Executive Engineer(A-M), Cooch Behar (Agri-Mech)
Pilkhana Road, Near Panchanan Barma University, Pin 736101
Installation of Chilakhana-I Solar-operated Mini RLI Scheme ( Mouza-Chilakhana, GP-Chilakhana-I, JL-79, Plot-403 and 405, Latitude-26.313266 N and Longitude-89.58958E) in Tufanganj-I Block on turn- key basis.
2026_WRDD_996688_1
WRDD/EEAM/COB/eNIT-14/2025-26
Open Tender
Project Work
180 days
Tufanganj-I
Please refer Tender documents.
8 documents required · 8 mandatory
₹53,500
26 Feb 2026
31 Jan 2026
23 Feb 2026
31 Jan 2026
20 Feb 2026
31 Jan 2026
SUPPLY OF UPVC PIPES, M.S,G.I ITEMS & MATERIALS of Solar MINI RLI Scheme (Inclusive all charges).
140 mm. dia P.V.C. pipe Class- I 140(with a loose matching coupler,class-II) marking IS No. 4985/ 1988 (ISI Marked) with latest amendments with free solvent cement.
110 mm. dia P.V.C. pipe Class- I (with a loose matching coupler,class-II) marking IS No. 4985/ 1988 (ISI Marked) with latest amendments with free solvent cement.
110 mm. dia P.V.C. pipe class-II ( with a loose matching coupler,class-II) marking IS No. 4985/ 1988 (ISI Marked) with latest amending with free solvent cement.
Coupler(Cl-II) for 140 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988 (ISI Marked), Part- II with free solvent cement.
Coupler(Cl-II) for 110 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988 (ISI Marked), Part- II with free solvent cement.
110mmx110mmx 110 mm. P.V.C. Tee with free solvent cement, IS 10124/2009(ISI Marked) Part-5(Class-II)
140mmx140mmx 140 mm. P.V.C. Tee with free solvent cement, IS 10124/2009 Part-5(Class-II)
140x 110 Reducer(cl-II) with free solvent cement. IS 10124/2009 (ISI Marked) Part-3 with latest ammendment
140 mm. dia 90 degree bend (cl-II) ( IS. No. 10124/ 88 (ISI Marked) Part- 8 with latest amendment )
110 mm. dia 60 degree bend(cl-II) ( IS. No. 10124/ 88 (ISI Marked) Part- 8 with latest amendment )
110 mm. dia 90 degree bend(cl-II) ( IS. No. 10124/ 88 (ISI Marked) Part- 8 with latest amendment)
140 mm. dia IS. NO. 10124/ 88(ISI Marked) Part- 4 with latest amendment End cap.
110 mm.dia IS.NO.10124/88 (ISI Marked) Part-4 with latest amendment.PVC End Cap.(Cl-III)
110 mm. dia ( IS. No 10124/88(ISI Marked) Part- 6 with latest amendment) F.T.P.(Cl-II)
140 mm. dia ( IS. No 10124/88(ISI Marked) Part- 6 with latest amendment) F.T.P.(Cl-II)
ISI marked P.V.C.Flexible Hose pipe as per IS 15265 - 100 mm dia (ISI Marked)
Solvent cement extra (Medium duty) IS-14182
G.I. Tripod Set and Inlet & Outlet Pipe Fittings (As per drawing) All Material ISI marked.
100 mm dia G.I E.R.W. Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971(ISI Marked), table 17 Specification.
150 mm dia G.I E.R.W. Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971 (ISI Marked), table 17 Specification.]
Supply of 150 mm dia C.I. Sluice valve with Hand wheel for water work as purpose confirming to ISI : 14846/2000 (ISI Marked) with latest ammendments. Parts of the valve shall be manufacture from basic materils and the valves should be tested for (Closed end test ) against Hydrostatic test requirement.
100 mm dia C.I. Sluice Valve I.S.I. 14846/2000 (ISI Marked) Amd No. 1&2 mark and specification PN- 1.6 sluice valve .
Supply and transportation of 100 mm dia Alfa Alfa type Valve as per the following technical Specifications and drawing:- 1.Spindle (Sq RH Thread) -S.S(410) 2.Top Cover:-G.I with 6 Nos Nut and Bolt 3.Body:-C.I( Grey FG 200,IS:210/78) 4.Galnd,Valve Seat:FG 200 The valve to be painted with one coat of Red Oxide primer and two coats of black japan paint.
Foundation Bolt for Drop Pipe of Distribution Chember& engine manufactured from 20 mm nominal diameter M.S Rod as per IS 2062/1992. Total length of Bolt is 375+10 mm in length & 20 mm in nominal diameter with Nut & 2 Nos Washer (As per Anexure-E) theaverage weight of such Bolt. 1.5 Kg per bolt with tolerance in weight of each Bolt @ +/-10%.(Drop Pipe) & 1 kg for engine)
Suply of G.I Hexagonal Head Bolts & Nuts conforming to IS : 1363 (Part-I)/ 1992 of product Grade-C with latest amendments for Bolts & IS: 1363 (Part-3)/ 1992 of Product Grade-C with latest amendments for Nutrs Properties / class for Bolt - 4,6 & for Nut-4.5.
Foot valve leather washer 100mm dia
Supply and transportation 100 mm dia, 2 mm thick, 30 mm width M.S. Heavy duty Hose Clamp fitted with bolt & nuts.
Compresed Asbestos fibre jointing for Quadruped & Tripod set ( for raised surface of Flange as per IS-6392) 300mm.dia(Table-5)
Supply & transport of Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to IS: 638/79 with ISI mark with latest ammendments suitable for raised surface of MS Flange as per IS: 6392/71 (Table-5,11 &17)
150 mm dia Ruber Insertion(Table-17)
150 mm dia Ruber Insertion(Table-5)
100 mm dia Ruber Insertion(Table-17)
80 mm dia Ruber Insertion (Table-17)
125mm dia Ruber Insertion (Table-17)
65 mm dia Ruber Insertion (Table-17)
80X65mm M.S. flanged reducer
100X80mm M.S. flanged reducer
Supply of 150mm dia. G.I 90 Degree MS bend both end flanged conforming to IS 1239(Part-2)/2011 (ISI Marked) and Galvanization as per IS 4736 with latest amendments thereof (4.8mm thick wall thickness)
Supply of Dia 100mm C.I Tail Piece one end flanged other end grooved, overall length:(175+15)mm with 7 nos Groove
3C X 4 sqmm copper cable conforming to IS 694 (ISI Marked)
2 X 3C X 2.5 sqmm copper cable conforming to IS 694 in 25 mm GI conduit (ISI-Medium quality) (ISI Marked)
Installation of Solar Photovoltaic Installation for Water Pumping System of Solar MINI RLI Scheme
Solar Module: Supply , transpot , installation and commissioning of ISI marked Solar Modules as per following specification: 1. Cell : Indigenous mono crystalline silicon SPV cells 2. Solar Module : Monocrystalline cell with PERC technology / module with bifacial cell . 3. Standards ISI marked as per IS 14286 and having certification of IEC 61853(1), 61730(1&2), 61710. 4. Modules must qualify to IS 170210 (Part 1) 5. Min. Efficiency : 19.5% . 6. Fill factor : More than 75% . 7. Module wattage mismatch in the SPV array within + 3% 8. Wattage output warranty : should not be less than 90% at the end of 10 years and 80% at the end of 25 years . 9 . The power output of individual PV modules used in the PV array , under STC : minimum 300 Wp , Necessary test certificates also to be supplied . For detail information please see CI. no 2.1 of technical specification . (d) For 5 HP Off-grid /On-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/ Bifacial SPV modules(5400-5800)Wp - 5400 Wp. (2X 6X550 +2 X 4X 550 Wp)
Power conditioning unit with enclosure : Supply,transport,installation and commissioning of Solar Power conditioning Unit consisting of following components and features:- 1)VariablefrequencyDrive with inbuilt MPPT,voltage range suitablefor operating pump-motorset of1HP to 20HP,detail mentioned in cl 6.1. 2) Power input :DC source for 1HP, 2HP and 3HP. 3) Power input : AC / DC source or hybrid for 5HP and above. 4)Incomer: DC MCB 2 Pole16 amp upto 5.0 HP,,25 amp for 7.5HPand10HP,40amp for15 to 20HPas per IS/IEC60947-2. 5) Incomer:AC MCB 4 pole16amp for5.0 HP,25 amp for 7.5HPand10HP,40 amp for 15 to 20 HP as per IS/IEC60947- .6) Type II DC SPD of 40 KA. 7)Type II AC SPD of 40 KA for AC/ DC or Hybrid input. 8) Dual input (solar/Grid) 25amp changeover switch for 5HP and 7.5 HP, 40 amp for 10 HP, 63 amp for 15 to 20 HP 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote monitoring system. 12) Should have built –in EMC filters. 13) IP 65 glands for cable in and out. 14) Min. IP 54 enclosure. For detail features, protections, RMS,Communication architecture, Security,Data storage, tolerance of various parameters,standards to be qualified, etc.Please refer to Cl 6.1 of technical qualification. d) For 5 HP capacity Pump-motor set with DC input
Module Mounting Structure ( For 2HP, 3HP and 5HP Solar Water Pumping System): Supply, transportation & installation of G.I Manual tracking structure made of MS hollow <ecuons. pipes. plates, angles etc as per IS 4923,1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per or awing and specification of MNRE. The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be regulated to face the sun optimally. The weight of the Module Mounting Structure holding 4 Modules should not be less than 280Kgs, holding 6 Modules should not be less than 350 Kg
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing. a) For 6 Module Structure:2 Nos b) For 4 Module Structure:2 Nos
For 4 Module Mounting Structure
For 6 Module Mounting Structure
Cable and Accessories: Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5 m (for 1/2/3 hp) & 20 m (for 5/7.5/10/15/17.5/20 hp) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc (B) For 5 HP Per Structure
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. 5 & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By lSI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Lighting System at Scheme: (with lighting Pole) : Dusk to dawn lighting arrangement of at 4 mtre height above ground Level with Hot Dip Galvanized 80mmx50mm,medium duty pipe, with 12 V, 15Ah 2-in-1 Lithium ion/ Ferro- Phosphate battery with in-built 7-11 watt LED lamp, 50 Wp solar panel (Minimum 19 % Efficiency) to cover the scheme area. The lighting system should be warranted for 5 years from the date of installation.
b) Lightning protection (Pole mounted): Lightning protection with 3" X 1.5" G.I pipe of 6m + 1 m height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing)
Supply and installation of 3 phase AC electromotorpump-motor set with speed of 3000r.p.m (synchronous speed) suitable for Solar applications and shall have 60 months guarantee for the following conditions including loading,unloading, transportationetc.:-(Refer technical specification for more detail) d) 5 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:- i) Monoblock Surface Pump-motor set ISI marked as per IS: 9079 for mini RLI scheme with discharge of 13.8 LPS at 18 mts. total head with 100 mm dia. reinforced PVC suction pipe (20 m) and delivery pipe (10 m), foot valve, nipple, priming bend, Cable and all other required accessories to complete connection of suction and delivery side.
Testing and commissioning of scheme after completion of all work
Comprehensive maintenance charges for 5 Years (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) For 5 HP both for Submersible & Surface pump Note: Total comprehensive maintenance charge is to be withheld in addition to Comprehensive maintenance charges will be released @ Rs. 0.60 per Wp per year at the end of each maintenance period i.e.at the end of 1st year,2nd year, 3rd year, 4th year, 5th year. In case the "Bidder" does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited.
Insurance @ 2% for Item No.2.01, 2.02, 2.08 & 2.10 for a period of 5 years. Note:2 Item 1st year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd ,4th & 5th year on production of Original Receipt of premium payment.
Supply fitting and fixing of Hot dip Galvanised ( min 80 micron) / Powder Coat painted M.S Kiosk Box / Stainless Steel Kiosk of SS304 of 800(L) X 500(W) X 650(H) and total height with legs is 950mm for mounting of motor-pump set including transportation, grouting in Cement Concrete as shown in drawing.
Remote monitoring for 5 years : Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic functions:a.Controller must be assigned with a unique serial number and its live statusmust be observed remotely on online portal through login credentials.b.Live statusmust indicate whether controller is ON/OFF.The parameters i.e.the water output,water flow rate,in fault condition,array input voltage/current,powerand motor frequency should at logged at an interval of 10 minutes c.Controller must have abackup tostore thedata locally(at least for1year),D.supply& installation of GSM/GPRS based DataTransmitter or Modem and to provide remote monitoring service to transmit the parameters tocentral server from the solar pumping system with time stamp at user-defined interval and report generation at the buyer end. Note: - Charges of remote monitoring will be withheld and released after successful completion of comprehensive maintenance period for 5 Years.
Cleaning and washing of modules once in a month with clear water to remove deposited dust and dirt on the module surface and keep the modules clean throughout the year. The activity to be performed for eight months in a year excluding four monsoon months. A log book should be maintained at thr site for the said purpose. Note: - Charges of Cleaning and washing of modules of each Solar Structure of the Scheme for 8 Month/Year @Rs. 300/month(i.e. 40 Months X 4 Structures X 300/Month) will be withheld and released after completion of comprehensive maintenance period for 5 Years. Log Book will be issued by the respective Sub-Division.
Extra rate for transportation @ 2% for item no. 2.01,2.03 as applicable
Add GST @ 18% on sl. No.2.01to 2.17 ( Solar)
Add Labour Welfare Cess @ 1% on sl. No.2.01to 2.18 ( Solar)
Laying Water Transmission Arrangement of Solar Mini RLI Scheme.
Earth work in excavation of field trenches as per designed section & allignment for laying of pipe lines (PVC, RCC, ACP etc) upto a depth of 1500 mm in all sorts of soils including removing spreading or stacking extra earth as directed. The item includes necessary trimming of sides trenches, levelling, dressing and ramming the bottom as required complete.
Laying of PVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipesfittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge
i)140 mm. dia
ii)110 mm. dia
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. B) River Bazree.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m. (i) Tor steel/Mild Steel. II) JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor) [Excluding cost of chipping over concrete surface]. (ii) With 1:4 cement mortar.(b) 15 mm thick plaster.
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
Earth work in filling in trenches after laying pipelines (PVC, RCC, ACP etc) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering & ramming etc. Layer by Layer complete. (Payment will be made on the basis of measurement of finished quantity of work)
Erection, fitting, fixing of set of M S Tripod inlet and outlet pipe fittings for Mini RLI Scheme.(Rate inclusive of transportation from departmental store to work site).
Labour charges for fitting, fixing 110 mm dia Alfa-Alfa valve with 140 mm dia class-II, UPVC riser pipe with the help of FTP (flanged tail piece) by joining the PVC end of the tail piece and riser pipe with coupler and flanged end of tail piece Each and Flap valve with rubber insertion, nuts and bolts etc complete.(Rate inclusive of transportation from departmental store to work site).
Testing of pipe line system against leakage by fillinh the distribution chamber with water and supplying water through the entire pipe line net work for atleast 4 (Four) hours including hiring and transport of suitable generstor , pump , tools and plants, fuel and lubricants and installation of the pump connecting the same with pipe line network making necessary electrical connection and dismantling all these after completion of test all complete as per direclion cf Engineer -in - Charge. For MINI RLI.
Labour charges for fitting, fixing (150 x 140) mm dia M S reducer with 140 mm dia UPVC pipe with the help of FTP (flanged tail piece) by joining the PVC end of the tail piece and 140 mm dia UPVC pipe with coupler and flanged end of tail piece and expander with rubber insertion, nuts and bolts etc. complete. (Rate inclusive of transportation from departmental store to work site).
Supplying, fitting and fixing including transportation of Sign board of MS fabricated Structure Sheet Size 2 m x 1 m x 1.5 mm thick, MS flat bar (40 mm x 6 mm) welded with frame with 2 nos. MS Angle post (45 mm x45 mmx6mm) of 2.44 m length embeded 0.6 m into 1:2:4 Cement Concrete pasting flex on the MS Sheet ( 2 m x 1 m) as approved signage. This will include Civil construction works of foundation, Painting , material , fitting fixing and labour complete as per Drawing and direction of EIC.
Supply and fixing on the wall Black Granite Stone Falak with necessaary lettering with golden Colour in size:90cm x 60cm as per direction of EIC
Supplying,fitting & fixing granite slab 15mm to18mm thick in wall etc. over 20mm(avg) thick base of cement morter(1:2) laid with white cement slurry @4.40 Kg per Square meter before placing of granite and jointed with white cement [email protected] Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge includingcost of all materials, labours, curing and roughening of concrete surface complete (a) Area of each Granite slab upto 0.60 Square meter. Note:The Item is used for Installation of Black Granite Falak required during HCM Foundation/Inaugration Programme at the Solar MINI RLI Scheme
Painting and Engraving block letters or digits in Black Japan or any approved paint on the Black Granite Stone Falak as per direction d) Size above 5 cm. and upto 7.5 cm.
f) Size above 10 cm. and upto 12.5 cm.
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete. In Foundation and Plinth for Black Granite Stone Falak
Supplying 1 m × 0.6 m × 24 swg MS board containing list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.
xxviii)100mm /150mm. dia. C.I. sluice valve.
(i)(b) 100 mm dia. NB ERW/MS Pipes
(i)(b) 150 mm dia. ERW Pipes
Extra rates carriage 4% allowed for all except item no 3.01,3.10&3.13
Add GST @18% on sl. No.3.01 to 3.20 ( WTA)
Add Labour Welfare Cess @ 1% on sl. No.3.01 to 3.21 ( WTA)
Institutional Development & Capacity building of Water Users Association of Solar Mini RLI Scheme(Items those are not completed at the time execution of the scheme will be withheld as additional security Deposite. Said items will be released after completion of the component and certification from the respective Assistant Engineer)
Campaigining in the command area of Mini RLI Sub-project by community workers for mass awareness,capacity building to achieve sustainability of Sub-projects.Cost include wage payment to community workers,transportation,leaflet etc. Note- Charge of campaigning is to be paid on production of good quality of photograph of thecampainging with beneficiaries
Meeting Cost for WUA formation,cost including Refreshment,Training materials,transport local conveyance,wage payment to community worker,renumeration to resource person and incidental charges
Registration Cost for WUA under suitable act(Society) deed writing including registration charges,Conveyance Costs & Opening of Bank A/C etc
Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge (rate on meeting). One training immediately after formation of WUA & remaining 03 nos training from each season Kharif, Aman & Rabi). Note: Charge of 1st training is to be paid on production of attendence sheet of the training, remaining 3 nos training charges will be released after completion of 1 year with security deposit on production of attendence sheets of remaining 3 nos training. In case the "Bidder" does not provide service during the maintanance period, the amount so held up will be forfeited.
Meeting and Onsite demonstration for operation & maintenance of one Mini RLI water management and mode of Collection of Water Tax,building of Corpus Fund etc
IEC Materials (Leaflet,poster,notebook)=8 meetings for Sl No4.0 2 and Sl -4.04
Documentation Cost for activities of WUA Scheme by still photography,report booklet etc in both hard and Soft Copy
Impact study & monitoring of scheme by site visit of 2 Community Workers during 3 years period Note:- charges of all impact study and monitoring to be withheld in addition to security deposit and will be released after completion of the 03 year.
Add GST @18% on sl. No.4.01 to 4.09 ( WUA)
Please Enable Macros to View BoQ information
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.75 MB
Tendernotice_2.pdf
PDF • 9.90 MB
Tendernotice_3.pdf
PDF • 9.86 MB
Tendernotice_4.pdf
PDF • 10.13 MB
Tendernotice_5.pdf
PDF • 3.39 MB
Tendernotice_6.pdf
PDF • 4.68 MB
BOQ_2439389.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid