| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹50.9 L+₹55,725 (1.11%)Rejected-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹51.0 L+₹62,210 (1.24%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹51.4 L+₹1.0 L (2.07%)Rejected-Finance | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹51.8 L+₹1.5 L (2.95%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L5 | Rejected-Finance rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
27 Mar 2021, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
REPAIR REPLACEMENT OF UNSERVICEABLE WIRING AND ACCESSORIES UNSERVICEABLE DISTRIBUTION BOARDS GEYSERS AND ALLIED WORKS AT ADE GTRE AND CABS UNDER AGE EM GEI R D EAST BANGALORE
2021_MES_420693_1
8994
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE I R AND D East Bangalore
D b (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹92,000
Yes
7 May 2021
10 Feb 2021
29 Mar 2021
10 Feb 2021
27 Mar 2021
1 Mar 2021
11 Feb 2021 - 24 Feb 2021
Amount
M&L Point wiring complete with Multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed,FRLS cable , 1100 volts grade conforming to IS 694 multistranded , drawn in rigid PVC type conduit concealed in walls / floors/ ceiling etcwith and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly,cutting chasis to the wall s/ floors/ ceiling and repairing with existing surface after work ,complete including taking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc all as specified and as directed.
One light/ fan/exhaust fan point controlled by one way switch
One light point controlled by 02 two way switches
One three pin socket outlet 6 amps socket on the same board with other switches
One 3 pin socket point 5 Amps on the independent board.
One bell point controlled by one bell push
All as per item No 1 here-in-before, but using copper conductor 2.5 sqmm PVC insulated unsheathed FRLS cable with copper conductor size 1.5 sqmm PVC insulated unsheathed continuous earth continuity for 3 pin 15 amps socket outlet independently all as specified and as directed by Engr-in-Charge.
Supply & fix switch modular type single pole 1 way 5 Amp 230 volt complete as directed.
Supply & fix switch modular type single pole 2 way 5 Amp 230 volt complete as directed.
Supply & fix socket 6 Amps modular type, 230 volts grade all as directed.
Supply & fix switch modular type 1 way 16A, 1 module all as specified and as directed.
Supply & fix Socket Modular type 6A/16A 2-3pin combined 2 module 230Volts grade all as directed.
Supply & fix Modular switch bell push 6 Amps one module all as specified and as directed by Engr-in-Charge
Supply & fix modular type fan regulator 120 W two module complete all as specified and as directed by Engr-in-Charge
Supply and fix bell AC 230V single phase all as specififed and as directed by Engr-in-Charge
Supply & fix ceiling rose surface bakelite two to three terminal complete all as directed.
Supply & Fix angle holder polycarbonat/bakelite type with back plate complete all as specified and directed including one number LED lamp of 9Watts
Supply and replacement of LED type 4 feet tube light fitting surfac mounted of 20Watts anodized extruded aluminium housing high lumen output complete all as specified and directed Make : Bajaj Cat Part No :BCLAB 20W or equivalent in CG/Havells/Phillips
Supply and replacement angle holder/tube light fitting with decorative LED mirror light fitting surface mounted of capacity of 07W translucent acrylic diffuser including driver and accessories complete all as specified. including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed Make : Crompton Cat Part No : LCL-07-CDL or equivalent in Havells/WIPRO/Phillips
Supply and replacement of any type of fitting with LED type surface mounted decorative oval bulk head fitting edge lit of 10Watts complete including connecting to ceiling rose with twin copper conductor of size 0/0.24 all as specified and directed Make : CG Cat part No : LBHP-10-CDL or equivalent in WIPRO/Havells/Phillips
Dismantling the ceiling fan complete of any type and size , cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor and complete testing all as directed Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted
Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper wining from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling , greasing to bearing , replacing bushes, replacment of capacitor and complete testing all as directed. Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan will be measured and paid separately under respective item. (b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and fro from site to work place are deemed to be included in rate quoted.
All as per item No 17 herein before, but for 1400mm sweep ceiling fan complete
All as per item No.17 herein before, but for 300mm sweep exhaust fan complete
All as per item No.17 herein before, but for 450mm sweep exhaust fan complete
Supply and replace worn out fan bearings of the existing size of superior quality complete all as specified and directed
Supply and replace capacitor 2.5mfd suitable for 1200mm sweep ceiling fan complete all as specified and directed
Supply and replace capacitor 4.0mfd suitable for exhaust fan complete all as specified and directed
Supply and replace rubber reel of superior quality along with gun metal frame and split pin complete all as specified
Supply and fix exhaust fan louvers on outside of the external wall suitable for 380mm sweep complete all as specified and as directed
Supply and fix exhaust fan louvers on outside of the external wall suitable for 450mm sweep complete all as specified and as directed
Painting of ceiling fan along with down rod and blades using spray gun with existing colour at the site including dismantling the fan from the hook complete all as specified and as directed
M & L for submain wiring of 2 run 4 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories concealed in wall/roof including one run of 2.5 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge Note :-(i) One run of PVC conduit, two runs of copper cable and one run of earth wire shall be measured and paid as one unit.
M & L for submain wiring of 2 run 6 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories concealed in wall/roof including one run of 4 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge Note :-(i) One run of PVC conduit, two runs of copper cable and one run of earth wire shall be measured and paid as one unit.
M & L for submain wiring of 4 run 10 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories concealed in wall/roof including two run of 6 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge Note :-(i) One run of PVC conduit, four runs of copper cable and one run of earth wire shall be measured and paid as one unit.
Supply and fix in replacement of MCB DB SPN 4 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed
Supply and fix in replacement of MCB DB SPN 6 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed
Supply and fix in replacement of MCB DB SPN 8 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and as directed
Supply and fix in replacement of MCB SPN 6-32Amps 230 Volts single phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB SP 6-32Amps 230 Volts single phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB TP 63Amps 415 Volts three phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB TPN 6-32Amps 415 Volts three phase all as specified complete including dismantling the old one
Suply and fixing in replacement of Hylum sheet with not less than 3mm thick of size 4" x 4" complete
Suply and fixing in replacement of Hylum sheet with not less than 3mm thick of size 4" x 6" complete
Suply and fixing in replacement of Hylum sheet with not less than 3mm thick of size 6" x 8" complete
S & F modular frame plate with inner ,outer plate and sunken box except sockets and switches suitable for 1/2/3 modules of any type with mounting screws and making good the disturbed surface all as specified and directed Make : Crabtree/Legrand/Havells/Anchor
S & F modular frame plate with inner ,outer plate and sunken box except sockets and switchessuitable for 4/6 modules of any type with mounting screws and making good the disturbed surface all as specified and directed Make : Crabtree/Legrand/Havells/Anchor
S & F modular frame plate with inner ,outer plate and sunken box except sockets and switchessuitable for 8/10 modules of any type with mounting screws and making good the disturbed surface all as specified and directed Make : Crabtree/Legrand/Havells/Anchor
M&L for disconnecting the electric supply, disconnecting the water pipe (cold and hot water) from the geyser of any make and any capacity, taking down the geyser by unscrewing nuts, bolts & washer from its existing place, cleaning geysers tank body properly, removing scaling with the help of brush, cleaning material etc. and re-fixing the geyser at its original place by screwing nuts, bolts & washer, connecting the water pipe (hot and cold water) and the electric supply including testing of geyser for proper working to the entire satisfaction, all as specified and as directed by Engr-in-charge Note: Spares required for geyser will be measured and paid separately.
M&L for taking out the unserviceable heating element of capacity 1.5 KW of any make and S&F new heating element of capacity 1.5 KW all as specified and directed by Engr-in-charge. Make - Roxy/ Power pack or equivalent
All as per item No 45 above, but of 2 KW for geyser upto 50 ltrs capacity .Make : Roxy/ Power pack or equivalent
S&F thermostat switch suitable for fitting to geyser upto 50 ltrs capacity . Make : Girish/Roxy/Klick.
M&L PVC connecting pipe with brass union fitted at both and suitable for connection to 15mm GI pipe length of PVC connection 450 mm long for hot water including 01 No PVC washer on both lends.
All as per item No. 48 above but for cold water supply.
Repairs of Geyser assembly complete with brazing of brass tube stud, nut bolts and copper tank for a length not exc. 5.0 cm in each geyser.
M&L rubber gasket for apparatus plate to suit the geyser assembly and water tank assembly.
Replacement of bottom plate cover of MS sheet to suit the geyser capacity 25 ltrs including painting to the cover plate with 02 coat of white synthetic enamelled paint over a coat of red oxide primer.
All as per item No. 52 but for 50 ltrs.
All as per item No. 52 but new top covers of geyser capacity 25 ltrs.
All as per item No. 52 but new top covers of geyser capacity 50 ltrs.
S&F in repair in replacement of outer shall/body without bottom cover for 25 ltrs capacity geyser made of MS sheets duly painted, complete all as directed by Engr–in–Charge.
All as per item No. 56 above but for geyser of capacity 50 ltrs
S&F in replacement of inner copper tank for 25 ltrs geysers complete all as directed by Engr-in-charge
All as per item No 58 above but for 50 ltrs capacity geyser
S&F new assembly of geyser base plate complete with inlet and outlet brass tubes including nut, bolts, washer for 25 ltrs capacity
All as per item No 60 above but for 50 ltrs capacity geysers
S& F indicating lamp green and red in colour of geysers
S&F non return valve to geyser of 15 mm dia Make - Leader/ shakti
S&F glass wool in geyser tank and taking out U/S glass wool as per sample
S&F plug top 3 pin 15 Amp, Make - Anchor/ HPL
S&F Metal clad Industrinl Socket 32 Amp and fixed complete suitable for gyeser Make - Havells/ HPL
M&L for providing PVC flexible copper cable 3 core 40/ 0.0076 for geyser cord Make - Havells/polycab
M&L for stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends iron pipe or for union and fixed of 15 mm dia Make - Leader/shakti
M&L Painting of geyser after removing old paint and making surfaces smooth for repainting with super enamelled paint of same tint as of original all as required at site upto 50 ltrs capacity
M & L for repairs to existing broken switch board by taking out the old exisiting switches, sockets, regulators flush type/modular type, new switch , socket regulators and refixing the same after replacement of hylum sheet /modular plate of required size under mentioned with electrification of u/s board, making screws and made functional with all electric connections as per speciifed and directed Note: Switches , sockets, regulators, hylum sheet, modular plate if required will be measured and paid separately.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground( earth pit not less than 2.25metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected as required 32 x 6mm upto 7.5Mtr GI strip up to means of GI bolts, nuts , check nuts and washers and connected to building panel/DB all as shown in electrical plate No. 3 of SSR Part I and all as specified including testing on completion, taking down old unserviceable earthing complete all as specified and directed by Engr-in-Charge.
ARUNOTHAYA TRADERS
RAHUL ENTERPRISES
GURU ENTERPRISES
Lucky Enterprises
Meghana and Gowda Enterprises
AishwaryaConstructions
devan enterprises
SAI CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .