| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹15.6 L+₹51,602.50 (3.43%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹16.5 L+₹1.4 L (9.53%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹17.0 L+₹1.9 L (12.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹39,300
Closing Date
14 Sept 2020, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT
PROVISION OF GEYSERS 25 LITRES FOR OR LIVING ACCN AND LED SECURITY LIGHTS ON PERIMETER IN FD HOSPITAL AT MAMUN AND SPECIAL REPAIR OF INTERNAL WIRING TO CERTAIN BUILDINGS AT CBS GHAROTA UNDER AGE EM OF GE (S) MAMUN
2020_MES_370268_1
GE(S)/M-42/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH MAMUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹39,300
Yes
3 Oct 2020
18 Aug 2020
16 Sept 2020
18 Aug 2020
14 Sept 2020
2 Sept 2020
18 Aug 2020 - 24 Aug 2020
Amount
Taking down carefully aluminium / copper point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match with existing surfaces, complete all as specified and directed.
M&L for point wiring for one light point / fan point / bell point controlled by one switch with 1.5 Sqmm PVC insulated unsheathed copper conductor single core multistranded FRLS cable and 1.5 Sqmm PVC insulated unsheathed copper conductor single core multistranded FRLS (green colour) cable as earth lead drawn in and including connected non metallic rigid PVC conduit including CI/MS terminal box of required size including 3mm thick plastic laminated top sheet cover including cutting chases to walls and making good the disturbed surfaces to match with the existing specifications, complete all as specified and directed.
All as per Srl item No. 2.00 above but for one 5 pin 6 Amps socket outlet on independent board, complete all as specified and directed.
All as per Srl item No. 2.00 above but for one 5 pin 6 Amps socket outlet on same board other switch, complete all as specified and directed.
All as per Srl item No. 2.00 above but for 16 Amps socket outlet point concealed using 2.5 Sqmm copper conductor FR PVC insulated multistranded copper conductor cable, including 2.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire complete all as specified and directed.
S&F Socket outlet, 5 Pin, 6 Amps, , flush type, 230 Volts AC with polycarbonate body, complete all as specified and directed.
S&F Socket outlet, 6 Pin, 6 and 15 Amps, multipurpose, 2 in 1, flush type, 230 Volts AC with polycarbonate body, complete all as specified and directed.
S&F Switch piano flush button, single pole, one way, 6 Amps, 230 Volts AC with polycarbonate body, complete all as specified and directed.
S&F Switch piano flush button, single pole, one way, 16 Amps, 230 Volts AC with polycarbonate body, complete all as specified and directed.
S&F lamp holder, insulated body with back plate for batten fittings with polycarbonate body, complete all as specified and directed.
S&F ceiling rose, surface bakelite, 3 terminals, 230 Volts AC with polycarbonate body, complete all as specified and directed.
S&F fan regulator electronic step socket type, hum free with polycarbonate body, suitable to control speed of fan from 0 to 100% and connecting electrically, complete all as specified and directed.
M&L for Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store, complete all as specified and directed.
M&L for replacement of submain wiring with two single core FR PVC insulated flexible copper conductor cable of size 6.0 Sqmm and one single core FR PVC insulated flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead, drawn in and including concealed non metallic rigid PVC conduit, medium grade and making good the disturbed surfaces to match with existing specifications, complete all as apecified and directed by Engineer-in-Charge. Note :- Two run of cable with one run of earth wire and PVC conduit shall be measured and paid for as one unit.
S&F of surface mounted 1 x 20 Watt LED batten tube light fitting (4 feet long) with high output diffuser including LED lamp in built with all accessories and PVC Round / Square block for fixing of fittings and connecting with ceiling rose using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable and testing etc, complete all as specified and directed.
S&F of surface mounted 1 x 10 Watt LED batten tube light fitting (2 feet long) with high output diffuser including LED lamp in built with all accessories and PVC Round / Square block for fixing of fittings and connecting with ceiling rose using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable and testing etc, complete all as specified and directed.
S&F of bulk head 10 Watt LED light fittings IP 43 in engineering plastic housing with clear primatic diffuser, including LED lamp with all accessories and connecting with ceiling rose using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable and testing etc, complete all as specified and directed.
Supply, fixing and testing of 72 Watts LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete having efficiency >100Lm/w, available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
S&F of 12 Watt LED lamp including testing, complete all as specified. Note for srl item No 15 to 19 here-in-above:- 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.
S&F in replacement sheet metal enclosure MCB distribution board, single pole & neutral, 240 Volts, 8 Way with IP-43 IK-09 protection, double door, complete with appropriate size bus bar and neutral link and including cutting chases to wall for fixing enclosure and making good the disturbed surface to match with existing specifications, complete all as required at site and directed by Engineer-in-Charge.
S&F in replacement MCB single pole, 230 Volts, 6 to 40 Amps with repturing capacity 10 KA 'C' Curve including providing thimble for outgoing cables, complete all as specified and directed.
S&F in replacement MCB single pole and neutral, 240 Volts, 6 to 40 Amps with repturing capacity 10 KA 'C' Curve including providing thimble for out going cables, complete all as specified and directed.
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
S&F single pole and nutral enclosure with a two pin and earth plug and socket with one single pole MCB 10 Amps 240volts complete all as specified and directed.
S&F electric storage water heater of capacity 25 litres BEE 5 star rated including proper installing arrangment on wall surface with suitable Anchor bolt fatser and Geyser connections for hot and cold water supply made of stainless steel wire braided connrtector with chrome finish heavy duty nuts of 15mm size with suitable lengh etc complete all as directed by Engineer-in-Charge.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm.
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm.
S&F 15 mm bore stop valve, cast copper alloy fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F 15 mm bore bib taps, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
Supply and laying 15 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
M&L wiring for circut/submain wiring along with earth wire with the following sizes of FLRS PVC insulated copper conductor single core cable in surface/recessed as required of size 2x4Sqmm + 1x4Sqmm earth wire in PVC rigid conduit with all fittings such as elbow, tee, bends etc complete all as apecified and directed. Note :- Two run of cable with one run of earth wire and PVC conduit shall be measured and paid for as one unit.
S&F MCB single pole, 230 Volts, 6 to 32 Amps with repturing capacity 10 KA 'B' 50Hz, complete all as specified and directed.
S&F MCB single pole and neutral, 230 Volts, 10 to 63 Amps with repturing capacity 10 KA 'B' 50Hz, complete all as specified and directed.
S&F sheet metal enclosure powder coated distribution board, single door 4 Way suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240volts and neutral confirms to IS 13032-1991, complete all as required at site and directed.
Supply and lay in trenches/on wall/on pole/in duct/through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 16 Sqmm 4 core size. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out.
All as per item No. 36.00 above but exc. 1.5 m and n. exc. 3 m deep.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed.
Supply and fixing GI tubing light grade 50 mm bore cut to size and fixed along the pole for cable protection including suitable clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed.
Supply and connecting single core FRLS PVC insulated copper stranded cable of size 1.5 Sqmm for street lights/flood lights passing through pole holes/GI pipe/PVC conduit to junction box and connected electricallu including taking down old unsv wire any type and make complete all as specified and directed.
Supply and erecting in true vertical position steel tubular swaged poles of 9.50 metres long, type 410 SP-31 complete with cast iron base plate, goose neck bracket, finial taper plug , bolt, nuts & screws as specified and painting internal surface with anti-corrosive paint and external surface painting up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primer, including demolition of PCC, complete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in pedestal/coping including necessary weathering and form work etc complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
Supply and fixing bracket for street light fitting made out of 50mm dia GI pipe light grade 1.5 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 25X4mm flat iron including GI nuts, bolts & washer and painting of clamps and street light fitting brackets with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed.
Supply and fixed of pole mounted street light factory fabricated junction box of size 300 x 160 x 250 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including63A ,Three Phase four wire having four no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Sizehaving Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer complete all as specified and directed.
Supply, installation, connecting electrically and testing of street light panel box complete in replacement with Astronomical timer ,contactor rating 65 Amp, MCB 63 A TPN complete for mounted made out of CRCA sheet 1.6 mm thick, powder coated, having provision for Astronomical Timer, Contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement all as required at site, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M/S INDIAN ELECTRICAL
Ashoka Engineers
KULBHUSHAN AGGARWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .