| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.1 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹24.2 L+₹91,137.53 (3.92%)Rejected-AOC QTR NO 7 REHARI COLONY JAMMU TAWI J K PIN 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹24.9 L+₹1.6 L (6.89%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹25.4 L+₹2.1 L (8.93%)Rejected-AOC | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹26.0 L+₹2.7 L (11.7%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
17 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
SPECIAL REPAIR OF PERIMETER SECURITY WALL FENCING, SEWAGE LINES AND PROVN OF ROOF TREATMENT AT KALUCHAK MIL STN UNDER GE KALUCHAK
2022_MES_546444_1
GE/KC/NIT-30/2022-23
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹59,000
Yes
16 Nov 2022
20 Aug 2022
24 Sept 2022
20 Aug 2022
17 Sept 2022
3 Sept 2022
20 Aug 2022 - 27 Aug 2022
Amount
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Use & waste of form work to sides of concrete foundation, footings, bases of columns, rafts and raft beamsand similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to sides of pillars, posts, structs, columns (square, circular rectangular on plan or polygonal etc. for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
Reinforced cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sq. cm but n exc 250 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed including necessary form work, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4 but except brick i.e. using serviceable bricks obtained from Srl item No. 14 here-in-before, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on other than fair faces of brick surfaces or concrete surfaces, finished even and smooth without using extra cement, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint of any tint over a coat of cement primer, complete all as specified & directed.
Rolled mild steel work in posts & struts, wind ties and similar work using angle iron, flat etc, fixed independently without connecting plates, etc. (cut to ordinary length i.e. within 20mm of the length indicated), conforming to Fe-290 grade-E-165 including cutting tops to shape, drilled holes, notching for wire, all necessary drilling, bolting or riveting, etc., complete all as specified & directed. Note : Unit rate is also included locking holes after fixing of barbed wire and welding to bent up portion as directed.
Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified & directed.
Mild steel framed work as in grills, gratings, etc. with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 grade-E-165, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Barbed razor tape concertina coil SG hot galvanised spring tensile wire as approved by GE, dia of coil when stretched 1000mm having minimum number of circles 12 RM to 13 RM, minimum number of clips 15/RM & minimum weight of coil 0.96 Kg/RM hot dip galvanised, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Concrete bed to 200mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 200mm, complete all as specified & directed.
Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 150mm, complete all as specified & directed.
Dismantling/ taking down cast iron or PVC or AC drain pipe of exc 50mm dia including all fittings, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
Vitreous china wash down water closet (Pedestal pattern), white with ‘P’ or ‘S’ trap, plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, fixed with screws of suitable size including making connections to trap and to flush pipe, fixing flushing cistern etc. and making good to floors, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
PVC connections 15mm size with PTMT nuts of length 450mm, fixed in repairs, complete all as specified & directed.
Chromium plated hand shower (Health Faucet) with with 8mm dia 1 meter long easy flex tube in chrome finish & wall hook, fixed in repairs, complete all as specified & directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, 110mm bore, complete all as specified and directed.
110mm bore PVC (SWR) bends any radius, fixed in repairs, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, 75mm bore, complete all as specified and directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed.
75mm bore PVC (SWR) bends any radius, fixed in repairs, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore with oval access door, fixed in repairs, complete all as specified.
PVC (SWR) vent cowl of size 110mm bore, fixed in repairs, complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, fixed in repairs, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:5, complete all as specified & directed .
PCC 1:5:10, nominal mix, type E-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified & directed.
25mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as floor, finished even and fair to receive floor finishes, complete all as specified & directed.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface, roof tiles/concrete padding etc including grubbing up of tree roots, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust for roof treatment work, complete all as specified & directed
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in padding on roof, for levelling of roof slab using liquid water proofing admixture as per manufacturer’s instructions, finished even and fair, complete all as specified & directed. Note : Liquid water proofing admixture shall be measured & paid seperately.
Supply only liquid water proofing admixture, complete all as specifed & directed.
Preparation of the concrete roof surfaces and applying the following Roof Treatment, complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (f) Applying 6th course of one coat of aluminium paint.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick cement mortar 1:3, surface finished even and smooth without using extra cement using integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid seprately.
15mm thick rendering in cement mortar 1:4 on roof / concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Hare krishna engineering const.
M/S Sudagar Mal
JK BUILDERS AND DEVELOPERS
M/S Vishwakarma Builders
KAMAL CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .