Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹35.3 L+₹43,312 (1.24%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹35.9 L+₹98,507 (2.82%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹37.3 L+₹2.4 L (6.84%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹38.3 L
EMD Value
₹76,540
Closing Date
18 Nov 2021, 6:00 pmClosed
GE (AF) Jammu
Air Force Station Jammu
CA NO GE/AFJ-39/2021-22 SPL REPAIR/REPLACEMENT TO RPA TECH FIT HANGER DOOR,ACCESSORIES AND FALSE CEILING AT AF STATION JAMMU
2021_MES_482994_1
CA NO GE/AFJ-39/2021-22
Open Tender
Civil Works
Item Rate
330 days
GE (AF) Jammu
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Jammu
₹76,540
Yes
23 Feb 2022
21 Oct 2021
20 Nov 2021
21 Oct 2021
18 Nov 2021
4 Nov 2021
Amount
Dismantling and removal of all structural steel work including doors, gates, rails, etc complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removing demolished material to a distance and depositing to the distance exceeding 50 metres but not exceeding 100 mitres where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Removing excavated materials n.exc 250m and deposing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking down & Refixing door shutter exc. 2 sq.m each compete all as specified and directed by engineer-in -charge.
S & F structural steel for framed work as in doors or gates of anglesor other section with gusset plates,rails, braces,etc., complete,drilled for fixing of steel sheeting or other covering.Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanges or steel hanging door fittings (exclusive of steel sheeting or other covering, runnig rails and guides) and hanging,also fastening and fixing Fe 410 -W (Gde- E- 250) quality- A all as specified and directed.
S & F structural steel for joist, channel ,angle or tee sections fixed independently, without connecting,etc. independentely plates, and fixing fe 410-w(Gde-E-250) quality -a all as specified and directed.
S&F 300mmx 75mm bottom wheel with necessary arrangement like MS plates nuts etc. to fixing wheel complete all as specified and directed.
S&F 100mmx 40mm bottom wheel with necessary arrangement like MS plates nuts etc. to fixing wheel complete all as specified and directed.
M/L for two coats of synthetic enamel painting comouflage pattern to steel surfaces over a coat of red oxide incl preparation of steel surfaces complete all as specified and directed.
M&L cement concrete type D2 1:4:8(40mm graded stone aggregate as in foundations ,filling mass concrete etc.complete all as specified and directed.
M & L PQC cement concrete work with minimum flexural strength 40kg per Sq cm in field using 400 kg of cement per cum thickeness of concrete 25cm or less non circlular synthetic fibre complete all as specified and directed by Engineer-in- Charge.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof all as specified.
S &F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw as specified. Confirming ISI complete all as specified and directed by Engineer-in- Charge.
S &F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.60mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw as specified. Confirming ISI complete all as specified and directed by Engineer-in- Charge.
Dismantling Wall and ceiling boards(fib pulp,insulation ,etc) or insultion boards/slabs/blankets, any thickness, including cover fillets, all as specified.
M&L Elegent Tile made of perforated cement fiber composite 595x595/295x1195x5 mm covered with absorptive microfiber coating on the front side and acoustic fiber on the back side, water resistance absorption coefficient upto 0.89 at 160Hz tested as pe ISO 354. The tiles are anti-sag and installed on T24 grid system of 0.6 mm thick Main 'T' of length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, wire support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per fire retardant IS 15061-2002 for excellent results.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,drains etc, but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 with old size bricks complete all as specified and directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:4), complete all as specified and directed .
M&L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection incl finishing the surface even and smooth w/o using extra cement all as specified and directed.
Preparation of newly plastered surfaces of walls upto 30 mtr height,and applying two coats of exterior quality paint over one coat of primer. Make: Asian Ultima protek/ Nerolac excel Base coat with Excel top guard offering ten years guarantee can bridge 3mm crack / Berger Paint weather Coat long life 10 with seal-o-Prime primer (with RGB value in SIGMA Pattern) in any tint on melbow width like roof projection, facia, Chhajja etc) all as per manufacturer's instructions and complete all as specified and directed by Engineer-in-Charge as per Pattern approved by USER's for the Comflage pattern.
Three component epoxy polyurethane self levelling antistatic dissipative flooring system laid in overall thickness min 3mm (anti-static in 5x5 metre grid) comprising of 200 microns thick priming coat followed by 2mm thick base coat and 1mm thick top coat complete all as specified and as directed. NOTES:- 1.Epoxy colour theme will be decided by GE consultation with user. 2. Marking of yellow lines at designated place will be included in quoted rates. 3. The laying of the EPU flooring is to be done by only the authorized Applicator of any of the listed brands in PS Clause 16.1 on serial page no.80(A) and approval for the same is to be taken from the Garrison Engineer before start of work. 4.The defects liability Period of EPU flooring shall be 3yrs .A sum equal to 5% (Five Percent) of the amount of EPU Flooring in the BOQ will be held back out.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and directed by Engineer-in-Charge.
E/M PART
Taking down carefully copper/aluminium point wiring (light, fan,bell, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through existing PVC conduit concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coated of suitable size with 3 mm thick laminated sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
(a) For one light point controlled by one SP switch
(b) For one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per Srl item No. 26 here-in-before but for one 3 pin 5 Amps socket out let point on the same board controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per item No-26 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size complete all as specified and directed by Engr-in-Charge. .
All as per item No-26 above but for one 3 pin socket out let, 16 Amps on Independent board with the cable 2.5 Sqmm size complete all as specified and directed by Engr-in-Charge. .
S/F socket outlet 5 pin, 6 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S/F socket outlet 6 pin, 16 amps (Multi pin) flush type complete all as specified and as directed by Engineer-in-Charge.
S&F switch piano flush button type 6 amps single pole one way complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush button type 16 amps single pole one way complete all as specified and directed by Engr-in-Charge. .
S&F ceiling rose surface bakelite 2 to 3 terminals 65 x 50mm complete all as specified and as directed by Engineer-in-Charge.
S&F of lamp holder insulated body with back plate for batten fitting including LED bulb 12 watt (SSK-PAG-N-12W)complete all as specified and directed by Engineer-in-Charge.
S&F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 20 watt suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.Make:- Havells Cat Part No : LUMILINEBS20WLED865SPCWH or equivallent make of Crompton Greaves/ Philips/Bajaj.
Supply and fixing LED panel 2 feet x 2 feet , 36 watt suitable for indoorrecess mounting complete with inbuilt driver including all fittings prewired with copper cable of suitable size. Cat No VENUSNEOHE2X2PLR18-42WLED830MOD Make Havells or Equivalent make of Syska/C&S
S&F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 08/10 watt suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.Make:- Cat No : LUMILINEBS9WLED865SPCWH of HavellsCrompton Greaves/ Philips/Bajaj/Havells.
Taking down existing exhaust fan/ ceiling fan any size with due care and refixing with new lok bolt (where required) after servicing and painting including connecting electrically using PVC insulated overall sheathed flexible copper conductor cable 0.75 mm all as required and directed.
Supply and fix stepped type electronic fan regulator flush type on the phenolic laminated sheet etc as required.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 06 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth duly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Conduit will be measured and paid separately.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 04 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth duly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Conduit will be measured and paid separately.
S & F rigid non metalic PVC conduit 25 mm exclusives of boxes but incl all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc.
S & F rigid non metalic PVC conduit 20 mm exclusives of boxes but incl all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc.
Distribution board iron clad TPN DB, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar. Make-Legrand Cat pt No 5077 30 or equivalent of make L&T / Merlin Gerin multi-9 complete with one MCCB 4 pole 415 Volts 125 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. (Note: MCB's and MCCB will be measured and paid seperately under relevent items)
S&F sheet metal enclosures for MCBs, single pole and neutral, 08 ways 240 Volts double door type complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 6 to 32 Amps, 240 Volts complete.
S&F MCB SPN upto 32 Amps ,240 Volts complete.
S&F MCCB TPN 125 Amps ,415 Volts complete cat No 4200 96 of legrand
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
S & F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amp Complete
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
ADITYA CONSTRUCTIONS
ANIKET TRADERS
bamral builder
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .