| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC | L1 | Accepted-AOC Awarded Contract | |
| 2 | L2₹6.9 L+₹6,684.61 (0.98%)Rejected-Finance NO 3D MANDHAVEIL KALLAKURICHI TALUK DISTRICT 606 202 | KALLAKURICHI | TAMIL NADU | 606202 | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹7.0 L+₹13,257.57 (1.94%)Rejected-Finance | L3 | Rejected-Finance Third Lowest |
Tender Value
Refer Docs
EMD Value
₹6,770
Closing Date
14 Sept 2023, 3:00 pmClosed
The Executive Engineer
The Executive Engineer,PWD Buildings (Construction and Maintenance ) Division, Kallakurichi 606 202
Construction of Toilet block in GHSS at Irunthai in Kallakurichi District
2023_PWD_364539_1
6/23-24-2/JDO/Dt.28.08.2023
Open Tender
Civil Works - Buildings
Lump-sum
60 days
Irunthai in Kallakurichi District
Please refer Tender Document
8 documents required · 8 mandatory
₹0
₹6,770
5 Dec 2023
1 Sept 2023
14 Sept 2023
2 Sept 2023
14 Sept 2023
2 Sept 2023
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling M-Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling of well gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete complying with standard specifications and as directed by the Departmental Officers.
Cement Concrete 1:5:10 (One Cement, Five M.sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc., complete complying with standard specification.
Brick work in Cement Mortar 1:5 (One Cement and Six M Sand) using best quality II class ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" including neat finishing, curing, etc., complete complying with standard specifiction.
For Foundation and Basement.
For Superstructure in Ground Floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For Floor Slab, roof slab, rectangular beam Ell beam, lintels bed block, landing waist slab, canopy slab etc.,
For plane surfaces such as rectangular or square RCC coloumns, sunshades, top and bottom slab of RCC boxing etc.,
Providing and laying inposition, Standardised Concrete Mix M 20 Grade in accodance with IS 456-2000 using M SAND and 20mm down graded hard broken stone jelly for all RCC items of work with minimum cement content of 325 kg/m3 and minimum water cement ratio of 0.55 including admixture(plasticiser/super plasticiser)in recommended propertions as pe IS:9103 to accelerate, retard setting of concrete workability without imparing strength and durability with about (5 cu.m) 7730kg of 20mm stone jelly and with about (3.33cu.m) 5156 kg of 10-12 mm machine crushed stone jelly and with about (4.70 cu.m)7670 kg of M sand but excluding cost of reinforcement grill and fabricating charges etc, Complete.
For Foundation and Basement.
For Superstructure in Ground Floor.
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two M sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.
Reinforced cement concrete precast slab 50mm thick using 20mm Jelly.
Reinforced cement concrete precast slab 75 mm thick using 20mm Jelly.
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Brick partition walls of 11.50cm thickness using best quality II class ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three M.Sand) using hoop iron reinforcement if found necessary including curing etc.,
Superstructure in Ground Floor 11.50 cm thick.
Manufacturing, supplying and fixing in positon of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification.
Cement Concrete 1:5:10 (One Cement, Five M.sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc., complete complying with standard specification.
Flooring with jointfree rectified ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.
Providing granolithic floor finish of 40mm thickness with plain cement concrete 1:2:4 (One Cement, Two M.sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers).
Plastering with Cement Mortar 1:5 (One cement and Five M.sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification.
Manufacturing, supplying and fixing of Steel doors with following specification. MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 G CR Sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter. 300mm length of hinges 2 Nos, for shtter is provided. 6 Nos. of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. at the top provided. 250x16mm size of Two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear sideof the door at an appropriate place and 1 No. of M.S. handle of heavy duty. Single Leaf.
Solid PVC Door Shutters using 19 guage 19mm MS square tubes for styles and outer fames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for paneling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mmx30mm. The over all size of top rail, lock rail and bottom rail shall be 75mmx30mm. The over all size of frames shall be 50mmx45mm with suitable rabate for housing the shutter. (Solid panel PVC door with frame)
Supplying fixing and errecting of steel roof trusses and roof truss purlins fixing for G.I. sheet roofing using MS. L. angle of size 50x50x6 mm raffter, Tie angles and MS angle of size 50x50x6mm for sturts and MS plat of size 12 mm thick for fixing G.I. sheet. The purlins using MS L. angle of size 50x50x6 mm shall be properly anchored to the supporting super structure and fixed in concrete at wall and spacing of purlins are to be arranged to use the standard size or sheet and spacing should not execeed 1680 mm and free over hang at eves should not be more than 400 mm, the cleats shall be wellded to the trusses firmly and fixed on the down stream side of purlins. The ridge purlins fixed at 77 to 115 mm away the apex of the roof. The trusses shall have welded joints only at all guessets plate junctions except gussets at bottom chords to have bolts and nuts to permit transportation of trusses as directed. The foundation anchor bolts of trusses will be fixed in concrete at wall in bed blocks and well cured, labour for erection of trusses of approved quality transportation, priming coat for all members, cutting, bending, and welding etc., The trusses should be connected at bottom 1 / 3 part by steel tie angles and with top and bottom wind bracings as per design given. The chord of the trusses of bottom channel should suitablely cambered. The truss and purlins should be given priming coat of Rex Oxide primer of approved quality including labour for erection, transportation, wellding etc., complete complying with standard specification.
Supplying and fixing by drilling holes and not by puching for Roofing with pre painted Galvalum sheet of 0.47mm thick of best approved quality with required size with curved shape and white ridge sheet with necessary bolts and nuts bitumen washers, including cutting the sheet to the required size found necessary during execution etc., Complete complying with standard specifications. [The sheet should be got approved by the Engineer incharge before use on works]
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 30 L grage stainless steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick stainless steel circular base plate of 304 grade.
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. (Above Ground Level - Internal Water supply)
25mm dia UPVC Pipe.
20mm dia UPVC Pipe.
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
110mm dia PVC Soil Waste Pipe
75mm dia PVC Soil Waste Pipe
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing in position best approved quality PVC Nahini trap of 100 mm x 75 mm size with PVC grating of approved quality fixed over a bed of brick jelly lime concrete.1:2:5 (one lime two M sand and five brick jelly) using 40mm broken brick jelly including dismantling the flooring concrete / Brick masonry wherever necessary and redoing the disturbed portion to the original condition and giving connection to the PVC soil (stacks) pipe as directed etc., complete complying with standard specifications. (The Nahini Trap should be got approved by Executive Engineer before use on works)
Supplying and fixing in position Indian make white glazed earthenware squating type urinal of best quality and approved make including dismantling masonry, if necessary and re-doing the same to original condition, etc., complete complying with standard specification. (The squatting urinal should be got approved by the Executive Engineer before use on works).
R.Jagadesh
Thiru.R.Suresh
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .