| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC 107 1A TOLLYGAUNG ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹53.8 L+₹4.6 L (9.37%)Rejected-Finance 8 27 BEJOYGARH JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹55.0 L+₹5.7 L (11.7%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹55.8 L+₹6.6 L (13.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹55.9 L+₹6.7 L (13.6%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹44.6 L
EMD Value
₹89,200
Closing Date
22 Sept 2023, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
ADDN/ ALTN OF TOILET AND BATHROOMS OF ALL FLOOR AT BLDG NO P-136 AT 561 SUB GP (ASCON) AND PROVN OF 8 LAYER BITUMINOUS SYNTHETIC FLOORING ON COURT NO 2 AND PAINT OF POLES AND METAL MESH AROUND LAWN TENNIS COURT HQ EASTERN COMD UNDER GE (FW) KOLKATA
2023_MES_615474_1
8166/E8
Open Tender
Civil Works
Item Rate
120 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹89,200
16 Nov 2023
24 Aug 2023
23 Sept 2023
24 Aug 2023
22 Sept 2023
8 Sept 2023
Amount
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 150 mm thickness (above or below ground level) including removal of debris & rubbish from site complete all as specified and directed.
Demolition Cement Concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
M&L Brick Work with fly-ash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L for rendering 15 mm thick built in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even & smooth (without using extra cement) and mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE : Water proofing compound shall be measured and paid separately).
Supply only liquid water proofing compound all as specified and as directed.
M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished rendering surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick cement plaster on ceiling surfaces finishing even and smooth without using extra cement in cement mortar (1:3) including necessary scaffolding complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls and applying two coats of cement base paint over a coat of alkali resistant primer with brush, complete all as specified and as directed.
M&L Preparing new plastered surfaces of Wall and applying two Coats of acrylic bound distemper over one coat of alkali resistant primer with roller, over 1mm to 2mm thick plaster of paries, complete all as specified and as directed.
M&L Preparing new plastered surfaces of ceilings and applying two Coats of acrylic bound distemper over one coat of alkali resistant primer with roller, complete all as specified and as directed.
M&L 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection, finished even and smooth without using extra cement as directed by the Engr-in-Charge.
M&L 100 mm thick PCC (1:2:4) type B-2 (using 40mm graded crushed stone aggregate) as in flooring/hardstandings, finished even and fair without using extra cement, complete all as specified and directed by the Engr-in-Charge.
M&L for 40 mm thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in flooring, finished even and fair without using extra cement, complete all as specified and directed by the Engr-in-Charge.
M&L 25 mm thick PCC (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base flooring, finished even and fair without using extra cement, complete all as specified and directed by the Engr-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles, laid over and including screed bed 15mm thick in cement mortar 1:6 complete all as specified and directed.
M&Lfor non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular) area of each tile not exceeding 0.11 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles, laid over and including screed bed 15mm thick in cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350 x 250 x 7mm / 450 x 300 x 7 mm thick as on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match the colour of tiles, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L for Machine cut Coloured granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, urinal partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and making moulds on edges laid over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and directed.
Supply and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. (NOTE: Cost of sand cushioning is deemed to be included in the quoted rates)
M&L for pre-polished Chequered cement concrete tiles (coloured) of size 40cmx40cmx25mm thick , set , jointed and pointed in neat cement slurry in floor and pointed with white/coloured cement & pigment to match the surface laid over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Taking down chowkats of frames with shutters (without taking off shutters, from the frames) not exceeding 1.50 Sqm each and removing off the site complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed.
M&L for 2nd class hardwood, plain soild, straight chowkhats and frames, wrought, framed rebated on the soild, rounded or chamfered, put together, with glue, pinned at joints complete all as specified and directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter(two panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F Factory made solid PVC door frame (chowkhat) of size 50 mm x 47mm made out of 5mm plain colour PVC sheet, frame reinforced with MS square tube, fixed in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F 5.5mm thick sheet glass, ordinary quality, glazing with cleats, glazing clips, rubber neoprene packing etc, in squares exceeding 0.5 sqm in each pane complete all as specified and directed.
All as per item No.31 above but glass frosted on one side complete
M&L solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, all as specified and directed.
S&F Aluminium anodised Powder coated for doors, windows, ventilators and partition with one or more rebate (minimum thickness of powder coating 50 micron) and three track with 1.8 mm thick channel section and shutter frame thickness 1.65mm, without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. Notes: 1) Size of window shall be as per site requirement. 2) Glass and wire cloth shall be measured separately.
S&F Anodised aluminium grill ( anodised transparent or dyed to required to IS: 1868 with minimum anodic of coating of grade AC15) of approved design /pattern with approved slandered section and fixed to the existing window frame with C.P proper opening size for fixing and operation of handles and fixing proper opening size for fixing and operations of handles and fixing approved aluminium slandered section around the opening all complete as all as per requirement and direction of engineer in charge.
S&F stainless steel wire cloth of 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Butt Hinges medium weight cold rolled stainless steel 75mm long complete all as specified.
S&F Butt Hinges medium weight cold rolled stainless steel 100mm long complete all as specified.
S&F aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specified and as directed.
S&F Aluminium anodised bow handle fabricated type extruded section of 150mm long complete all as directed
S&F Aluminium anodised bow handle fabricated type extruded section of 125mm long complete all as directed
S&F Aluminium anodised sliding door bolts of 300mm long with hasp and staple(bolt type) and fixing clips of sheets ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking up or down GI Steel Water Tubing including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed for the following size of pipes :-
15mm bore outer dia
20mm bore outer dia
25mm bore outer dia
Supply, Laying and testing Steel Water Tubing, Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and directed for the following size of pipes :-
15mm bore outer dia
20mm bore outer dia
25mm bore outer dia
Relaying/Re-fixing Galvanised Steel Tubing and Connections in New or Old Position (Serviceable Pipes and Fittings obtained from taking down item) after Cleaning both Inner and Outer Surfaces of Pipes by using of Wire Brush, fixed to walls and ceilings or laid in floors complete all as specified and as directed for the following size of pipes :-
15mm bore outer dia
20mm bore outer dia
S&F Gun metal gate valve as per IS : 778-84 Class-1 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions as in repairs, complete as all specified and as directed for the following size of pipes :-
15 mm bore
20 mm bore
S&F Vitreous China Wash Hand Basin 550mm x 400mm in size, white, Flat Back or Angle Back Type, making good disturbed Surfaces in Cement Mortar 1:3, providing CP waste coupling and PVC waste pipe and connected Items, complete all as specified and directed. (Make of WHB : PARRYWARE, Model: FLAIR / HINDWARE, Model: MARIO / JAQUAR, Model: CONTINENTAL / CERA, Model: CLAIR/ASIAN PAINTS, Model: SIRIUS) (NOTE: Quoted rate shall be deemed to be inclusive of the cost of brackets, waste coupling and waste pipe)
S&F in repair Vitreous china, white, full stall urinal flat back with grating and union for discharge pipe (excl flush pipe and flushing cistern and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and Union for discharge pipe complete all as specified and directed. (Make of Urinal : CERA, Model: CAPRIANA / HINDWARE, Model: FLAT BACK LARGE / Jaquar, Cat No: URS-WHT-13261/PARRYWARE, Model: New Magnum)
S&F in repair vitreous China Squatting pan ‘Orissa’ pattern, size 580 X 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc and including making good to floor, complete all as specified and directed. (MAKE : CERA, Cat No: S3010109 / HINDWARE, Cat No. 20042 / PARRYWARE, Cat No: C0126)
S&F in repair 10 ltrs capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and incl with flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed. (MAKE : PARRYWARE, Model : Slim line Economy / HINDWARE, Model : Sleek Plus / CERA, Model : Corona / PRAYAG, Model: SMART /ESSCO, Cat No: WHE-WHT-183NL)
S&F 600mm x 450 mm mirror with PVC frame and fixed to wooden plugs with chromium plated brass screw and cup washers, as in repairs, complete all as specified and directed. (Make: PRAYAG, Cat No: 553 or equivalent model in other makes specified in CA)
S&F in repair Chromium plated brass Wall mixer, concealed type, with concealed body, with overhead shower arrangement fixed with 15 mm bore Iron pipe including taking down existing mixer complete all as specified and directed. (Make : JAQUAR, Cat No : FUS-29273UPR / PARRYWARE, Cat No: G4816A1 / CERA, Cat No: F1003401 / PRAYAG, Cat No: 9375-N / HINDWARE, Cat No: F390020)
S&F Chromium plated brass Pillar tap, fancy type. with aerator, fixed to wash hand basin, complete all as specified and directed. (Make : Ess Ess, Cat No: C-201B / JAQUAR, Cat No: CON-021KN/ PARRYWARE, Cat No: G1402A1 / PRAYAG, Cat No: 9204/ HINDWARE, Cat No: F330002CP / Cera, Model: OCEAN)
S&F Chromium plated brass Bib cock with wall flange, fancy type, fixed to 15 mm bore of Iron pipe, as in repairs, complete all as specified and directed. (Make : Ess Ess, Cat No: RB-103 / PRAYAG, Cat No: 6706 / Essco, Cat No: SQT-512KN / / /SOMANY, Model: ETHER)
S&F in repair chromium plated brass over head shower rose with arm (premium range), with 3 flow, fixed to 15mm bore of iron pipe including taking down existing shower complete all as specified and directed. (Make : CERA, Cat No: F7040103 (for arm) & F7020305 (for shower) / PARRYWARE, Cat No: T9802A1 (for arm) & T9986A1 (for shower)/ HINDWARE, Cat No: F160051)
S&F 15 mm bore fancy type stop valves, cast copper alloy, chromium plated (concealed type), screwed down, high pressure, with crutch or butterfly handle, incl concealed body, screwed both ends for iron pipe or for unions and, complete all as specified and directed. (MAKE : JAQUAR, Cat No: FLR-5083NK & ALD-083 /ESS ESS, Cat No: TM-332 & E221 / CERA, Model: F200351 & F4050102 / PARRYWARE, Cat No : G0651A1 & G5052A1 / PRAYAG, Cat No: 9318 & CPS-15/ HINDWARE, Cat No: F280027 & F850096)
S&F Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: KUP-35053PM / PARRYWARE, Cat No: T3097A1 / CERA, Cat No: F1005201 / PRAYAG, Cat No: 9410 / HINDWARE, Cat No: 320006 )
S&F Tubular towel rail (normal range), 20mm dia, 600 mm long between flanges including brass chromium plated, as in repairs, complete all as specified and directed. (MAKE : Essco, Cat No : AEC-1111 / PRAYAG, CAT No: BA-40 / ESS ESS, Cat No : AC-701 / SOMANY, Model: ETHER)
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed by Engineer-in-Charge.
S&F Grating doom 125mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed by Engineer-in-Charge.
S&F Low density polyethylene pipe connection, comprising of 15 mm dia 450 mm long having PTMT union at each end, as in repairs, complete all as specified and directed. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 / ESS ESS, Cat No: B2CH118 or equivalent model in SHAKTI / JEXON)
S&F in repair chromium plated brass waste coupling, 32 mm size, full threaded complete all as specified and directed. (Make: PRAYAG, Cat No: BEA-11 / JAQUAR. Cat No: ALD-705/ CERA, Cat No: F8050101 /PARRYWARE, Cat No: T9911A1 / HINDWARE, Cat No: F850002)
S&F in repair chromium plated brass waste coupling, 40 mm size, full threaded complete all as specified and directed. (Make: PRAYAG / JAQUAR/ CERA /PARRYWARE / HINDWARE)
S&F in repair 15mm bore chromium plated single lever central hole basin mixer (premium range) without popup waste system with 450mm long copper pipe and brass nut, complete all as specified and directed. (MAKE : JAQUAR, Cat No: ARI-39001B / CERA, Cat No : F1005451 / ASIAN PAINT, Cat No: MYBM101 / HINDWARE, Cat No: F360011/ PRAYAG, Cat No: 8151 /PARRYWARE, Cat No: T3814A1)
S&F in repair CP bottle trap with internal portion 32mm size with 190mm long wall connection pipe complete all as specified and directed (Make: JAQUAR, Cat No: ALD-769L250x190 / ESS ESS, Cat No: C-231C / HINDWARE, Cat No: F850003 / CERA, Cat No: F8060302/ PRAYAG, cat No: BEA-26)
S&F 20 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-152 or equivalent model in JEXON / POLYTUF / SHAKTI)
M&L for PTMT Symphonic assembly for low level flushing cistern of 10 litre capacity fixed in repairs, complete all as specified and directed.
Supply and fixing 110mm bore PVC (SWR) pipes, single socketed, in any length, with rubber ring joints, laid in trenches / fixed to wall all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 75mm bore PVC (SWR) pipes, single socketed, in any length, with rubber ring joints, laid in trenches / fixed to wall all as specified and as directed by the Engineer-in-Charge.
Supply and Fixing 110 mm PVC (SWR) junction single (single T) equal or unequal, complete all as specified and as directed by the Engineer-in-charge.
Supply and Fixing 75 mm PVC (SWR) junction single (single T) equal or unequal, complete all as specified and as directed by the Engineer-in-charge.
Supply and Fixing 110 mm PVC (SWR) Bend any radius complete all as specified and as directed by the Engineer-in-charge.
Supply and Fixing 75 mm PVC (SWR) Bend any radius complete all as specified and as directed by the Engineer-in-charge.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris out of MD land, complete all as specified and as directed.
M&L for brushing neat cement slurry with 2.75 Kg of cement per Sqm on roof complete all as specified and directed.
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as specified and directed.
M&L bituminous gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces, all as specified and directed.
M&L for Providing Cement Concrete, 25 mm thick, type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding mixed with water proofing compound and the concrete surfaces is to be finished even and fair (without using extra cement) complete all as directed by Engineer - in - charge . (NOTE: WPC Shall be measured & paid separately)
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane. (v) Sealing of all angles & abutments up stands with extra care to ensure perfect bondage. Sealing of edges well into grooves & protect the seal with a polysulphide/polyurethane sealant.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs, beams, columns, lintel, chajja, fins, facia etc. of 50 mm average thickness (Any storey / height of building/ structure) including tapering all edges, making square shoulders of cavities by air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting including removal of foreign materials, loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed by Engr-in-Charge.
Deduct / Add for below / over 5mm or part thereof thickness for item No. 83.00 above (Any storey/ height of building/ structure)
Removing of concrete all around reinforcement bar up to 12 mm dia from behind the reinforcing bars average 25mm (but not less than 15mm) air gap by manual methods (using wire brushing , chiselling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by emery paper and cleaning the area thoroughly by water and allow it to dry and making the reinforcement bar totally rust free (for any storey/ height of building/ structure) complete all as specified and directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product in SIKA / PIDILITE / BASF / CHOKSEY) (NOTE: Surface area of cleaned steel reinforcement shall be measured for payment)
Removing of concrete all around reinforcement bar above 12 mm dia from behind the reinforcing bars average 25mm (but not less than 15mm) air gap by manual methods (using wire brushing , chiselling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by emery paper and cleaning the area thoroughly by water and allow it to dry and making the reinforcement bar totally rust free (for any storey/ height of building/ structure) complete all as specified and directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product in SIKA / PIDILITE / BASF / CHOKSEY) (NOTE: Surface area of cleaned steel reinforcement shall be measured for payment)
M&L for applying a coat of epoxy bonding agent on existing concrete surfaces, with mixed density 1.48 Kg/litre and adhesive bond strength>2.50 MPs, mixed and applied as per manufacturer's specifications complete all as specified and directed. (Make- Nito bond EP of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
Material, labour and preparation of existing reinforcement surface (at any storey/ height of building/ structure) by brush and application of two component epoxy zinc rich primer of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre on existing reinforcement surface complete all as specified and directed. Make- Nito zinc primer of FOSROC or equivalent product in SIKA / PIDILITE / BASF / CHOKSEY)
M&L for introducing new mild steel TMT reinforcement bars upto 12 mm dia for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Quoted rate is deemed to be inclusive of the cost of reinforcement bars)
M&L for introducing new mild steel TMT reinforcement bars above 12 mm dia for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Quoted rate is deemed to be inclusive of the cost of reinforcement bars)
Material , labour and placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days, 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 60mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction complete all as specified and as directed. (Make of micro concrete:- Renderoc RG of FOSROC or equivalent product in SIKA / PIDILITE / BASF / CHOKSEY)
Material , labour and placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days, 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 50mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction complete all as specified and as directed.. (Make of micro concrete:- Renderoc RG of FOSROC or equivalent product in SIKA / PIDILITE / BASF / CHOKSEY)
Deduct / Add for below / over 5mm or part there of thickness for item No 92.00 above, complete all as directed.
M&L for treatment of existing wall surface with tartaric acid or oxalic acid to remove all the existing salt from the surface then rinsing the entire wall/slab surface and applying 15 mm thick two component structural grade polymer modified reinstatement mortar of compressive strength, flexural strength shall not be less than 45 MPa at 28 days, 7 MPa at 28 days respectively (maximum coverage area 1.30 sqm per 25 kg pack @ 10mm thickness) over a coat of epoxy bonding agent on existing surface for strengthening of beams, columns and other structural element of average thickness 25 mm and mortar shall be applied in layer not exc 6 mm thick in layers and including surface preparation as per manufacturer's instructions complete all as specified and directed (any storey/height of building/structure). (Make- Rendroc S2 (for mortar) & Nito bond EP (for bonding agent) of FOSROC or equivalent product in other makes specified in tender)
Material, labour and applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction (for any storey/ height of building/ structure) complete all as specified and as directed. (Make:- Concure LP90 of FOSROC or equivalent product in SIKA / PIDILITE / BASF / CHOKSEY)
M&L for applying cementitious grouting by mixing admixture with cement slurry at a dosage of 225 ml per bag of cement and injecting with high pressure by a pressure grouting pump through non-return PVC nozzles prefix with rapid setting cementitious plugging mortar to fill all possible pores and gaps left within the old concrete mass of buildings of any storey/height. Pumping shall be stopped only when the flow of grout stops or shows refusal or grout flows out from adjacent nozzle and the nozzle shall be tied up and allowed to set for 24 hours. The PVC nozzles shall be sealed off with quick setting cementitious plugging mortar. Grouting operation shall be carried out through next nozzle till the entire area is covered. The grouting holes shall be finished by removing the protruded portion of nozzles and finishing flush with the surface complete as per manufacturer's instructions & as directed by Engr-in-Charge. (Make of Grouting Admixture:- Cebex 100 of FOSROC or equivalent product other makes specified in tender) (NOTE: The work shall be got executed through authorised applicator of the chemical manufacturers. Necessary documents to this effect shall be obtained from manufacturer and submitted to the Engineer-in-Charge. Contractor shall provide additional manpower, resources, preparatory work etc. required for execution of the work as required by the authorised applicator. Quoted rates are deemed to be inclusive of the above aspects. No extra claim shall be admissible during execution of work on this account).
M&L for applying two coats of elastomeric and protective anti-carbonation coating, on concrete/masonry surfaces over a coat of silane-siloxane primer as per manufacturer's instructions, complete all as specified and directed. (Make- Dekguard E2000 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for grouting of voids/cracks with high strength epoxy resin grout as per manufacturers instructions complete all as specified and directed. (Make- Conbexta EP 10 of FOSROC or equivalent product in other makes specified in tender) (NOTE: The item shall be executed if any voids/cracks are found during execution/removing of concrete mortar from the surface).
Supply and laying of eight layer synthetic lawn tennis court as per manufacturer's specifications as per following sequence :- (a) Filler Course :- Providing and laying one coat of acrylic resurface blend with approved silica sand. (b) Texture Course :- Providing and laying 1 coat of synthetic acrylic colour blend with silica sand for uniform surface texture for determining the speed of play and traction of the court. (c) Finish Course :- Providing and laying 1 coat of synthetic acrylic colour blend with silica sand for uniform surface texture and vibrant, durable finish highly resistant to weather and ultraviolet degradation. (d) Line Marking :- Providing and laying heavy bodied acrylic latex white striping paint for complete court as per site requirement. (MAKE: BAXTER INTERNATIONAL / COSTA SPORTS SYSTEM PVT LTD / REBOUND ACE INDIA PVT LTD / SUNDEK SPORTS SYSTEM) (NOTE: The work shall be got carried out by authorised workmen/ applicator of the manufacturer)
Dismantling posts or struts (wood, steel or RCC), any section, embedded in natural ground, including taking out embedded portion and making good disturbed ground, complete all as directed.
Dismantling posts or struts (wood, steel or RCC), any section, embedded in concrete, brick work, masonry etc., including taking out embedded portion and making good disturbed ground, complete all as directed.
Dismantling of old chain link wire mesh fencing including flat iron, mild steel round supporting bars, bracing bar etc., complete all as specified and directed.
Excavating in post hole (or similar hole) each n exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 M and making good surface in soft and loose soil complete all as specified and as directed.
M&L for hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L PCC 1:3:6 type C2 (Using 40 mm graded stone aggregate) in Foundation, filling and mass concrete, complete all as specified and as directed.
M&L Mild steel framed work such as grills of ornamental type, gratings, etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works incl portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc confirming to grade Fe-290. Gde-E-165 complete all as specified and directed.
S&F MS angle, flats, etc independently fixed without connecting plates etc but ordinary length conforming to FE-410-W(Gde-E-250)quality A as in fencing posts including drilling holes for nuts and bolts and similar work complete all as specified and as directed.
Re-fixing of RCC post or angle iron post complete all as specified and as directed.
M&L Mild Steel Screw Bolts (machine made) 5mm to 10mm diameter of neck and length of bolt exc 5 Cm and not exc. 10 Cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed.
S&F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape required, complete all as specified and as directed
S&F 4mm dia PVC coated galvanised mild steel chain link fencing of mesh size 50x50mm fixed with straining bolts including line wire any mesh size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and as directed.
Re-fixing of old serviceable chain link fencing (Chain link fencing obtained from item No.102 here in before) including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
M&L Preparing old Steel Surfaces of any description not otherwise described over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint, complete all as specified and as directed.
S&F RCPC (Reinforced Cement Polymer Concrete) grating slab of size 600 mm x 450 mm x 75 mm thick, of Capacity 3 MT fixed in proper position complete as directed by Engr-in -Charge.
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc excluding light fitting for reuse or removing from site and making good disturbed surface of walls, floors etc. Complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured separately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No.117 here-in-before, but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No.117 here-in-before, but for one 5 pin 5/6 amps multi-socket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No.117 above, but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuity wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
S & F Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S & F Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S & F Modular Socket 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Blank plate, 1 module complete all as specified and directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 4 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate diffuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
M&L for sub main wiring with two run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm as earth continuity conductor drawn through and including concealed PVC conduit of suitable size, surface type complete all as specified and directed. (NOTE : Three runs of single core 4.0 Sqmm cable & one run of PVC conduit shall be measured as one unit)
S&F SPN DB, IP 43 protection, double door (premium range), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T / LEGRAND / ABB / SCHNEIDER / HAGER/ PANASONIC/ C&S )
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / ABB / SCHNEIDER / HAGER/ PANASONIC/ C&S )
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / ABB / SCHNEIDER / HAGER/ PANASONIC/ C&S )
Supply, installation, testing and commissioning of heater water storage type electric geyser (vertical cylindrical type) 25 ltrs capacity with BEE 5 star rating (min) and ABS body, glass lined/titanium enamel coated inner tank incl fixing arrangement with providing incl suitable capacity flexible cable 3 core with 3 pin plug of 16 amp and 02 Nos chromium plated brass connector pipe 15mm dia, 600 m long with brass coupling and union at both ends complete all as specified and directed. (Make: RACOLD, Model - CDR DLX / AO SMITH, Model- HSE-VAS / Havells, Model: Monza Dx / BAJAJ, Model: CALDIA)
S&F ventilating fan 250 mm sweep, with louvre shutter and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose to fan complete all as specified and directed. (MAKE : HAVELLS, Model : Venti Air DX / CROMPTON, Model : Brisk Air / HALONIX, Model: HELION DX / USHA, Model: CRISP AIR or equivalent model in BAJAJ / ORIENT)
MAZUMDER ENTERPRISE
PRABIR TRADERS
PINKY CO.
M A ENTERPRISES
SHEIKH ENTERPRISE
dutta and dutta
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .