| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹19.7 L+₹1.1 L (5.78%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹19.8 L+₹1.2 L (6.56%)Rejected-AOC RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹20.8 L+₹2.2 L (12.1%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹20.8 L+₹2.2 L (12.1%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
6 Jun 2023, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon
CA NO. GE AF NO.1/GUR-29/2023-24 REPAIR / MAINT OF DG SETS, SERVICE MAIN CABLE, EARTHING AND OTHER MISC E/M WORKS AT AF STATION PALAM UNDER GE (AF) GURGAON NO 1.
2023_MES_595363_1
GE AF No 1/GUR-29/2023-29
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹80,000
Yes
23 Jun 2023
15 May 2023
8 Jun 2023
15 May 2023
6 Jun 2023
30 May 2023
Amount
Inspection, maintenance, carrying out and comprehensive maintenance of 400 KVA DG set and servicing of DG sets including Alternator, Non AMF/AMF panels of connected DG sets for routine check up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning and carryingout the checking of engine oil level , oil bath cleaner oil level, draining sediments from fuel tank, checking of pre cleaner dust pan, air cleaner restriction, coolant level, record oil pressure, checking / tightening of all bolts/ nuts of engine and alternator, checking of AVM pads, diaphram coupling, air piping, cleaning of oil bath air cleaner tray screen,check / adjust belts, checking battery volatge, water level and apply jelly on terminals, checking fan hub/ air blower hub and water pumps, cleaning of electrical connections with CTC solution, checking of safety controls, cleaning of cooling system, cleaning of engine and radiator assembly, cleaning of roof, floor of the DG set room complete all as specified.
Note: The Comprehensive maintenance includes carrying out preventive maintenance including replacing minor unserviceable / worn out spares to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, distilled water, electrolyte, etc. All other spares will be measured and paid seperately as supply only under relevant items of this schedule, Contractor has to attend the break down at any time and place during the contract period. General maintenance is indicative only contractor has to carryout other necessary maintenance task also as required and directed by Engineer in Charge. Note : Break down to be attend and rectify within 3 hours of report failing which penality @ Rs. 1000/- per hour to be charged for delay.
All as per item no. 1 here in before but DG set of capacity 250KVA
All as per item no. 1 here in before but DG set of capacity 200KVA
All as per item no. 1 here in before but DG set of capacity 82.5KVA
All as per item no. 1 here in before but DG set of capacity 62.5KVA
All as per item no. 1 here in before but DG set of capacity 25KVA/30KVA/40KVA
Suppy only the following spares parts of existing make and model complete all as specified and directed :-
Supply of oil filter for the DG set of capacity 400 KVA
Supply of oil filter for the DG set of capacity 250 KVA
Supply of oil filter for the DG set of capacity 200 KVA
Supply of oil filter for the DG set of capacity 82.5 KVA
Supply of oil filter for the DG set of capacity 62.5 KVA
Supply of oil filter for the DG set of capacity 25KVA/30KVA/40KVA
Supply of fuel filter for the DG set of capacity 400 KVA
Supply of fuel filter for the DG set of capacity 250 KVA
Supply of fuel filter for the DG set of capacity 200 KVA
Supply of fuel filter for the DG set of capacity 82.5 KVA
Supply of fuel filter for the DG set of capacity 62.5 KVA
Supply of fuel filter for the DG set of capacity 25KVA/30KVA/40KVA
M & L for repair and reconditioning of battery charge alternator kirloskar/ cummins make including taking out the defective alternator from 20 KVA / 30 KVA / 32.5 KVA / 62.5 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
M & L for repair and reconditioning of battery charge alternator kirloskar/cummins make including taking out the defective alternator from 82.5 KVA / 200 KVA / 250 KVA /400 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
Supply only coolant for radiator suitable for DG set 20/32.5/50/82.5/100/200/250/500 KVA Make- Cummins/ Kirloskar/ Ashok Leyland green,all as per manufacturers recommendations
M & L for supply , fixing in replacment of fan belt set of 2 nos in 200/250 KVA DG set cummins part no. 178611 all as specified and directed by Engineer-in-charge
M & L for supply, fixing in replacment of belt water pump ( set ) in 200/250 KVA DG set cummins part no.200328 all as specified and directed by Engineer-in-charge
S & Fixing in repairs High water temperature trip safety control part no. 3408624 make Cummins in DG set and connecting with DG set system of 200 KVA/250 KVA all as specifiied and directed by Engineer-in-charge
S & Fixing in repairs Low lub oil pressure safety control part no. (3408607) 3408614 make Cummins in DG set and connecting with DG set system of 200 KVA/250 KVA all as directed by Engineer-in-Charge
M & L for replacement of lead Acid type battery 12 volt 180 AH including initial charging as specified complete. Make: EXIDE/AMRON/SF
M & L for replacement of lead Acid type battery 12 volt 150 AH including initial charging as specified complete. Make: EXIDE/AMRON/SF
M & L for replacement of lead Acid type battery 12 volt 130 AH including initial charging as specified complete. Make: EXIDE/AMRON/SF
M & L for replacement of battery brass terminal with nuts and bolts complete all as specified and directed.
M & L for replacement of battery lead 1.50 Mtr long consisting of multistranded copper conductor PVC insulated single core cable of 50 Sqmm size connected with 1 No battery terminal clamp at one end and copper lug at other end all as directed.
M & L for replacement of battery lead 1.50 Mtr long consisting of multistranded copper conductor PVC insulated single core cable of 35 Sqmm size connected with 1 No battery terminal clamp at one end and copper lug at other end all as directed.
M & L for supply, fixing and testing DG set stop solenoid switch in 25/30/45/62.5/82.5 KVA by taking out the defective switch from the DG set, replacing by new and aligning, connecting with circuit, starting and testing all specified and directed by Engineer-in-charge
M & L for supply, fixing in repair coil electrical in STC control valve under make Cummins part no.4963341 in 250 KVA DG set as specified and directed by Engineer-in-charge
M & L for supply, fixing in repairs phase indicator lamps R Y B LED type
M & L for supply , fixing in repairs to Lub oil pressure transducer make Cummins Part no.3392445 in 250 / 200 KVA DG set and connecting with DG set system all as directed by Engineer-in-Charge
M & L for supply, fixing in repair shutdown valve under make Cummins part no. 3239599 in 250 / 200 KVA DG set as specified and directed by Engineer-in-charge
M & L for supply fixing in repairs magnetic pick up part No. 3875360 make Cummins suitable for 250 / 200 KVA DG set by taking out the defective unit from engine , replacing the same and adjusting the gap setting. Connecting in the circuit all as specified as directed by Engineer-in-charge
M & L for supply, carrying out repairs in the rotating rectifier kit diode sets P/N AX1006957 in 250 KVA DG set by taking out the defective from DG set, fixing new rectifierkit set in the alternator and connecting with circutis, starting and testing the DG set on load all as specified and directed by Engineer-in-charge
M & L for supply, carrying out repairs in the rotating rectifier kit diode sets in 250 / 200 / 100 KVA DG set by taking out the defective from DG set, fixing new rectifierkit set in the alternator and connecting with circutis, starting and testing the DG set on load all as specified and directed by Engineer-in-charge
M & L for supply , fixing of Air filter of 82.5 KVA / 62.5 KVA / 40 KVA DG set all as specified and directed by Engineer-in-charge
M & L for supply, fixing of Air filter of 400 KVA DG set all as specified and directed by Engineer-in-charge
M & L for supply , fixing of Air filter of 25/30 KVA DG set all as specified and directed by Engineer-in-charge
M & L for supply , fixing of water pump of 250 KVA DG set Cummins parts no. AR45347 all as specified and directed by Engineer-in-charge
M & L for supply , fixing of fan belt set of 3 nos in 400 KVA DG set all as specified and directed by Engineer-in-charge
M & L for supply , fixing of fan belt set of 3 nos in 250 KVA DG set all as specified and directed by Engineer-in-charge
M & L for supply, fixing of belt battery charging dynamo belt in 250 KVA DG set cummins part no. all as specified and directed by Engineer-in-charge
M & L for supply, fixing of fan belt ( set ) in 2530/ 62.5/ 82.5 KVA DG set all as specified and directed by Engineer-in-charge
M & L for repair and reconditioning the starting motor 12 V DC system of kirloskar make including taking out the defective starter from 20 KVA / 30 KVA / 32.5 KVA/50/100 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bushes, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
M & L for repair and reconditioning the starting motor 24 V DC system of kirloskar make including taking out the defective starter from 500 KVA / 200 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, bushes, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
M & L for supply and fixing of AMF Logic conttroller (Microprocessor based type) by taking out the defective unit from 200 KVA /82.5 KVA / 62.5 KVA / 82.5 KVA / 30 KVA capacity DG set complete checking the panel and its connection circuit in the panel board, providing prper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge Make: C & S / L&T/Cummins
M & L for taking down unserviceable starting motor from the engine 20 / 30 KVA and supply and fixing starter assly under part no. and connecting with circuit and testing complete all as directed.
M & L for supply, fixing and testing DG set stop solenoid switch in 200 KVA by taking out the defective switch from the DG set, replacing by new and aligning, connecting with circuit, starting and testing all specified and directed by Engineer-in-charge
M & L for supply, fixing in repair coil electrical in STC control valve under make Cummins part no.4963341 in 200 KVA DG set as specified and directed by Engineer-in-charge
M & L for supply, installation and commissioning of AVR Part no. AX1001054 for 250 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load in individually and parrelleling with other 500 KVA DG sets all as directed by Engineer-in-Charge
M & L for supply, fixing 4 Pole contactor 415 V AC, Amps rating 500, 415/240 V coil supply voltage, Model MCX 33, Make: L&T/C&S
M & L for supply, fixing spare coil 415V/240 V AC suitable for contactor 415 V AC,Model MCX 33, Make: L&T/C&S
Taking out ACB breaker for repair and servicing by disconnecting and dismantling the ACB breaker rating 2000 Amps / 800 Amps make L&T by carrying out repair/ servicing , checking and renewing the defective shunt trip coil & UV trip 415 V AC , checking and rectifying the defective CTs and rectifying the mechanism operation including spring charge system, reinstalling the same in the panel and providing necessary line and connections all as directed by Engineer-in-charge.
M & L for supply and fixing engine fuel hose set along connector for 400 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge
M & L for supply and fixing engine Lub oil hose set along adaptor for 400 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge
Supply only engine oil for filling / topping up grade 20W-40 multigrade meeting CE/CF4 for the DG set of different capacity. Engine oil shall be make of Servo/Valvoline/Castral
Supply only engine oil for filling / topping up grade 15W-40 multigrade meeting CE/CF4 for the DG set of different capacity. Engine oil shall be make of Servo/Valvoline/Castral
S & Fixing in repair and rewinding the excitor stator assembly of 250/400 KVA by takingout complete burnt coils, cleaning and rewinding the same by supper enamel copper wire SWG 18, insulalting the coils with nomex paper, milinex sheet, heating and varnshing by varnish materials and applying one coat of bectol anti rust protection, fixing back in to the alternator, connecting teh cables, starting and testing all as specified and directed by Engineer-in-charge
S & Fixing in repair and rewinding the excitor stator assembly of 25 KVA to 82.5 KVA by takingout complete burnt coils, cleaning and rewinding the same by supper enamel copper wire SWG 18, insulalting the coils with nomex paper, milinex sheet, heating and varnshing by varnish materials and applying one coat of bectol anti rust protection, fixing back in to the alternator, connecting teh cables, starting and testing all as specified and directed by Engineer-in-charge
S & Fixing in repair and rewinding of alternator of any size and capacity of 25 KVA to 400 KVA by takingout complete burnt coils, cleaning and rewinding the same by supper enamel copper wire SWG 18, insulalting the coils with nomex paper, milinex sheet, heating and varnshing by varnish materials and applying one coat of bectol anti rust protection, fixing back in to the alternator, connecting teh cables, starting and testing all as specified and directed by Engineer-in-charge
M & L for supply, fixing fan belt mult V rib type under Cummins Part no. 3979425 in 250 KVA DG set all as directed by Engineer-in-Charge
M & L for supply, fixing fuel oil pressure sensor kirloskar make 400 KVA DG set all as directed by Engineer-in-Charge
M & L for supply, fixing low coolant water level sensor Kirloskar make 400 KVA DG set all as directed by Engineer-in-Charge
M & L for fixing battery charger 230 V AC input and output 24 V / 12 V 10 amps charging rating IMPS type with fully auto control in charging and floating with boost system all as specified and directed by Engineer - in charge
Repair overhauling & removel of leakage from radiator & refixing it duly repaired , cleaning descaling ,welding brazing etc . incl. Replacement of rubber hoses & clips etc. complete in all respect of the followling capacities of DG sets :-
(a) 25 KVA to 62.5 KVA
(b) 80 KVA to 82.5 KVA
(c) 200 KVA to 400 KVA
Repair / overhauling of self starter incl. Replacement of carbon brusses, bearing, bushes, rewinding of armature and fild etc. and warnishing complete all as directed for the following 12volt make lucas.
Spray painting of DG sets , Alternator , Panel ,diesel tank and base frame etc. with one coat of synthetic enameld paint as per MES colour code after cleaning of old painted surface rubbing of old paint and making surface for paint etc complete all as directed by EIC for the following capacity DG set.
(a) 25 KVA to 62.5 KVA
(b) 80 KVA to 82.5 KVA
(c) 200 KVA to 400 KVA
S & F heat proof Asbestos rope 12 mm dia in engine exhaust pipe including dismantling of worn out Asbestos rope and minor welding / tightaning in leakage exhaust complete all as directed conferming to IS specification .fire proof /flame proof.
S&F in repair AMF pannel 25/30 KVA including relay slecter switch existing unserviecable contractor indicater lamps internal wireing and making of automatic starting machnisium for opreating self start in faulair of commercial electric supply.
S&F inrepair AMF pannel 82.5KVA including relay slecter switch existing unserviecable contractor indicater lamps internal wireing and making of automatic starting machnisium for opreating self start in faulair of commercial electric supply.
Dismantling of UNSV self starter of capacity 24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of one field coil, repair and rewinding of armature and return to the existing place after repairing.
S&F contactor 4 pole 400 Amps, 415 volts. MCX-31 of Make L&T/siemens/Schneider/Havell's
Repair to main control Panels of 62.5 KVA to 100 KVA DG set including dismanteling/taking down of all electrical connection from unserviceable AMF panel and tpt to local workshop to carry ot following repairs :- (a) Replacement of unserviceable microprocessor auto main failure relay 400 volt AC 3 phase 4 wire system having following parameter :- (i) Display of RYB phase voltage (ii) Display of generating voltage (iii) Display of generator frequency (iv) Display of main frequency (v) Display of battery voltage (vi) Display of single phase current (vii) Display of generator run hurs Make:- C&S/Hitech or equivalent (b) Replacement of digital multifunctional meter of size 96x96mm having following parameter:- (i) Voltage, ampere and frequency :- Make-HPL/AE/Naptune (c) Replacement of digital energy meter 3 phase of size 96X96mm. Make -Naptune/HPL-01 Nos (d) Replacement of safety control relay for cranking-01 Nos (e) Replacement of burnt out control wiring for panel with suitable size of lugs (f) Tpt to same to the site and all incomming/outgoing cable and testig compete as entire satisfication of Engr-in-Charge
Supply and fix in repair change over switch ON load type with sheet metal enclosure 400 Amps four pole.Make L&T/siemens/Schneider/Havell's
Repairing of diesel engine generating set Make : Kirloskar capacity 82.5 KVA and dismantling of the engine strip opening etc. (a) Valve seat cutting and fixing of the valve guide. (b) Griding and polishing of crank shaft complete. (c) Fixing of the cylinder liner. (d) Cylinder block line bearing and threading of existing holes. (e) Fixing of the piston ring complete. (f) Repair to cylinder head, injector sleeves including fixing and testing complete. (Note : All spare parts for replacement/fixing shall be supplied under relevant items).
Supply only following spare parts for 82.5 KVA Gen Set of existing make and suitable for Kirloskar Engine :-
(a) Upper gasket set
(b) Lower gasket set
(c) Main bearing
(d) CR bearing set
(e) Cylinder liner with 'O' ring
(f) Piston assy set.
(g) Piston ring set
(h) In let valve
(j) Exhaust valve
(k) Valve seat
(l) Valve guide
(m) Rear oil seat
(n) Accessory drove oil seat
(o) Connecting rod bolt with nuts
(p) Thrust washer set
(q) Accessory drive shaft
(r) Accessory drive pulley
(s) Push rod valve
(t) Push rod (injector)
(u) Radiator hose pipe
(v) Cooler hose pipe
(w) Thermostat
(x) Hose pipe
(ab) Slinger
(ac) Cam thrust washer
(ad) Seal key
(ae) Rubber insert
(af) Lub filter gasket
(ag) SLO by pass filter gasket
(ah) Main bearing lock
(aj) Adjusting nut
(ak) Fuel connecting screen filter
(al) Ferrule
(am) Accessory drive thrust washer set
(an) Hose by pass
(ao) Governor spring
(ap) Throttle cable
(aq) Pressure gauge
(ar) Lub oil filter spring
(as) Lub oil washer
Calibration and over hauling of PT pump with replacement of following for following for 82.5 KVA (Make : Kirloskar ) DG Set :- (a) Throttle shaft of PT Pump. (b) Kit barrel and plunger. (c) Gasket Set. (d) Shim (e) Wahser. (f) Gear pump. (g) Seals. (h) Gear pump adopter (j) Elbow. (k) Cap screw. (l) 'O' ring. (m) Screen filter.
Calibration and over hauling of injector assembly including replacement of necessary spare parts for 82.5 KVA all as directed. Make : Kirloskar Cummins DG Set.
Repair to diesel engine generating set Make Kirloskar, capacity 62.5/40 KVA and dismantling of the engine carefully, checking throughly all the parts including repair/replacement of the following defective parts through authorised service engineer/mechanic from M/s Kirloskar Oil Engines Ltd. Reassembly the engine after overhauling including commissioning testing complete. (a) Repair to cylinder head including fixing and testing complete. (b) Valve, valve seats and valve guide, cutting, grinding and polishing complete. (c) Reaming, grinding and fixing of small end bushing of connecting rod. (Note : All spare required for replacement shall be supplied under item here-in-after).
Supply only following spare parts against item No 84 above of existing make suitable for Make Kirloskar DG Set.
(a) Piston assembly.
(b) Small end bushing for connecting rod.
(c) Big end bearing connecting rod.
(d) Valve guide.
(e) Valve seat.
(f) Valve inlet.
(g) Valve exhaust.
(h) Valve push rod
(j) Bush set.
(k) 'O' ring set.
(l) Copper washer set.
(m) Gasket set.
(n) Micro filter element.
(o) Pre filter element any make and type
(p) LO filter element any make and type
(q) Pressure gauge.
(r) Fuel filter element any make and type
(s) Oil pump assembly.
(t) Self starter 12 volts.
(u) Dynamo 12 volts.
Calibration and over hauling FTP or PT Pump of 62.5 KVA DG Set with replacement of the following parts :- (a) Delivery valve - 06 Nos. (b) Bearing - 02 Nos. (c) Elements - 06 Nos. (d) Main spring - 06 Nos. (e) Gasket sets. (f) Seal. (g) Cap screw. (h) 'O' ring - 01 Set. (j) Governer assembly - 01 Set. (k) Screen filter.
Calibration and overhauling of injector assembly of 62.5 KVA DG Set including replacement of necessary spare parts complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out soft/loose soil complete all as specified and as directed for foundation of stay, laying of cable etc. complete all as specified and directed.
Returning filling in soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for fly ash/burnt Bricks, sub class 'B' dry, well brunt bricks laid in trenches for cable protection all as specified.
M&L for sand filling in trenches for cushioning of cable complete all as specified and directed. Note:- Compacted /punned thickness of sand shall be considered for the payment.
M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc all as specified and as directed.
Taking up old serviceable/unserviceable UG cable from trench for replacement , repair and re-laying or re-routing of size 50 Sqmm to 70 Sqmm complete all as specified and directed.
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade with cross sectional area of the following size 95 Sqmm complete all as specified and directed.
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade with cross sectional area of the following size 50 Sqmm complete all as specified and directed.
Boring of holes under road, pavement, hard standing for more than 5 mtr in length by trenchless, technology using ultra sound technique and necessary machine, including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately.
Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth complete all as specified and directed.
S & F GI tubing 40 mm dia light grade in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc all as directed.
Taking down old unserviceable distribution board of any size and any capacity . Note : (i) Old dismantled wiring and accessaries will be contractors property and credit will be charged against schedule of credit.
Supply and fixing sheet metal enclosure double metal door factory made TPN 415 volt 4 way suitable for fixing MCB as outgoing and MCCB TP 63 to 125 Amps 16 KA as main incoming duly painted all as specified in cat No. DBVTL004DD of L&T or equivallent including necessary electrical connection and flush in wall with necessary pcc works and make good the distrubed surface with existing surface complete all as specified and directed.
S&F in replacement of MCCB 3 pole, capacity 125 Amps with breaking capacity 16 KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand
-ditto- but SP 5 to 32 Amps ,240 Volts. Make Legrand 603234 or equivallent Havells/Schneider
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to earthing lead of 4 mm dia galvanised iron by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion
Earthing complete with copper earth plate electrode 60 cm x 60cmx 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to copper strips 20x3 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion complete all as specified and directed.
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 25x4 mm galvanised iron strip complete all as specified and directed.
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 20X3 mm copper strip complete all as specified and directed.
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 32x6 mm copper strip complete all as specified and directed.
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of earthing lead of 4 mm dia galvanised. complete all as specified and directed.
M&L for set of Chemical/GEM/GEL Earthing system with earth electrode of for copper bonded low carbon steel core of 3 meter long having outer dia 80mm & inner dia 50mm duly filled with highly conductive and anti corrosive compound of required quantity with chemical composition Bentonite 40%, Copper sulphate 10%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10%, buried directly in ground ( 150-175 mm dia digging or auguring of earth to the required depth as specified by manufacturer and directed ) and pit filled up with GEL form of Electrolytic and Moisture retention type Earthing tested for less than 0.50 ohm Resistivity and connected with copper strip (32x6mm) to rod connected by means Given Terminal point with copper Nut Bolts, provision of ready made polymer chamber with cover, including necessary excavation in any type of soil, returning filling in, removal of surplus soil complete all as specified and as directed. (Makes: Pittas, RPG,HSL Industries, Roksna, Furse)
Note: 1. Earthing pit locations shall be identified as per IS-3043 prior to start the work and make to be approved by GE. 2. Earthing system shall be designed so as to achieve test result less than 0.50 Ohms by making an arrangement of minimum 4 Electrodes By interconnecting with copper Strip to make a parallel connection to achieve the required ohmic value. 3. Copper strip to be extended upto the equipment and power room. It shall be routed in the side wall of the under ground ducts fixed with ceramic/porcelain/PVC spacers . 4. Ready made polymer chamber with cover of suitable size shall be provided directly. 5. Copper strip shall be of 32x6mm as directed above upto test point max upto 7.50mtr is included in quoted rate of earthing. 6. Authorized manufacturer gurranty certificate is mandatory for two years maintanance free with result shall remains below 0.50 Ohms.
M&L for spray painting to LT panel board complete from inner and outer side with one coat of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces and welding work as required complete all as specified and directed including disconnection of supply from main comlete all as specified and directed. (approximate 8 sq mtr of each panel board )
M & L for welding of Panel door inner and outer and MCCB doors from front and back with necessary hinges & locking arrangements including properly disconnection of old unserviceable parts, MS sheet and angle irom complete & locking arrangements including replacement of followings (Note MS Sheet and angle iron will be measured and paid separated.
Supply and fix in replacement of MS sheet duly powder coated for enclosing the feeder pillar box of any size inclding taking down old rusted MS sheet complete all as specified and directed.
Supply and fix in replacement of MS Angle irom of size 50x50x50x6 and 40x40x6 mm sheet duly painted for bracing the sheet and also give the structure for the feeder of any size inclding taking down old rusted MS angle complete all as specified and directed.
Supply and laying of round boulders of gauge 63 mm graded as in bedding layer around electrical equipment or installation ,LT Panel etc complete all as specified and directed.
Supply, installation, commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables (make of Panel- Universal switchgear/ Advance Switchgear/ conolec / L&T ) :-
OUT GOING:- (a) MCCB four pole 160 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 02 Nos .(b) MCCB four pole 100 Amps, 16 KA at 415 Volts, adjustable thermal and magnetic setting- 04 Nos .
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables (make of Panel- Universal switchgear/ Advance Switchgear/ conolec / L&T ) :-
OUT GOING:- (a) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 03 Nos .
Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar box any type and capacity including all control switches, fitting and fixtures from different location including disconnection of existing electric incomming and outgoing cable and dismantling of PCC platform and make good with existing surface complete all as directed by the Engr-in-Charge.
Notes:- (a) The amount of Rs. 231144/- against Schedule of Credit on Page No. 128 & 129 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) As contract is maintenance nature the site shall be handed over in pieces as per site availability from users.
V.K. Enterprises
M/S PARKASH ENTERPRISES
Sumit Enterprises
B S R Enterprises
B S ENGINEERS AND ASSOCIATES
Shrikanth Solutions
M/s Adhikari construction co.
S.R. Constructions
R. S. Associates
Bluemax Associate
GILL ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .