Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹11.2 L+₹41,049.50 (3.80%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹11.3 L+₹47,588.50 (4.41%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹11.3 L+₹50,936 (4.72%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹11.3 L+₹54,620.50 (5.06%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
20 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN-913867
REPAIR AND MAINTENANCE OF EXTERNAL LT ELECTRIFICATION AND CONNECTED WORKS AT RHENOCK AND RONGLI UNDER GE 867 EWS
2022_MES_565970_1
GE/867/TOKEN/61 OF 2022-2023
Open Tender
Civil Works
Item Wise
240 days
KALIMPONG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹20,000
2 Mar 2023
29 Nov 2022
22 Dec 2022
29 Nov 2022
20 Dec 2022
13 Dec 2022
29 Nov 2022 - 11 Dec 2022
Amount
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge.
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
M&L for sand cushioning to U/G cable in layers in trenches complete all as specified and directed. Note :- Only Puned layers shall be measured for payment
M&L for well burnt bricks, sub class 'B' bricks of size 250mmx125mmx75mm, best quality locally available laid flat dry in trenches for cable protection complete all as specified and as directed.
Dismantling / Taking out Unserviceable LT cables of size 50 sqmm to 120 sqmm from any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and directed by Engineer-in-Charge.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of Size of 70 Sqmm 3.5 core as required at site, Make : MESCAB/HAVELLS/POLYCAB/KEI/GLOSTER or equivalent as approved by GE
All as per Item No 7 above but Size of 50 Sqmm 3.5 core all as specified an directed.
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and directed by Engineer-in-Charge.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel ofSize of 35 Sqmm 3.5 core as required at site, Make : MESCAB/HAVELLS/POLYCAB/KEI/GLOSTER or equivalent as approved by GE.
All as per Item No 10 above but Size of 25 Sqmm 3.5/4 core all as specified an directed.
All as per Item No 10 above but Size of 16 Sqmm 4 core all as specified an directed.
All as per Item No 10 above but Size of 10 Sqmm 2 core all as specified an directed.
Dismantling / Taking out Unserviceable GI pipe of any size removing material from site complete all as specified and directed by Engineer-in-Charge.
M & L GI tube light grade for passing through cables under the floor, along the wall or along the pole of following bore dia and fixed to the poles/walls with 40 mm bore of MS clamps and nut and botls/washers etc including taking down old GI tubing complete all as specified an directed.
M & L GI tube light grade for passing through cables under the floor, along the wall or along the pole of following bore dia and fixed to the poles/walls with 25 mm bore of MS clamps and nut and botls/washers etc including taking down old GI tubing complete all as specified an directed.
Dismantiling/taking out old unserviceable LT insulator any size, any type from poles all as specified and directed.
S & F for pin type insulator porcelain vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 100mm height, 65mm dia for 1100 Volt grade complete all as specified and directed.
S & F for Sackle type insulator porcelain vitreous white/ brown or green including one galvanised mild steel straps of size 31 x 5 mm, washers insulator bolt of 14 mm dia and nuts complete of size 100 mm hight and 115mm dia of working pressure 1100 volts grade complete all as specified and directed.
S&F in repair cable route marker of size 100 mm x 100 mm x 5mm thick with GI plate with inspection threon bolted / welded to 35 mm x 35mm x6 mm angle iron 60 cm long and fixing the same in ground as required for LT cable all as specified and directed by Engineer-incharge.
S&F in repairs Busbar Chambers 8 way 100 Amps outdoor type (IP 65/66) pole mounted including provision of fixing on pole by means of suitable size of clamps with nut and bolts OR provision of fixing on 50 x 50 x 6mm thick angle iron frame work upto height of 0.9mtr above ground level including necessary connection completed all as specified and as directed. Make Havells cat part No IHBC010004 or equivalent make of SMC/Hensel.
Trimming of tree branches which touches the LT OH lines and 2.5 Mtr away from centre line of LT OH lines span not exceeding 60 Mtr distance between poles by using neccessory T&P items and depositing the tree branches/leaves at 30 Mtrs away from the site all as specified and directed. Note -Any number of tree branches cut in one span will be measured as one lenght of payment.
M & L for Plain Cement Concrete (1:3:6) mix type C2 (using 40 mm graded stone aggregate) in foundation, filling and mass-concrete etc for pole, stay etc all as specified and directed by Engr-incharge.
M & L for Plain Cement Concrete (1:2:4) type B1 (using 20 mm graded stone aggregae) as in copping including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement all as specified and directed by Engr-incharge.
Supply and fixing of earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried on ground or drawn in conduit pipe or fixed to poles in repairs or any other indicated situation for the loop earthing etc. as required of size 32 x 6 mm galvanized iron strip complete all as directed.
Dismantiling and taking down unserviceable ACSR having more than two joints of any size and removing from site of work all as directed by engr in charge
M&L for aluminium conductor steel reinforced ( ACSR ) including binding wires of suitable sizes and suitable conductors / parallel groove clamp Etc. other jointing materials for over head lines complete all as specified and directed by Engineer-in charge.
M&L earthing complete with galvanized steel earth plate electrode 600mmX600mmX6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and connected to and including using 32 x 6 mm galvanized MS strip wire upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES schedule Part-I, and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe 40 mm dia, light grade 7.5 mtr long for protection of earth lead upto test point etc including earth work, excavation and testing complete all as specified and as directed. Note : (a) Length of earthig connection incl GI strip and protection pipe more than 7.5 Mtr will be measured separately. (b) Contractor should conduct necessary test such as Earth continuity, earth resistance test in presence of JE (E/M)/Engr-incharge.
Description all as per item No. 23.00 above but with GI conductor 4 mm dia as earth electrode and 15mm dia protection pipe all as specified and directed
Dismantling / Taking down unsv Galvanized Steel earth wire/ cradle guard any size as directed by Engr-in-charge.
S & F galvanized steel earth wire 3.15 or 4 mm dia for earth continuity conductor including binding and connecting to earth test poit etc, including taking down existing earth wire complete all as specified and direced by Engr-inchargeall as specified and as directed
S & F Galvanised stay strand, 7/4mm as stay wire including binding etc, complete all as specified and directed by Engr-incharge
Dismantling / Taking down of cross arms of channel or sections etc complete setting aside for reuse (serviceable one) or removing from site of work all as directed and as specified.
M & L cross arms, bracings, supports clamps, stay clamps etc fabricated from structural steel sections including nuts, bolts, washers welding bending cold or hot drilling holes for bolts any size of shape and including hooks & clamps for aerial bunch cable as indicated and directed and inclusive of 2 coats of aluminium painting over a coat of red oxide primer all as specified and as directed.
Dismantling / Taking down old unsv stay assembly complete all as specified and as directed by engineer in charge.
M & L stay assembly with accessories as shown in Elect plate No- 01 of MES schedule Part-I complete with diameter of rod 16 mm all as specified and directed. Note - Loop type insulator , stay clamps , excavation and concrete will be measured and paid separately .
Supply & Fixing in replacement loop type insulator vitreous porcelain white, brown, or green of size 65 X 90 mm clearance of hole 16 mm all as specified and directed.
M&L for painting of steel tubular pole of any size , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level and numbering of size 70mmx40mm by using stencil to the pole with black synthetic enemal paint (1st grade ) complete all as specified and directed.
Restringing of existing LT overhead line including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumpher and connections and reconnecting after tightning of conductor incl replacement of all jumpers all as directed by Engr -incharge. Note - (a) Any run of conductor in between two span in LT lines shall be measured as one lenght for payment purpose. (b) ACSR conductor will be measured and paid separately.
M&L for Repairing of LT panel by means of replace the hinge and locking arrangement of the existing panel, tightening the cable with bus bar by means of suitable lugs, replacement of suitable indicator with colour all as specified and as directed by Engr-incharge.
S & F in repairs MCCB 4 pole 160 Amps, with thermal release range 70-100% and magnetic setting adjustable, breaking capacity 36 KA completed all as specified and as directed by Engr-incharge
S & F in replacement of existing type MCCBs of 100 Amps, 415Volt, breaking capacity 25KA, 4 Pole, completed all as specified and as directed by Engr-incharge
Material and labour for spray painting to outdoor/Indoor type double door LT panels/Fedder pillar box incl angle iron stand with synthetic enamel paint after cleaning the surface thouroughly with scrapper including protecting/cleaning of cables, wiring and other non painted parts complete all as specified and as directed by Engr-in-charge.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from panel/trench by excavation) against item Ser No 7.01 to 7.02 above, for outdoor termination Straight through tubular sleeve version type joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 Sqmm all as specified and directed.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from panel/trench by excavation) against item Ser No 9.01 & 9.02 above, for outdoor termination Straight through tubular sleeve version type joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 Sqmm all as specified and directed.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from panel/trench by excavation) against item Ser No 9.03 above, for outdoor termination Straight through tubular sleeve version type joint complete with jointing materials and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16 Sqmm all as specified and directed.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from panel/trench by excavation) against item Ser No 9.40 & 9.50 above, for outdoor termination Straight through tubular sleeve version type joint complete with jointing materials and accessories suitable for 2.0 core XLPE armoured aluminium conductor cable of size upto 16 Sqmm all as specified and directed.
M & L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, including taking out old unserviceable rusted out danger plate all as specified and directed.
M & L for DK Thermoplastic cable junction boxes in repairs of make Sintex, product code GSJB-3126, IP 65 of size 270x225x135mm of metric knockouts for cable entry, weather proof for indoor/outdoor installation with and including glands/insulators and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 2/4 core and fixed to wall/Steel Poles by means of suitable size of clamps with nut and bolts complete including taking down existing existing junction box all as specified and directed by Engineer-in-Charge. NOTE: Make of Junction box shall be Sintex/Hensel or equivalent as approved by GE
Supplied and spreding graded coarse aggregae 40 mm nominal size all around the structure yard area all as directed by Engrs-in charge
Taking our old unserviceable / fauly cable of any size /serviceable connecting cable of any size/grade cross sectional area up to 10 sqmm to 50 sqmm 3.5 core including brick protection for repairs/replacement etc and removing materials from site of work complete all as specifed and as directed
All item No 47 here in above but 70 sqmm to 120 sqmm 3.5 core or 4 Core LT UG cable all as specified and directed Note :- For Item No 47 & 48 (a) Relaying of cable after rectifying the fault, earth work shall be measured and paid separately under respective items (b) Serviceable bricks/pipe retireved shall be stacked separately for reuse and cost of the same is inclusive in the item rate. (c) Excavation and necessary earthwork shall ve measured and paid separtely under relevent item.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
DEDUCTED AMOUNT OF SCHEDULE OF CREDIT
JAYSHREE CONCERN
G K SUTHAR
RAJU TAMANG
MS BRAHMA CONSTRUCTION
PRASAD PRADHAN AND SON
MS MAYA PRAKASH GOEL AND SONS
S K ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .