Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹38.1 L+₹75,143.41 (2.01%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹40.0 L+₹2.6 L (7.05%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹41.1 L+₹3.7 L (10.0%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹41.7 L+₹4.4 L (11.8%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
8 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of storage shade for Lubs and Grease in 58 Coy ASC (Sup) Special Repair to Bldg No P-15 and Latrine Bathroom of Riding School in the area of AGE B/R II under GE (N) Ahmednagar
2023_MES_575039_1
8705 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer North Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer(North) Ahmednagar
₹94,000
Yes
2 Mar 2023
14 Jan 2023
10 Feb 2023
14 Jan 2023
8 Feb 2023
27 Jan 2023
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation soft /loose soil and getting out etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl No 01 but hard / dense soil.
Excavation in trenches exc 1.5 m and n.exc 3.0m deep and getting out in hard/ dense soil etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D2 (using 40mm graded aggregate) as in foundation /mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design Mix in founditions, including rafts, footings, foundition beams, pinth beams, bases for columns etc basement salbs, undeer -ramed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundition, footings, bases of colmns, raft and raft beams, sides and soffits ( if any) of foundition and plinth beams, and similar work, vertical or to batter etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design Mix in columns, pillars, peiers, posts and struts etc complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc complete all as specified and directed by Engineer-in-Charge.
Formwork fair finished to soffits of suspended slabs such as roof slabs, roof slabs,landings and similar work not exceeding 200mm thick (Horizontal or sloping) etc complete all as specified and directed by Engineer-in-Charge.
Formwork to edges of concrete fats, treads, breaks in floors, window cills concrete railings, opening in concrete wall floor and roofs nexc 20cm wide and sides of RCC/PCC bends in walls horizontal or sloping and similar work exc 10cm and n.exc 20cm wide for fair finished surfaces etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design Mix in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies,deck slabs and in shelves and the like etc complete all as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam hunchings, griders, bressummers, lintels, cantilevers, shelves including support, overhangs, etc, also splays between and beams etc complete all as specified and directed by Engineer-in-Charge.
Forwork to chullah hoods, chajjas, troughs and similar items including edges etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design Mix in beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design Mix in Chajjas etc complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending sprially for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9mm dia or securing with clips
All as per item No 16 above but 6 to 8mm dia TMT bars
All as per item No 16 but TMT bars 5mm dia and over upto and incl 10mm dia in stirups, spacers and binder
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in 1:6 etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering, 10 mm thick on faces of brick work / concrete work or stone masonry surfaces with Ready Mix Plaster (RMP) in single layer of Makes / Brands ACC's "Accoplast" / CK Birla's "Aerocen" / Magic Plast / Buildwell / Speed Dry Mix's "Eco Plaster" etc complete all as per manufacturer's instruction and directed by Engineer-in-Charge. The thickness of plaster is the minimum thickness and is exclusive of thickness of key. Dubbing if required is deemed to be included in the plaster and nothing extra shall be paid.
Material and labour for rendering, 12 mm thick on brick work / concrete work or stone masonry surfaces with Ready Mix Plaster (RMP) in single layer of Makes / Brands ACC's "Accoplast" / CK Birla's "Aerocen" / Magic Plast / Buildwell / Speed Dry Mix's "Eco Plaster" etc complete all as per manufacturer's instruction and directed by Engineer-in-Charge. The thickness of plaster is the minimum thickness and is exclusive of thickness of key. Dubbing if required is deemed to be included in the plaster and nothing extra shall be paid.
Material and labour for providing water proofing treatment on roofs as per latest zonal specification , as per manufecturer's instructions and as specified after taking down/out as existing at site :- (a) Cleaning the newly plastered surfaces with wire brushes and applying a coat of bituminous primer @ 0.25 ltrs/sqmts and allow to dry. (b) Applying and laying torch APP polymer modified bituminous membrance 3 mm thick with non woven polyster matt as reinforced weighing not less than 3 kg/sqmts with white gravel/mineral finished by thermofusion process including applying one coat of aluminium paint.
M&L rendering 10mm in CM 1:3 using 100% course sand on roof mixed with and including WPC @ 3% by weight of cement and finished the surface even and smooth without using extra cement. Note :- Water proofing compound measered and paid separately
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface of wall and appling two coat of oil bound distemper over a coat of chalk whitening etc complete all as specified and directed by Engineer-in-Charge.
M&L preparation of plastered surface and applying 3 coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered of wall applying two coats cement base paint over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix steel windows with side hung double shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as directed.NOTES: 1) Guard bars shall be measured and paid separately as supply only. 2) M & L for galzing shall be measured and paid separately.
Supply only MS guard bars 10 mm welded to steel window / ventilators etc complete all as specified and directed by Engineer-in-Charge.
M&l for preparing new steel surfaces of any description appling two coats of synthetic enamel paint over a coat of red oxide primer over any description exc 10 cm width or girth etc complete all as specified and directed by Engineer-in-Charge.
S&F 3 mm thick ordinary quality plain steel glass glazing with oil putty in squre not exceeding 0.5 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge.
M&L moorum filling in floors or paving laid in layers n.exc. 15cm thick spread levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of guage exc 63mm but n.exc 100, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rooled/rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC type 1:3:6 (40mm greaded aggregate) as in plinth protection etc complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm graded aggregate) in sub base etc complete all as specified and directed by Engineer-in-Charge.
M&L for hand cut Kota stone slab flooring 20-25mm thick laid over including 15 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut Kota stone slab 20-25mm thick in rider of steps, skirting, dado and pillar laid over cement screed base laid over including 10 mm thick screed bed in CM 1:4 and jointed with grey cement slurry mixed with grey cement slurry mixed with pigment to match the shade of the slab including mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling including spreading levelling, watering and well ramming in layers n.exc 25cm in soft/loose etc complete all as specified and directed by Engineer-in-Charge.
Removing excavated (soil) material n.exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete work in pavement / hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less etc complete all as specified and directed by Engineer-in-Charge.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete GDE Fe410-0 or Fe 310-Of etc complete all as specified and directed by Engineer-in-Charge.
M&L for Letter or Figures (block, roman, Italic or Indian) of stainless steel of size 300mm high, 50mm wide and 25mm thick of 3mm thick sheet plate (58 COY ASC (SUP) TYPE 'B') including welding, grinding, buffing, polishing and making curverature ( where ever required) and the same with necessary stainless steel nuts and bolts etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick/stone walls or ceiling including taking out joints hacking for keys, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 15 mm thick on stone/brick / concrete surfaces in cement mortar 1:4 surfaces finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 15 mm thick on stone/brick / concrete surfaces in cement mortar 1:6 surfaces finished even and fair with sagol finish etc complete all as specified and directed by Engineer-in-Charge.
Preparing New surfaces and applying two coats of oil bound distemper on wall including smooth roller finish complete all as directed.over a coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of newly plastered surfaces on walls and applying two coas of cement base paint over a coat of primer on walls etc complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness size,quality or description) from wooden/Steel frames or stone, concrete or brick surrounds glazed with putty or fixed with beads n'exc 0.5 Sqm in each pane etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each paneetc complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slab & tiles of any description in floor, approx laid, bedded & pointed in any mortar etc complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete(un-reinforced) in ground floor & paving n.exc 15 cm thick below or above ground level etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:4:8 type D-2 using 40mm graded aggregate as in sub base of floor 75mm thick etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut Kota stone slab 20 to 25mm thick (minimum size 30cm x 45cm) as in flooring, laid over and incl cement screed bed 15mm thick in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and granite polishing etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rough dressed shahabad stone, 25 mm to 40 mm thick laid over and including 15 mm thick screed bed in cement mortar 1:6, laid and jointed pointed in cement mortar 1:3 etc complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in 1:6 etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old steel surfaces and applying a coat of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
Material and labour for applying one coat of synthetic enamel paint on old wooden surfaces of any description exc 10 cm width or girth including preparation of surfaces and smooth finish with roller etc complete all as specified and directed by Engineer-in-Charge
Preparation of old plastered surfaces and applying one coat cement base paint on walls etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing Old/New plastered surfaces and applying one coats of oil bound distemper on wall including smooth roller finish etc complete all as specified and directed by Engineer-in-Charge
Material and labour in repairs for false ceiling with Vinyle faced Arm-Gyp-FB, ceiling 600 x 600 x 10mm thick with washable metallized polyster foil backing with Vinyle covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wire fixed to roof at 600mm centre to centre as per manufacturere's instructions / specification and etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including ridge etc complete all as specified and directed by Engineer-in-Charge
Supply and fix pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge
S & F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads etc complete all as specified and directed by Engineer-in-Charge
Material and labour for Non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in set and jointed in neat cement slurry laid over and incl. screedbed 15mm thick in CM 1:6 set and jointed with white or coloured cement to match complete joint free
Material and labour for Glazed ceramic coloured tiles in vertical surface 350 x 250 x 7 mm /450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. over and including 10 mm thick backing coat in cement
Supply and fixing in repairs PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring fixed to wall/laid in trenches or in floors with approved solvent/adhesive including neceassry stack clamps etc complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each
Supply and fix solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, all as directed.
Supply and fixing Factory Made Solid PVC Moulded Door Shutter, with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face
Supply and fix aluminium anodised barrel tower bolt of extruded section 200mm long.
Supply and fix aluminium anodised handles of extruded section 150mm long.
Supply and fix repairs PVC valveless, syphonic action type, flushing cistern,low level, all accesories all as directed. Make :- Sleek essence series Of Hindware or Cat part No E8303 Of Parryware .
Supply and fix mild steel butt hinges medium weight cold rolled of size 100mm
Supply and fix wash hand basin vitreous China of size 550 X 400 mm including a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap all as directed.
M&L for Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe)
Supply and fix bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as directed.Make:- Cat part No MOR 1020 A(Orintal series) of MARC or equivalent in PLUMBER, ESS-ESS
Supply and fixing stop valve cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore
Supply and fix 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as directed.
Taking up or down steel tubing 15 mm bore of pipes and connections etc complete all as specified and directed by Engineer-in-Charge
Taking up or down steel tubing 20 mm bore of pipes and connections etc complete all as specified and directed by Engineer-in-Charge
S&L of CPVC pipes SDR 11 including fittings in trenches, 16mm outer dia fixed to walls /ceiling or laid in trenches incl all necessary fittings etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 83 but 20mm outer dia etc
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 12 module suitble for Mylinc series of Legrand including white plates with frame upto 12 module of make suitable for Mylinc Series ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One bell point controlled by one switch 5 Amp single pole, one way on independent board
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
All as per Item No 2 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination two in one, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
S&F bell Multi music type elelctric 230V AC single pole etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Socket Outlet 6 Amp, 2/3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Bell push, 6 Amp, one module etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Fan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs,, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Industrial type Aluminium housing ultra slim square profile LED lighting fixture, environmental friendly, energy efficient ready to use pack Industrial type LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge
Supply & fix 42 Watt LED Panel 2X2 environmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for armstrong/Grid ceiling, complete with separate electronic driver ceiling light 42 Watt with and including connecting up with & including twin core, twisted, flexible copper conductor cable of suitable size 230 Volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge
Supply & fix in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :-
(a) LT cable10 Sqmm, 2 core.
Supply &lay HDPE pipe 40 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge.
Taking out/down and opening of existing ceiling fans 1200 mm sweep,from any position, of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material /items , making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed.
Material and labour for preperation of ceiling fans 1200 mm sweep, of any make by cleaning of metal surfaces including painting with spray painting on required gloss with white synthetic enamel paint on complete body of fans and writing MES No with black synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
An amount of Rs 15,116.50 shall be deducted from BOQ on account of schedule of credit
M/s. A P INFRA
M/s. N D Karande
M/s AG PATHAN
Arihant Construction
DAKSH ENGINEERS AND BUILDERS
Ms. M.D. Auty
MS. G.A. CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .