Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.2 L+₹2.1 L (5.37%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹41.2 L+₹2.1 L (5.44%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹51.3 L+₹12.1 L (31.0%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
1 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
RAHUL MEENA IDSE EE
GE KASAULI , DISTRICT - SOLAN HP
PERIODICAL SERVICES TO BUILDINGS AND WELCOME MAINTENACNE (B/R E/M) TO OFFICERS MD ACCN AT DAGSHAI UNDER GE KASAULI
2022_MES_522076_1
GEK-11/2022-23
Open Tender
Civil Works
Item Rate
330 days
DAGSHAI UNDER GE KASAULI
Pls refer tender documents .
7 documents required · 7 mandatory
₹500
GE KASAULI
₹1 L
Yes
24 Jun 2022
5 May 2022
8 Jun 2022
5 May 2022
1 Jun 2022
19 May 2022
60 days
Amount
Schedule 'A' Section - I
M & L for taking down cement or lime plaster of any description on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Demolition of reinforced cement concrete in not exceeding 15cm thickness (below or above ground level) slabs beams etc...and disposing off the rubbish materials where complete all as specified and directed
Dismantling wall as ceiling board (fibre, pulp, insulation, etc) or insulation boards/slabs/kitchen cup board, any thickness, including cover fillets complete all as specified and directed.
Taking down chowkats or frames n.exc. 1.5 Sqm each but without taking off shutters from the frames complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 sqm each but without taking off shutters from the frames complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding removing serviceable tiles to store and rubbish off the premises, complete all as specified.
Demolition stone slabs or tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified.
M&L for mild steel TMT bars 6 to 8 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified
M&L for Precast RCC 1:2:4, type B-1 (using 20 mm graded stone agg) in slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
M & L for Rendering 15mm thick in cement plaster 1:4 on other than fair faces of stone or brick surfaces incl finishing surface with out using extra cement complete all as specified and directed
M & L for Rendering 15mm thick in cement plaster 1:6 on fair faces of brick or stone surfaces or concrete surfaces/stone work incl finishing surface w/o using extra cement complete all as specified and directed
M&L for rendering 10mm thick in cement mortar 1:3 on ceiling brick/concrete surfaces w/o using extra cement all as specified and directed
M&L preparation of new plastered surfaces of walls and applying two coat of exterior emulsion paint over a coat of primer of approved tint and make complete all as specified and directed
Preparation of new surfaces applying two coats of oil bound distemper over one coat of chalk whiting on walls all as specified and directed
Taking up or down waste and vent pipes of any type and any dia complete.
M&L for preparation of new plastered surfaces of wall including cornices, pillasters etc of bldgs and applying three coat of white wash complete all as specified and directed
Preparing newly plastered surfaces of ceiling l & applying three coats of white wash, complete all as specified & directed.
M & L for Renewing tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds in cement mortar and laying or setting, jointing and pointing new or old tiles complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20mm thick CM 1:6 for laying tiles and stone slab complete all as specified and directed
M & L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment all as specified.
M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge
Material and labour for Glazed ceramic coloured tiles in vertical surfaces exc 0.08sqm and n exc 0.16sqm, 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match with and including 10mm thick backing coat on vertical surfaces of wall in cement mortar 1:4 complete all as specified and as directed.
M&L for 16 to 18 mm thick granite stone machine cut (table rubbed & polished) in one piece as in steps,jambs,pillars,windows cills,cooking platform and similar work bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including grinding and polishing including making hole in platform complete all as specified.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, including making hole by drilling for gas pipe and other similar situations all as specified and directed
Demolition of brick work or stone masonary built in cement mortar including quions, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and disposing off the rubbish materials where complete all as specified and directed.
M&L for brick work with sub class `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed
S&F in repair for 15 mm dia bib tap standard of PTMT any colour high pressure screwed foriron pipe and fixed (Minimum weight 15mm-90gms/20mm 125gms).
S&F in repair for 15 mm ball valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or ferrule and fixed, complete all as specified..
S&F in repair 15mm bore angle cock, chromium plated, brass, fancy type, screwed both ends for iron pipe or for union etc complete all as specified and directed.
S&F in repair 15mm bore PVC connection with brass nut of length 450mm etc complete all as specified and as directed.
S&F in repair 15mm bore Bib taps, chromium plated cast copper alloy, fency type with crutch or butter fly handle, screwed down for iron pipe or for brass ferrule etc complete all as specified and directed.
Ditto as item No 32.00 above but long body complete all as specified and directed.
S&F in repairs PVC waste down pipe 32 mm bore etc complete all as specified and directed.
S&F in repairs 32mm chromium plate coupling for WHB complete all as specified and directed.
S&F in repairs 40mm chromium plated waste coupling for kithen sink complete all as specified and directed.
S & F in repair for 15mm bore pillar tap fancy type, cast copper alloy chromium plated screwed down, high pressure with crutch or butter fly handle etc complete all as specified and directed.
S&F in repair 15 mm bore brass Chromium plated wall/basin/sink mixer for mixing hot & cold water screwed down for iron pipe etc complete all as specified.
S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
S&F in repair CP toilet paper holder all as specified and as directed.
S&F in repair chromium plated shower rose with or without swivel joints and size including fixing to steel pipe or unions mixing valve including three joints to steel pipes or union and plugging and screwing to walls complete all as specified and directed.
S&F in repair Towel rail 600mm long chromium plated fixed in and including chromium plated brass screws and wooden/plastic cleats etc complete all as specified.
S&F as in repair fixing WC Orissa pattern of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) includung provision of lime concrete bedding etc complete all as specified and directed by Engr-in-Charge
S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets 10 Ltrs capacity complete all as specified complete all as specified and directed by Engr-in-Charge
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts,) complete incl making good to floor to match with adjoining surfaces all as directed by Engr-in-Charge
S&F EWC seat cover, in white colour, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, in repairs complete all as specified and directed by Engr-in-Charge
Taking up or down 20 mm dia of steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store upto 15 mm bore all as specified and directed by Engineer-in-charge.
M & L for 15mm bore `Medium grade` GI tubing with all fitting and to walls and ceilings or laid in floors as in repair complete all as specified and as directed by the Engineer-in-Charge
M & L for 20mm bore `Medium grade` GI tubing with all fitting and to walls and ceilings or laid in floors as in repair complete all as specified and as directed by the Engineer-in-Charge
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceble PVC water tank all as specified in SSR Part-I completed and as directed by the Engr-in-Charge
M & L for 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceble PVC water tank all as specified in SSR Part-I completed and as directed by the Engr-in-Charge
S & F in repair CP soap dish fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC bath cabinate with mirror ,complete all as specified.
S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to laid in trenches or in floors/wall complete all as specified and as directed by the Engineer-in-Charge
S & F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/wall complete all as specified and as directed by the Engineer-in-Charge
S&F PVC(SWR) bend 110mm dia bore complete all as specified and directed by Engr-in-Charge
S&F PVC(SWR) bend 75mm dia bore plain in cement concrete type B-1(1:2:4) and jointing to waste pipe complete including taking out old unserviceable floor trap all as specified and directed .
S & F in repair 110 mm PVC (SWR) floor trap plain in cement concrete type B-1(1:2:4) and jointing to waste pipe complete including taking out old unserviceable floor trap all as specified and dircted .
S & F in repair 75 mm PVC (SWR) floor trap plain plain in cement concrete type B-1(1:2:4) and jointing to waste pipe complete including taking out old unserviceable floor trap all as specified and dircted .
S & F in repair 100 mm dia CP grating plain including jointing with solvent cement complete all as specified and directed.
S&F in repair chromium plated health faucets (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hanging the faucet etc complete.
S&F CP jet spary for E W C with with adequate length flexible PVC pipe and connecting nipples complete all as specified.
S&F CP hand shower of 100 mm dia with arm and adequate length flexible PVC pipe and wall mounted pedestal for hanging the shower complete all as specified.
S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm etc complete all as specified.
S & F in repair for stainless steel plate rack of size 24"x36"x10" with shelves,hooks and railing to keep plates vertically and horizontally,including necessary fixing arrangement.etc complete all as specified and as directed.
S&F in repairs Vitreous China wash hand basin white with pedastal flat back size 550x400 mm including brackets, complete all as specified
S&F in repairs Vitreous China wash hand basin white with flat back size 550x400 mm including brackets, complete all as specified
S &F powder coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S &F powder coated aluminium window and ventilator shutters, side hung type without sash , aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 no) hinges type B-1 100 m long(2 Nos) suitable handle(1 Nos). and tower bolt 150 mm (2 No)complete al as specified.
S &F Anodised aluminum grill of approved pattern / design with approved standard section and fixed to the existing window frame with CP brass / stanless steel screws @200 mm centre to centre including cutting the grill to proper opening size fpor fixing and operation og handles and fixing approved anodiesd aluminium standard section around the opening all complete all as specified and all as dircteded.
S &F Powder Coated Anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws complete all as specified.
S &F for Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed.
S&L for sheet glass ordinary quality 4.80mm thick in aluminium windows of area of each pane exc 0.50 Sqm complete all as specificed and directed by Engr-in-Charge
S&L for 5.00 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane all as specified and as directed.
S&F factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick wood grain printed prelaminated moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specificatio n and all as directed.
S&F solid PVC door frame of size 50mm x 95 mm made out of 5mm thick wood grain printed PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-Charge.
S & F 35 mm thick factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated etc complete, all as specified .
S & F 35 mm thick 2nd class hard wood glazed and skelton shutter open rebated and prepared to receive glass ,gauge etc ( without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8 clause 8.24(a), supplied and fitted to chowkats.
M&L 2nd class hardwood as in plain, solid straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed
M & L for two coats of synthetic enamel paint over coat of pink primer on new wooden surfaces of any description not otherwise described over 10 Cm width or girth including preparation of surfaces complete all as specified and as directed by the Engineer-in-Charge
S&F extruded aluminium alloy handles of size 150 mm fabricated type omplete all as specified and as directed.
S&F 100mm stainless steel butt hinges, cold rolled medium weight complete all as specified and directed.
S&F 200 mm aluminium anodised barrel tower bolts of extruded section etc complete all as directed.
S&F extruded aluminium alloy handles of size 100 mm fabricated type omplete all as specified and as directed.
S&F 100mm mild steel butt hinges, cold rolled medium weight complete all as specified and directed.
S & F for galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by the Engineer-in-Charge.
S&F 250 mm aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) etc complete all as directed.
M&L for 18/19 mm Pre laminated block boards,interior grade,prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with nails and fixed to wall with scews or necessary fixing arrangent complete all as specified and as dircted.
M&L 6mm thick teak wood lipping for block board or veneered plywood 18/19mm thick, fixed with nails in repairs complete all as specified and directed.
S&F in repair continuous (piano) hinges, brass, bright finish width of flaps(when open) 30 mm complete all as specified.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified.
S & F in repair for hasp and staple 75mm size, safety type aluminium anodised including bolt to hinge plate and fixed to cup board shutter or kitchen cabinet shutters including taking out the existing complete all as specified and directed.
S&F in repair 300mm MS ordinary rat tail rod pattern spring including roller and roller plate fixed as in repair including taking down the unserviceable existing complete all as directed.
S&F in repair for curtain rod powder coated ornamental type dia 25 mm including taking out the existing complete all as specified and directed.
S&F in repair wall to wall brackets for 25 mm rods including taking out the existing complete all as specified & directed
S&F in repair for End cap for 25 mm dia ornamental type curtain rod taking out the existing complete all as specified & directed
M&L for 3.5mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane including hacking out of old glass (of any thickness and shape) in wood steel frame all as specified and directed
S & F in repair for galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 200 mm aluminium anodised barrel tower bolts of extruded section etc complete all as directed.
S&F extruded aluminium alloy handles of size 150 mm fabricated type fixed as in repair including taking down the unserviceable existing complete all as directed.
S&F in repair 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and as directed.
M&L in repair for floor door stopper of aluminium alloy body 150mm long and tongue, anodised with hard drawn steel spring fixed to door shutters complete all as specified and directed.
M&L for preparation of old decorated plastered / unplastered surfaces of wall including cornices, pillasters etc of bldgs and applying one coat of white wash complete all as specified and directed
All as per item No 106.00 but applying two coat of white wash on wall complete all as speciifed and directed.
All as per item No 106.00 here in before but one coat of white wash on ceiling and AC plain building board surfaces as in ceiling complete all as specified and directed
M&L for for applying 1 mm thick wall care putty of old decorated plastered or unplastered surfaces of wall complete all as specified and directed
All as per item No 106.00 above but one coat of cement based paint on walls complete all as specified and directed
All as per item No 106.00 above but applying two coat of cement base paint on walls complete all as specified and directed
M&L for preparation of plastered or unplastered old surfaces of walls and applying one coat of oil bound distemper of any approved tint complete all as specified and directed
All as per item No 112.00 but and applying two coats of oil bound distemper complete all as specified and directed
All as per item No 112.00 but complete removal of existing treatment and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed
All as per item No 112.00 above but one coat of oil bound distemper on ceiling and AC plain building board surfaces as in ceiling complete all as specified and directed
M & L for preparation of old painted wooden surfaces of any description position and location not otherwise described over 10cms width or girth and applying one coat of synthetic enamel paint (ordinary tint) all as specified and as directed.
All as per item No- 116.00 above but applying two coat of synthetic enamel paint complete all as specified and directed
M&L preparation of old painted steel surfaces exc 10cm in width or girth and appling one coat of synthetic enamel paint complete all as specified and directed
All as per itme No 118 above but two coat of synthetic enamel paint complete all as specified and directed
M&L preparation of old painted NTP/CGI/PGI or other steel roof surfaces, eaves and gutters etc exc 10 cm width or girth and applying one coat of synthetic enamel paint of any tint as approved complete all as specified
Preparing zinc or galvanised surfaces to receive painting , and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M&L preparation of old painted plastered wall surfaces and applying one coats of synthetic enamel paint of approved tint complete all as specified
All as per item No- 122.00 but applying two coat of synthetic enamel paint complete all as specified and directed
M&L disconnecting existing over head steel/PVC water tanks, setting aside (or lowering, if required) for repairs, cleaning etc and hosting if required, reconnecting and refixing in position including cleaning and removing all a scale and dirt etc from tanks and from mouth of circulating pipes etc capacity exc 250 ltrs but n. exc 500 ltrs complete all as specified and as directed
All as per item No 124.00 above but exc 500 Ltrs and n exc 1000 Ltrs capacity complete all as specified and directed
All as per item No 124.00 above but exc 1000 Ltrs and n exc 2000 Ltrs capacity complete all as specified and directed
Writing letters or figures ( block , Roman , Italic , indian) n.exc 30cm height all as specified and directed.
Writing Stops , commas, short lines dashes hyphens,brackets etc all as specified and directed.
M&L preparation of old plastered or unplastered surfaces of walls including complete removal of existing treatment by washing, rubbing down and stopping of previously treated surfaces and applying two coat of exterior emulsion paint over a coat of primer of approved tint and make complete all as specified and directed
M&L preparation of old plastered or unplastered surfaces of walls above but one coat of exterior emulsion paint complete all as specified and directed
Demoltion of RCC in chajjas all as specified
M&L for providing and erecting at site conventional steel Double scaffolding to reach at place of work on the external face of building including appraches, extensions, working platforms ladders, lifting tackle for men and materials etc all complete inclusive of covering by hessian cloth or tarpaulins, dismantling and taking away all materials after the completion of proposed work etc complete all as specified and directed
M&L for RCC 1:2:4 type B0 (using 12.5 mm graded stone agg as in chajja at any height complete all as specified and as directed (scaffolding shll be measured and paid seperately)
Use and waste form work to chajjas chulla hoods troughtsand similar items including edges at any height rough finished flat surface complete all as specified & directed
M&L for providing fabricating placing in position new reinforcement of any size as per site requirement including securing and anchoring and drilling holes inserting the ends and welding if required etc complete all as specified and directed(Dowel pins willl not paid seperately)
Taking down carefully aluminium/ copper conductor point wiring (light, fan, light socket, power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
M & L for point wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing sunken boxes for mounting of switch, socket etc incl taking down unsv if reqd complete all as specified and directed for the following :-
One Light/Fan point controlled by one, one way switch 6 Amp complete
One Bell point controlled by one, one way switch 6 Amp complete
One switch socket outlet 3 pin, 5 Amp on the independed board
One switch socket outlet 3 pin, 5 Amp on same board
All as per item No 137.00 here-in-before but 4.0 sqmm single core multi stranded copper conductor PVC insulated unsheathed (FRLS) cable 1100 volts incuding 4.0 sqmm stranded copper conductor (FRLS) PVC insulated greeen in colour as continous earth conductor connected to common earth and earth dolly with all accessories one 5 pin 16 Amp socket (Power point) on independent board complete all as specified and directed
M & L for point wiring with 1.5 sqmm single core multi stranded copper conductor PVC insulated unsheathed (FRLS) cable 1100 volts grade drawn through and including non metallic rigid PVC concealed/surface conduit 20mm dia or higher with all PVC conduit accessories with suitable size of anodised switch box concealed in wall for mounting of switches, sockets, fan regulators etc with 3mm thick ISI marked plastic laminated sheet with earth continuity conductor of size 1.5 sqmm single core copper conductor multistranded cable (FRLS) connected to common earth dolly for the following complete all as specified and directed :-
One Light/Fan point controlled by one, one way switch 6 Amp complete all as specified and directed.
One Bell point controlled by one, one way switch 6 Amp complete all as specified and directed.
One switch socket outlet 3 pin, 5 Amp on the independed board complete all as specified and directed.
One switch socket outlet 3 pin, 5 Amp on same board complete all as specified and directed.
All as per item No 139.00 here-in-before but 4.0 sqmm single core multi stranded copper conductor PVC insulated unsheathed (FRLS) cable 1100 volts incuding 4.0 sqmm stranded copper conductor (FRLS) PVC insulated greeen in colour as continous earth conductor connected to common earth and earth dolly with all accessories one 5 pin 16 Amp socket (Power point) on independent board complete all as specified and directed
M & L in replacement sub main wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc after incl down unsv if reqd all as specified and directed.
S & F in repair/replacement switch piano flush button single pole one way, 6 Amps, 240 Volt incl taking down unsv complete all as per specified and directed
S & F in repair/replacement bell push piano flush type 6 amps , 240V incl taking down unsv complete all as per specified and directed
S & F in replacement buzzer ding dong, AC 230 volts Single Phase incl taking down unsv complete all as per specified and directed
S & F in repair/replacement socket outlet 2-in-1 5 pin, 6 Amps flush type complete all as specified and as directed.
S&F in repair/replacement switch piano flush button single pole one way, 16 Amps, 230/240 V incl taking down unsv complete all as specifed and directed
S&F in repair/replacement socket outlet 2-in-1 5 pin, 6 & 16 Amps flush type incl taking down unsv complete all as specified and as directed.
S&F in replacement PVC Plug Top 5 pin, 6 & 16 Amps flush type incl taking down unsv complete all as specified and as directed.
S & F in repair/replacemnt ceiling rose surface, backelite, three terminal, 240 volts incl taking down unsv complete all as specified and directed.
S & F in repair/replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings incl taking down unsv complete all as specified and as directed.
S&F Wall mounted LED batten box type pre coated CRCA body suitable for retrofit LED tube rod 18/20 Watt fixed in repair incl taking down unsv complete all as specified and directed.
S&F LED self ballasted LED retrofit tube lamp 18 Watt with thermoplastic body min 1800 system lumens and builtin surge protection of 2.5 KV incl taking down unsv complete all as specified and directed.
S&F Wall mounted mirror light LED fitting self ballasted LED batten extruded thermoplastic body with PC diffuser in unique square shaped 10 /12 watt 2 Feet long CCT 6500K fixed in repair incl dismantling taking down unsv fitting any type complete all as specified and directed.
S&F Surface mounted LED bulk head 10 watt luminaire with ABS body & polycarbonate diffuser IP 65 including connecting to ceiling rose with 0.5 sqmm two core copper flexible conductor cable fixed in repair incl lamp incl taking down unsv complete all as per specified and directed.
S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 9 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
S&F self ballasted LED Retrofit Bulb 3Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, E-14 cap, (Thread type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
S&F self ballasted LED Retrofit Bulb 3Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, E-27 cap, (Thread type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
S&F LED Slim panel size 2'x 2' ,36/40 Watt recess/ surface mounting edge lit LED slim panel having white powder coated extruded aluminium body with high quality LGP and PMMA diffuser , separate HPF driver suitable for Armstrong and grid ceiling separate accessories for recess /surface mounting PCGLP 2X 2, CCT 4000K fixed in repair incl dismantling taking out unsv one of any make/ size complete all as specified and as directed.
S&F Recess mounting ceiling fitting 1'X4' LED 36/40 Watt light Edgelit slim panel having white powder coated extruded aluminium body with high quality LPG and PMMA diffuser. Separate HPF driver. Suitable for Armstrong and Grid ceiling, PF min 0.95 complete incl dismantling taking out unsv one of any make/ size complete all as specified and as directed (As per existing Sample).
S&F Recess mounting ceiling fitting 1'X1' LED 18/20 Watt light Edgelit slim panel having white powder coated extruded aluminium body with high quality LPG and PMMA diffuser. Separate HPF driver. Suitable for Armstrong and Grid ceiling, PF min 0.95 complete incl dismantling taking out unsv one of any make/ size complete all as specified and as directed (As per existing sample).
Supply and fixing building security LED light 25 Watt energy saving LED ASTRA NEO street light made up of pressure dia cast housing with toughened glass and high power LEDs with option of secondary optic with IP66 protection, efficacy : 110LM/W one GI medium grade 25mm dia bracket of total lenghth 50 cm incl 2 Nos MS Clamp and fastners after dismantling taking down unsv one all as specified and directed.
S&F MCB DB TPN 4 way double door, IP 43, CRCA sheet powder coated vertical type factory made suitable for incorporating MCB as out going and MCCB as incoming including connecting incoming and outgoing cables & blaking plate as required incl taking down existing unsv DB of any size and making good distrubed surface to match with existing complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB DB SPN 4 way double door, IP 43, CRCA sheet powder coated, factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables & blaking plate as required including taking out existing unserviceable DB of any size and making good disturbed surface to match with existing incl taking down unsv complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB DB SPN 8 way double door, IP 43, CRCA sheet powder coated factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables & blaking plate as required incl taking out existing unsv DB of any size and making good disturbed surface to match with existing incl taking down unsv complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB TPN 63 Amps, 10 KA 415 Volt, 50 Hz, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB SPN 32 Amp to 40 Amp, 10 KA, 240 volts, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB SP 6 Amp to 32 Amp 10 KA, 240 volts, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble)
S&F Single pole and neutral enclosure with a two pin and earth plug and socket board with IS 13032, IS 8623 complete with one single pole 20 amp MCB complete incl dismantiling taking out unsv complete all as specifed and directed by Engr -in-Charge.
S&F Heating Element ISI Marked round/ tringular base, push type or thread type including rubber washer for 1.5/2.0 KW suitable for geysers 25 Ltrs to 50 Ltrs capacity (as per existing sample) including taking down unserviceable complete all as specified and as directed.
S&F thermostat ISI Marked suitable for geysers 25 Ltrs to 50 Ltrs capacity (as per existing sample) including taking down unserviceable complete all as specified and as directed.
S&F Chromium plated connections 45 Cm long for Hot/Cold water of 15mm size with cromium nuts and washsers fixed as in repairs complete all as specified.
S & F in repair/replacement of PVC gang box suitable for 6 Amp Socket and 6 Amp switch complete all as per specifiec and directed
S & F in repair/replacement of PVC gang box suitable for 16 Amp Socket and 16 Amp switch complete all as per specifiec and directed
Supply only electric insulation tape heavy duty complete all as per specifed and directed
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sq. mm x 2 Core nominal cross section in service connections complete all as per specifed and directed.
S&F in Replacement Exhaust Fan 250mm plastic body , 1400 RPM with air delivery 1050 CMH including and taking down unserviceable, complete all as specified and directed
S&F in Replacement Exhaust Fan 300mm Sweep metal body (Heavy Duty), 1400 RPM with air delivery 1050 CMH including and taking down unserviceable, complete all as specified and directed.
Dismantling and taking out the unsv/burnt copper wire of the motor from the exhaust fan and rewinding the motor of the exhaust fan of any make of size 250mm/300mm sweep with super enamelled copper wire of same size guage and weight as per existing including necessary insulating material to gain desire RPM as per manufacture design and varnishing the winding with two coats of synthetic varnish including heat treatment oiling greasing complete and reassembling of all parts with testing on completion complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed cable in and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed in walls/roof/ ceiling with suitable size of sunk type MS anodised pressed steel terminal box for mounting of modular switches, sockets, fan regulator etc with modular with any colour suitable as per site requirement cover plate with frame for suitable module as per site requirements and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth of following, complete all as specified and directed
One light point/fan point controlled by one way 5 Amps SP switch
One bell point controlled by one way 5 Amps SP switch
One 3 pin 5 Amps socket outlet on same board with other switch
One 3 Pin 5 Amps socket outlet on independent board with other switch.
Ditto all as per item No 180.00 above but with 4 Sqmm cross sectional area electric cable for 15 Amp socket outlet on independent board, complete all as specified and directed.
Ditto all as per item No 180.00 above but point wiring with and including PVC casing & caping, complete all as specified and directed for the following :-
One light point/fan point controlled by one way 5 Amps SP switch
One bell point controlled by one way 5 Amps SP switch
One 3 pin 5 Amps socket outlet on same board with other switch
One 3 Pin 5 Amps socket outlet on independent board with other switch.
Ditto all as per item No 182.00 above but with 4.00 Sqmm cross sectional area electric cable for 15 Amp socket outlet on independent board, complete all as specified and directed.
S & F modular switch 1 way 6 Amp , suitable module and proper colour as per site including taking down unsv complete all as specifeid and directed
S & F modular switch 1 way 16 Amp , suitable module and proper colour as per site including taking down unsv complete all as specifeid and directed
S & F modular SOCKET 6 Amp -2/3 pin combined, suitable module and proper colour as per site including taking down unsv complete all as specifeid and directed
S & F modular SOCKET 6 Amp/16Amp -2/3 pin combined, suitable module and proper colour as per site including taking down unsv complete all as specifeid and directed
S & F modular bell push 6A.230 Volts single pole, suitable module and proper colour as per site including taking down unsv complete all as specifeid and directed
S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 18 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
Amount of credit of Rs. 40317.90 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
RAJESH BUILDERS
Durga Construction
R. P. Suppliers and Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .