Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.7 L+₹1.7 L (5.86%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.9 L+₹2.9 L (10.1%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹38.1 L+₹9.1 L (31.3%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Jun 2024, 6:00 pmClosed
Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Upkeep and maint of sewer network in Fort Cantt Prayagraj.
2024_MES_656781_1
8735/E8
Open Tender
Civil Works
Item Rate
270 days
Prayagraj
As Per NIT
6 documents required · 6 mandatory
₹500
Yes
GE (East) Prayagraj
₹90,000
Yes
2 Sept 2024
30 May 2024
4 Jul 2024
30 May 2024
27 Jun 2024
13 Jun 2024
30 May 2024 - 6 Jun 2024
Amount
Attending daily complaints related to Cleaning of blocked WC seat of pedestal/squattern pattern upto Ist manhole and making the drain pipe of any size full fuctional by flushing with water to entire satisfaction of engr-in charge including cleaning of 1st manhole and removing the waste material/sludge etc to a distance n. exc 300m and burning the same in pits complete all as specified and directed by Engr-in -charge. T&P for attending the job will be provided by the contractor. Note :- (i) T&P including convence to reach door to door for attending the jobs will be provided by the contractor. (ii) The complaint slip will be collected from complaint cell incharge/JE(Civ) by the contractor or auth rep in writing. (iii) Each complaint shall be attend on same day and will be resolved within 48 hours otherwise contractor shall be liable to pay a panelty of Rs. 50/- per unresolved complaint per day subject to maximum Rs.1000/- per unresolved complaint. (iv) The area/Location of of Job will be all MD and OTM accn in AOR of OD Fort Cantt.
Attending complaints related to Cleaning of blocked floor trap of bath room &kitchen etc upto 1st manhole including cleaning of gully/trap and removing the waste material/sludge etc ta a distance n. exec 300m and burring the same in pits complete all as specified and directed by Engr-in -charge. T&P for attending the job will be provided by the contractor. Note :- (i) T&P including convence to reach door to door for attending the jobs will be provided by the contractor. (ii) The complaint slip will be collected from complaint cell incharge/JE(Civ) by the contractor or auth rep in writing. (iii) Each complaint shall be attend on same day and will be resolved within 48 hours otherwise contractor shall be liable to pay a panelty of Rs. 50/- per unresolved complaint per day subject to maximum Rs.1000/- per unresolved complaint. (iv) The area/Location of of Job will be all MD and OTM accn in AOR of OD Fort Cantt.
Excavation in trenches in any type of soil n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes and n exc 10 sq m on plan and getting out complete all as specified and directed.
Excavation in trenches exceeding 1.5m but not exceeding 3m deep and getting out in any type of soil complete all as specified and directed.
M&L PCC 1:4:8 Type D2 using 40mm graded stone aggregate in foundation ,fillings and mass concrete complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed .
M&L for (except brick) work with sub class 'B' brick straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed .
M & L 15mm thick plastering on other than fair faces of brick wall in CM (1:4) surface finished, even and fair without using extra cement complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; basesfor columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for factory made pre-cast RCC (M-20) 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab of manholes, septic tanks, etc. and set in cement mortar 1:4 including steel reinforcement 10mm dia and dismantling of damaged RCC covers slab complete all as specified and as directed.
M&L for Pre-cast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab of manholes, septic tanks, etc. and set in cement mortar 1:4 including dismantling of damaged RCC covers slab complete all as specified and as directed. NOTE : Reinforcement will be measured and paid for separately under relevant Item(s).
M&L mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending, spirally for hooking for hooking and binding with including mild steel annealed wire not less than 0.9 mm dia securing with clips complete all as specified and directed.
M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Use and waste form work in flat surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Use and waste form work in flat surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work complete all as specified and directed.
De-Sludging of Septic tank or Choked Manholes of any description with sewage pump after plugging of incoming sewage line and throwing the sewage/Sludge into designated area of Sewage treatment plant all as directed by Engineer in Charge
Cleaning of underground Sewer pipes of dia upto 300mm including manholes by rodding from manhole to manhole, manhole to septic tank ,flushing with water ,taking out sludge and other materials by blocking of drain pipes, carrying/ removing the same to a distance not exc 50m and bringing in pits including covering the pits with soil in layers 45cm thick complete all specified and directed.
S&F in repair Vitreous china, wash hand basin, (white) of size 550mmx400mm including brass CP waste coupling 32mm dia with long screwed shank and fly nuts, , chain and plug, porcelain stopper ,pvc connection 15mm dia 450mm long with brass CP nuts and washers at both ends, and including taking down unserviceable WHB and connected items of any description, complete all as specified and as directed.
S&F in repairs Vitreous china squatting pan ‘Orissa’ pattern, size 580 x 440 mm, white coloured, with integral foot rests, including provision of lime concrete bedding and including taking down unserviceable WC pan and connected items of any description, complete all as specified and as directed.
M&L in repair Vitreous china coloured wash down water closet pan (Padestal Pattern) and trap (CI 'P' or 'S' type), including connection to drain or outgoing pipe and to flush pipe, anti-syphonic pipe etc. including rovision of PVC seat cover fixed with chromium plated mild steel hinges device, and including taking down unserviceable WC pan and connected items of any description, complete all as specified and directed .(Make- Cera, Parryware, Hindware)
S&F in repair Plastic water closet seat black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair mild steel chromium plated health faucet with min 1.5m long flexible pipe including necessaey arrangement for hanging and connection to GI pipe or stop valve complete all as specifird and directed.
S&F in repair 10 litre capacity PVC, low level, valveless, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement, 32 mm dia PVC flushing pipe and 15mm dia 450mm long PVC connection with CP brass coupling nuts and PVC washer at both ends , complete all as specified and directed .
S&F in repairs PVC long flush bend of 32 mm dia for PVC flushing cistern of any shape or make of 10 lit capacity complete all as specified and directed.
S&F in repair Bib tap, cast copper alloy, fancy type, screwed down for high pressure screwed for 15mm bore pipe , complete all as specified and directed .
S&F in repair Pillar tap, cast copper alloy, with capstan head, chromium plated screwed down high pressure, with or without lettered hot/cold with long screwed shanks and fly nuts screwed for iron pipe 15mm bore, complete all as specified and directed .
S&F in repair 15mm bore stop /angle valve , cast copper alloy, screwed down, high pressure with crutch or butter fly han-dle, screwed both ends for iron pipe or union, complete all as specified and directed.
S&F in repair 15mm bore stop valves, cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or union , complete all as specified and directed .
S&F in repair PVC connection suitable for 15mm pipe with PTMT nuts and washers for both ends, 450mm long, , complete all as specified and directed .
S&F in repair of PVC waste pipe, medium grade, 32mm dia and 750mm long, complete all as specified and directed .
Supplying, laying, jointing and testing in trenches DWCPE (SN 8) nominal size 100 (ID)/108 (OD) dia as per IS-16098 (Part 2) : 2013 upto a depth of 1.65m with and including all items and activities required to make sewer line functional and taking out demolition drain/sewer pipes 100mm of SGSW/PVC (Salt glazed ware, AC or Reinforced concrete) set in cement mortar from trenches complete all as specified and as directed.
Supplying, laying, jointing and testing in trenches DWCPE (SN 8) nominal size 163 (ID)/180 (OD) dia as per IS-16098 (Part 2) : 2013 upto a depth of 1.65m with and including all items and activities required to make sewer line functional and taking out demolition drain/sewer pipes 150mm of SGSW/PVC (Salt glazed ware, AC or Reinforced concrete) set in cement mortar from trenches complete all as specified and as directed.
Supplying, laying, jointing and testing in trenches DWCPE (SN 8) nominal size 175 (ID)/200 (OD) dia as per IS-16098 (Part 2) : 2013 upto a depth of 1.65m with and including all items and activities required to make sewer line functional and taking out demolition drain/sewer pipes 200mm of SGSW/PVC (Salt glazed ware, AC or Reinforced concrete) set in cement mortar from trenches complete all as specified and as directed.
Supplying, laying, jointing and testing in trenches DWCPE (SN 8) nominal size 260 (ID)/300 (OD) dia as per IS-16098 (Part 2) : 2013 with and including all items and activities required to make sewer line functional and taking out demolition drain/sewer pipes 250/300mm of SGSW/PVC (Salt glazed ware, AC or Reinforced concrete) set in cement mortar from trenches complete all as specified and as directed.
M&L for making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. for pipes upto dia 300mm complete all as specified and directed by EIC.
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and choking of sewer lines. Choking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 100 mm dia upto 300 mm complete all as specified and directed by EIC. Note :- Sewer cleaning machine will be made available by the contractor only 2 times in a month as and when needed and required by the Engineer-in-Charge. Only number of hours machine operated will be recorded in MB for payment purpose.
S&F PVC (SWR) 110mm bore, pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by EIC.
S&F PVC (SWR) 110mm bore, pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by EIC.
S&F PVC (SWR) 110mm bore, bends any type, any radius with access door/plain and jointing with solvent cement, complete all as specified and as directed by EIC.
S&F PVC (SWR) branch piece, single (single Y) equal or unequal access door for 110mm bore pipe complete all as specified and as directed EIC.
S&F PVC (SWR) 75mm bore, pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed EIC.
S&F PVC (SWR) 75mm bore, pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed EIC.
S&F PVC (SWR) 75 mm bore, bends any type, any radius with access door/plain and jointing with solvent cement, complete all as specified and as directed EIC.
S&F PVC (SWR) branch piece, single (single Y) equal or unequal access door for 75 mm bore pipe complete all as specified and as directed EIC.
S&F PVC (SWR) vent cowl for 100 mm bore pipe complete all as specified and as directed EIC.
S&F PVC (SWR) vent cowl for 75 mm bore pipe complete all as specified and as directed EIC.
Dismantling posts or struts (wood, steel or R.C.C.) any section, embeded in concrete including taking out embedded portion and making good disturbed ground
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
Surface dressing n exc 15 cm deep and getting out as in soft/loose soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out and getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point as in soil complete all as specified and directed.
M&L for providing plain cement concrete type D2, 1:4:8 using (40mm graded stone aggregate ) as in foundation complete all as specified and as directed
M&L for providing plain cement concrete type B1, 1:2:4 using (20mm graded stone aggregate ) as in foundation complete all as specified and as directed
M& L for 25mm thick Sand filling under floors or in foundations base of inter locking PCC tiles including watering and consolidation complete all as specified.
M&L Machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
S&F for rolled mild steel Fe-410 (Grade E-250A) angle or tee section as in post, cut to length and bend to shape as directed, fixed independetly without connecting plate etc, including provision of 05 to 06 Nos gaps/cuts/holes in each post for providing/laying barbed wire complete all as specified and as directed. (Note :- Supply and fix barbed wire shall be measured and paid separately)
Supply and fix galvanised , 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and staining and fixing to any type of standard rails, straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as specified and as directed. (Note :- Each line of wire to be measured)
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Supply only Chain link MS galvanisd fencing, any size or type complete and all as specified and directed.
S&F fibre glass 2mm thick reinforced translucent coloured, plain/corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as directed by Engineer-in-Charge.
M&L for Preparing of new plastered or unplastered surfaces of walls and applying two coats of cement base paint in approved colour/shade over a coat of primer complete all as specified and directed.
M&L for preparation of new steel or iron surface of any description, exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete and all as specified and directed.
M&L for preparation of new steel surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint over a coat of red oxide primer complete and all as specified and directed.
ANKIT SHIP REPAIRERS AND SUPPLIERS
vs construction
PITAMBARI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .