Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.1 L+₹41,735.80 (1.45%)Rejected-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹33.9 L+₹5.2 L (18.1%)Rejected-AOC SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L3 | Rejected-AOC Rejected |
Tender Value
₹25.6 L
EMD Value
₹51,220
Closing Date
4 Feb 2020, 6:00 pmClosed
GE Gomantak
GE Gomantak, Vasco Goa 403 802
Provn of cemented base for VSAT Antennas behind new technical bldg of COMCEN Goa bathroom with urinal and RCC retaining wall besides duty room INWTC Goa deficient washing maintenance ramp for unit vehicle at 2W Det provn of covered shed adjacent at
2020_MES_312511_1
8983/E8
Open Tender
Support/Maintenance Service
Works
270 days
Vasco Da Gama
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Gomantak
₹51,220
Yes
23 Nov 2021
7 Jan 2020
5 Feb 2020
7 Jan 2020
4 Feb 2020
17 Jan 2020
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil all as specified and as directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/disintegrated rock all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil all as specified and as directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock all as specified and as directed
M&L for Cement concrete (1:4:8) type D2 (using 40mm graded aggregates) as in foundations, filling and mass concrete all as specified and as directed.
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work.
Use & waste of formwork to sides of pilars,posts, struts, piers, columns and sides of retaining wall, rough finished surfaces of concrete all as specified
Formwork to sides and soffits of roof beams, beam haunchings, girders, bressummers, including supports, overhangs, etc. also splays between floors and beams, etc.
Use & waste of Formwork to chajjas, incl edges and similar work; not exceeding 200mm thick (Horizontal or sloping)
Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
All as per item No 11 above but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders
M&L for RCC Design Mix M- 25 using (20mm graded stone aggregate) as in foundations footing, plinth beams, bases for columns and and mass concrete complete all as specified.
M&L for RCC Design Mix M- 25 using (20mm graded stone aggregate) as in columns, pillars, posts & struts complete all as specified.
M&L for RCC Design Mix M- 25 using (20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L for RCC Design Mix M- 25 using (20mm graded stone aggregate) as in chajjas complete all as specified.
M&L for RCC Design Mix M- 25 using (20mm graded stone aggregate) as in roof slab supported on walls, beams and columns (Horizontal or sloping) complete all as specified.
M&L for Pre-cast cement concrete type C1 (1:3;6) using 20 mm graded aggregates block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4) complete all as specified and as directed.
M&L for Pre-cast providing cement concrete type C1 (1:3;6) block masonry with solid blocks, 10 cm in width and setting in mortar (1:4) complete all as specified and directed.
Returning, filling in , including, spreading, levelling, watering and well ramming in layers not exc 25cm thick hard/dense soil complete all as specified and directed
Returning, filling in , including, spreading, levelling, watering and well ramming in layers not exc 25cm thick soft rock complete all as specified and directed
Removing excavated materials (soft/dis integrated rock) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
Removing excavated materials (soil of any type) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M & L Hard core broken stone or boulders of gauge exc 63 mm but n exc 100 mm, deposited , spread and levelled in layers n exc 15 cm thick, watered and rolled/rammed to true surface.
M&L 100 mm thick cement concrete type, C2 1:3:6 using (40 mm graded aggregate) as in sub base of floor all as specified and as directed.
M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finish CM: 1:4 all as specified and as directed.
M&L Non - skid colour Ceramic tiles 7 to 8 mm thick square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
M & L rendering cement plaster 10 mm thick with CM 1:4 as backing coat to receive tiles on vertical surfaces all as specified and directed.
M & LGlazed ceramic tiles as in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles all as specified and directed.
M & L 15 mm thick rendering on fair faces of concrete in CM 1:6 finish the surface even & smooth without using extra cement complete all as specified and directed
M & L 15 ( 10+5) mm thick rendering in two layer on fair faces of concrete in CM 1:4 finish the surface even & smooth without using extra cement including mixing with WPC @ 200ml per bag of cement for 2nd coat of 5mm thick plaster complete all as specified and directed . (Note : WPC shall be measured and paid for separetely)
M & L 5 mm thick rendering on soffit of slab in CM 1:3 finish the surface even & smooth without using extra cement complete all as specified and directed
M & L for rendering in CM 1:3, 10 mm thickness on roof slab finishing the surface even and fair with out using extra cement.complete all as specified and directed
Supply only Liquid water proofing compound.
S & F water proofing treatment to the roof slab and chajja using 4mm thick APP modified membrane consisting five layer membrane with features as specified, weighing not less than3.50 kg/Sqm laid over a coat of cold applied bituminous primer @ 0.2 litre per Sqm on surface provide a layer of APP modified membrane by torching application including sealing the overlap with torching with 150 mm on length side and 100 mm on width side as per manufacturer's instruction and provide a finishing coat with solar reflective bituminous aluminium paint @ 0.10 kg/m2 as prescribed by manufacturer of membrane to the satisfaction of Engineer-in-Charge. Note:- 1. Irrespective of the lap the net covered area shall only be measured for payment.
M&L 75mm thick cement concrete type, C2 1:3:6 using (40 mm graded aggregate) as in plinth protection sub base of floor finish the surface all as specified and as directed.
M&L 75mm thick PCC type, C2 (1:4:8) using (40 mm graded aggregate) as in sub base of floorimg all as specified and as directed.
Suppling & fixing in opening Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, all as specified and as directed.
Supplying & fixing in frame Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, as per specification all as specified and as directed.
S&F 100mm long Stainless steel Butt hinges fixed to door frame all as specified and as directed..
S&F 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed all as specified and as directed.
S&F 150 mm long Fancy type Aluminium handles, cast type, anodised all as specified and as directed.
S&F 300 mm long Aluminium anodised, Sliding bolts of extruded section and fixed all as specified and as directed.
S & F powder coated (50 micron) window or ventilator shutter and frame any type (slidding or openable) with frame or other similar work etc section fabricated by using the JINDAL/ INDAL /HINDALCO /sections including necessary roller,wheel cleat handle locking arrangements also to receive 4.8mm thick glass with aluminum chanel beading and stainless steel screw including beading etc complete (the weight of rubber gasket beading will not be measured with the weight of aluminum shutter glass shall be measured and paid separately)All sections as approved by GE
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/ Rectangular n exc 0.5 sq. m in each pane all as specified and as directed..
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe Urinal all as specified and as directed
S&F 25mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe all as specified and as directed
S&F 15mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe all as specified and as directed
S&F 25mm dia Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 25mm- 92gms) all as specified and as directed.
S&F 25mm dia Stop valve cast copper alloy all as specified and as directed.
GI pipe medium grade 25mm dia laid in trenches all as specified and as directed
S&F 15mm dia Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) all as specified and as directed.
S&F Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm- 0gms/20mm- 125gms) all as specified and as directed..
S & F PVC connections 15 mm size with PTMT nuts of length 450mm all as specified and as directed.
S&F Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) all as specified and as directed.
Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour.(Minimum weight 40gms all as specified and as directed.
S&F 1000 Ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I all as specified and as directed.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) all as specified and as directed.
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and as directed
S&F 75mm dia PVC (SWR) waste pipe single socket any length all as specified and as directed
S&F 110mm dia PVC (SWR) waste pipe single socket any length all as specified and as directed
M&L concrete bed to PVC (SWR) waste pipe incl packing under and completely surrounding with concrete after they are laid and tested.
M&L for pre cast cover slab in PCC (1:2:4) Type B1 (using 20 mm aggregate) and setting in CM (1:4) all as specified and as directed
M & L for three coats of white wash on newly plastered ceiling surfaces all as specified and as directed.
M & L for three coats of white wash on newly plastered wall surfaces all as specified and as directed .
M&L preparing plaster surface of new wall and appling two coat of colour wash over coat of white wash all as specified and as directed.
Rough excavation n.exc (not exceeding) 1.5 m deep and getting out hard/dense soil all as specified and as directed.
M&L for RCC Design Mix M-25 using (20mm graded stone aggregate) as in RCC Retaining wall complete all as specified.
Removing excavated materials (soil) to a distance exc 250.0 m and n.exc 500m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
Removing excavated materials (soft/dis integrated rockl) to a distance exc 250 m and n.exc 500m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
Excavation over areas n exc 1.5 m deep and getting out in soft/disintegrated rock for foundation. all as specified and directed by Engr in charge.
M&L cement concrete type C1, 1:3:6 (20 mm graded aggregate) as in coping all as specified and directed by Engr in charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed by Engr in charge.
M&L RCC (Nominal mix) type B-1, 1:2:4 (20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed by Engr in charge.
M&L 50mm thick sand filling under floors or in foundations including watering and consolidation
M&L preparing untreated new surfaces of walls and applying two coats of cement base paint over one coat of primer all as specified and directed
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment all as specified and directed by Engr in charge.
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment all as specified and directed by Engr in charge.
M&L cement concrete type B1, 1:2:4 (using 20 mm graded aggregate) as in surface channel incl necessary form work all as specified and directed by Engr in charge.
S&F Anodised aluminium snap grid frame work for false ceiling including hangers of 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by Engr In Charge.
S&F 10mm thick EPS insulation panels in Celing board with 1mm thick PVC sheet both side and suitable for placeing in false ceiling aluminium grid complete all as specified and directed by Engr In Charge.
M & L 12 mm thick prelaminated particle board, Exterior grade, prelaminated both side with decorative choice lamination fixed in aluminum partition frame work all as specified & directed.
S&F Mortice lock,vertical type, size100 mm long mild steel 4 leverall as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and as directed.
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.and Brushing neat cement slurry with 3.0kg of cement per sq. metre
M&L for 40mm thick Cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in floor , finishing the surface even and smooth without using extra cement all as specified and as directed.
S&F 28mm wide and 3mm thick Glass dividing strips all as specified and as directed.
M&L preparing plaster surface of new wall and applying two coats of OBD over a coat of primer all as specified and directed by Engr-in-Charge.
M&L complete removal of existing treatment of old wall and appling two coats of OBD over a coat of primer all as specified and directed by Engr-in-Charge.
M&L preparing untreated surface of new wall and applying two coats of Anti Fungal paint over a coat of primer all as specified and directed by Engr-in-Charge.
M&L complete removal of existing treatment of old wall and applying two coats of Anti Fungal paint over a coat of primer all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete 1:2:4,Type B1 (using 20 mm graded stone aggregate) as in floor of drain, kerbs including weathering, slightly angles and throating as directed.
M& L steel work in tubular col post incl special shaped washer complete using ERW or induction butt welded tube conforming to IS 1161.
S & F Roof trusses (framed) purlin rail angle fasting ( Angle, plate and flat Iron) with angle cleats or other connecting plates (Fe-410- W(Gde- E-250) quality- B
S&F Pre-painted galvalume aluminium zinc coating GI based corrungated steel sheet 0.56mm thick of and colour having tensile stregth of 550 Mpa as in roof covering/claddding to wall, fixed with self tapping screws as specified.
M&L for two coats of synthetic enamel paint over coat of primer including preparation of newly steel surfaces.
Material and labour for point wiring FRLS complete with 1100 V grade 1.5 Sqmm single core FRLS PVC insulated unsheathed multistranded copper conductor cable drawn through in and including non metalic rigid Concealed conduit of dia 20mm ISI marked with all accessories concealed in wall, ceiling including 1.5 sqmm single core PVC insulated and unsheathed copper conductor cable as earth continuity wire including testing all as specified and directed by Engr-in-Charge for one light point, fan point, exhaust fan point controlled by one switch.
All as per serial item No 100 here-in-before but one 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per item No 100 above but one 3 pin socket outlet 15 Amps independent/metal plug and socket with cables 4 sqmm size copper PVC insulated cable multistranded and 2.5 sqmm cable conductor for earth wire Make : Finolex/polycab
Supply and fixing modular switch one way 6 Amp 1 module.
Supply and fixing modular white cover plate with frame ,3 module.
Supply and fixing metal flush box 3 module.
Supply and fixing modular switch one way 16 Amp 1 module.
Supply and fixingmodular socket , 6 A -2/3 pin combined 2
Supply and fixing modular socket , 15 A -2/3 pin combined 2
Supply and fixing MCB, single pole, 6-32 Amp, 240 Volts, 'C' Curve 10KA.
Supply and fixing MCB, single pole and neutral, 6-32 Amp, 240 Volts, 'C' Curve 10 KA.
Supply and fixing sheet metal enclosure (DB) for MCB's, 8 way, single pole and neutral, 240 volts, double door with Copper bus bar with IP 54- IK 09 complete.Make : Legrand (Ekinox 3) or equivalent in C&S/Havells
Supply & fixing ceiling rose, surface Bakelite 65x50 mm Two to three terminals.
Supply and fixing ASTRA surface mounted square LED 18W downlight for soft diffused lighting etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Make : Philips HSN Code No. 94051090 or Equivalent in Bajaj/Havells.
Supply, Laying, joining & testing LT XLPE Insulated & sheathed armoured electric cables with multistranded aluminium conductor cable 1100 volts grade, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes & aluminium lugs for connection for cross- sectional area 10 Sq mm 2 Core complete all as specified and directed.
S&F Drift air Exhaust fan 225mm sweep, metal body AC single phase 240 V with base frame, louvers etc fixed including opening of wall hole for fixing of exhaust fan,by providing necessary nuts, bolts, washers etc including . Make : CG( Drift air) or equivalent in Bajaj/ Khaitan/havells.
Supply and laying of 25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fitting in trenches complete all as specified.
Supply and Fixing Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in 25mm dia pipe Make Make -ZOLOTO/KRILOSKAR.
Supply & Fix in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe of dia 25mm and fixed.
M/S jvsr constructions
Tara Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .