Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC GOVT CONTRACTOR VILL NAYA SUJAN FEROZPUR KALAN TEH DIST PATHANKOT PIN 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | ₹3.7 L Quoted ₹4.1 L | L1 | Accepted-AOC LOWSET |
| 2 | L2₹5.0 L+₹88,257.70 (21.3%)Rejected-AOC | ₹5.0 L+₹88,257.70 (21.3%) | L2 | Rejected-AOC OTHER THAN LOWEST |
| 3 | L3₹5.2 L+₹1.0 L (24.3%)Rejected-AOC | ₹5.2 L+₹1.0 L (24.3%) | L3 | Rejected-AOC OTHER THAN LOWEST |
| 4 | L4₹6.4 L+₹2.2 L (53.8%)Rejected-AOC | ₹6.4 L+₹2.2 L (53.8%) | L4 | Rejected-AOC OTHER THAN LOWEST |
| 5 | L5₹6.5 L+₹2.3 L (56.5%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹6.5 L+₹2.3 L (56.5%) | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
31 Dec 2021, 6:00 pmClosed
GE Basoli
GE Basoli PO Lakhanpur Distt Kathua JK
REPAIR AND MAINTENANCE OF LT OH LINE LT UG CABLE AB CABLE LT PANELS LT SWITCH GEARS AT JANGLOT MIL STATION GRN UNDER GE BASOLI.
2021_MES_489781_1
GE/BAS-43/2021-22
Open Tender
Civil Works
Item Rate
180 days
Area of Janglot under GE Basoli
class D catg b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Basoli
₹60,000
Yes
30 Mar 2022
23 Nov 2021
3 Jan 2022
24 Nov 2021
31 Dec 2021
18 Dec 2021
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole and lying of UG cable and getting out in any type of soil complete all as specified and directed.
Excavation in trenches n. exc 1.5 mtr wide and but exc 1.5mtr in depth for foundation of pole and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, and including spreading, leveling, watering and well ramming in layers not exceeding 25cm completed all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point complete all as directed.
M&L Sub Class 'B' brick covering protection to the electric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified.
Supply & filling sand cushioning to underground cable 8 cm before laying the electric cable and 15 cm after laying the cable complete all as specified considering as per SSR 2009 of part -I
M&L for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface, complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate for foundation of poles and stay assembly, complete all as specified and as directed.
Supply and erect steel tubular swaged pole type 410 SP-31 (9 meter long) complete with cast iron / MS base plate, top plate welded with MS round sheet with necessary nuts, bolts and washers duly painted with a coat of red oxide primer and two coat of aluminum paint including black and yellow strip 30cm in height above the coping of the pole all as specified and as directed. Make: - M/S ELECTRO STEEL/SURJEET STEEL INDUSTRIES/NATIONAL TUBING CO KANPUR.
Supply and fixing in replacement aluminum conductor steel re-inforced (ACSR) Ferret/of size 6/1x3.00 mm /of size 6/1x2.59 mm (weasal) and 6/1x2.11 mm for LT lines on concrete poles, stretching without kinks and bends, binding with (rates inclusive) binding wire complete all as specified and as directed. Make : Alind/Industrial cable(India) ltd/NICCO/Bharat conductor
Restretching of existing loose OH,LT ACSR conductor wire including GI wire along the span of poles for sagging within the permissible limit,(five/four/two wireline), including binding/rebinding/joining with Aluminium winding wire in case of breakage of conductor, size of winding wire shall not be less than 2 sqmm complete all as specified and directed. Note : (i) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during the stretching. (ii) Irrespective Nos of wire between poles, the distance between poles shall be consider in RM for payment of this item. No claim on this account shall be admissible.
Trimming /cutting tree branches with clearing space up to 2 meter from the over head conductor system all around for LT distribution system, and as directed. Note : contractor shall take electric shutdown before start work from main station and start line after trimming of tree and informed to the EIC.
S&F in structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including, nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat, one finishing coat of aluminum paint and epoxy coating, including taking down old corroded structural steel all as directed.
S & F in shackle type, vitreous Insulator including one galvanized mild steel spindle, two galvanized iron washers, and one galvanized iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt, and as directed. Make- Jaipuria/RASHTRIYA/ PACTAL
S&F stay assembly complete comprising of 20mm dia 40cm long stay bow rod 20mm dia x 1.8 Mtr long galvanized stay rod threaded with nuts, including 300mmx300mmx6mm thick plate necessary clamps etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 complete including taking down U/S stay assembly. (Note: Loop type insulator, stay clamp, stay wire, excavation and concrete work measured separately).
S&F galvanized steel stranded stay wire size 7/4mm for stay assembly, complete all as specified and as directed.
S&F loop type insulator with complete fitting porcelain, vitreous white or brown large size with over all dimensions 90x140mm, clearance of hole 25.5mm, complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip or strip to earth plate are fixed with welded joints.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009.
M&L for painting of MS cross arms as existing site made out of angle iron /MS channel and clamp in position fixed to PCC/steel pole 9 meter long with 2 coat of aluminum paint over a coat of red oxide as primer after scraping existing painted surface, complete all as specified and as directed.
M & L for Painting with two coats of synthetic enamel paint up to 1.5 meter above the ground level with black and yellow colour alternatively 30 cm interval from bottom of pole of 9 meter RCC/tubular Poles
M & L for Painting of steel pole 9 meter long in position with 2 coat of aluminum paint over a coat of red oxide primer after scraping the existing painted surface complete all as specified and as directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE185 sqmm 3.5 core, PVC insulated, armored heavy duty electric cable with aluminum conductor,1100 Volts grade, cross section area are as under of Make- polycab/KEI/RPG including disconnecting and taking out old unserviceable LT cable. Note: (I) Earth work/ sand cushioning shall be measured and paid separately.
All as per item above but 150 Sq mm X 3.5 core, complete all as specified and as directed.
All as per item above but120 Sq mm X 3.5 core, complete all as specified and as directed.
All as per item above but70 Sq mm X 3.5 core, complete all as specified and as directed.
All as per item above but16 Sq mm X 4 core, complete all as specified and as directed.
All as per item above but25 Sq mm X 3.5 core, complete all as specified and as directed.
All as per item above but16 Sq mm X 2 core, complete all as specified and as directed.
Taking out the old unserviceable cable for repair in trenches or passing through pipe/fixed to pole/ wall XLPE insualted300/240/ 185 Sqmm X 3.5 core armored heavy duty electric cable and depositing in the MES store yard
All as per item above but120/95 Sqmm X 3.5 core, complete all as specified and as directed.
All as per item above but 70/50/35 Sqmm X 3.5 core, complete all as specified and as directed.
All as per item above but25/16/10 Sqmm X 3.5/4/2 core, complete all as specified and as directed.
S & F in repairs cable end joint kit for 1100 volt, outdoor type joint complete with all jointing material and accessories suitable for 3.5 core cable of size 50 sqmm to 185 sq mm complete all as specified and as directed.
S&F DWC high density polyethylene pipes in replacement having 63/50mm outer and inner dia as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable complete all as specified and directed. Make -Trupati /Equivalent
S&F DWC high density polyethylene pipes in replacement having outer and inner dia 90/76 mm, as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable complete all as specified and directed.
S&F DWC high density polyethylene pipes in replacement having outer and inner dia 120/103 mm, as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable complete all as specified and directed.
Repair/ replacement to the unserviceable rusted bus bar panel including fabrication of front opening and outdoor type incorporated with busbar chamber ground mounted having aluminum bus bar capacity 200 amps insulated with RYB& black PVC insulation suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.00 mm thick also having provision for incoming/outgoing MCCB,s/ cables, 02 Nos earth terminal point complete with 10mm bolt, 02 nos nut and 02 Nos Washers3mm thick complete earth . The panel body must be powder coated by the complete tanks dip process and to remove all impurities from the panel sheet, all the door must be fixed with detach able pin type hinges, steel door locking system, all the electrical connection inside the panel from bus bar to MCCB,s shall be through aluminum strip properly insulated fixed on SMC/DMC insulators. having arrangement for fixing the same on ground with MCCB 100 Amp 25 KA rating 4 Pole 415 volts - 01 No (Incoming) all as specified and directed. Panel body shall be fixed on iron angle frame of size 50x50x5mm 30 cm grouted in 1:2:4 type B1 PCC 20 mm graded and 30 cm above the ground level duly painted with two coat of synthetic enameled black paint over a coat of red oxide primer all as specified and directed
Repair/ replacement to the unserviceable rusted bus bar panel including fabrication of front opening and outdoor type incorporated with bus bar chamber ground mounted having aluminum bus bar capacity 100 amps insulated with RYB& black PVC insulation suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.00 mm thick also having provision for incoming/outgoing MCCB,s/ cables, 02 Nos earth terminal point complete with 10mm bolt, 02 nos nut and 02 Nos Washers,3mm thick complete earth . The panel body must be powder coated by tanks dip process of power coating. To remove all impurities from the panel sheet, all the door must be fixed with detach able pin type hinges, steel door locking system, all the electrical connection inside the panel from bus bar to MCCB,s shall be through aluminum strip properly insulated fixed on SMC/DMC insulators. having arrangement for fixing the same on ground with MCCB 63 Amp 25 KA rating 4 Pole 415 volts - 01 No (Incoming) all as specified and directed. Panel body shall be fixed on iron angle frame of size 50x50x5mm 30 cm grouted in 1:2:4 type B1, PCC 20 mm graded and 30 cm above the ground level duly painted with two coat of synthetic enameled black paint over a coat of red oxide primer all as specified and directed
S&F in replacement on load change over switch in sheet steel enclosure with front handle of capacity 100 Amps, four poles, 415 Volts complete all as specified and as directed.
Dismantling and Taking down old unserviceable PCC LT pole of any size including earth work , removing the PCC etc complete all as specified & directed
Dismantling and taking down old existing ACSR conductor any type from existing HT/LT pole all as specified and directed.
Dismantling of steel work (brackets, clamps, channels including disc and pin insulators, nut & bolts) from existing HT pole complete all as specified and as directed.
Dismantling insulators any type, any size and depositing to the same to the MES store yard, complete all as specified and as directed.
Dismantling of earth wire/ stay wire, complete all as specified and as directed.
Relaying of existing serviceable old bricks retrieved during excavation of old existing LT cable, providing protection of the electric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified
Taking out existing old bricks from the trenches in respective item of taking out of old unserviceable cable and staging for reuse in the same work where required all as specified and directed.
M&L for galvanized steel wire 4 mm dia complete all as specified and as directed.
S&F in replacement of Galvanized strip of size 32x6 mm beyond 7.5 mtr beyond to earthing lead other places complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .