Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.9 L+₹88,470 (1.92%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹57.2 L+₹11.3 L (24.5%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹80.9 L+₹34.9 L (75.9%)Rejected-Finance | L4 | Rejected-Finance Not being lowest |
Tender Value
₹50.0 L
EMD Value
₹99,900
Closing Date
20 Sept 2022, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer -345001
REPLACEMENT OF SUBMAIN WIRING FROM MAIN DBS TO SUB DB AND ASSOCIATED WORKS AT MD ACCN OTM ACCN UNDER THE JURISDICTION OF GE (A) JAISALMER
2022_MES_546895_1
8228/22-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹99,900
Yes
15 Nov 2022
23 Aug 2022
22 Sept 2022
23 Aug 2022
20 Sept 2022
5 Sept 2022
Amount
Taking down of old unsv submain wiring of any type any size complete all as specified and directed with casing capping complete all as specified and directed by Engineer-in-charge.
Taking down submain wiring any type any size from existing concealed /surface conduit complete all as specified and directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking down the existing unserviceable MCBs/MCCBs of any type/ capacity/ description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking down of old unsv tubelight fitting /bulkhead/ garden light/ gate light of any descriptionlight fitting any type any watt complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 4.0 Sq mm (FRLS) in and including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 4.0 sqmm cable & One run of 4.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length.)
M & L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 4.0 Sqmm (FRLS) in existing concealed/Surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 4.0 Sqmm cable & One run of 4.0 Sqmm cable shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLS) in and including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 6.0 sqmm cable & One run of 6.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLS) in existing concealed /surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 6.0 Sqmm cable & One run of 6.0 Sqmm cable shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sq mm (FRLS) in and including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 10.0 sqmm cable & One run of 10.0 sqmm cable and One run of PVC casing/capping shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sq mm (FRLS) in existing concealed /surface PVC conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 10.0 sqmm cable & One run of 10.0 sqmm cable and One run of PVC conduit shall be paid as one unit length.)
M & L for submain wiring with approved colour code/as per IS (Red,blue & yellow for three phase) conduit circuit with one black colour single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) for neutral in PVC surface conduit pipe suitable size including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge.(Note :- four runs of 10.00 Sqmm cable & one run of 10.00 Sqmm cable and One run of PVC conduit pipe shall be paid as one unit length.)
Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X 40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10%, Necessary mounting arrangements. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report as per PHILIPS CAT PART NO. BN100C LED40S-6500 PSU L120 GR S4 or equivalent in Appx 'B' list of makes.
S & F for LED tube light fitting 10 Watt, 2 Feet or 591 MM in length, IP 20 Protection, wall mounted type, Slim LED Batten with extruded aluminium housing and polycarbonate diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver, IP 20 Protection, Opreating voltage 240 V , 50Hz AC Supply and Operating tempraeture 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 1000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
Supply and fixing of recessed/ceiling mounted down lighter with CRCA housing with high bright LED,idealy suited for low ceiling areas Brilliance 36watt LED, size 2ft x 2ft The product features color tuning from 3000 K to 6500 K, necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
S&F LED down lightrecess mounted/ Surface mounted/POP mounted or as per site requirement, square/Round type worm white / Neutral white or 3000 K /4000 K/ 5600 K as per user requirement 20 watts with efficiency of 100 lumens per watt, in worm white/ neutral white as per site requirement sleek design aluminium housing polycarbonate diffuser white finish operating voltage from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
S&F bldg security light fittings Wall mounted LED light 35 Watt including bracket made out of GI pipe (medium grade) 40mm, 1.20 metre long made to shape and fixed outside of the building by means of 2 No FI 40x6 mm clamps with suitable size of nuts, bolts, washers and connecting with three core copper flexible cable of size 1.50 Sq mm complete all as specified and directed by Engineer-in-charge.
S&F Integral decorative LED bollard with polycarbonate diffuser square shaped with IP 65 protection suitable for 10 watts LED with necessary MS base box made out of MS sheet of 2 mm thick of suitable size abbended in PCC 1:2:4 base, elecrical connections with adequate size including removal of old unserviceable one complete as all specified and as directed. Make:Havells Cat part No Havells OUNTBL10WLED830PSYMTOPMMA (0.6 M) or equivalent in Appx 'B' list of makes.
S & F for LED post top lantern/gate Light 35 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection complete with all accessories including removal of old unserviceable complete all as specified and directed. Make-Havells Cat part No CORALPT35WLED830PSYMTOPC or equivalent in Appx 'B' list of makes.
Supply and fix energy saving, environment friendly & robust Highbay/Mediumbay roof truss light LED for covered shed 150 W IP65 luminaire with high efficacy with fixing arrangement such as bracket,MS clamp,Nut bolts etc and connecting complete all as specified and directed by Engineer-in-charge. Note:- Fixing of light at any height arrangement of ladder should be provided by contractor.
S & F for MCCB DB VTPN 8 way 415 V double door IP 43 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar capacity 250 A suitable for operation on 415 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-charge.
S & F for MCCB DB VTPN 4 way 415 V double door IP 43 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB SPN DB 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB SPN DB 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB SPN DB 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB SPN DB 2 way 240 volts sngle door with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 125 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note:- Suitable size and frame of MCCB required as per existing DBs at site and (Ics=Icu).
S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 100 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note:- Suitable size and frame of MCCB required as per existing DBs at site and (Ics=Icu).
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 40 To 100 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing miniature circuit breaker (MCB) of single pole and neutral SPN 32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing miniature circuit breaker (MCB) of single pole SP 10-32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply, install testing and commissioning weather and vermin proof electric energy meter box wall mounted factory fabricated outdoor type (CPRI approved) totally enclosed made out of 2.0 mm thick sheet metal enclosure of suitable size(IP 54 Protrction), for3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) for each meter and its MCB (SPN) and bottom gland plate and locking arrangement consisting of suffiecient Nos of circular cable entry holes at bottom with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with L.T armoured incoming and including required sizes of cable lugs of aluminium complete all as specified and directed and consisiting of following :- Size of Meter Panel should be (1.25MX1.00MX0.185M)
(Note: Old meter to be taken down from old meter box and refixing the same in to new meter box and the charges of above deemed in new meter box price) (a) MCCB 100 Amps 4P 25 KA(Ics=Icu), 415 V - 01 No. for incoming (b) LED type indicator lamp Red/ Yellow /Blue colour-01 set (c) Din rail and Section for fixing Energyy meter(The front portion of panel to be having Glass to view meter reading)- 5 Nos(4 for Qtrs and 1 for Staircase area) including taking out and refixing old existing meters. (d) Din rail and section for fixing including MCB SPN 63A for mains of Qtrs- 4 Nos and MCB SPN 20A for staircase-01 No. (e) Sufficient submain entries and exit for qtrs and staircase (f) Internal wiring/busbar for connection purpose
Supply, install testing and commissioning weather and vermin proof electric energy meter box wall mounted factory fabricated outdoor type (CPRI approved) totally enclosed made out of 2.0 mm thick sheet metal enclosure of suitable size(IP 54 Protrction), for3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) for each meter and its MCB(SPN) and bottom gland plate and locking arrangement consisting of suffiecient Nos of circular cable entry holes at bottom with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with L.T armoured incoming and including required sizes of cable lugs of aluminium complete all as specified and directed and consisiting of following :- Size of Meter Panel should be (1.25MX1.0MX0.185M)
(Note: Old meter to be taken down from old meter box and refixing the same in to new meter box and write to Meter MES No in black colour paint and the charges of above deemed in new meter box price) (a) MCCB 100 Amps 4P 25 KA(Ics=Icu), 415 V - 01 No. for incoming. (b) LED type indicator lamp Red/Yellow/Blue colour-01 set (c) Din rail and Section for fixing Energyy meter (The front portion of panel to be having Glass to view meter reading)- 7 Nos (6 for Qtrs and 1 for Staircase area) including taking out and refixing old existing meters. (d) Din rail and section for fixing including MCB SPN 63A for mains of Qtrs- 6 Nos and MCB SPN 20A for staircase-01 No. (e) Sufficient submain entries and exit for qtrs and staircase (f) Internal wiring/busbar for connection purpose
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .