Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹34.3 L+₹89,760 (2.69%)Rejected-Finance | L2 | Rejected-Finance Other Than Lowest | |
| 3 | L3₹34.8 L+₹1.4 L (4.09%)Rejected-Finance | L3 | Rejected-Finance Other Than Lowest | |
| 4 | L4₹36.7 L+₹3.3 L (9.88%)Rejected-Finance | L4 | Rejected-Finance Other Than Lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
1 Jul 2023, 6:00 pmClosed
Garrison Engineer Brichgunj
Garrison Engineer Brichgunj
REPAIR AND MAINTENANCE PROTHRAPUR FILTERATION PLANT, 500/400/300MM PIPE LINE, CLEANING OF OH TANKS AND UG SUMPS UNDER GE BRICHGUNJ
2023_MES_594085_2
8348A
Open Tender
Miscellaneous Works
Item Rate
330 days
Brichgunj
Class d cat a(ii )
8 documents required · 8 mandatory
₹500
Garrison Engineer Brichgunj
₹60,000
Yes
11 Aug 2023
12 Jun 2023
3 Jul 2023
12 Jun 2023
1 Jul 2023
19 Jun 2023
12 Jun 2023 - 17 Jun 2023
Amount
M&L for cleaning of service tanks of the capacity as mentioned below on roof top of bldgs upto forth storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with bleaching powder, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white/black bold letter such as "TANK CLEANED ON" (date), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours. (ii) Contractor shall maintain a register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted to JE E/M alongwith RAR. (iii) Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv) All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
PVC tank upto 300 litres
PVC tank upto 500 litres
PVC tank upto 1000 litres
PVC tank upto 2000 litres
PVC tank upto 5000 litres
S&F in repair PVC tank cover top for water storage tanks suitable for 200/300 ltrs capacity as per existing colour complete all as specified and as directed.
All as per Item Sl Item No 02 here-in-before but of size 500/1000 ltrs capacity
All as per Item Sl Item No 02 here-in-before but of size 2000/5000 ltrs capacity
S&F in replacement of Rotational moulded polyetheylene (HDPE) double layered ISI marked Water Tanks of 200 Ltr capacity Cylindrical & Vertical Type, ISI marked, hoisted and fixed in position with PVC cover including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
All as per Item Ser Item No 03 here-in-before but of size 500 ltrs capacity
All as per Item Ser Item No 03 here-in-before but but of size 1000 ltrs capacity
All as per Item Ser Item No 03 here-in-before but but of size 2000 ltrs capacity
S & F in replacement 20mm dia Ball valves (Float Valve) high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and as directed. (Minimum weight 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms)
All as per Item Ser Item No 4 here-in-before but 25 mm dia
All as per Item Ser Item No 4 here-in-before but 40 mm dia
S & F Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete after dismantling and taking out the existing unserviceable Gun metal gate valve of size 20 mm all as specified and as directed by Engr-in-Charge. Make : NMV, ZOLOTO, LEADER
All as per Item Ser Item No 5 here-in-before but of size 25 mm.
All as per Item Ser Item No 5 here-in-before but of size 40 mm.
All as per Item Ser Item No 5 here-in-before but of size 50mm.
M&L in repair/rectification of blockage to water supply distribution GI lines of size 20mm dia to 25 mm dia by necessary excavation, returning /filling as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement including replacement of all fittings such as GI union ,socket, nipple etc as required complete all as directed.
All as per item No 6 above but size 40 mm dia to 50 mm dia
All as per item No 6 above but size 80 mm dia
Material and labour for detecting leakage in GI Water Supply GI Lines of size 20mm dia to 25 mm dia by necessary excavation, returning /filling as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement including replacement of all fittings such as GI union ,socket, nipple etc as required complete all as directed.
All as per item No 7 above but size 50/40 mm bore
All as per item No 7 above but size 80 mm bore
S& F in replacement steel water tubes medium grade (ISI marked) galvanised with all fittings and fixed to walls or laid on floor or in ceilings of size 20 mm bore pipe alongwith all fittings as per site reqirement including taking out of old pipelines complete all as specified and as directed by Engr-in-Charge. Make : Tata/Jindal/Bansal
All as per item No 8 above but of size 25 mm dia.
All as per item No 8 above but of size 40 mm dia.
M&L for Cutting Bittumen Road Hard top at site as required for Laying of DI Pipe line and making good of disturbed surface as per existing top with 20/40mm graded stone aggregate and bitumen layer etc after repair work complete all as specified and as directed.
Supply, lay in trenches, connect, joint, test and commission of 500 mm dia Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" with Socket and Spigot ends conforming to IS-8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside mortar lining and black bitumen external coating complete including taking down of existing unserviceable pipes all as specified and as directed.
All as per Item Ser Item No 06 here-in-before but of size 400 mm bore
All as per Item Ser Item No 06 here-in-before but of size 300 mm bore
All as per Item Ser Item No 06 here-in-before but of size 250 mm bore
Supplying, fixing and testing of CI, heavy duty, Specials of any size, radius and length confirming to IS - 1538 Part - I to XXIII: 1976 such as bends [any type, radius and angle], tapers any type [straight, bend, increasing, decreasing or double socket etc], sockets, tail pieces, connecting pieces, tee pieces, single branch, "Y" junction, double branch, cross, [all sockets or socket and spigot or Flanged], collars, caps and plugs, ( required for shape as per site )adopters etc suitable for CI Spigot and Socket or Flanged pressure pipes complete all as specified and as directed.
All as per item No 11 here in before but DI fittings of any size complete all as specified and directed
M&L for detecting leakage in DI pressure pipes of 400/500 mm bore in any location, any depth including necessary earthwork excavation and repairing and arresting leakage by providing jointing material, flanged clamps, nuts, washers & bolts etc. complete all as specified and as directed.
All as per Item Ser Item No 12 here-in-before but of size 250/300 mm bore
All as per Item Ser Item No 12 here-in-before but of size 200 mm bore
S&F in replacement sluice valve, cast iron body, stainless steel spindle, gun metal rings including wheel for operation, flanged and drilled of size 400 mm dia, confirming to IS - 14846, class PN -1.6, long body type including all jointing materials, bolts, nuts, washer complete all as specified and as directed.
All as per Item Ser Item No 13 here-in-before but of size 300 mm dia
All as per Item Ser Item No 13 here-in-before but of size 250 mm dia
All as per Item Ser Item No 13 here-in-before but of size 200 mm dia
All as per Item Ser Item No 13 here-in-before but of size 150 mm dia
All as per Item Ser Item No 13 here-in-before but of size 100 mm dia
M&L taking out sluice valve of 100mm bore, repairing and refixing the same after re-facing, grinding the valve check nut, Spindle etc. including jointing materials complete all as specified and directed.
All as per Item Sl No 14 here-in-before but of size 150 mm bore
All as per Item Sl No 14 here-in-before but of size 200 mm bore
All as per Item Sl No 14 here-in-before but of size 250 mm bore
All as per Item Sl No 14 here-in-before but of size 300 mm bore
All as per Item Sl No 14 here-in-before but of size 400 mm bore
M&L for repairs to air release valve, of 150 mm bore of pipe and refixing the same after replacing the unserviceable HDPE float, nuts, bolts and jointing materials complete all as specified and directed.
All as per Item Ser Item No 15 here-in-before but of size 200 mm bore
M&L for run lead joint confirming to IS specifications for cast iron pressure pipes of 150/200 mm bore complete all as specified and as directed.
All as per Item Ser Item No 12 here-in-before but of size 250/300 mm bore
All as per Item Ser Item No 12 here-in-before but of size 400/500 mm bore
Collect the sample of water of 5 litres each from user end, after cleaning of UG Sumps or OH Tanks or RCC/ PVC tanks or treated water of STP and sending it same day at Govt approved lab for testing of water as per IS in a cleaned container and necessary reports will be submitted to GE Birchgunj complete all as directed by Engr in Charge.
M&L for repairs to 400mm bore non- return valves by opening valve, cleaning the gates with wire brush, removing deposited scales/ foreign materials, rubbing the seat with emery paper and repalcing unserviceable gasket and worn out parts etc, and refixing back to original position, complete all as specified and as directed
All as per Item Ser Item No 18 here-in-before but of size 200 mm bore
Excavation and earth work in mud/hard soil etc by using machinary/labour to any length to attend pipe line breakdown as per site conditions and forming bund with excavated soil to avoid water entering into the working area including pumping/bailing out water by using portable diesel engine driven pump set including the following complete all as specified and as directed :- (i) Cutting of unserviceable CI/DI pipe of size 300/400/500 mm dia after thorough inspection for the damage including bailing out water using portable pump set. (ii) Taking out damaged/ unserviceable pipe after removing from rubber tyton joint/burning out lead joints at both ends & replacing new 300/400/500 mm dia DI pipe line in lieu of existing in to trenches using machinary / labour as required complete all as directed by Engineer-in-Charge. (iii) Transportation of DI pipe / fittings of size 300/400/500 mm dia from Prothrapur Pump house to work site and cutting the pipe to required length to suit site conditions. (iv) Jointing pipe by using rubber tyton rings 300/400/500mm dia to the corresponding socket and spigot ends of the existing pipe line after aligning the pipe line as per site condition, inserting the CI collar of size 300/400/500 mm dia, complete all as directed by Engineer-in-Charge. (v) Making run lead joints in CI collar 300/400/500 mm dia or in any other specials of any size and any type, caulking of joints and testing for leakages if any, complete all as specified and as directed by Engineer-in-Charge. (vi) Returning filling in including removal of surplus mud/excavated materials with the help of earthmoving machinery (Hitachi), complete all as specified and as directed by Engineer-in-Charge.
M&L for excavation and earth work in hard soil by using machinary/labour to any length to clearing blockage of 250 mm dia pipe line as per site conditions including the following complete all as specified and as directed :- (i) Cutting/Taking out of unserviceable DI pipe of size 250 mm dia and refixing the pipeline with rubber tyton joint/lead joints (ii) Taking out damaged/ unserviceable pipe after removing from rubber tyton joint/burning out lead joints at both ends & replacing new 250 mm dia DI pipe line using machinary / labour. (iii) Jointing pipe by using rubber tyton rings 250 dia to the corresponding socket and spigot ends of the existing pipe line after aligning the pipe line, inserting the CI collar of size 250 mm dia, complete all as directed (v) Making run lead joints in CI collar 250 mm dia or in any other specials of any size and any type, caulking of joints and testing for leakages if any, complete all as specified and as directed
Note for item No 19.00 & 20.00 :- (a) DI pipe and fittings of any dia shall be measured and paid separately under relevant item here in before. (b) Cost of tools & plants as required for work & transportation is deemed to be included in the unit rate quoted. (c) The Contractor shall take due care while executing the work (i.e., sepecially taking out old existing pipe line and laying new pipe line). Any damage to the existing services (i.e electrical cable,telephone cable,water supply pipe line and road etc) during execution of work shall be repaired immediatly and cost of the same is deemed to be included in the quoted rates)
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out for taking out or laying of pipes / cable of any size in Soft/ loose soil complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers n.exc. 25cm in any type of soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
M&L for preparing old painted or untreated exposed surfaces of CI / DI Pipes of any size (upto 500 mm bore), Valve Chamber Covers, clarifloculators, pump motors, railing any type and applying one coat of black coloured weather proof synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for construction of valve chamber of size 1200mmx1200mm x1200mm internal size suitable for sluice valve with PCC 1:3:6 type (C2) (using 40mm graded aggregate) for foundation, one hollow block masonry wall in cement mortar (1:4), 40mm thick PCC (1:2:4) type B1 (using 20mm graded aggregate) coping, rendering in CM 1:4, 15mm thick including provision of mild steel sheet cover of 3mm thick on 40x40x6 mm angle iron frame work emmbedded in concrete with suitable hinges and locking arrangements including two coats of black synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary excavation earth work on any type of soil etc. including removal of surplus soil and rubbish not exceeding 50m distance, including demolition of old valve chambers complete all as specified and as directed.
All as per Item Ser Item No 25 here-in-before but valve chamber of size 900 x 900x 900mm
M&L for dewtering complete trenches manually for repairing joints by cocking and inserting spurn yarn and Run lead joint, making good/ leakless the joint for pipes of sizes 80 mm dia complete all as specified and directed :-
All as per item No 26 here in before but 100 mm bore .
All as per item No 26 here in before but 150 mm bore .
All as per item No 26 here in before but 200 mm bore .
All as per item No 26 here in before but 250 mm bore .
All as per item No 26 here in before but 300 mm bore .
S&F in replacement of Gun Metal Foot valve of 200 mm bore including necessary bolts and nuts complete all as specified and as directed
All as per item No 27 here in before but 150 mm bore .
All as per item No 27 here in before but 100 mm bore .
All as per item No 27 here in before but 80 mm bore .
M&L for replacement of butterfly valve heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for following bore pipe including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unsv butterfly valve including making arrangement for safe working all as specified and directed. (a) 200 mm dia
(b) 150 mm dia
Supply only grass and weeds killer chemical of make Roundup (01 litre pack) all as specified and directed.
Preparation of old surface shall include brooming down or steel wire brushing & scrapping down and white washing two coat on surface of UG Sump and installation all as specified and as specified and as directed
Supply only PH test Kit including all testing materials
Supply only Ortho Tolidine solution in 500ml bottle pack.
Supply only residual chlorine test kit as per sample as approved by GE Make : RMCO or equivalent
Supply Only Auto Conductivity TDS Temp Meter LB-950, Accuracy +/- 3% F.S
M&L for servicing of JAR test apparatus (flocuculator) and made it serviceable by replacing any parts all as specified and as directed. Note : Rate deemed to be included replacement cost spare parts if necessary all as specified and as directed
M&L for servicing of Alum gear box by replacing gear motor pump set of capacity 0.75 kw, 3 ph, 600 rpm and and all unserviceable parts such as agitator with mechanism support & replace with new parts and rusted bolt nuts complete all as specified and directed.
All as per item No 36 here in before but flux mixture system by replacing gear motor pump set capacity 1.5 kw, 3 ph, complete all as specified and directed
M&L for servicing of Lime gear box by replacing gear motor pump set capacity 1.5 kw, 3 ph, and all unserviceable parts suach as oil seal, gear oil coupling bush, greasing on chain & chian spocket, fixing aluminium driven paddle agitator with mechanism support, drum vertical shaft & replace with new parts and rusted bolt nuts all as specified and directed
M&L in replacement of PCC 1:3:6 type C1 (using 20mm graded aggregate) as in coping, foundation, support of DI Pipe (including necessary form work) complete, all as specified and as directed.
M&L for PCC (1:2:4) Type B-2, using 40 mm graded stone aggregate as in foundation, filling mass concrete, for supporting / encasing of CI / DI Pipes of any description, valve chambers, Pilasters, Columns, Pillars, Buttresses, Boundary Pillars and Posts including necessary form work etc complete all as specified and directed.
S&F in replacement automatic star delta starter ML4, 415V for the pump motor set of capacity 75 HP complete all as specified and as directed. Make: L&T or equivalent
M&L for disconnecting and removing the unsv monoblock pump set and S & F, install new induction mono block pumpset complete with head range 24-36M, disch 12 LPS alongwith with suitable starter and connecting up complete all as specified and directed.
All as per Item Sl No 42 here-in-before but head range 24-39M, disch 7.58 / 3.3 LPS complete all as specified and directed.
S&F in replacement of DOL starter 415 volt including testing for motor capacity of 7.5 HP complete all as specified and as directed. Make: L&T or equivalent in BCH
All as per item No. 44 here-in-before but 3 - 5 HP L & T /BCH
M & L in replacement of gland packing 8mm/10mm/12.5mm dia / thick for sluice valve / pumps of different sizes and applying grease and changing rusted nut bolts washer etc complete all as specified and as directed at site complete all as specified and as directed.
Dismantling of motor pump sets, removing electrical connections for servicing /rewinding /replacement of bearings etc, refixing the motor pumpset in original position including making proper allignment and necessary electrical connections, testing of 25 HP high pressure Pump Set complete all as specified and as directed
M&L for taking out old burnt winding of stator and rotor, cleaning the slots and re-winding of motor with suitable gauge super enamelled copper winding wire, varnishing, insulation, ovening, greasing of 25 HP motor including complete all as specified and as directed.
S&F the following spare parts of suitable for 25 HP High Pressure Pump complete all as directed. Make : SIEMENS (a) SS Bush
(b) SS Diffuser
(c) SS Impeller
S&F in replacement Add on blocks fpr MNX contractor complete all as specified and as directed .
S&F in repairs power contactor 415 volts, 75 Amps, 3 pole including auxiliary contact with Add on block MNX A1 complete all as specified and as directed . [Cat No. MNX 75 of Make: L&T or equivalent in Legrand/ Schneider]
All as per Item No. 50 here-in-before, but capacity 50 Amps.
Supply only High performance polyurea grease for electric motors & High speed ball bearings at medium and high temperatures all as specified and as directed
NOTES :- 1. The contractor or his authorised representative shall report to concered JE E/M or Engineer-in-Charge at 0900 hours daily on all working days to receive order/instructions of the work or regular complaints. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in -Charge / JE Concered. 2. In case the contractor fails to attend/rectify the defects within the above time limit, penalty will the imposed as Rs 1500/- per day in case of complaints/jobs.
M/s Karbhagam Sales Agency
KML CONSTRUCTION
M/S TANISHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .