Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹22.1 L+₹60,932 (2.83%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹24.5 L+₹3.0 L (14.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹27.4 L+₹5.9 L (27.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
25 Apr 2022, 6:00 pmClosed
CWE JAIPUR
HQ CWE Jaipur, Kalyan Marg, Jaipur
REPAIR AND MAINT OF EARTHING, DUCTING, COOLING TOWERS, COMPRESSORS AND CONNECTED ITEMS AND OTHER REPAIR WORKS OF CENTRAL AC PLANT AT MH AND SSA UNDER GE JAIPUR
2022_MES_515444_1
CWE/JPR/82139/E8
Open Tender
Miscellaneous Works
Item Rate
365 days
GE Jaipur
enlisted with MES in Class D and above and category b(i) or c(i)
7 documents required · 7 mandatory
₹500
Yes
GE Jaipur
₹64,000
Yes
6 Jul 2022
26 Mar 2022
27 Apr 2022
26 Mar 2022
25 Apr 2022
11 Apr 2022
Amount
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 600 mmx600mmx6mm, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. NOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.50 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire. (iii) Quoted shall include cost of 7.5 metre earth lead wire. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Supply only electrical insulating mat made of elastomeric polymers of size 1.0 m x 2.0 m x 2.0 mm, class 'A' in blue colour confirming to IS : 15652 of 2006 as approved etc. complete all as specified and directed.
Supply & laying in replacement LT cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade ISI marked, laid in trenches/under road/floor or on wall complete all as specified and directed of following size of cable:-
(a) 240 Sqmm, 3.5 core cable
(b) 185 Sqmm, 3.5 core cable
(c) 120 Sqmm, 3.5 core cable
(d) 35 Sqmm, 4 core cable
M&L for dismantling of old ducting of any type and shape including all accessories viz. Corner, Cleat, Carriage bolt, Gasket etc. complete all as specified and directed.
Supply , assembly and erection of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 24 Gauge etc. and including providing duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation with including following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr. (d) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium fol tape 50 m wide to make the insulation leak proof. complete all as specified and directed.
S&F in repair MCCB 400A, TP,415V, 50 Hz, 36KA adjustable type of make L&T or equivalent etc. complete all as specified and directed.
S&F in repair MCCB 250A, TP, 415V, 50 Hz 36KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed.
S&F in repair MCCB 160A, TP,415V, 50 Hz 36KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed.
M&L for Painting of 80TR central air conditioning plant equipments comprises of Chiller, Compressor, Motors, Pumps, LT Panel refrigerant/water suction line, discharge lines of any specification with synthetic enamel paint of approved quality after preprations of surface including conceled fitments e.g., condenser, chiller, valves etc as per IS colour code of Central air conditioning plants including writing MES / SM No etc. complete all as specified and directed.
M&L for Cleaning of condenser of 80 TR Central AC plant by suitable chemical circulation and brushing of condenser tubes as required etc. complete all as specified and directed.
M&L for Servicing of AHU's cleaning cooling coils by non acidic chemical, cleaning of filters by suitable tools as required etc. complete all as specified and directed.
M&L for renewal of unserviceable mechanical oil seal of compressor at coupling end including testing and commissioning etc. complete all as specified and directed. Note:-Gas/Oil required to be changed after renewal of mechanical oil seal will be measured and paid separately in respective items of BOQ.
M&L for Dismantling, opening, rewinding and refixing of, 3 phase, 440V, 50 Hz induction motors capacity 3 to 7.5 HP with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechanical works for shaft/bearing housing , renewal of DE and NDE bearings, transportation from installation to workshop & back including connecting testing and commissioning at site for satisfactorily operation as required etc. complete all as specified and directed.
M&L for Dismantling, opening, rewinding and refixing of, 3 phase, 440V, 50 Hz induction motors capacity 10 HP with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechanical works for shaft/bearing housing , renewal of DE and NDE bearings, transportation from installation to workshop & back including connecting testing and commissioning at site for satisfactorily operation as required etc. complete all as specified and directed.
M&L for Dismantling, opening, rewinding and refixing of, 3 phase, 440V, 50 Hz induction motors capacity 12.5 to 20 HP with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechanical works for shaft/bearing housing , renewal of DE and NDE bearings, transportation from installation to workshop & back including connecting testing and commissioning at site for satisfactorily operation as required etc. complete all as specified and directed.
M&L for Dismantling, opening, rewinding and refixing of, 3 phase, 440V, 50 Hz induction motors capacity 100 HP with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechanical works for shaft/bearing housing , renewal of DE and NDE bearings, transportation from installation to workshop & back including connecting testing and commissioning at site for satisfactorily operation as required etc. complete all as specified and directed.
M&L for Dismantling and taking out defective monoblock pump of capacity 52 LPS. Make- Kirloskar from foundation and shifting to workshop for repair/replacement of impellers, bearings, seals etc. including refixing at foundation after repair testing and commissioning to the entire satisfaction etc. complete all as specified and directed.
M&L for Dismantling and taking out defective centrifugal pump of capacity 123 cum /hr , Make - kirloskar from foundation and shifting to workshop for repair/replacement of impellers, bearings, seals etc, refixing at foundation after repair testing and commissioning complete to the entire satisfaction etc. complete all as specified and directed.
M&L for checking/repair/calibration of microm adjuster of compressor control panel, model-VLRP single, type deluxe (Make- Softhard intelli Sys) etc. complete all as specified and directed.
S&F in repair microprocessor based controller of compressor control panel of 80 TR central AC plant with internal wiring and connections etc. complete all as specified and directed. Make:- Voltas/ Softhard Intelli/ Seimens.
M&L for replacement of PVC water tank heavy duty of capacity 5000 ltrs with CI strip ground around it to avoid bulging/deformation of tank as per existing including plumbing work etc. complete all as specified and directed. Make- Sintex / Polycon or equivalent in
M&L for refrigerant oil for compressor etc. complete all as specified and directed. Make- HPCL- N 68/ Indian Oil- Servo-Friz/ BPCL-Freezol 68.
S&F in repair contactor of LT panel of AC plant, MNX 18, AC supply, 230V, 50HZ , 4 Pole etc. complete all as specified and directed. Make- L&T /Siemens /ABB.
S&F in repair contactor of LT panel of AC plant, MNX 22, AC supply, 230V, 50HZ , 3 Pole etc. complete all as specified and directed. Make- L&T /Siemens /ABB
S&F in repair contactor of LT panel of AC plant, MNX 25, AC supply, 230V, 50HZ , 3 Pole etc. complete all as specified and directed. Make- L&T /Siemens /ABB
S&F in repair contactor of LT panel of AC plant, MNX 32, AC supply, 230V, 50HZ , 3 Pole etc. complete all as specified and directed. Make- L&T /Siemens /ABB
S&F in repair front mounting add-on aux, contact block for contactor of LT panel of AC Plant, MNX - A1 or MNX-A2, AC, 415V, 50 Hz etc. complete all as specified and directed. Make:- L&T/Siemens/ABB
S&F in repair single phasing preventer of the LT panel of AC plant, 3 phase AC, 415 volt, 50 Hz etc. complete all as specified and directed. Make:- L&T/Minilec or equivalent in
S&F in repair MCB TP, 63 amps, AC, 10 KA, 'C' series of the LT panel of AC plant etc. complete all as specified and directed. Make- Legrand/ Schneider/Hagar.
S&F in repair MCB TP, 40 amps, AC, 10 KA, 'C' series of the LT panel of AC plant etc. complete all as specified and directed. Make- Legrand/ Schneider/Hagar.
S&F in repair contactor of compressor control panel AC,415 V, 50 Hz, 3 Phase, Model 3TF47 etc. complete all as specified and directed. Make- L&T/Siemens/ ABB
S&F in repair contactor of compressor control panel, AC, 415 V, 50HZ, 3 phases etc. complete all as specified and directed. Model 3TF49. Make- L&T/ Siemens/ ABB.
S&F in repair thermal overload relay of range 9-15A, 14-23A, type direct mounting on MNX, for control panel etc. complete all as specified and directed. Make- L&T /Siemens/BB.
S&F in repair contactor of compressor control panel, MNX 140, 3 Phase AC, 415V, 50Hz etc. complete all as specified and directed. Make- L&T/Siemens / ABB.
S&F in repair magnetic solenoid coil, 220 volts, AC supply as per existing etc. complete all as specified and directed.
S&F in repair transducer PT3-30 Bar of compressor with harness as per existing etc. complete all as specified and directed.
S&F in repair digital timer of compressor control panel, time range 3-60 secs, 24/200-240V, 50HZ as per existing etc. complete all as specified and directed.
M&L for filling of refrigerant gas R-407 for central AC plant in topping up during servicing / maintenance as required etc. complete all as specified and directed.
S&F in repair rubber coupling of motor and compressor as required etc. complete all as specified and directed.
S&F in repair V belts for AHU motors of existing size and type as required etc. complete all as specified and directed.
S&F in repair heating elements of 2.0 KW capacity of lengths from 1.5 to 2.5 ft as per site requirement etc. complete all as specified and directed.
S&F in repair heating elements of 3.0 KW capacity of lengths from 1.5 to 2.5 ft as per site requirement etc. complete all as specified and directed.
S&F in repair phase indicating lamps LED type with the colour code as per existing etc. complete all as specified and directed.
S&F in repair water pressure indicating gauge fitted in water circulation circuit minimum range 0 to 7 kg/sqcm etc. complete all as specified and directed. Make- IEBIG/H-Guru/Gluck.
S&F in repair water temperature gauge fitted in water circulation circuit minimum range 10 to 50 degree centigrade etc. complete all as specified and directed. Make -IEBIG/ H-Guru/ Gluck
S&F in repair high flow HEPA filter, box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13, capacity 2000 CFM of size 610mm x 610mm x 305mm etc. complete all as specified and directed. Make : Thermadyne/ Puromatic /Primide /Dyna.
S&F in repair high flow HEPA filter box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13, capacity 1000 CFM of size 610mm x 305mm x 305mm etc. complete all as specified and directed. Make : Thermadyne/ Puromatic /Primide /Dyna
S&F in repair high flow HEPA filter, box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13 and of 1000 CFM of size 305mm x 610mmx305mm etc. complete all as specified and directed. Make : Thermadyne/ Puromatic /Primide /Dyna.
S&F in repair high flow HEPA filter box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13 and of 500 CFM of size 305mm x 305mmx305mm etc. complete all as specified and directed. Make : Thermadyne/ Puromatic /Primide /Dyna.
S&F in repair FINE fiter, flange type efficiency 99.00% down to 5.0 micron and EU 5 of size 610mmx610mm x305mm etc. complete all as specified and directed. Make- Thermadyne /Puromatic/ Primide/ Dyna.
S&F in repair FINE filter, flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 305mm x 610mmx305mm etc. complete all as specified and directed. Make Thermadyne/puromatic/ Primide/Dyana.
S&F in repair FINE filter flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 610mmx 305mmx 305mm etc. complete all as specified and directed. Make- Thermadyne/Puromatic/ Primide/Dyna.
S&F in repair FINE filter flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 305mmX 305mm X305mm etc. complete all as specified and directed. Make- Thermadyne/Puromatic/ Primide/Dyna.
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 610mmx610mmx50mm etc. complete all as specified and directed. Make- Thermadyne/Puromatic/ Primide/Dyna.
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 610mmx305mmx50mm etc. complete all as specified and directed. Make- Thermadyne/Puromatic/ Primide/Dyna.
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 305mmx305mmx50mm etc. complete all as specified and directed. Make- Thermadyne/Puromatic/ Primide/Dyna.
S&F in repair HF type HRC cylindrical fuses of rating from 2A to 32A etc. complete all as specified and directed. Make- L&T/BCH/Havells.
S&F in repair HF type HRC cylindrical fuses of rating from 63A etc. complete all as specified and directed. Make- L&T/BCH/Havells.
S&F in repair HN type DIN fuse links of rating 200A etc. complete all as specified and directed. Make L&T/BCH/Havells.
S&F in repair HN type DIN fuse links of rating 630A etc. complete all as specified and directed. Make L&T /BCH/Havells.
Repair and Maint of 200TR capacity cooling tower including cleaning of cooling tower by removing scale and sludge formation, oiling & greasing of moving parts, replacement of PVC fills and other defective parts as required etc. complete all as specified and directed. (Note:- Parts replaced will be measured and paid separately under respective item of BOQ)
S&F in repairs sprinkler head of size 6th with 4 blades and all accessories etc. complete all as specified and directed.
S&F in repairs PVC drift eliminator etc. complete all as specified and directed.
S&F in repairs PVC sprinkler pipe with end cap etc. complete all as specified and directed.
S&F in repairs tension devices viz. tie rod, turn buckle and clamp etc. complete all as specified and directed.
S&F in repairs pipe louver etc. complete all as specified and directed.
S&F in repairs PVC fills of cooling tower of size 600mm x 300mm x 150mm etc. complete all as specified and directed.
Material and Labour for overhauling of complete of 80 TR capacity chiller unit of Voltas make complete with replacement of worn out /unserviceable parts including piston, piston rings, connecting rod, connecting rod bearings, gudgeon pin, head spring, compressor bearing, crank shaft, oil seal, oil ring, oil plate, compressor cylinder, load/unload assembly, oil pressure valve, suction reed, discharge reed, oil pump, gasket, oil filter, fan belt, temperature meter, pressure meter, LP switch, HP switch, oil failure switch, oil pressure switch, temp sensor, gas sensor, drayer, solenoid coil, chiller main controller circuit, coupling etc. and reassembling the same after complete repair and replacement of parts with accessories as nut, bolts, washers etc. , installation on existing foundation, coupling with existing electrical motor with proper alignment including testing, commissioning etc. complete all as specified and directed. Note :- Servicing & Repairing work of chiller unit to be done by the authorised representative of OEM. All spares parts mentioned in above description as required for repair /servicing shall be deemed to be quoted in this item only.
S&F in repair complete electrical internal wiring of 80 TR Central AC Plant compressor contol panel all as specified and directed by Engr-in-Charge.
Schedule of Credit
Shree Karni Electrovision
M/s Prakash Enterprises
M/S Anil Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .