| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹26.2 L+₹2.6 L (11.2%)Rejected-Finance 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹27.2 L+₹3.6 L (15.3%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹29.9 L+₹6.3 L (26.7%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹30.8 L+₹7.2 L (30.7%)Rejected-Finance 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
23 Oct 2023, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR TO ELECTRIC WATER HEATERS SOLAR WATER HEATERS AND REPAIR/MAINT OF INTERNAL ELECTRIFICATION SUBMIAN WIRING SERVICE CONNECTIONS AND CONNECTED E/M ITEMS UNDER GE (EAST) MATHURA
2023_MES_619843_1
8200-1393/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EAST MATHURA
₹1 L
18 Nov 2023
21 Sept 2023
25 Oct 2023
21 Sept 2023
23 Oct 2023
9 Oct 2023
21 Sept 2023 - 16 Oct 2023
Amount
Taking down carefully aluminum/copper point wiring (light, fan, socket or power, bell etc) complete, including fixtures & fittings such as switches ceiling rose, socket, Pendent, regulator, light fittings etc and removing the material from site for taking credit (credit for these items) should be made as per credit schedule) and making good the disturbed surfaces of walls ceiling etc complete all as specified and as directed.
Taking down old/burn Submain wiring of any type and size complete and making good disturbed sufaces to match with the existing surfaces complete all as specified and as directed.
Taking down old unserviceable existing SPN/TPN DBs / enclousers any size and type/any descriptions and making good disturbed surface of walls as to match the existing surface complete all as specified and as directed.
M & L for Sub Main wiring with two runs single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 20mm dia) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 4 Sqmm copper conductor cable (FRLS) green colour as earth wire complete all as specified and as directed. Note : Two runs of 4 Sq mm (P&N), one run of 4 Sq mm earth wire & One run of PVC conduit will be measured as one RM).
M & L for Sub Main wiring with two runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 6 Sqmm copper conductor cable (FRLS) green colour as earth wire complete all as specified and as directed. Note: Two runs of 6 Sq mm (P&N), one run of 6 Sq mm earth wire & One run of PVC conduit will measured as one RM.
M & L for Sub Main wiring with two runs single core 10 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 10 Sqmm copper conductor cable (FRLS) green colour as earth wire complete all as specified and as directed. Make : Havells/Polycab/RR Kable/Gloster Note : Two runs of 10 Sq mm (P&N), one run of 10 Sq mm earth wire & One run of PVC conduit will measured as one RM.
S&F in replacement TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder coated with bus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way including fitting suitable for MCBs with connections complete all as specified and as directed.
Supply & fixing powder coated CRCA steel sheet enclosure for MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 100 Amps rated copper bus bar, 415 volt complete all as specified and as directed. Make : Havells/L&T/Simens/Schenieder
Supply & Fix in replacement of MCCB 160 Amp rating, (ICS=100% of ICU) 4 pole 415V, breaking capacity 25KA complete all as specified and as directed.
Supply & fix in replacement of MCCB 125 Amps, bracking capacity 16 KA, 4 Pole, 415V complete all as specified and as directed.
Supply & fixing in replacement MCCB 100 Amps, breaking capacity 16KA, 4 Pole, 415V complete all as specified and as directed.
M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, 1100 volts grade copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases (making good all to the disturbed surfaces to match the existing surface) including with modular flush metal boxes with modular cover plates & frame for mounting modular switches, sockets, regulators etc including sunk cast iron/pressed steel/terminal boxed for mounting flush tuype switches/sockets etc with 3mm thick phenolic laminated sheet covers and including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified and as directed for the following:-
One light/ fan point controlled by one way switch 5 amp complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on the same board with other switches complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on independent board complete all as specified and as directed.
One bell point controlled by one push button on independent board complete all as specified and as directed.
One light point controlled by two way switch complete all as specified and as directed.
All as per item No 12.00 here-in-before but for 3 pin/5 pin 16 Amps sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent Point wiring complete all as specified and as directed .
Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete all as specified and as directed.
Supply and Fixing Modular bell Push switch 6 Amps with indicator single pole one-way, 1 Module complete all as specified and as directed.
Supply and Fixing Modular switch 16 Amp single pole one way,1 Module complete all as specified and as directed.
Supply & Fixing Modular fan Regulator electronic step type complete all as specified and as directed.
Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified and as directed.
Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified and as directed.
Supply and Fixing Modular switch 6 Amps single pole two-way, 1 Module complete all as specified and as directed.
S&F in repair switch piano flush type, SP, one way, 5 Amps complete all as specified and as directed.
Supply and fixing in repair socket out let 2 in 1, 5 pin 5 Amp flush type complete all as specified and as directed.
S&F in repair socket out let 2 in 1, 3 pin 5 & 16 Amp flush type complete all as specified and as directed.
S&F in repair switch piano flush type 15 Amp, SP, one way complete all as specified and as directed.
S&F in repair bell push flush type, SP, one way, 5 Amps complete all as specified and as directed.
S&F in repair ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
S&F in repair lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair mini enclosure including DP MCB 16 Amp, 'C' curve type complete all as specified and as directed.
S&F in repair Bell Ding dong type, AC 230 Volts including connections complete all as specified and as directed.
S&F in repair step type electronic fan Regulator piano flush type (switch/socket type as per existing) phenolic laminated sheet etc as required complete all as specified and as directed.
S&F in repair indoor decorative ultra slim surface/Wall mounted LED batten tube light fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired with and including 1 x 20 watt LED tube and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply & fixing in repair indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light fitting 9 watt with LED Tube (size within 600x25x40 mm) suitable for mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K,>100Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair LED Bulk Head light fitting with PDC aluminium housing and milky diffuser capacity 10 Watt complete with all accessories and connection complete all as specified and as directed.
S&F in repair LED 9W, suitable for Base Cap B22 type holder complete all as specified and as directed.
S&F in repair LED 7W, suitable for Base Cap E14 type holder complete all as specified and as directed.
S&F in repair 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connections complete all as specified and as directed. Make : Make : Havells/CG/Philips/Wipro/Syska/Bajaj/C&S.
S&F in repair recess type, 36/34 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver, energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply & fixing in repair indoor wall mounted fitting, brushed nickel finish fixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts complete all as specified and as directed.
S&F in repair LED Post top light fitting 30 Watt IP-65 rated complete all as specified and as directed.
S&F in repair LED Round/square recess mounted slim downlighter 12 watt, 6500K, integrated electronic driver, natural white complete all as specified and as directed.
S&F in repair LED Round/square recess mounted slim downlighter 18 watt, 6500K, integrated electronic driver, natural white complete all as specified and as directed.
M&L for security light bracket made out of 40mm dia light grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole/wall including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including two coats of aluminium paint over a coating of red oxide primer including taking down old unserviceable bracket of any size/description complete all as specified and as directed.
S&F in repair MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F in repair MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F in repair MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F in replacement MCB SPN 63 Amps,' C' series, breacking capacity 10KA, 240V complete all as specified and as directed.
S&F in replacement of MCB SPN 40 Amps,' C' series, bracking capacity 10KA, 240V complete all as specified and as directed.
S&F in replacement of MCB SPN 6-32 Amps,' C' series , bracking cap 10KA, 240V complete all as specified and as directed.
S&F in replacement of MCB SP 6 - 32 Amps, 'C' series, bracking cap 10KA, 240V complete all as specified and as directed.
S&F in repair SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts with all connection complete all as specified and as directed.
S&F in repair metal clad plug top and SPN MCB of rating 20 Amps, 240 Volts for fixing on AC box complete all as specified and as directed.
Supply & Fix modular MCB DP 16 Amps, 'C' series, bracking cap 10KA, 240V complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 1 / 2 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 3 / 4 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 6 / 8 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
Supply & replacement of 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch/socket and complete connection all as directed. Note :- Replacement of unserviceable switch/socket/regulator shall be measured & Paid separately under relevent item of this BOQ.
Supply & replacement of 3 mm thick laminated mica sheet top cover suitable for switch board 8 way to 12 way including removing & re-fixing of existing switch/ socket and connection complete all as specified and as directed. Note :- Replacement of unserviceable switch/socket/regulator shall be measured & Paid separately under relevent item of this BOQ.
S&F Modular metal flush box 1/2 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 3 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 4 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 6 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 8 Module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 1/2 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 3 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 4 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 6 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 8 module complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces ( making good all to the disturbed surfaces as per existing) including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing including gang box / 2.0mm thick MS terminal box as per site requirement for fixing switches, sockets, fan regulators etc fixed to wall with 3mm thick laminated sheet top cover complete all as specified and as directed for the following:-
One light point/ fan point / bell point controlled by one switch complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way switch on same board complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one switch on independent board complete all as specified and as directed.
All as per item No. 68.00 here-in-before but with 4.0 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
Supply and Fixing switch piano type, SP, one way, flush type 5 Amps complete all as specified and as directed.
Supply and Fixing socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified and as directed.
Supply and Fixing socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified and as directed.
Supply and Fixing switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F fan Regulator piano flush type, electronic step type complete all as specified and as directed.
S&F in repair Modular switch 6 Amps single pole one-way, 1 Module complete all as specified and as directed.
S&F in repair Modular switch 16 Amps single pole one-way, 1 Module complete all as specified and as directed.
S&F in repair Modular fan Regulator electronic step type complete all as specified and as directed.
Supply and Fixing in repair Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified and as directed.
Supply and Fixing in repair Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified and as directed.
S&F SP enclosure Modular type, with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amp, 240V complete all as specified and as directed.
S&F SP enclosure Modular type, with a two pin and earth plug and socket complete with one single pole MCB of rating 16 Amp, 240V complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches/duct/fixing on walls/poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole/Main Panel Box and testing complete including taking down old unserviceable cable all as specified and directed of following sizes :- Note:- HDPE pipe rate shall be deemed in quoted rate above.
10 sqmm 2 core
16 sqmm 4 core
25 sqmm 4 core
Earthing complete all shown as electrical plate No -03 of MES Sch part -I as specified and as directed including the following:- (i) GI earth plate of size 60x 60cm x6.0mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.50 metres below ground level. (ii) Earth plate surrounded by and packed with charcoal and common salt in alternative layers. ( n.exc 15 cms each layer) (iii) 4 mm GI wire from earth plate to MCB DB/machinery incl necessary GI bolts, nuts check , washers, thimbles etc. (iv) 20 mm bore, light grade, Gi pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontaly to the earth pit. (v) 15 mm dia bore G. I. medium grade pipe for protection of earth wire. (vi) Cement concrete chamber of PCC (1:3:6) type C-2 using 40mm graded stone aggregate. The chamber shall be constructed one metre away from edge of earth pit. (vii) 50 mm thick precast cover of reinforced cement concrete(1:2:4) type B-1 using 20mm graded stone aggregate with steel rainforcement 8 mm dia mild steel TMT bar @ 10 Cm c/c both ways and MS angle iron 50x50x6mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces with suitable handle to lift the cover. (viii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance of 50 m as directed.
Disconnecting water and electric connection in existing position of geyser and taking down geysers fixed to wall at any height by its own arrangement and repair/replacement of unservicable parts of geyser and same will be fixed at existing position after repair and testing at site/workshop complete all as specified and as directed. Note : (i) The spare parts will be measured and paid separateley against appropriate items of BOQ. (ii) Contractor will attend/resolve complaint within 48 hours. (iii) The contractor should provide suitable manpower and equipment for attending of daily basis complaint and carry unservicable /serviceable geysers to the work site & AGE E/M office or vice versa and rate should be deemded in the quotated rate.
Geyser of 3 Ltrs capacity
Geyser of 25 Ltrs capacity.
Geyser of 50 Ltrs capacity
Supply & fixing in replacement of inner tank for geyser cap 3 ltr of Steel sheeting for geyser as per existing complete all as specified and as directed.
Supply & fixing in replacement of inner tank for geyser cap 50 ltr of Steel sheeting for geyser as per existing complete all as specified and as directed.
Supply & fixing in replacement of unserviceable outer body/cover suitable for 3 ltr storage type water heater (geyser) vertical type outer ABS rust free body, glass lined inner steel walled tank as per existing complete all as specified and as directed.
Supply & fixing in replacement of unserviceable outer body/cover suitable for 50 ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 22 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer complete all as specified and as directed.
Supply & fixing in replacement of Geyser water assembly of Stainless steel heavy duty suitable for 50 Ltr electric water heaters complete all as specified and as directed.
S&F in repair of MS top cover of 22 gauges, ISI marked suitable for 50 Ltr capacity electric water heaters complete all as specified and as directed.
S & F in repair of MS bottom cover/plate of 22 gauges, ISI marked suitable for 50 Ltr capacity electric water heaters complete all as specified and as directed.
Supply and Fix in replacement of water heater storage type electric 50 ltr capacity, BEE 5 Star rated complete all as specified and as directed.
Supply & fixing in replacement of inner tank for geyser cap 25 ltr of Steel sheeting for geyser as per existing complete all as specified and as directed.
Supply & fixing in replacement of unserviceable outer body/cover suitable for 25ltr cap geysor made out of mild steel pre-treated and stove enamelled sheet of 22 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer complete all as specified and as directed.
Supply & fixing in replacement of unserviceable heating element, 240 Volt with rubber washer cap 1.5 KW (round or triangualr) any type complete all as specified and as directed. Make : Theeta/Micron/Racold/Daspass/Bajaj
Supply & fixing in replacement of unserviceable heating element, 240 Volt with rubber washer cap 1.5 KW. (round or triangular) suitable for Recold model andrisuno 25, white/blue of 25 Ltr capacity complete all as specified and as directed. Make : Theeta/Micron/Racold/Daspass/Bajaj
Supply & fixing in replacement of unserviceable heating element, 240 Volt with rubber washer ('O' ring) cap 2.0 KW. (round or triangular) for ESSCO geyser type zgw-001 model capacity 25 Ltrs complete all as specified and as directed. Make : Theeta/Micron/Racold/Daspass/Bajaj
Supply & fixing in replacement of unserviceable heating element, 230 Volt with rubber washer cap 2.0 KW. (round or triangular) suitable for Crompton Model CM/L-8158279, white/blue of 25 Ltrs capacity complete all as specified and as directed. Make : Theeta/Micron/Racold/Daspass/Bajaj/Crompton
Supply & fixing in replacement of unserviceable thermostat 30°C to 70°C, ISI marked, rated current 10-15 Amp, 230 Volts suitable for Geyser 50 Ltr/25 Ltr complete all as specified and as directed. Make : Bajaj/Venus/Theeta
S & F in repair of MS top cover of 22 gauges, ISI marked complete suitable for 25 Ltr capacity electric water heaters complete all as specified and as directed. Make : Bajaj/Recold/Ritz
S & F in repair of MS bottom cover/plate of 22 gauges, ISI marked complete suitable for 25 Ltr capacity electric water heaters complete all as specified and as directed. Make : Bajaj/Recold/Ritz
Supply & fixing in replacement of Geyser water assembly of Stainless steel heavy duty suitable for 25 Ltr electric water heaters complete all as specified and as directed. Make : Bajaj/Recold/Ritz
Supply & fixing in replacement of unserviceable indicator bulb neon round/square type single phase 230 volt complete all as specified and as directed.
Supply & fixing in replacement of unserviceable Safety plug 15mm (brass) for geyser cap 25/50 Ltr complete all as specified and as directed.
Supply & fixing in replacement of unserviceable PVC flexible inlet outlet connection 15mm dia, 45cm long with brass nuts bolts and washers etc complete all as specified and as directed.
Supply & fixing in replacement of unserviceable PVC flexible inlet outlet connection 15mm dia, 60cm long with brass nuts bolts and washers etc complete all as specified and as directed.
Supply & fixing in replacement of unserviceable/damaged glass wool complete all as specified and as directed.
Supply & fixing in replacement of safety Valve for Suitable Cap of 25/50Ltr cap Geyser complete all as specified and as directed.
M&L for grouting the fastner bolt of size 6"x1/2" with nut in wall in repairs for fixing the geysers complete all as specified and as directed.
M & L for painting of electric water heater 50 Ltr capacity with super enameller paint of white colour including preparation of old painted surfaces including writing of MES No complete all as specified and as directed.
M&L for painting of electric water heater 25 Ltr capacity with super enameller paint of white colour including preparation of old painted surfaces including writing of MES No complete all as specified and as directed.
Supply & fixing in replacement of unserviceable thermostat 30°C to 70°C, ISI marked, rated current 10-15 Amp, 230 Volts suitable for Geyser 3 Ltr complete all as specified and as directed. Make : Bajaj/Venus/Theeta
Supply & fixing in replacement of unserviceable heating element ,240 Volt with rubber washer ('O' ring) cap 2.0 KW. (round or triangular) for 3 Ltr instant geyser any type complete all as specified and as directed. Make : Theeta/Micron/Racold/Daspass/Bajaj
Supply & fixing in replacement of Geyser water assembly of Stainless steel heavy duty suitable for 3 Ltr electric water heaters complete all as specified and as directed.
S&F in replacement of unserviceable plug and socket in sheet metal enclosures with two pin and earth plug and socket complete with and including MCB SP 20 Amps 240 volts heavy duty etc complete all as specified and as directed.
Supply and Fixing in replacement of unserviceable plug top 3 pin 15 Amp for geyser conncetion complete all as specified and as directed.
Supply and Fixing metal clad plug top 3 pin 15 Amp for geyser conncetion complete all as all as specified and directed.
S&F one switch and one socket semi flush type 5 PIN 15 Amp 230 volts AC complete all as specified and as directed.
S&F in replacement of PVC insulated sheathed 1100 volts grade ISI marked copper conductor cable of size 1.5 sqmm 3 core complete all as specified and as directed.
Supply and fix in replacement of MCB SP 10-32 Amp 230 volt complete all as specified and as directed.
M&L for sub main wiring with copper conductor two run single core stranded 1100 volt grade 2.5 sqmm ISI marked drawn in PVC conduit of 20 mm dia including earth wire of green colour 2.5 sqmm conductor multi stranded FR complete all as specified and as directed.
M&L for submain wiring with Two runs of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor FR PVC insulated unsheathed cables conforming to IS : 694 drawn through and including concealed in wall rigid medium duty unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and accessorie all conforming to IS specification complete all as specified and as directed.
Providing labour for servicing and maintenance of complete solar water heater plant of cap 500 LPD installed at single/double/triple storey bldgs for carrying out minor leakage, cleaning of flat plate collector glass & cleaning of sintex tank and make up tank, glass/metal tube incl dismantling inlet and out let connection and re-fixing the same after cleaning for proper functioning to maintain proper water temperature, complete all as specified and as directed. Note .Contractor should maintain the repair system complete area qtr as and when required.
All as per item Serial No 126.00 here in before but for solar water heater plant of capacity 300/200/100 LPD compete all as specified and as directed.
S&F in replacement of 3 KW Heating element used for solar water heating system any type,any model as per existing complete all as specified and as directed.
S&F bib taps cast copper alloy with crutch or butter fly handle, screwed town screwed for 15mm bore dia iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F Stop valve cast copper alloy scerwed down high pressure with crutch or butterfly handle screwed both end for 15mm bore dia iron pipe and for union for fixed as per sample/installed at site complete all as specified and as directed.
M&L for replacement of make up tank made out of MS Sheet 3.15mm thick fitted with ISI mark float valve brass assy with float brass rod 15 mm dia for solar water heater capacity 12 ltr all as per existing sample, shape complete all as specified and as directed.
M&L for replacement of toughed glass of collector of size 4mm thick and of size 6’x4’ as per existing arrangement complete all as specified and as directed.
M&L for replacement of rubber hose pipe 15mm dia between hot water tank & collector complete all as specified and as directed.
Supply & fixing in repair stainless steel storage tank including outer body cover complete set suitable for Solar water heater of capacity 100 ltrs complete all as specified and as directed.
All as per item Serial No 134.00 here-in-before but suitable for 300 ltrs solar water heater complete all as specified and as directed.
M&L for vacuum tube solar collector suitable for 100 ltrs solar water heater complete all as specified and as directed.
All as per item serial No 137.00 here-in-before but suitable for 200 to 300 ltrs solar water heater complete all as specified and as directed.
Supply and fix GI pipe medium grade 15 mm dia complete with fittings ISI marked fixed to wall/floor complete including taking down existing pipe lines complete all as specified and as directed.
Supply & laying of cladding of GI pipe 15 mm bore with aluminum sheet, wire mesh, Rock wool density 4.3 Kg/CM3 for hot water pipe from hot water tank to water tape or upto the end of system complete all as specified.(Note-Cladding will be done as per standard specification by MNRE approved manufacturer's person assuring quality complete all as specified and as directed.
M&L for C-PVC pipe 15 mm dia fixed on wall/ceiling, including all accessories for inlet & outlet water connection of solar water heaters complete all as specified and as directed.
S& F mild Steel framework of steel confirming to Fe 390 Gde Ee-165 as in brackets, cooler stands, solar water heater stands etc. including cutting welding etc complete and fixing at any height in existing masonry walls including scaffolding required complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide primer complete as specified and as directed.
Supply and Fix in replacement of water heater storage type electric capacity 3 ltr, complete all as specified and as directed. Make : Racold/Havells/Crompton/Bajaj
Supply and Fix in replacement of water heater storage type electric capacity 25 ltr, complete all as specified and as directed. Make : Racold/Havells/Crompton/Bajaj
Taking down of window/split AC 1.5/2.0 ton of any make opening complete.servicing of AC components carefully as cleaning with chemical solution and soft nylon brush and change of air filters,tightnining of loose screw,checking wiring connection and rectification complete assembling the same with body balancing and fixing in position and testing complete all as specified and as directed.
Testing leakage in system by injecting Nitrogen gas upto 300 PSI,rectification leaking spots/joints with gas welding work,filter anti moistoring agent,soldering,brazing,copper capillary tubing of reqd size and cleaning and flushing out complete system with gas making the system leak proof,vaccumising the complete system and supply and charging refrigerant gas as per existing type cooling appliances complete all as specified and as directed. Note : No extra cost shall be paid to the contractor for gas charging (any numbers of times) in case of leakage with in six months of initial gas charging except in case where external damage to the plant is noticed.
Split/window type AC of capacity 1.5/2.0 ton
Water Cooler of capacity 80/40
Refrigerator 165/195 ltrs
Supply and replace compressor sealed unit of the following appliances. New compressor will be of the same type (rotary/reciprocating)and make as per existing complete including replacement of copper tubing/capillary strainer etc, testing and commissioning complete all as specified and as directed.
Window type air conditioners of capacity 1.5 /2.0 Ton.
Split type AC of capacity 1.5/2.0 Ton
Supply and replace running/starting capacitors of the following capacities for ACs complete all as specified and as directed. Make : Siemens, epcos
Supply and replace overload protector relay of AC of capacity 1.5/2.0 Ton of existing make/model at site complete all as specified and as directed.
Supply and replacement of voltage stabilizer 5 KVA 230v complete all as specified and as directed. Make : V-Guard/AE/Microfex/Godrej
Supply and replacement of remote control with PC board suitable for 1.5 Ton capacity split type air conditioner suitable for existing make & model complete all as specified and as directed.
Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/overhauling/lubricating greasing/removal and replace of burn out bearing bush shaft /painting complete after scrapping old painting and re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 Sqmm complete all as specified and as directed.
Supply and replacement of undermention items against item serial No 153.00 here-in-before as follows:-
Wood wool pad.
Cooler fan motor.
Fan blades.
3 pin plug top one way 5 Amp, 230V.
Water lifting pump 230V single phase
S&F MCB SPN 40 Amps,' C' series, bracking capacity 10KA, 240V complete all as specified and as directed.
M&L for submain wiring with Two runs of single core 6 sqmm for main wire and one run of single core 6 sqmm as earth wire of stranded copper conductor FRLS PVC insulated unsheathed cables conforming to IS : 694 drawn through and including concealed in wall rigid medium duty unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and accessorie all conforming to IS specification complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for laying reinforced precast concrete cable cable cover class LV type 1, flat size 250mmx150mmx40mm complete all as specified and as directed.
Material and labor for point wiring with 2.5 sq mm PVC insulated unsheathed single core multi-stranded copper conductor cable 1100 Volts grade, drawn through and including 20 mm dia rigid non-metallic PVC concealed conduit (medium grade) along with 2.5 sq mm continuous PVC insulated unsheathed solid/stranded copper conductor cable for earth continuity wire, connected to earth dolly and to be terminated in metal boxes readily available and suitable for 15 Amp socket concealed type including testing on completion complete all as specified and as directed for power point controlled by one 15 Amp switch.
M&L for complete servicing & testing of reverse Osmosis plant of output capacity 100 ltr per hour (RO,UV,UF) 230 volt AC, 7 stages purification, TDS upto 2000 PPM, rejection of TDS 90% including filter feed pump 0.5 HP, dual media filter 3.5 kg/cm2, RO membrane-03 Nos, anti scalant dosing system 4 kg/cm2, micron filter set post carbon post corbon, reverse osmosis module, ultra violet set high pressure pump, minimum duty cycle 1200/ltr/day complete all as specified and as directed.
M&L for repair/maint of Solar Tree PV generation plant of 10 KW capacity without battery 3 phase 415 volt AC output, Grid tied with solar photo voltalic modules with minimum 325 WP rating poly crystaline silcon PV modules, open circuit voltage (Voc) 46 V, short circuit current (Ics) 8.6 Amp Optimum operating voltage (Vmp) 36.5V & optimum operating current (Imp) 8.2 Amps including control devices complete all as specified and as directed.
shyam construction
RUHI ASSOCIATES
V K Constructive Builders
M/S A.K. ENGINEERS
M/s DEVI DAYAL CONSTRUCTION CO
PARADISE INFRA POWER COMPANY
SABHYATA ELECTRICAL AND MECHANICAL
ISHWAR ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .