| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC AZARA GUWAHATI ASSAM 781017 | KAMRUP METRO | ASSAM | 781017 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹33.9 L+₹36,417.58 (1.09%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.6 L+₹1.1 L (3.31%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹34.7 L+₹1.2 L (3.69%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹35.3 L+₹1.8 L (5.30%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹30.0 L
EMD Value
₹59,920
Closing Date
9 Jun 2022, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Repair/Replacement of MCB DB, Submain Wiring, replacement of Energy meter, Electricals fitting/fixtures and allied works at Mountain Shadow in 19 Wing Under GE (AF) Borjhar
2022_MES_525205_1
8279/BOR/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Borjhar
MES Contractor enlisted as Class E category b(i) having deposited Standing Security of Rs 50000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹59,920
Yes
16 Aug 2022
20 May 2022
11 Jun 2022
20 May 2022
9 Jun 2022
2 Jun 2022
Amount
SCHEDULE 'A'/BOQ OF MOUNTAIN SHODOW
Taking down existing sub main wiring of any type/size complete from wall and making good the disturbed surface complete all as specified and directed.
S&F for Sub main wiring two single core PVC insulated unsheathed FRLS multistranded copper conductor cable of size 10.0 Sqmm (Nominal area), 1100 V grade and one run of 6.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed muti stranded copper conductor cable as in earth continuity conductor drwan through in and including PVC Casing-in-Caping of required size (ISI marked) with all accessories on roof/wall/ceiling and making good the disturbed surace with cement sand plaster (1:6) and white washing/distempering to match the existing surface complete all as specified and directed.. Note:- Two runs of 10.0 Sqmm cable and one run of 6.0 Sqmm earth wire and one run of PVC casing-in-caping shall be measured as one unit length.
All as per Item No 3.00 here in before but sub main wiring with two run multi standard FRLS PVC insulated unsheathed copper stranded conductor of size 6.0 Sqmm and one run of size 4.0 Sqmm for continuous earthing.
All as per Item No 3.00 here in before but sub main wiring with two run multi standard FRLS PVC insulated unsheathed copper stranded conductor of size 4.0 Sqmm and one run of size 2.5 Sqmm for continuous earthing.
Taking down unserviceable rusted/damaged sheet metal enclosure DBs of any size/type/ways from wall carefully and making good to disturbed surface of wall complete all as specified and directed.
Supply and fixing powder coated sheet metal enclosures load line MCB DB VTPN 4 way double door, made out of CRCA mild steel surface with insulated material like polyster with epoxy surface stove enameled dust and vermin proof IP-43, 4 way 415 Volt fitted with bus bar, DIN channel, neutral link suitable for incorporation of MCCB's & MCBs complete all as specified and directed..
Supply and fixing powder coated sheet metal enclosures MCB DB TPN 4 way double door, made out of CRCA mild steel surface with insulated material like polyster with epoxy surface stove enameled dust and vermin proof 4 way 415 Volt fitted with bus bar, DIN channel, neutral link suitable for incorporation of MCB's and isolator etc complete all as specified and directed .
S & F for Sheet metal enclosure double door (IP-43) DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy surface mounting SPN, 8 way, 240 volt complete with neutral link and earth link complete all as specified and as directed.
All as per item No 07 above but DB DD SPN12 way complete all as specified and directed .
All as per item No 07 above but DB DD SPN16 way complete all as specified and directed.
All as per item No 07 above but DB single door SPN 2 way complete all as specified and directed
S&F in replacement of MCB, SP, 240V, 6 to 32 Amps breaking cap 10 KA, 'B' curve complete all as specified and as directed.
All as per item No 13 above but MCB DP 6 to 32Amps, 'B' curve 240 volts complete all as specified and directed.
All as per item No 13 above but MCB SPN 40 to 63Amps, 'B' curve 240 volts complete all as specified and directed .
All as per item No 13 above but MCB TPN 63 Amps, 'B' curve 415 volts complete all as specified and directed .
Supply & Fix in replacement of recess mounted LED panel light fitting of 36 watt (2x2), suitable for 240 volt, made from extruded aluminium frame and super bright LEDs including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply & Fix in replacement of recess mounted LED panel light fitting of 20 watt (1x1), suitable for 240 volt, made from extruded aluminium frame and super bright LEDs including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply & Fix in replacement of recess mounted round slim and dlegant downlighter LED panel light fitting of 10 watt, suitable for 240 volt, made from extruded aluminium frame and super bright LEDs including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .Make : Havells/Bajaj/Phillips
S&F in replacement of building security light LED fitting 20 watt , 230 Volt AC with IP 66 protection with aluminium housing pressure die cast housing having heat dissipating fins for large surface area, matt finish powder coated in grey paint, toughened glass in the front and peanut lens for batwing light distribution, CCT 5700, CRI > 70, power factor > .95, IP 20, surge protection 4 KV internal, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection and fix on wall on existing bracket and connecting up to ceiling rose with three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit complete including taking down old u/s light fitting and deposited to E/M store yard.
S&F in replacement of bracket for bldg security light fittings of any size made out of GI pipe light grade 40 mm dia 1.5 mtr length bend to required size and shape including provision of two Nos of MS strip welded with MS pipe and fixed over wall properly by grouting 04 Nos fasterns and one coat of aluminum paint over a coat of red oxide primer including taking down old u/s bracket complete all as specified and directed .
Supply 1100 Volts PVC insulated and PVC round sheathed multicore bright annealed bare copper conductor heavy duty flexible cable confirming to IS-694 : 2010 of size 0.5 sqmm 2 core complete all as specified and directed by Engr in charge. Make:- Polycab/Finolex/Gloster/Havells
M&L for fixing of PVC rectangular block with 3mm thick plastic laminated sheet cover of size 100x100x50mm depth by grouting 02 Nos screws on wall and including fixing over a 6A batten lamp holder with metal rings suitable for 240 volts, 50 Hz and connection of necessary electrical connection complete all as specified and directed .
S&F 1100 volts grade heavy duty cable PVC insulated Stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1metre apart including 4mm suspension wire, two core cable flat or circular of 10 Sqmm, complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated Stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, two core cable flat or circular of 16 Sqmm complete all as specified and directed . .
M & L for point wiring with two runs of single core 1.5 Sqmm FRLS (confirming to IS-694) PVC insulated unsheathed 1100 Volts grade multi stranded copper conductor with one single core 1.50 Sqmm FRLSH PVC insulated unsheathed stranded copper conductor as earth continuity conductor drawn through in and including PVC casing caping (ISI Marked) of required size (25x12/32x12mm) along with all fitting/ fixtures such as Tee, Bend, Elbow socket, Saddles etc. and making good the disturbed surface and connecting to common earth dolly complete with 3 mm thick PVC rectangle block of suitable size fixed over wall by grouting screws for accommodating switches sockets for One light point controlled by two Nos two way switch.Note (i) Colour of cables as Phase-R/Y/B, Neutral-Black and Earth-Green. (ii) Switches and sockets to be measured and paid separately under relevant items
S&F switch piano flush type, 5 Amps, Single pole, two way, 240 volts complete all as specified and directed
S&F surface mounting batten type, slim LED luminaires 18 W, 230 V, AC with polycarbonate round shape diffuser, grey designed end caps with fliker control technology to reduce harmful invisible flicker present in LED lighting sources, minimum efficency 100 lm/watt with 120 degree viewing angle CCT 6500 CRI > 80, rated voltage 240v AC power factor > 0.9, IP 20, surge protection 2.5 KV integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete and fixing of this luminaires on the wall by stainless steel screw rewl plug etc and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit complete all as specified and directed.
Labour for fixing of serviceable single phase electronic meter of any capacity and any make for controlling of stair case light fittings with and including 3mm thick plastic laminated sheet cover of size 250x200x50 mm deep by grouting 04 Nos screws on wall complete with and including elecrical connection complete all as specified and directed . Note : Meter will be issued from MES store Yard.
Excavation in trenches not exeeading 1.5m wide and not exceeding 1.5m depth/width and getting out loose/soft soil for laying of under ground cable complete all as specified and directed.
Returning/ filling including spreading, levelling and well ramming in layers not exc 25cm in thick complete all as specified and directed .
Removal of surplus soil to a distance not exc 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed .
Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and directed by Engr in charge. Note:- Only punned thickness of 18cm will be measured for the purpose of payment.
Supply and lay burnt brick of size 230x115x75mm for protection of cable, laying in trenches completeall as specified and directed by Engr in charge.
Laying only serviceable burnt brick of any size and any make obtained from item No 28 for protection of cable, laying in trenches completeall as specified and directed by Engr in charge.
Relaying of old LT cable XLPE insulated with aluminium conductor of size from 10 to 25 sqmm, 2/3.5/4 core, 1100 volts grade complete all as directed by Engineer-in-Charge. Note : - (i) Seviceable LT cable obatined from ser item No.35 shall be used.
Taking out / down unserviceable 1.1KV, LT UG cable from existing trenches/duct/ Poles of any cross sectional area including disconnecting, bricks, GI Pipe etc. of any descriptions, segregation of serviceable materials viz brick cover, GI Pipes, UG cables etc. and tracing the location of fault and keeping in safe custody for re-use complete all as directed NOTE : (i) Earth work shall be measured and paid for separately under relevent items. (ii) Serviceable cable covers, cables and GI pipes shall be kept aside for re-use.
Supply and Laying LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 10 Sqmm 2 core aluminium conductor in trenches/poles and connecting with all accessories lugs & glands complete.
All as per item No.38 above but of cable 16 Sqmm 2 Core complete all as specified and directed.
S&F MCCB, 4 Pole, 415 Volts including connection and testing , breaking capacity 25 KA of rating 63 Amps in replacement complete all as specified and directed .
S&F MCCB, 4 Pole, 415 Volts including connection and testing , breaking capacity 25 KA of rating 100 Amps in replacement complete all as specified and directed.
S&F MCCB, 4 Pole, 415 Volts including connection and testing , breaking capacity 25 KA of rating 125 Amps in replacement complete all as specified and directed .
S&F GI tubing of 50mm dia light grade at road cross for protection cable as per site requirement and sealing the pipe both ends with sealing compound complete including taking down old one complete.
M&L for boring of hole under road, pavement hard standing by trenchless technology using ultra sounding techinque and necessary machine of dia 80 mm complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron steel wire 4mm dia as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate no-4 of SSR part No1 all as directed.
SCHEDULE 'A'/BOQ OF 19 WING
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) including fittings, such as switches, ceiling roses, pandents, regulators, sockets, etc., removing materials to store for keeping in safe custody for re-use at site and making good to disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down old unserviceable Empty Box / Bus Bar Chamber / DB’s of any capacity with MCCB's or MCB fixed on wall and making good disturbed surfaces of wall / floor with cement plaster in cement mortar (1:6) and distempering / white washing to match the existing surface complete all as specified & directed.
M&L for refixing of FTL, PL, CFL, LED luminaires (serviceable fixtures retreived from item no. 47) after cleaning the old luminaires by mild cleanser and making good disturbed surfaces of wall /ceiling with cement plaster in cement mortar (1:6) and distempering / white washing to match the existing surface complete all as specified & directed. Note:- Replacement of connecting cable is deemed to be included in this rate.
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 1.5 Sqmm 1100 volts grade with one single core PVC insulated unsheathed multistranded copper cable(FRLSH) of size 1.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code), drawn through in and including PVC concealed conduit (medium grade)of size 25 mm with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and connected to common earth dolly, sunk type metal box for housing / mounting the modular switch sockets with mounting plate / cover plate complete all as specified and directed for the following items :-
One light point controlled by one no one way 6 Amps switch complete.
One fan point controlled by one no one way 6 Amps switch complete
One calling bell point controlled by one no 5 Amps bell push switch complete
One 6 Amps switch socket combination point on independent board complet
All as per Serial item No. 50 here-in-before but for power point wiring with 2.5 sq.mm FRLS PVC insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 sq.mm FRLS PVC insulated, unsheathed, copper conductor, stranded 1100 volt grade cable for earth continuity.
S&F modular switch single pole one way, 6 Amp, AC,230 V all as specified and directed.
S&F modular bell push, 6 Amp, AC,230 V all as specified and directed.
S&F modular switch single pole one way, 16 Amp, AC,230 V all as specified and directed.
S&F modular socket 6A, AC, 230V complete all as specified and directed.
S&F modular socket 6 /16 Amp, AC, 230V complete all as specified and directed.
S&F rotary step modular electronic fan regulator (2module) flush type AC, 230V complete all as specified & directed.
S&F Calling Bell Ding Dong Type AC, 230V complete all as specified and directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 2.5 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 2.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed. Make-PVC Cable-RR Kable/ Finolex/ Havells DLP mini trunking-Legrand
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 2.5 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 2.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including PVC concealed conduit (medium grade) of size 25 mm with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and complete incl. taking down old one all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including PVC concealed conduit (medium grade) of size 25 mm with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and complete incl. taking down old one all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including PVC concealed conduit (medium grade) of size 25 mm with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and complete incl. taking down old one all as specified & directed.
S&F sheet metal enclosure for DB’s TPN Double Door 8 way, AC, 415 volt, IP 43 on the wall with MCCB, 160A, 4Pole of breaking capacity 16kA as incomer complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s TPN Double Door 4 way, AC, 415 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s Vertical-TPN Double Door 12 way, AC, 415 volt, IP 43 on the wall with MCCB, 125 A, 4Pole of breaking capacity 25kA as incomer by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface incl connection of cable, testing checking etc complete all as specified & directed. Make-ABB/ Legrand/ Siemens/ L&T Note:- MCCB and MCB will be measured and paid separately.
S&F sheet metal enclosure for DB’s SPN Double Door 12 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s SPN Double Door 8 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed
S&F sheet metal enclosure for DB’s SPN Double Door 4 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s for Plug & Socket, SP, AC, 240 volt with MCB SP 16 A on the wall complete by cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed
S&F MCB TPN 40 to 63 Amps, Type ‘C’ Characteristic 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed.
S&F MCCB, 4P, 100 -125 Amps,Type ‘C’ Characteristic 415 Volts 50 HZ, 36 KA, Ics= 50% Icu incl. connection of cable testing, checking etc complete all as specified & directed.
S&F MCB SP 6 to 20 Amps,Type ‘C’ Characteristic 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed.
Refixing of MCB SP 6 to 20 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed.
S&F MCB SPN 20 to 32 AmpsType ‘C’ Characteristic 240 Volts, 50 Hz, 10 KA breaking capacity complete all as specified & directed.
Supply of surface mounted batten type, slim LED luminaires 10W, 230V AC with polycarbonate housing and diffuser, minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of surface mounted batten type, slim LED luminaires 18W, 230V AC with polycarbonate round shape diffuser, grey designed end caps with flicker control technology to reduce harmful invisible flicker present in LED lighting sources, minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Fixing of surface mounted batten type LED luminaires (10 or 18W, 230V AC) (as mentioned in sl 30 & 31) on the wall by stainless steel screw, rawl plug etc. & connecting up to ceiling rose with three core sheathed copper conductor cable (white/ gray colour) of suitable sizes complete incl taking down old unsv one all as specified and directed.
Supply of recess mounted back-lit LED luminaires 36W, 230V AC, 2X2 tile in CRCA housing with full opal diffuser with flicker control technology to reduce harmful invisible flicker present in LED lighting sources, CCT 6500, CRI ≥ 80, rated voltage 240V AC, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed. Make- Orient AQUA RECESS 2X2 FC - LTRAQ -36 -C -FC/ Philips/ Havells
Supply of surface mounted back-lit LED luminaires 36W, 230V AC, 2X2 tile in CRCA housing with full opal diffuser with flicker control technology to reduce harmful invisible flicker present in LED lighting sources, CCT 6500, CRI ≥ 80, rated voltage 240V AC, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Fixing of recess or surface mounted batten type LED luminaires (36W, 230V AC) (as mentioned in sl 83 & 85) on the wall by stainless steel screw, rawl plug etc. & connecting up to ceiling rose with three core sheathed copper conductor cable (white/ gray colour) of suitable sizes complete incl taking down old unsv one all as specified and directed. NOTE:- i) For maintenance works of sl no 63 to 80 and 83 & 85, contractor should provide minimum one electrician and one helper in every working day. ii) The site location for above items are scattered, hence contractors should survey the exact accn before quotating the rate.
M&L for re-assembling or re-laying of existing sub main wiring of any cable type or sizes through in and including DLP U PVC trunking of 50X80 mm size incl. all finishing accessories such as angles, end caps, covers etc on roof /wall /ceiling etc complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete incl taking down old damage casing caping all as specified and directed by Engr-in-charge. Make-PVC Trunking- Legrand PVC Cable- Finolex/ Plaza/ Havells Note:- i) No PVC flexible conduit should be allowed in the wiring. ii) Any PVC cable required for re-assembling or re-laying of sumain wiring is deemed to be included in this rate, however in no more circumstances the length of cable of each size or type is not more than 5 RM iii) Items such as rawl plug, steel screw etc reqd for fixing DLP U PVC trunking is deemed to be included in this rate.
S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals (ISI Marked), AC, 230 Volts on PVC box complete incl taking down old unsv/ broken one all as specified & directed.
M&L re-assembling or re-laying of wiring cable through in and including PVC casing caping of exising sizes and types incl. all finishing accessories on roof /wall /ceiling etc complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete incl taking down old damaged one all as specified and directed by Engr-in-charge.
ANZ CORPORATION
MOINUL HOQUE CHOUDHURY
B S ENTERPRISE
M/s Rawat Enterprises
Baruah Fabrication
Purbanchal Construction Co
M/s B.M. Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .