaning, repairing etc shall be measured separately.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
M&L for 25mm thick cement concrete flooring (1:2:4) type B1 using 20 mm graded stone aggregate finished even and fair complete all as specified and directed by Engr-in-Charge.
M&L for Screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and as directed by Engr-in-Charge.
M&L for Non-skid joint free ceramic coloured printed tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 10 mm thick in CM (1:3) finished even and fair as on brick or concrete surfaces for laying wall tiles complete all as specified and as directed by Engr-in-Charge.
M&L for colour joint free Glazed ceramic tiles in vertical surface 350x250x7mm/ 450x350x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed by Engr-in-Charge.
M&L for Dark Shade Vitrified ceramic tiles 10 mm thick (Square/rectangular) polished area of each tiles not exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement complete all as specified and as directed by Engr-in-Charge.
Taking down/out split AC 1.5 / 2 TR capacity of any make, from existing position, transporting and refixing at the new location including gas charging & fixing complete unit with gitties/ fastener, cutting wall / concrete including arrangement of T&P for laying copper tubing, brazing work, making necessary connections to make it functional complete all as specified and as directed by Engr-in-Charge. Note: (a) Gas charging if required shall be measured and paid separately. (b) Any additional copper tubing & parts required for shifting the unit is deemed to be included in quoted rates.
S&F air cooled split unit air conditioner electric driven (single phase) cooling capacity 4500 K cal per hour 2 Ton split units indoor/outdoor complete with cordless remote control unit and within built air ionizer and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 complete all as specified and as directed by Engr-in-Charge.
S&F MS stand factory made suitable for condensing unit of split type AC duly powder coated complete all as specified and as directed by Engr-in-Charge.Make- ISI marked
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and capacity 5 KVA complete all as specified and as directed by Engr-in-Charge.
S&F in complete for sheet metal enclosure with two pin socket, chain plug cover with one MCB SP of 32 Amp capacity with alignment 10 KA ‘C’ series including electric connection complete all as specified and as directed by Engr-in-Charge.
Taking out old unserviceable point wiring of any size any capacity and including concealed PVC rigid conduit with all fittings like switch, socket, fan, ceiling rose , holders etc and fixing accessories complete all as specified and as directed by Engr-in-Charge.
M&L for wiring with cable of size 1.5 Sqmm single core copper multistrand conductor including continuous1.5 Sqmm earth wire, using cable FRLS insulated(unsheathed) 1100 volts grade conforming to Is-694 drawn in to and including concealed PVC rigid conduit medium duty with all fittings and fixing accessories complete all as specified and as directed by Engr-in-Charge for followings:-
One light point controlled by one, one way switch
One 3 pin socket out let 5 amps independent
One 5 pin 5 amps socket point in same board with other switches.
One 3 pin socket out let 15 amps independent but with cable of size 4.0 Sqmm in point wiring and 4.0 Sqmm in continuous earth wire .
S&F in repairs of modular switch one way 6 amps 1 module complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of modular switch one way 16 amps 1 module complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of modular socket 2 in 1, 5 pin 6 amps 2 module complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of modular socket 2 in 1, 6 pin 6A/16 amp 2 module complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of modular fan regulator stepped type 120 watt 2 module complete all as specified and as directed by Engr-in-Charge.
S&F complete modular metal flush box 1 module including cutting of chassis and making good disturbed surfaces and rate deemed to be included in quoted rate complete all as specified and as directed by Engr-in-Charge.
S&F complete modular metal flush box 3 module including cutting of chassis and making good disturbed surfaces and rate deemed to be included in quoted rate complete all as specified and as directed by Engr-in-Charge.
S&F complete modular metal flush box 4 module including cutting of chassis and making good disturbed surfaces and rate deemed to be included in quoted rate complete all as specified and as directed by Engr-in-Charge.
S&F complete modular metal flush box 6 module including cutting of chassis and making good disturbed surfaces and rate deemed to be included in quoted rate complete all as specified and as directed by Engr-in-Charge.
S&F complete modular metal flush box 8 module including cutting of chassis and making good disturbed surfaces and rate deemed to be included in quoted rate complete all as specified and as directed by Engr-in-Charge.
S&F complete modular metal flush box 12 module including cutting of chassis and making good disturbed surfaces and rate deemed to be included in quoted rate complete all as specified and as directed by Engr-in-Charge.
S&F complete for modular white cover plate with frame 1 module complete all as specified and as directed by Engr-in-Charge.
S&F modular white cover plate with frame 3 module complete all as specified and as directed by Engr-in-Charge.
S&F modular white cover plate with frame 4 module complete all as specified and as directed by Engr-in-Charge.
S&F modular white cover plate with frame 6 module complete all as specified and as directed by Engr-in-Charge.
S&F modular white cover plate with frame 8 module complete all as specified and as directed by Engr-in-Charge.
S&F modular white cover plate with frame 12 module complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of ceiling rose surface Bakelite 3 terminal complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of PVC/Polycarbonate type Lamp holder, insulated body, with back plate for batten fittings complete all as specified and as directed by Engr-in-Charge.
M&L for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2x10 Sq mm and 1x 10 Sq mm as in continuous earth wire drawn into & including PVC conduit medium 20mm dia ISI marked complete with fittings and fixings accessories laid concealed complete all as specified and as directed by Engr-in-Charge.
M&L for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2x06 Sq mm and 1x 6 Sq mm as in continuous earth wire drawn into & including PVC casing caping not less than 25mm dia ISI marked complete with fittings and fixings accessories laid complete all as specified and as directed by Engr-in-Charge.
M&L for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2x16 Sq mm and 1x16 Sq mm as in continuous earth wire drawn into & including PVC casing caping not less than 25mm dia ISI marked complete with fittings and fixings accessories laid complete all as specified and as directed by Engr-in-Charge.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge. Make: Usha / Orient / CG
Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to ceiling fan complete and connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length complete all necessary arrangement of hanging of ceiling fan (GI Pipe hook etc) complete all as specified and directed by Engr-in-Charge.
S&F in repairs of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge. Make: Havells, Cat Part No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivalent of CG / Halonix
M&L for PVC exhaust fan of size 450 mm sweep, 1400 RPM single phase, single phase,230 Volt Ac 50 Hz with louver shutter / grill and connection complete all as specified and directed by Engr-in-Charge. Make: Usha / Orient / CG
S&F in repairs of LED Street light 35/36 Watt IP 65 complete all as specified and directed by Engr-in-Charge. Make: Havells, Cat Part No. ENDURACITYLITEPLATPLUSSL35WLED757SASY BOPC or equivalent of CG / Halonix
S&F in repairs of dist board, sheet steel, powder coated for MCCB DB s with copper bus bar, neutral link and earthing stud conforming to IS 13032/IS 8623 TPN vertical 6 ways for three phase out going including necessary connections complete all as specified and directed by Engr-in-Charge. Make: Indoasia, Cat Part No. : 811889 or equivalent in Havells / Standard
S&F in repairs of MCB dist board, sheet steel, phosphatised, powder printed with bus bar, neutral link, earth bar & din rail conforming to IS 13032/IS 8623 SPN dist board 08 ways double door complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of 4 pole MCCB 100 Amp 50 Hz, 415 Volt with rupturing capacity 25 KA complete all as specified and as directed by Engr-in-Charge. Make: Indoasia/ Havells/ Standard
S&F in repairs of MCB single pole 240 volts, C curve-10 ka 6 TO 32 Amp complete all as specified and as directed by Engr-in-Charge. Make: Indoasia/ Havells/ Standard
S&F in repairs of MCB single pole & neutral 240 volts, C curve-10 ka 40-63 Amp complete all as specified and as directed by Engr-in-Charge. Make: Indoasia/ Havells/ Standard
S&F in repairs of MCB single pole & neutral 240 volts, C curve-10 ka 32 Amp complete all as specified and as directed by Engr-in-Charge. Make: Indoasia/ Havells/ Standard
S&F in repairs of MCB dist board, sheet steel, phosphatised, powder printed without bus bar conforming to IS 13032/IS 8623 SPN dist board 02 ways single door complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of earthling with galvanized mild steel earth plate electrode 600x600x6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5mtr (B.G.L.) and connected to galvanized iron earth strip 32x6mm by means of bolts, nuts, check nuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 12mm round bar, including necessary excavation &earth work in any type of soil. 20mm dia med gde galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm dia bore, light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead wire protection common salt, charcoal etc complete all as shown in EP No 3 of SSR Part 1 and testing on completion.
M/s R P Enterprises
SACHDEVA ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .