| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹5.8 L+₹86,024 (17.4%)Rejected-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹5.9 L+₹97,080 (19.6%)Rejected-AOC 4 94D RAJA COTTAGE 1ST FLOOR KANYAKULAM PARVATHIPURAM NAGERCOIL KANNIYAKUMARI TAMILNADU 629 003 | KANNIYAKUMARI | TAMIL NADU | 629003 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹5.9 L+₹98,895 (20.0%)Rejected-AOC KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L4 | Rejected-AOC NOT LOWEST |
| Sl No | Description | Qty | Unit | GS TRADERS L4 | Shiva Shakthi Electrical Enterprises L1 | Vasavi Electricals L2 | ADR ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables complete all as specified and as directed. | 168 | Cum | 300 ₹50,400 | 300 ₹50,400 | 295 ₹49,560 Lowest | 475 ₹79,800 |
| 2.00 | Returning, filling in trenches including spreading leveling watering and well ramming in layers with soil not exc 25 cm thick in each layer complete as specified and as directed | 95 | Cum | 40 ₹3,800 Lowest | 40 ₹3,800 Lowest | 58 ₹5,510 | 225 ₹21,375 |
| 3.00 | Removing of excavated soil to a distance not exc 50m and depositing 1.5 mtr above the starting point where directed complete all as specified and as directed | 73 | Cum | 60 ₹4,380 | 40 ₹2,920 Lowest | 78 ₹5,694 | 350 ₹25,550 |
| 4.00 | M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed | 60 | Cum | 900 ₹54,000 | 800 ₹48,000 | 695 ₹41,700 Lowest | 1,600 ₹96,000 |
| 5.00 | Supply & laying sub class 'B' burnt bricks for cable protection all as per Para 19.75 of SSR Part-I complete all as specified and as directed | 8,000 | Each | 9 ₹72,000 | 7 ₹56,000 Lowest | 9 ₹72,000 | 8 ₹64,000 |
| 6.00Supply and laying L T XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable lugs for following size complete all as specified and as directed :- | |||||||
| 7.00 | 2 Cores x 6 Sqmm | 615 | RM | 115 ₹70,725 | 85 ₹52,275 | 140 ₹86,100 | 77 ₹47,355 Lowest |
| 8.00 | 3.5 Cores x 50 Sqmm | 615 | RM | 430 ₹2,64,450 | 360 ₹2,21,400 | 370 ₹2,27,550 | 289 ₹1,77,735 Lowest |
| 9.00 | M & L for GI tubing light grade 40mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches including necessary M S clamps, bolts and nuts etc all as specified and as directed. | 15 | RM | 300 ₹4,500 Lowest | 530 ₹7,950 | 300 ₹4,500 Lowest | 400 ₹6,000 |
| 10.00 | M & L for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches including necessary M S clamps, bolts and nuts etc all as specified and as directed. | 5 | RM | 400 ₹2,000 Lowest | 650 ₹3,250 | 400 ₹2,000 Lowest | 600 ₹3,000 |
Tender Value
₹5.3 L
EMD Value
₹10,600
Closing Date
4 Aug 2025, 6:00 pmClosed
COL VIBHOR JAIN, CWE
CWE (ARMY) BANGALORE, 101, DICKENSON ROAD, BANGALORE - 560042
SPECIAL REPAIRS / REPLACEMENT FOR CONVERSION OF OH LINE TO UG CABLE AND ALLIED SERVICES AT STATION MAGZINE GUARD AT 4/8 GR UNDER GE (NORTH) BANGALORE
2025_MES_718859_1
86423/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹10,600
19 Sept 2025
7 Jul 2025
11 Aug 2025
7 Jul 2025
4 Aug 2025
21 Jul 2025
7 Jul 2025 - 14 Jul 2025
Amount
Excavation in trenches in soft/loose soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables complete all as specified and as directed.
Returning, filling in trenches including spreading leveling watering and well ramming in layers with soil not exc 25 cm thick in each layer complete as specified and as directed
Removing of excavated soil to a distance not exc 50m and depositing 1.5 mtr above the starting point where directed complete all as specified and as directed
M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed
Supply & laying sub class 'B' burnt bricks for cable protection all as per Para 19.75 of SSR Part-I complete all as specified and as directed
Supply and laying L T XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable lugs for following size complete all as specified and as directed :-
2 Cores x 6 Sqmm
3.5 Cores x 50 Sqmm
M & L for GI tubing light grade 40mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches including necessary M S clamps, bolts and nuts etc all as specified and as directed.
M & L for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches including necessary M S clamps, bolts and nuts etc all as specified and as directed.
M&L for Plain Cement Concrete (1:4:8) type D-2 using 40mm graded stone aggregate in foundation of poles all as specified and as directed
Dismantling and taking down the existing L T over head ACSR line of any description all as directed
Dismantling and taking down the existing LT insulators of any type any size of any description all as directed
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed
M&L for Out door type, double door sheet metal enclosure/ Bus bar chamber of suitable size with aluminium bus bar 200 Amps, IP-54 for 3 phase & neutral including MCCB 4 pole 415 volts 32 Amps 16 KA as incomer and Timeline distribution board of 110 Amps 3 pole/230 volts-Digital time switch on pole and wall with a help of suitable size of clamp complete all as specified and as directed
Supply and fixing moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 2 way heavy duty terminal block with MCB SP 6 Amp and two number of cable entry gland of standard size with suitable MS bracket to fix with pole complete all as specified & directed
M&L for Two runs of PVC insulated 2.5 sqmm single core multistranded copper conductor cable and one run of 2.5 sqmm copper wire as earth continuity conductor drawn through and including suitable size rigid non metalic conduit fixed on poles & connecting up all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit length.
Vasavi Electricals (BID ID -3381499)
ADR ENTERPRISES (BID ID -3372018)
GS TRADERS (BID ID -3368300)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .