Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock wood 30 mm thick shutters
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm
Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete :
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm
Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 90 mm
Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 250 mm weighing not less than 150 gms.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick plain PVC door shutters.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches including cutting the patch in proper shape, raking out and preparing and plastering the surface of on the terrace complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. With cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement.
Neat Cement punning
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. With cement mortar 1:4 (1 cement : 4 fine sand).
Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. Sal wood battens.
Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
Removing glass panes from windows and replacing them with new glass panes with putty and nails wherever necessary : float glass panes of thickness 4mm
a) for windows in ground floor and /or for windows which can be accessed from inside of the room / bolcony with ladder arrangement wherever necssary.
b) for windows in upper floors ( other than ground floor ) up to 5 floors with necessary Scaffolding/Jhoola arrangement
Uprooting & removal of plants/small tree grown on exterior faces of walls at all levels ,any location and applying special chemical to defective area to prevent tree growth and finishing the same with cement concrete/mortar to match the surface of walls etc complete as per the directions of engineer-in-charge(cement concrete/ mortar to be paid in separate item.)
Up to floor two level
Above floor two level
Cleaning of existing sanitary pipe alignment of 160/110 /75 mm dia in vertical and horizontal direction of all floors and all heights by opening door bend , clearing the deposited obstacles including rodding and refixing the doors with new rubber washer and jointing the same job includes replacing door covers bolts and nuts wherever required to arrest the leakage all as per directions of Engineer-In-Charge(opening of each door bend and removal of blockages including above operations will be measured as one job.)
Cleaning of exisitng sewer lines, manholes etc. Cost includes all labour for removing the silt, slush, waste etc. and rodding the sewer lines and manholes by mobile sewer rodding equipment/manually from manhole to manhole to clear the blockage, chokages etc for proper functioning of sewer lines( The payment shall be made for removal of blockages in between manhole to manhole as one job with all above operations.)
Providing and fixing Pre-cast RCC gully trap cover of approved make or equivalent of 25mm thickness of size 300 x 300 mm or of required size as per requirement for existing gully trap with necessary repairs etc all complete as per the directions of Engineer-In-Charge
Providing and fixing MS clamps with flat 20 x 3 mm to existing C.I./PVC pipeline of diameter 75mm to 100mm with necessary screws, nails including wooden plug and as per the directions of Engineer-in-charge. (each clamp with wooden plug is measured for payment)
Charges for Engaging carpenter / plumber /Mason/Welder along with helper whereever required for attending minor repair works in the compound etc., complete as directed by the Engineer-in-charge. (The required fittings & fixtures exept screws/nails, drilling etc.shall be paid separately and measured for each half day)
Pointing of tile joints with poly sulphide/white cement up to 2mm depth by removing existing damaged/loosened white cement from joints to arrest leakage at all levels as directed by engineer in charge(Area of tiled flooring/ dadoo where above operations are made is measured for payment)
Carting out of building rubbish / malba / similar unserviceable, dismantled, excavated or waste materials by mechanical means,through private carrier including lifting, loading, transporting, unloading to municipal dumping ground beyond 50 m initial lead,or in any other compound as decided by the Engineer-in-charge, for all leads including all lifts involved.
Charges for arranging the welding plant with attendent at site including to and from the shop, for all welding repair works to doors, windows etc., in site including providing necessary power supply arrangements, lugs etc., complete as per the direction of Engineer-in-charge for attending repairs in all quarters.
Removing of existing PVC water storage tanks by removing existing GI connection, float valve, including repairing of the tanks and refixing the same on the base with all the GI connections, float valve and other accessories etc all complete as per the directions of Engineer-In-Charge.
Cleaning of existingType-I / Type-II or Type-III/IV staff quarter at all heights by removal of cob web, pigeon droppings, debris, unwanted, un serviceable abandoned material etc from all the rooms, dusting of walls, windows, doors, cubboards etc, washing the flooring of all rooms with detergent, washing the flooring and dado of toilets and bath room with the acid etc.,making them into useable/liveable conditions complete etc for immediate occupation of quarter as directed by Engineer-in-charge.Each quarter cleaning is measured as one job.
a)T-I/ transit Qtr
b)T-II Qtr
c)T-III Qtr
Providing and fixing CPVC fittings like coupler, elbow, reducers, plastic threaded male/ female adapters etc in new CPVC pipe including cutting pipes wherever required and fittings with one step CPVC solvent cement etc complete.
25 mm nominal bore.
32 mm nominal bore.
40 mm nominal bore.
50 mm nominal bore.
Replacing old/ rusted GI water supply pipeline by providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of SDR 11 (Class 1) confirming to IS: 15778, having Internal - Exposed on walls or Ground thermal stability for hot & cold water supply including all plain/reducing fittings with plastic or brass threadings except union and ball valves including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
25 mm nominal dia Pipes
40 mm nominal dia Pipes
50 mm nominal dia Pipes
Providing and fixing CPVC Union in new CPVC pipe including cutting pipes wherever required and fittings with one step CPVC solvent cement etc complete.
25 mm CPVC Union
40 mm CPVC Union
Cutting /Pruning branches of trees for avoiding entering houses and obstructing colony lighting and electrical wire free passing and disposing the cutting pieces away from the compound to the dumping ground as directed by the engineer-incharge. (Pruning/cutting of each branches for each tree will be measured as one job)
Cleaning of terraces by removing leaves grass dust, rubbish and other deposited / accumulated materials etc including removal of blockages/chockages of khurras/spouts of terrace/chajjas at all hieghts etc and disposal of rubbish to the dumping ground out side periphery of the building. ((entire Terrace of one building shall be measured as Two unit for payment). all complete and as per direction of Engineer in charge a) Terrace area connected to blocked khurras and spouts & like.
Cleaning of canopy/ chajjas by removing leaves grass dust, rubbish and other deposited / accumulated materials etc including removal of blockages/ chockages of khurras/ spouts of terrace/chajjas etc by disposal of rubbish to the dumping ground out side periphery of the building.
Blocked chajas, in accessible canopy & like upto First floor level .
Blocked chajas, inaccessible canopy & like Above first floor level .
Cleaning of Under ground water storage tank or sump or over head tank of any capacity by following method: (1) Empty the tank/sump and make it to near dry, (2) Apply bleaching powder uniformly ( tank capacity @ 0.50gms/liter) surface of inside the tank/sump perfectly by removing scales on walls and wait for one hour (3) after one hour clean/rinse at the tank/sump with fresh water ,repeat the above process , (2) and (3) for two to three times , (4) remove the mud/silt/sludge and garbage from the tank with specified sludge pump, (5) spraying anti bacteria agents on walls to kill harmfull bacteria. Rate includes for all above operations including the equipment and material required for cleaning all complete as directed by the Engineer-in-charge. Liquid capacity of water tanks of any capacity in litres is measured for payment.(The rate includes filling of outlets of tank with cotton during cleaning marking of date of painting on the tanks and cleaning of all the dirt/ waste etc., from the terrace and submission of certificate from specialised agency).
a)Under ground water storage tank or sumps
b) Over head tanks at all levels
Providing and fixing/ replacing set of M.S brackets of required size for wash basin including painting to brackets fixing with CC 1:1.5:3 i/c removing the existing wash basin and refixing the same after fixing MS brackets etc., all complete as per the directions of Engineer-in-charge.
Replacing existing damaged floor tiles at different locations with ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make matching with existing flooring in color and shade on 20mm thick bed of Cement Mortar 1:4(1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete by carefully removing existing damaged tiles without damage to edges of adjacent tile flooring including dismantling existing bed mortar and disposal of debris to nearest dumping within compound yard all complete as directed by Engg-in-Charge.
Providing and fixing unplasticised -PVC pipe clips of approved design for fixing of unplasticised - PVC pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting chases in brick work, fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall with rich cement plaster etc. complete.
Cleaning of blocked Nahani trap / floor trap in toilets for removal of blockages including removing the silt , slush,, waste etc ensuring smooth flow etc., and applying white cement and fixing the grating with white cement and disposal of all unwanted material to the approved muncipal dumping yard and flooring around the trap wherever required to arrest the leakage all complete and as per direction of Engineer in charge
Clearing chokeage of exisitng gully trap. Cost includes all labour and material required for removing the silt, slush, waste etc. and rodding the sewer line from gully trap to manhole to clear the blockage, chokeage etc for proper functioning of sewer lines (The payment shall be made for removal of blockage in between gully trap to manhole as one job with all above operations.) disposal of all unwanted material to the approved muncipal dumping yard etc all complete and as per direction of Engineer in charge
Removing the broken pipe/ coupling from the water line, cutting to required size, replacing with suitable uPVC pipe / uPVC coupling with the help of solution and refixing the pipe in original position on emergency basis (breakdown operartion) complete as directed by the Engineer-in-charge.
Repairs to PVC flush tank including cleaning the durt/ scales with acids, adjustment in the flush mechanism etc, all complete and as per direction of Engineer in charge
by replacing the lever or handle wherever required but without changing the internal syphon set
By replacing the lever or handle wherever required including changing the internal damaged syphon set
Minor Repairs to the existing wooden doors /windows shutters by removing and refixing the same after attending necessary repairs etc. with necessary screws, nails ,hinges etc wherever required complete to make it working condition (Each door/window irrespective of size will be measured for payment cost of Hinges, handles and other accessaries if any will be paid separately) all complete and as per direction of Engineer in charge.
Replacing access door bend cap/cover of MS sanitary/rain water pipes either made of PVC/MS sheet & applying cement etc and to make it water tight as directed by Engineer in charge.
Repairs to floor/Nahani traps in toilets includes the following operations a)dismantling the flooring tile and lime concrete etc., around the nahni or floor trap carefully to expose the joint of trap. b)Dismantling the extension piece above floor trap and providing new extension piece of PVC pipe of appropriate diametre including filling with cement mortar 1:1(1cement:1 fine sand) . c)testing water joint for water tightness. d)Providing and laying of ceramic tile on a bed of 30mm average thickness for the damaged portion to match with the shade of existing tiles including pointing with white cement mixed with pigment to match the shade of existing tiles all complete as per the directions of Engg-in-charge.
Providing and fixing of 'P'or'S'trap for water closet in toilets including making good the walls and floors all complete as per the directions of Engg-in-charge. a)100mm dia SCI as per IS:3989
Providing and filling cement motar sanded grout mixed with Fosrock liquid water proofing compound in required quantity for grouting/ filling around the gaps of IWC, floor traps sides and inside traps including finishing the sides neately and grouting in holes at door bottoms etc., complete in the toilet rooms to fill the holes terrazo/ ceramic flooring tiles, around the W.C.pans, corners of rooms, floor trap openings after neatly cleaning/ scratching the joints etc., in all floors complete as per directions of Engineer-in-charge. (No. of quarters shall be measured for payment)
Charges for making the steel window shutters freely to move by oiling the hinges , cleaning of rust on all sides etc at all levels ., complete as per the direction of Engineer-in-charge.
Providing fixing/replacing stainless steel grating to floor trap of required size and shape and finishing with white or grey cement etc all complete as per directions of Engineer-in-charge..
Providing and fixing clamps to existing GI pipeline laid on walls of diametre 15mm to 40 mm with necessary screws, nails including wooden plug etc., at all levels and as per the directions of Engineer-in-charge.Rate includes removing and refixing of GI pipe lines wherever required.
Removing and refixing CP pillar cock by replacement of internal fitting such as Gadda etc & making it into workable condition complete as per the directions of Engineer-in-Charge.
Providing repairs by tightening of the existing pillar cock/bib cock/stop cock etc for proper functioning etc., complete as directed by the Engineer-in-charge.
Supplying and fixing in position precast RCC Man hole cover for chambers , frame of square of size of approved make.The cover should be 40mm thick and provided with required quantity of reinforcement.The frame shall be fixed in cement mortar over the manhole opening and rounding of edges etc. shall be made complete all as per the directions of engineer-in-charge.
Cleaning of existing Septic tank by mechanical pumping mechines and necessary labour including providing/spreading atleast 5liters kerosine on top of sludge inside the septic tank to avoid foul smell for the surrounding occupants, the deposited sludge/suspended material/night solin etc., should be removed and transported by mechanical transport beyond municipal limits including dewatering of liquids as directed by the engineer-in-charge.
Providing and fixing PTMT/PVC health faucet with PVC pipe including holder complete etc., as directed by the Engineer-in-charge.-15 mm dia
Providing and fixing PVC OH water tank covers to OH tanks with screws, removing & disposal of old covers complete at all levels etc., as directed by the Engineer-in-charge.
Providing and fixing MS oxidized casement handle made of ms coatedfor MS casement window with necessary screws etc. complete. 100mm
Cleaning of the surroundings of the staff quarters block including removing the dust, dead leaves, silt, waste etc., and disposing the waste out side the compound etc., complete as per the direction of the Engineer- in-charge.
Identifying ,treating and rectifing the water leakage from the CGI sheet roofing and providing & fixing nuts and washers of J or L hooks to CGI sheet roofing & providing necessary black putty/bituminous sheet to protect against leakage (area of roof up to 5 Sqm) as directed by the Engineer-in-charge.
Providing and applying heavy duty reinforced acrylic waterproof coating for terrace NEWCOAT of Dr. Fixit(604) or equivalent ,composed of specially developed highly elastic and resilient acrylic polymers etc. and applied over surface( as per manufacturers specifications Dr Fixit 603 & 604 )in three coats @ 2 Sqm/Litre including a priming coat of Primeseal(603) @ 7 Sqm/Litre etc. complete as directed by the Engineer in charge.
Trimming of branches of old trees having girthed (measured about height of 1.00 metre above ground level) including making necessary arrangement for climbing holding trunks with rope, trimming of branches and disposal of trimmed branches outside premises/ compound as directed by EIC.
Providing & fixing 0.50 mm thick Aluminium sheet to toilet door shutters including cutting & folding in required size and shape with necessary screws, nuts etc including removing & refixing the shutter as per direction of Engineer
Easing of wooden door and windows by removing and refixing including refixing old or missing screws if required as directed by Eng-in-Chagre complete
a) Doors (area up to 2.50 sqm)
b) Windows(area up to 1.50sqm)
c) Cupboards(area up to 2.50sqm)
d) Pelmets upto 4.0m length
Providing and making one time bamboos scaffolding arrengement for fixing glasses in windows,CPVC pipe,rainwater/swr pipes, up to 3nd floor height and area covered up to 1.5 metre width including movement from one place to another place as and where required in staff quarter compound complete as directed by engineer in-charge.
Providing CPVC Ball Valve of approved quality as directed by Engineer In-charge.
a) 15 mm dia
b) 20 mm dia
c) 25mm dia
d) 40 mm dia
e) 50mm dia
Providing CPVC Tank Nipple of approved quality as directed by engineer In-charge a) 25mm dia
Supply of U-PVC pipes (working pressure 4 kg / cm²) Single socketed pipe
110 mm dia
75 mm dia
40 mm dia
Providing PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5°
110 mm dia
75 mm dia
40 mm dia
Single tee without door
75 mm dia
40 mm dia
110 mm dia
Providing PVC tank cover for PVC tank
Providing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm dia
40 mm dia
Providing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
32 mm dia
40 mm dia
Providing spindle for tap,piller cock
15mm dia bib/stop cock
Piller cock
Basin mixer piller cock
Providing white vitreous china wash basin
White plastic seat (solid) with lid C.P. brass hinges and rubber buffers
Unplasticised P.V.C. connection pipe with brass union 45 cm long 15 mm bore
Providing flushing cistern fittings
PVC Knob
Syphon kit for flushing cistern i/c handle
Providing flushing cistern a) 10liter capacity
Providing P.V.C. waste coupling for sink or wash basin including P.V.C. waste fittings complete.
32 mm dia
40 mm dia
Providing polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings .
Credit for taking away the unserviceable GI pipes etc., scrapping and disposal of old dismantled/recovered including dismantling of existing damaged lines for replacement at all levels etc., complete. material from the work a) Unserviceable G.I.pipe
a) 15mm dia GI pipe
b) 20mm dia GI pipe
c) 25mm dia GI pipe
d) 40 mm Dia GI Pipe
e) 50 mm dia GI Pipe
Credit for taking away the unserviceable CP/Brass fittings etc., scrapping and disposal of old dismantled/recovered including dismantling of existing damaged lines for replacement at all levels etc., complete. material from the work
a) 15 mm nominal bore stop/bib,piller cock
b) 20mm dia stop cock
c) 25mm dia gate valve
d) 40mm dia gate valve
e) 50mm dia wheel valve
Credit value for old unserviceable dismantled material. a)old unserveciable door shutter
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .