Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹70.8 CrAccepted-AOC | ₹70.8 Cr | 1 | Accepted-AOC Scored rank 1 |
| 2 | 2₹74.9 CrRejected-AOC 303 ISCON MALL NEAR BIG BAZAR 150 FT RING ROAD RAJKOT 360001 GUJRAT | RAJKOT | GUJARAT | 360001 | ₹74.9 Cr | 2 | Rejected-AOC Scored rank 2 |
| 3 | 3₹74.9 CrRejected-AOC | ₹74.9 Cr | 3 | Rejected-AOC Scored rank 3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Experience/completion Certificate submitted by the agency is not as per Qualification criteria. |
| 5 | Rejected-Technical DADRA AND NAGAR HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | - | - | Rejected-Technical Experience/completion Certificate submitted by the agency is not as per Qualification criteria. |
Tender Value
Refer Docs
EMD Value
₹91.8 L
Closing Date
21 Aug 2021, 3:00 pmClosed
Zonal Manager
1/123, Vineet Khand, Gomti Nagar, Lucknow
Construction of New Building at Birbal Sahni Institute of Palaeoscience at Lucknow (UP)
2021_NPCC_83365_1
NPCC/UPZ/357/BSIP/21-22/376
Open Tender
Civil Works - Buildings
545 days
Lucknow
Please refer Tender documents.
5 documents required · 5 mandatory
₹59,000
Yes
National Projects Construction Corporation Limited
₹91.8 L
Yes
committee room at BSIP Luckno
9 Oct 2021
29 Jul 2021
23 Aug 2021
29 Jul 2021
21 Aug 2021
29 Jul 2021
29 Jul 2021 - 12 Aug 2021
13 Aug 2021
Abstract of Total Cost of The Building
Main Building
Cost for Civil
Cost for Plumbing work
Cost for Electrical works
External Development Work
External Electrical Development & Fire
Cost of HVAC Work
Description of Work / Item(s)
Amount
Cost for Civil
EARTH WORKS
Carriage of material by mechanical transport including loading, unloading to 5km.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil
BELOW GROUND 1.5 TO 3.0 M
BELOW GROUND 3.0 TO 4.5 M
BELOW GROUND 4.5 TO 6.0 M
BELOW GROUND 6.0 TO 7.5 M
BELOW GROUND 7.5 TO 9.0 M
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts.
Edges of slabs and breaks in floors and walls
Under 20 cm wide
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 40 mm Thick
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Extra for providing richer mixes at all floor levels.
Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/Cum).
Add for using extra cement in the items of design mix over and above the specified cement content therein.
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.
Half brick masonry with common burnt clay (non modular) bricks of class- 150 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement : 3 coarse sand)
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
C/O Apron drain of width 150mm and depth as per required of site but minimum 150 mm with neat finish & required slope as per apporoved by E/I.
MARBLE & GRANITE WORK
Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 Sqm.( For Counter)
Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
WOOD & PVC WORK
Providing woodwork in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid for separately)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
Second class teak wood, 30 mm thick
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters of required size UP teak wood.
Second class teak wood
Providing and fixing SS tower bolts, ISI marked, with necessary screws etc. complete :
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing SS sliding door bolts, with nuts and screws etc. complete :
Single rubber stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
1. mm thick
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows, Doors and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)
Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Providing and fixing factory made UPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and UPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.
STEEL WORK
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing stainless steel ( Grade 304) railing WITH GLASS made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
0.80 mm thick with zinc coating not less than 275 gm/m²
FLOORING & CLADDING WORK
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.8mm thick, Granite of any colour and shade
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).
Red sand stone - 30mm thick gang saw cut stone
Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : Decorative veneer facings of approved manufacture
Providing and fixing plain lining with necessary screws/nuts & bolts/nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-incharge 12mm thick commercial ply conforming to IS : 1328 BWR type
Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete
40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
Makrana white second quality
Extra for pre finished nosing to treads of steps of marble stone.
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.
Kota stone in flooring 20 mm thick and joint filled 1:2 cement and coarse sand with approved colouring materials to be given and even shade with 12 mm base coat (bedding) of 1:4 cement and coarse sand mortar and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour T & P etc. requird for proper completion of the work excluding base concrete. 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Size of Tile 800x800 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
Size of Tile 800x800 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
French spirit polishinG : Two or more coats on new works including a coat of wood filler
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and fixing of 12mm thick laminated wooden flooring laid over leveling layer of cement concrete 1:2:4 ( 1 Cement: 2 coarse Sand: 4 grade stone aggregate 25mm nominal size) to be paid separately
Providing and fixing of façade at all heights with extruded hollow Clay/ Terracotta ventilated rain screen tiles of height 259/ 309/ 409mm and length of 1190 mm of approved texture, design and pattern having Flexural Strength/ Modulus of Rupture of 2 14 N/m2 and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical T' (for intermediates)/ 'L' (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 1200mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x34x2 mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self- drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot-dip-galvanized)
steel L-brackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mm at outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T/L/ Tubular profiles using two numbers self-drilling/ self-tanning SS screws of size 5 5x25 mm with EPDM washers.EPDM gaskets to be fixed in between brackets and
vertical profies. the tiles shall be mounted on the 'C'clamps such that the tiles are supported at top and bottom at both ends. the tiles shall be mounted on the C-clamps with EPDM profiles in between such that the tiles are supported at top and bottom at both ends. the vertical joint open groove between two adjacent tiles shall be 10mm. the tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. the tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the facade tiles and the structural wall. the work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge.
with 24mm thickness (+/-10%) terracotta tiles of other than grey colours
Providing and laying of printed saxony carpet of CARUS Brand, manufactured by Beaulieu International Group or equivalent, having 100% Type 6' Nylon/Polyamide Crealon or equivalent and 1/10 gauge, . The carpet should have a primary backing of woven pp and secondary backing of weaveback to ensure high performance and comfort. The carpet should be of 4M width to ensure lesser joints and minimum wastage. It should have a minimum total weight of 1650 gsm and minimum pile weight 800 gsm , minimum number of tufts to be 185040 or more The carpet should also qualify to the following minimum European standards performance specifications - (a) Fastness to rubbing, dry (ISO 105 X-12), minimum rating should be 4-5; (b) Fatness to rubbing, wet (ISO 105 X-12), minimum rating should be 5; (c) Water fastness, (ISO 105 E-01), minimum rating should be 4-5; (d) Fastness to light (ISO 105 B-2), minimum rating should be 5; (e) Thermal Resistance (ISO 8302), minimum rating should be 0,072 m² K/ W; (f) Impact sound insulation (ISO 140 - 8), minimum rating should be 25dB. The carpet should be Scotchguard ready for better stain resistance, and should have an approved fire rating of Class 1 under Bf1S1 and should be recommended for commercial usage under Class 23/32 classification." duly installed on smooth hard floor with support of 10 mm epe sheet & company recommended adhesive with metal edge profile
Providing and laying of Epoxy flooring
Providing and Fixing MRI Led Sheet as per specification & direction of Engineer-IN-Charge
ROOFING
Providing and laying gola 75x75mm in cement concrete M15 grade including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately):
Flat surfaces
Curved surfaces
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/ mK.
Providing and fixing Aluminiuml Clip in Metal Ceiling System of600x600/ 300x1200 & more module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :
AluminiumI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600/300x1200 & more etc and 0.5 mm thick with 25 mm height, made of AluminiumI sheet 60 microns (minimum
FINISHING WORK
12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand) ON INNER SURFACE
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) External plaster
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level:
In two coats
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade :
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
PU paint over leaf and Toilet doors
Providing and Applying 2 or more coats of Luxury Emulsion with Silver Ion Technology recommended by Indian Health Association, which kills 99% of infection- causing - bacteria on the painted surface and improves indoor air quality by reducing formaldehyde, a harm pollutant. Over modified acrylic, water-based alkali resistant primer with silicone additives, resist alkali up to PH 12.5 and moisture resistant up to 15%.Over base of 2 to 3 MM ,water resistant cement modified compound with special additives , Single pack fiber reinforced powder that over old or new surface plastered surface walls, concrete blocks and mivan structure to provide a smooth surface, hydrophobic and breathable in nature.
Two coats
ALUMINIUM WORK
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Filling the gap in between aluminium frame and adjacent RCC/Brickwork/ Stone Work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge
Upto 5mm depth and 5mm width
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, including all patch fittings all complete as per drawings, direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately).
Providing and fixing Stainless steel 304 Grade H- type pull handle of size min 32 mm dia and 1200mm long of approved make including SS screws, including making holes of required size in shutter etc. complete as per direction of Engineer-in-Charge.
Providing and fixing SS Bottom patch Lock with cylinder of approved make including necessary screws etc. all complete.
Providing and fixing SS floor mounted half dome door stopper of dia 45mm including necessary screws etc. all complete.
Double Skin Modular Clean Room Wall Panels composite system 80 mm thk made up of sheet thk 0.8 mm GPSP/ FS sheets ( TATA make) epoxy polyester Powder Coated (NLT 60 micron) GPSP (Galvanised Plan Skin Pass zero Spangle ) sheets on both side with puff having density 40kg/m3 as infill with GI Profile for reinforcement along the periphery an floor track to accommodate the Epoxy floor coving Flush with the wall panel with relevant fittings and material required, Cut out for electrical board ,Magnehaulic guage etc. . All Joints will be completely sealed with clean room compatible silicon
Scientific Metal Doors designed to fit flush into the wall panel system on both sides.Doors are fabtricated from GPSP sheet duly powder coated (thk 70-80 micron with approved color). Leaf having sheet thickness of 0.8mm and the frame of 1.2mm. Infill material will be Papercore with provisions for double glazing glass and hardwares like push plate, door closure, SS D handle, SS ball bearing hinges, concealed tower bolt for the double door etc.
SINGLE GLAZED ALUMINIUM TOUGHENED GLASS PARTITIONS MICRA I (26 X 30MM) Supply and installation of full height Single glazed partition using 10mm thick toughened Glass fixed with proprietary anodized aluminium sections of size 26x30mm (H) on top, bottom, horizontal & vertical. Rate to include required accessories as per the manufacturer's specifications and shall be inclusive of all accessories like Gaskets. Glass to glass joints to be sealed with Double sided 2mm Thick transparent tape. The glasses to be butt jointed with 2 to 3mm edge chamfer & edge polishing all around.Achieving value of 31 dB. ( Rate is not included for door frames). Finish - Black Anodised Partition Height - 2400mm System - Micra I Glass - 10mm Toughened Glass Make - Liko-s
Providing and fixing of DORMA frameless Automatic bi-parting sliding door operator for clear opening size of 2000 mm x 2400mm, modular design, including internal cover, eagle sensors on both side, Electromechanical lock,light barriers and programme switch complete, With Operator Dimensions (Lx H xT): 4150x 100 x 180 mm. The track profile should be separate from the main profile for enabling reduction in vibration. Microprocessor controlled control unit. It should be Selflearning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in- Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
a)Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Providing, assembling and supplying visionglass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge.
WATER PROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-chargeover 20 mm thick layer of cement mortar of mix 1:5 (1 cement:5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mmsquare 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
EXTRA ITEMS
Supply and Installation of polycarbonate multi-layered system, a complete assembly of extruded multilayer UV protected polycarbonate panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 18 mm thick panel of 1050-1200 mm width for bigger spans and minimal junctions for better performance. Panels shall have minimum seven layers with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical offset standing seam at both sides of the panel. Panels shall provide angular daylight for better shading and variable day light transmission throughout the day with translucent and opaque combination of layers. Panels have to be fixed on Purlin with snap on connectors with grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate Panel which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.8 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Color: As per Approval. Approved Make: DPI Daylighting/ Bayer/ Polygal/ GE/ Vergola or Equivalent.
TERRACE GARDEN WATER PROOFING Repairing cracks by cutting and making V-groove in 25x25 mm, with polymer modified mortar using Pidicrete URP, filling the groove with CM(1:3) mixed with polymer 10% by weight of cement(cement, sand ,water will be supplied by the client) Spray apply an average 50mm thick Foamshield insulation with a core density of 45-50 kg/m3, thermal conductivity of 0.020 W/m.k at 25 degree mean temperature as per ASTM C518/91, compressive strength with rise of 4.2 kg/cm2 as per ASTM D- 1621/94, fire resistance property confirming to class B2 as per DIN 4102 Provide and apply Roofseal, which is a single component cold applied elastomeric waterproofing coating based on synthetic resin Emulsion applied with a brush/roller in 2 coats to achieve a DFT of 0. 75-0.80mm (consumption @ 1.5 liters/Sqm)
Providing & laying 150GSM geotextile layer. Laying of average 75mm thick (or suitable thickness for necessary slope)fibrated concrete screed of M 20 grade with Glass / Polypropylene fibers shall be cast into these bays, from a RMC pump (concrete to be supplied by civil contractor) Over the concrete applying NewcoatEzee, a UV resistant, fiber reinforced water based acrylic waterproofing cum SRI coating with a roller/brush only for hardscape terrace.
Additional for Landscape Terrace: Over the concrete applying three coats of Coal Tar Epoxy @0.5Kg/Sqm/3coats as a anti root barrier before application of Drainage board, soil filter etc. Supply and installation of “Tikidan” / "Uniseal / Delta Terraxx" Rolled Matrix Soil Filter cum surface drainage System as per manufacturers specifications. “Tikidan"/ "UNiseal", or, “Delta Terraxx” consist of dimple raised, moulded polypropylene sheet bonded to a high strength polypropylene geotextile fabric This geotextile fabric composite allows passage of moisture through fabric while preventing fine soil from entering to drainage channel.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm at Terrace level, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Providing and fixing Unistone wall cladding on interior and exterior wall of terrace garden
Description of Work / Item(s)
Amount
Cost for Plumbing work
SANITARY INSTALLATIONS & C.P FITTINGS
Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked black solid plastic seat and lid
Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.
a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe
40 mm dia
Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required.
Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
Kitchen sink without drain board Size 610x510 mm bowl depth 200 mm
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :
Size 450x300x150 mm
Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:
Range of two half stall urinals with 5 litre PV.C. automatic flushing cistern.
Range of Three half stall urinals with 10 litre PV.C. automatic flushing cistern.
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
CP Brass fittings
Providing and fixing unplasticised PVC connection pipe with brass unions
15 mm nominal bore
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore
Sink Mixer with Swinging Spout (Table Mounted Model) with 450mm Long Braided Hoses (CQT-23309B jaguar)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
C.I. SOIL WASTE & VENT PIPES AND FITTINGS
Providing & fixing soil, waste and vent pipes.
a) 100mm dia centrifugally cast iron S & S pipe.
b) 75mm dia centrifugally cast iron S & S pipe.
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. ( for wash basin waste )
32mm dia nominal bore
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters.
Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.
a) for 100mm dia pipe.
b) for 75mm dia pipe.
Providing & fixing cast iron coller.
a) 100mm dia.
b) 75mm dia.
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
a) 100mm inlet & 100mm outlet.
a) 100mm inlet & 75mm outlet.
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.
Providing and fixing plain bend of required degree.
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
Providing and fixing centrifugaly cast iron single equal plain junction of required degree.
Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :
Providing and fixing single unequal plain invert branch of required degree :
Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.)
Providing and fixing cast iron terminal guard.
Providing and fixing in floor and wall face Ringfit chempro ASTRAL ULTRADRAIN Conventional system for lab sink waste water pipes (HSN Code 39172390)
40mm. dia.(HSN Code 39172390)
100mm. dia.(HSN Code 39172390)
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
100mm. dia.
Providing and fixing on wall face chempro fittings/accessories for chempro pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. (Make : Astral (HSN Code 39174000)
a) Providing & fixing chempro 90˚ elbow (HSN Code 39174000)
40mm. dia.
100mm. dia.
b) Providing & fixing chempro 45˚ elbow (HSN Code 39174000)
100mm. dia.
c) Providing & fixing chempro TEE Band (HSN Code 39174000)
100mm. dia.
g) Providing & fixing chempro Coupler (HSN Code 39174000)
40mm. dia.
100mm. dia.
I) Providing & fixing chempro Clean out plug
100mm. dia.
INTERNAL RAIN WATER DRAINAGE WORK
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
160 mm dia
Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. (Make : Astral )
g) Providing & fixing UPVC Coupler
i) 160mm dia
a) Providing & fixing UPVC 90˚ elbow
i) 160mm dia
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
INTERNAL WATER SUPPLY WORKS
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
Concealed work including cutting chases and making good the walls etc.
20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes
32mm dia nominal outer dia pipes
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work).
Internal work-Exposed on wall
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
65mm dia nominal bore
80mm dia nominal bore
Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work.
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
65mm dia nominal bore
80mm dia nominal bore
Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
65mm dia nominal bore
80mm dia nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality.
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
65mm dia nominal bore
80mm dia nominal bore
RO Plant 500 LPH (Liter per hour)
PLANT CAPACITY - 500 LPH RECOVERY - 50% ELECTRICAL CONNECTION - 415 V, 3 PHASE, 50 HZ TDS - < 100 PPM
1000L STORAGE TANK AND DRINKING FOUNTAIN
Supply of wall hanging drinking online water cooler with bottle filler facility, made by stainless steel top and heavy duty galvanized steel frame. With cooling capacity, ADA Compliant, size 472 mm Depth X 447mm width, flexible bubbler guard , operated between 50 to 120 PSI, Chiller unit Suitable to R134a Refrigerant, Adjustable thermostat control, suitable for 220-230v/50-60 hz A/C Supply Complete with all accessories which include MD-CU29, which is an EPA registered antimicrobial copper that fights off microorganisms which include MRSA and e-coli. The water Fountain shall possess NSF-USA, Green building, energy star saving certification, and to be placed at different location of buidling. As per Enginner Incharge- Make Oasis/ Filtrin/ Eureka Forbes
Supplying and fixing safety shower -Emergency Full Body Shower & Eyewash Station (Hand Operated & Foot Operated) with two water outlets / showers - One For face Protection at lower level & second for full body protection. Both the showers can either be operated simultaneously or singularly as per the requirements. Showers are fitted with pull chain for body showers as well as foot operated for the face wash. Material of construction: Pipe line in GI heavy grade confirming to IS: 1239. Self Closing valve in Gun Metal Bowl for eyewash in stainless steel 304 grade IC Eyewash nozzles in stainless steel 304 grade IC Shower head in stainless steel 304 grade IC Foot pedal in MS Galvanized Spring in MS Galvanized Pull Chain in MS Galvanized
INTERNAL SEWERAGE SYSTEM
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.
All kinds of soil
Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
100mm diameter
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design
100mm dia SW pipe
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
150 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
150 mm. dia. RCC Pipes
Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
150 x 100 mm size P type
With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
With FPS bricks of class designation 75 (i) For Sewer Line
Extra for depth for manholes:
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design
With 20x20 mm square bar
EXTERNAL SEWERAGE SYSTEM
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
up to 1.50 m depth
Pipes 80 mm to 300 mm diameter
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
Depth not exceeding 1.5 meter
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
150 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
150 mm. dia.
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
With common burnt clay FPS (non modular) bricks of class designation 75
(i) For Sewer Line
Extra for depth for manholes:
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).
With common burnt clay FPS (non modular) bricks of class designation 75
(i) For Sewer Line
Extra for depth for manholes:
Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
EXTERNAL RAIN WATER DRAINAGE SYSTEM
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
up to 1.50 m depth
Pipes 80 mm to 300 mm diameter
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
150 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
150 mm. dia.
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
With common burnt clay FPS (non modular) bricks of class designation 75
(i) For Sewer Line
Extra for depth for manholes:
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
Constructing brick masonry INSPECTION chamber 60x60x90 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as per design. With FPS bricks
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
SUMP FOR BASEMENT
Size :- Length = 1.50 M. Width =1.50 M Total Depth =1.50M
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and remova of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Providing and fixing gun metal non- return valve of approved quality
65 mm nominal bore
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
65mm dia
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
65mm dia
Kirloskar make sump pump Model 2200CW, 5 HP, 3 Phase, delivery pipe size 65 mm,
Description of Work / Item(s)
Amount
COST FOR ELECTRICAL WORKS
SUB-HEAD - I : INTERNAL WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(GROUP C)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed pvc conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
4 X 25 sq. mm + 2 X 10 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 63 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required
25mm dia conduit
32mm dia conduit
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20mm dia conduit
25mm dia conduit
32mm dia conduit
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Telephone wire:- Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Extra Modular switch/socket outlet:- Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Extra GI box along with modular base and cover plate:- Supplying and fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mm x 75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Raceways and Junction Box:- Supply & fixing of PVC raceways for following sizes with all accessories like coupler,bends,risers and fixing brackets along with covering complete in all respect equivalent to Legrand Model 0896
100 mm X 38 mm, 2 Compartment PVC Race ways
150 mm X 38 mm, 3 Compartment PVC Race ways
Supply & fixing of GI raceways for following sizes with all accessories like coupler,bends,riser and fixing brackets along with covering complete in all respect equivalent to Legrand Model 0895
100 mm X 38 mm, 1 Compartment GI Race ways
150 mm X 38 mm, 1 Compartment GI Race ways
225 mm X 38 mm, 3 Compartment GI Race ways
Junction Box with option 4 Module mounted on race way with adjustable option for following sizes along with cover plate etc complete in all respect. Make Legrand
Supply and fixing of GI Floor Box with 3 Compartments (264X264 mm) height 86 mm with Cover with and provision of cable entry complete in all respect equivalent to Legrend Model 6896
Supplying and fixing metal box of following sizes (nominal size) in floor, surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
100 mm X 100 mm X 60 mm deep
150 mm X 150 mm X 60 mm deep
200 mm X 300 mm X 60 mm deep
SUB-HEAD II - FANS & LIGHT FIXTURES:
Down Lighter
Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT AAA)
SITC of LED Wall bracket Luminaire with E27 base lamp holder suitable for LED bulb of wattage 12W with chrome lamp cup. Similar to Wipro LM91 or equivalent
Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT AAA)
Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT AAA)
For Double height:- Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects.(CAT AAA)
2'X2' Square Fittings
Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.(CAT AAA)
LED Tube Light
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect.(CAT- AAA)
Supply and fixing of LED Tube Light with batten suitable for up to 2 X 22 watt LED tube light fitting including tube on Surface complete in all respect.(CAT- AAA)
Supply and fixing of 1'X4' ,62W,6000 Lumen with CRI>80,SDCM<5,CCT-6500 K,THD<10%,IP 65,clean room fitting with all mounting arrangement and connecting copper wire equivalent to Philips-CR652B(1X4)
Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect.
Supply and fixing of Single LED light wall bracket 3 to 6 Watt on matching M.D.F.E.G Board base etc. complete in all respect.
Supply and fixing of 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect.CAT-AAA
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 70 to 90 Watt. Confirming to IP 65 protection complete in all respect.(CAT - AAA)
Supply and fixingof Mirror Wall Light oblong 10 Watt LED luminaire with driver set confirming to IP 65 and above Protection . complete in all respectsimilar to Philips model No. BN021 LED 10S.
Supply, installation, connecting, testing and commissioning of illuminated exit sign with 1 x 6 watt LED lamp including providing maintenance free batteries & charger capable of working for 2 hr duration mounted on ceiling/wall complete with the approved EXIT self adhesive labels as per site requirement as required including connection with 1.5 sqmm FRLS PVC insulated copper conductor similar to Prolite or equivalent
Supply & installation LED cove strip 5 Meter length similar to philips Cat No. LED Strip SKYCove 5M WW with copper wiring for looping
Supply,Installation, Testing and Commissioning of Specialized 20 watt LED Track lighting system for Museum alogwith with sensors required and track light accessories etc complete in all respect.Similar to Philips Cat No ST271T LED20/840or Panasonic cat No ATR020206
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying, erection, connecting, testing and commissioning of 750 mm wall circulating fan complete in all respect including fixing wiring connection etc Similar to Usha Dominaire
Supplying, erection, connecting, testing and commissioning of 400 mm wall fan complete in all respect including fixing wiring connection etc Similar to havells Platina
Supplying, erection, connecting, testing and commissioning of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.
380mm 900 RPM
450mm 900 RPM
Supply and fixing of single unit LED aviation obstruction light complete with transformer and LED spiral etc complete in all respect..(CAT AAA)
Add extra to item (1116) for 15cm or part thereof for room height from 3.5 to 5.00 metres.
Making hole in the wall for exhaust fan and finishing properly complete in all respect.
Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
Supplying and fixing M.S. box with Phenolic laminate plate 4- way splitter box for TV antenna complete as required.
Supplying and fixing of 450 x 450 x 150 M.S. box with Phenolic laminate plate of 16 SWG M.S. Sheet with hinged door cover for mounting TV amplifier including wooden base plate complete as required.
SUBHEAD- III: M.V. PANELS/ DISTRIBUTION BOARD
SPN DB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
8 way , Double door
12 way , Double door
TPN DB
Supplying and fixing of following ways,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess ,complete with tinned copper bus bar, neutral link, earth bar, din bar,interconnections, powder painted including earthing etc. as required. ( But without MCB/RCCB/Isolator)
4 way Double door
6 way Double door
8 way Double door
VTPN DB
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs/MCCB and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way Double door
8 way Double door
12 way Double door
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
DP MCB as DB I/c
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
FP MCB as DB I/c
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
S & F 100 amp. FP MCCB (16KA) Thermal Magnetic Release
S & F 125 amp. FP MCCB (16KA) Thermal Magnetic Release
S & F 160 amp. FP MCCB (16KA) Thermal Magnetic Release
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .
Single pole
Triple pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG CRCA sheet steel, totally enclosed IP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 100mmx50mmx5mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switch gears
All MCCBs shall have Ics=Icu=100%
MCB Should be connected throught terminal Strip of suitable rating
All outgoing MCCB feeders shall have ON/OFF Trip indication lights (LED Type)
Panel Specification as stated above (Floor Panel)
Incomer
1 No. 250 A FP MCCB (36 KA)
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-250 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
315 Amps. TP&N aluminium bus bars (36 KA)
OUT GOINGS:-
4 Nos 63 Amp. FP MCB (25 KA)
3 Nos. 125 Amps. FP MCCB (25KA)
Panel Specification as stated above (Equipment Floor Panel For Third & Fourth Floor)
Incomer
1 No. 250 A FP MCCB (36 KA)
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-250 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
315 Amps. TP&N aluminium bus bars (36 KA)
OUT GOINGS:-
2 Nos 100 Amp. FP MCCB (25 KA)
6 Nos. 125 Amps. FP MCCB (25KA)
Panel Specification as stated above (Equipment Panel For First Basement,Fifth Sixth & Seventh Floor )
Incomer
1 No. 400 A FP MCCB (36 KA)
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-400 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
500 Amps. TP&N aluminium bus bars (36 KA)
OUT GOINGS:-
2 Nos 125 Amp. FP McCB (25 KA)
6 Nos. 160 Amps. FP MCCB (25KA)
Panel Specification as stated above (Main UPS Panel)
Incomer
2 No. 200 A FP MCCB (36 KA)
2 Set phase indication lights (R, Y, B)
2 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
2 No. 0-200 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
400 Amps. TP&N aluminium bus bars (36 KA)
OUT GOINGS:-
10 Nos. 160 Amps. FP MCCB (25KA)
Panel Specification as stated above (Lift Panel)
Incomer
1 Nos 250 Amps Automatic Change Over Switch
1 No. 250 A FP MCCB (36 KA)
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-250 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
400 Amps. TP&N aluminium bus bars (36 KA)
OUT GOINGS:-
6 Nos. 125 Amps. FP MCCB (25KA)
Sub Outgoing
6 Nos. 40 Amps. DP MCB (25KA)
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
Supplying, installation, testing & commisioning of following capacity Automatic Chage Over Switch with 2 incoming and 1 no outgoing with cable termination as per SLD use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated complete with necessary accessories including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
Supplying, installation, testing & commisioning of following capacity plugin/tapoff box for the existing Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
Supplying, installation, testing and commissioning of following ratings of MCCBs/ACB installed in sheet steel enclosure with indicating lamps etc., earthing, connections, as per specifications complete as required.
160/200 Amps FP MCCB
250 Amps FP MCCB
400 Amps FP MCCB
1000 Amps FP ACB
1250 Amps FP ACB
SUBHEAD - VI : EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
SUB-HEAD -V : LIGHTNING PROTECTION SYSTEM
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Supply and lying of 32mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect.
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
SUB-HEAD - VI : L.V. Cable
Supplying following 1.1kV grade, XLPE insulated, heavy duty armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, galvanised steel armouring and with all components as mentioned in BOQ, specifications, complete as required.
3.5 x 240 sq.mm
3.5 x 185 sq.mm
3.5 x 95 sq.mm
3.5 x 70 sq.mm
3.5 x 50 sq.mm
3.5 x 35 sq.mm
3.5 x 25 sq.mm
4 x 16 sq.mm
4 x 10 sq.mm
4 x 6 sq.mm
2 x 16 sq.mm
2 x 10 sq.mm
2 x 6 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 240 sq. mm
3½ X 185 sq. mm
3.5C X 95 Sqmm
3.5C X70 Sqmm
3.5C X50 Sqmm
3.5C X35 Sqmm
3.5C X25 Sqmm
4C X 16 Sqmm
4C X 10 Sqmm
4C X 6 Sqmm
2C x 16 sq.mm
2C x 10 sq.mm
2C x 6 sq.mm
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
100mm dia
150 mm dia.
250mm dia
Supply, laying, connecting, termination and testing of under noted sizes of flexible copper conductor flexible PVC sheathed & sleeved and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.
1 C x 70 sq.mm
1 C x 35 sq.mm
Supply, laying and testing of under noted sizes of copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.
4 x 6 sq.mm
4 x 4 sq.mm
4 x 2.5 sq.mm
Supply and making end termination with brass double compression gland including providing and crimping of copper solderless lugs / ferrules for XLPE armoured power copper conductor cable 1.1 KV grade of following sizes:-
4 x 6 sq.mm
4 x 4 sq.mm
4 x 2.5 sq.mm
Supply and fixing of cable tray/steel work in position including clamps, frame work of flats, angle iron, channel with fabrication work including cutting, bending, welding, drilling bolting etc. as per design as required. One coat of primer and 2 coats of enamel paint of approved shade shall be provided.
Supply and fixing of perforated 2mm thick CRCA sheet steel power coated cable tray of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. including providing and fixing of M.S. painted hanger etc. as required.
150mm wide 50 mm depth
300mm wide 62.5mm depth
450mm wide 62.5mm depth
600mm wide 75mm depth
INTELLIGENT FIRE ALARM SYSTEM
Ten Loop Panel.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.(For automatic door closers, elevator controls, fire suppression systems, smoke ejectors etc)
Supplying, installation, testing & commissioning of addressable fire monitor module complete as required.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
PUBLIC ADDRESS SYSTEM
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Cabling and Wiring
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
speaker cable Single pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25mm dia conduit
32mm dia conduit
SUBHEAD-I INTERNAL FIRE HYDRANT & SPRINKLER SYSTEM
Note:- 1.NOC from fire authority shall be in the scope of Contractor . Only fee paid to the fire authority shall be reimbursed against the submission of the receipt and nothing shall be paid extra. 2. All the Fire Fighting works shall be done in compliance of Fire Fighting authority requirement.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing flow switch in following sizes M.S.pipe including connection etc as required.
100mm dia
Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80 mm dia
100 mm dia
150 mm dia
Fire Hydrant Valve, Double headed, Gunmetal, IS:318-LTB2 Grade, 100mm N.B Flanged inlet, Brass Spindle, 02 individually controlled 63mm Female Instantaneous Oblique Outlet, Complete with PVC Blank Cap & GI Chain, Bearing IS:5290 Mark, Flange O.D.220mm, PCD 180mm, Eight 19mm Dia Holes
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Gun metal
Fireman Axe-made of carbon steel with rubber insulated handle tested to 20,000 Volts as per IS:926 Make: NEWAGE
Fire shaft door fabricated out of M.S. sheet and frame, door size of 1200 (W) x 2100 (h) with 4 mm thick glass, suitable Rubber beading and Locking arrangement and complete door shall be powder coated with red color powder coating
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Upright Sprinkler
Horizontal side wall sprinkler
ABC Powder & Clean Agent Based Standalone (Modular) Fire Suppression Systems for LAB
SUBHEAD-II : FIRE EXTINGUSHER
Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:
Co2 type Fire Extinguisher 4.5 Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and wheel type valve with initial Charge as per IS: 15683:2018 specification, bearing ISI Mark & EIL approved.
Co2 type Fire Extinguisher 6.5Kgs. Capacity, made from brand new seamless steel cylinder, as per IS: 7285 and CCE approval fitted with discharge, hose and horn with wheel type valve mounted on trolley wheels with initial charge as per IS: 16018 : 2012 specification, bearing ISI Mark & EIL approved.
Co2 type Fire Extinguisher 9 Kgs. Capacity, made from brand new seamless steel cylinder, as per IS: 7285 and CCE approval fitted with discharge, hose and horn with wheel type valve mounted on trolley wheels with initial charge as per IS: 16018 : 2012 specification, bearing ISI Mark & EIL approved
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.
CIVIL WORKS (PUMP,ESS & GUARD ROOM)
EARTH WORKS
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Carriage of material by mechanical transport including loading, unloading to 5km.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level:
As in item (279) above but in the proportion of 8:4:1
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform.
Shelves (Cast in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts.
Weather shade, Chajjas, corbels etc., including edges
Edges of slabs and breaks in floors and walls
Under 20 cm wide
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Extra for providing richer mixes at all floor levels.
Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/Cum).
Add for using extra cement in the items of design mix over and above the specified cement content therein.
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay (non modular) bricks of class- 150 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement : 3 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
MARBLE & GRANITE WORK
Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
WOOD & PVC WORK
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Single rubber stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows, Doors and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading
STEEL WORK
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Providing and fixing ball bearing for rolling shutters
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes
4.0 mm thick glass panes
5.5 mm thick glass panes
FLOORING & CLADDING WORK
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete
40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
ROOFING
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
FINISHING WORK
12 mm cement plaster in single coat on fair side of single or half brick wall for interrior plastering includign arises, interior rounded angles chamfers and of rounded angles not exceeding 80 mm in girth and finished even and smooth.
1:4 (1 cement: 4 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix:
1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level:
In two coats
Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
WATER PROOFING
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-chargeover 20 mm thick layer of cement mortar of mix 1:5 (1 cement:5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mmsquare 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
Description of Work / Item(s)
Amount
External Development works
U G TANK
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil
BELOW GROUND 1.5 TO 3.00 M
PCC WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
RCC WORK
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works above plinth level upto floor V level
SHUTTERING WORK
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
REINFORCEMENT STEEL WORK
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
230 MM BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
MS WORK
Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
FLOORING \ CLADDING
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
PLASTER WORK
12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand) ON INNER SURFACE
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) External plaster
PAINTING WORK
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
WATER PROOFING
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
RCC ROAD
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone aggregate 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction / expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-incharge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing in position pre-moulded joint filler in expansion joints.
Providing and laying in position bitumen hot sealing compound for expansion joints etc.
Using grade 'A' sealing compound.
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-incharge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete.
New work (Two or more coats)
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D- 4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Back side of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer--in-charge.
Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
PathWay Road Side
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix : 1 cement: 6 C. sand.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
HORTICULTURE & LANDSCAPING
Supplying and stacking of good earth at site including royalty and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment)
Screened through sieve of I.S. designation 20mm
Mixing earth and sludge or manure in proportion specified or directed.
In rows 5 cm apart in either direction.
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, with in a lead of 50 m, lift upto 1.5 m complete.
Providing and fixing M.S flat iron tree guard 6 cm dia and 2 m high, above ground consisting 4 nos 25X6 mm, 2.25 m long and 8 nos 25X3 mm 2m long verticals M.S flats, riverted to 3 nos 25X 6 mm M.S flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia and 30 mm long bolts, including painting twocoats with synthetic enemal paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250X100 mm shall be welded to the tree guard near the middle height and lettered CPWD/PWD/any other approved name. The tree guard shall be suitably fixed to the ground by embedding four les of tree guard in pits of suitrable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisaction and direction of officer-n-charge.
Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. All kinds of soil
Providing and Displaying Ficus black vivion piller Topairy (sylinder type) well developed with fresh & healthy 180 to 210 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Ficus Nuda Topairy well developed with fresh & healthy 5 to 6 big ball specific size and shape 180to 210cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Ficus resnold Topairy well developed with fresh & healthy 6 to 7 big ball specific size 210 to 240 cm ht in 45 cm Cement Pot as per direction of the officer-incharge.
Detail of tree
Raphis palm 3' - 4' height
Foxtail palm 8' - 10' height
Tabebuia 2'-3' ht
Palm cycas Revolura 2"-3" dia
Golden duranta ( hedge )
Toparies height 5 - 6 ' height
Golden bottle brush
Casurina
Ficus Resonalt
Areca palm 4' - 5' height
Draceana varieties
Croton varities
Deffenbachia
Aglonema
Money plant with moss stick 3' height
Syngonium with moss stick 3' height
Oxycodium with moss stick 3' height
Fishtail palm
Champagne palm 1 - 2 m folliage
Anar (30) 2-7 m folliage
Chiku (24) 3 -8m folliage
Mango (24) 3 -8m folliage
SHRUS (have several woody item)
Coral Hibiscus 2'-3' ht
Massanda Pink 2'-3' ht
Kachnar 5'-6' ht
Bottle Brush 5'-6' ht
Ixora 2'-3' ht
Ficus black Tapori 3'-4' ht
Ficus Prestige Boll 3'-4' ht
Hamelia 2'-3' ht
Ground edging Plant
Eranthemum
Verbena
Setcreasea
Verbena Mix
SS planter 18'' dia
Electrical Lawn mover power Grass cutter & power weed shear
Supplying and fixing Vertical garden ( Wall) along with drip irrigation system, fixation of frame work along with material & painting, planters, manure, fertilizer, soil mixing, supply of plants filling and plantation complete in all respect.
CONSTRUCTION OF BOUNDRY WALL
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Cornices and mouldings
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Class-150 brick work in 1:6 cement and COARSE sand mortar in SUPERSTRUCTURE including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work
12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering upto floor two level including internal rounded angles not exceeding 80mm in girth and finished even and smooth (i) 1 cement: 6 coarse sand
Providing and fixing sheet covering over expansion joints with iron screws as per design.
Aluminium fluted strips 3.15 mm thick. 200 mm wide
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
CONSTRUCTION OF ENTRANCE GATE
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Cornices and mouldings
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 40 MM THICK
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Class-150 brick work in 1:6 cement and COARSE sand mortar in SUPERSTRUCTURE including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work
GROUND FLOOR
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) External plaster
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
COST FOR CATTLE CATCHER
Excavation in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth as directed by the engineer I/C within a lead of 30 m.from foundation trenches.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Rolled Steel Beam Designation ISHB 200
Hold fast (40X40X6 MM)
Angle
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete
40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore.
CONSTRUCTION FOR WATER BODY CIVIL WORKS
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soils
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge
Providing and laying Ceramic floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, expect White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1: 4 (1 Cement : 4 Coarse sand ) including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Using rough kota stone.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
Using rough Kota stone
COST OF EXTERNAL SEWERAGE WORKS
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
1.50 m depth
Pipes 80 mm to 300 mm diameter
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
Depth not exceeding 1.5 meter
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
250 mm. dia. RCC Pipes
Providing and fixing in floor and wall face Ringfit chempro ASTRAL ULTRADRAIN Conventional system for lab sink waste water pipes
150mm. dia.
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
150mm. dia.
Providing and fixing on wall face chempro fittings/accessories for chempro pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. (Make : Astral (HSN Code 39174000)
150dia chempro Coupler (HSN Code 39174000)
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
250 mm. dia.
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
With common burnt clay FPS (non modular) bricks of class designation 75
(i) For Sewer Line
Extra for depth for manholes:
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).
With common burnt clay FPS (non modular) bricks of class designation 75
(i) For Sewer Line
Extra for depth for manholes:
Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29m
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
COST OF EXTERNAL WATER SUPPLY SYSTEM WORKS
RISING MAIN AND BYE PASS ARRANGEMENT
Providing and laying double flanged (Screwed/Welded) centrifugally (Spun) Ductile iron pipes of class K-9 conforming to IS 8329
100mm dia Ductile iron double flanged
Supply CI specials such as Bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete. (10 % of Previous item)
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,
in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
a) Pipes 80mm to 300mm diameter.
Providing push-on-joints to centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket :
100mm dia pipes
Providing and fixing C.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately):
100mm diameter
Provding and fixing C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately.
a) 80mm dia
DISTRIBUTION SYSTEM
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)
25mm nominal bore.
32mm nominal bore.
40mm nominal bore.
50mm nominal bore.
65mm nominal bore.
80mm nominal bore.
Supplying and fixing of specials for pressure pipe.
10% of Previous item
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
25mm nominal bore.
32mm nominal bore.
40mm nominal bore.
50mm nominal bore.
65mm nominal bore.
80mm nominal bore.
Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design
Water Transfer Pumps (Hydropneumatic systems)
1-nos, vertical stainless steel in-line pumps having stainless steel casing, stainless steel pump foot diffusers, stainless steel impellers, ceramic bearing, tungsten carbide shaft protection bushes and mechanical seal driven by appx 25.0 hp ,415volts 50 cycles, AC 3 phase TEFC vertical flange motor motor. Each pump shall be capable of delivering 12.0 lps @ 100 mtr head. With complete headers, fittings & foundation as per Specifications
RAIN WATER DRAINAGE NETWORK
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
up to 1.50 m depth
Pipes 80 mm to 300 mm diameter
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
150 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
150 mm. dia.
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
With common burnt clay FPS (non modular) bricks of class designation 75
(i) For Sewer Line
Extra for depth for manholes:
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
S.T.P. & E.T.P
SEWAGE TREATMENT PLANT + EFFLUENT TRAETMENT PLANT (20+10 KLD CAPACITY) 1. POLLUTED WATER CHARACTERISTICS Medical College Polluted water Raw Polluted water Generation & Characteristics for Designing of the WPCES: Average Daily flow (Cum/day) 20 Hourly flow (Cum/Hr.) 16.6 (Average Load) 24 hr. HRT
EQUIPMENT SPECIFICATION FOR STP The basic system comes with the following standard equipment Two sets of Screen. Two sets of Blower &motor for air blowing in bioreactor for oxygen to bacteria & motor. Two sets of centrifugal pump. Two sets of Sludge pump. Two sets of filter feed pump. Two sets of sludge recycling pump PSF (Pressure sand filter) & ACF( Activated carbon filter) Piping & valves. MBBR (Moving Bed Biofilm Reactor) media Tube deck media. Wire & cables. Bubble diffuser. One main electrical switchboard/control panel for supplying power to various pumps of the system.
RAIN WATER HARVESTING
RECHARGE PITS
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
In all kind of soil upto 3.0m to 4.5m. depth
In all kind of soil upto 4.5 m to 6.0m. depth
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
12 mm cement plaster of mix :
1:4 (1 cement: 4 coarse sand)
Centering and shuttering including strutting, propping etc. and remova of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
With 20x20mm square bar
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
M.D. -10- Circular shape 500mm internal diameter
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
Drilling of 300mm dia bore hole manually.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
DESILTING CHAMBER
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
12 mm cement plaster of mix :
1:4 (1 cement: 4 coarse sand)
Centering and shuttering including strutting, propping etc. and remova of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
With 20x20mm square bar
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
M.D. -10- Circular shape 500mm internal diameter
EXTERNAL DRAIN WORKS
Constructing brick masonry open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:
Drain 450 wide average. Depth 600 cm with R.C.C. Slab
Size :- Length = 1.50 M. Width =1.50 M Total Depth =1.50M
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and remova of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Providing and fixing gun metal non- return valve of approved quality
65 mm nominal bore
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
65mm dia
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
65mm dia
Kirloskar make sump pump Model 2200CW, 5 HP, 3 Phase, delivery pipe size 65 mm,
2 Nos of BORE WELL INSTALLATIONS
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
All types of soil
350 mm dia
Rocky strata including Boulders
350 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (RMS) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
150mm nominal size dia
`Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia having minimum wall thickness 5.00 mm.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
150 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Supplying & Installation of suitable Hp submersible pump B.S or K.S.B or equivalent make with finolex cable 1x3x2.5 squmm(upto 75mtr) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as MCB of 0-25Amp (Havell or Indocopp or MDS make), Volt & Ampere meter (AE make), single phase preventer (Minilac or VSP -1 make) starter (L&T or BCH make) etc of approved make, 40mm HDPE Pipe (25 mtr) and all accessories complete as per requirement of site.
NOTES
a) Contractor shall include the rate of electrical control panels complete with all accessories &controls, all Electrical/Mechanical items as required to operate the system automatic/manual.
c) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of water supply pumps, Submersible Sump Pumps, to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided.Domestic water pumps must start at low water level in overhead domestic water tank & stop at high level in that water tank. Dry running protection shall be provided for all the pumps.Sequencing shall be provided for each set of pumps.
Description of Work / Item(s)
Amount
UPS SYSTEM
Supply, installation, testing & commissioning of the following: IGBT based 60 KVA parallel True Online Double Conversion UPS suitable for unbalanced, 3 Phase input and 3 phase 415 V output UPS system with isolation transformer (i.e., K-13 type), suitable for operating in parallel and each comprising as per technical specification complete as required.
VRLA sealed maintenance free batteries for 60 KVA UPS system, for providing 30 minutes back up to each 60 KVA UPS. Each bank of batteries shall comprise required Nos. of SMF batteries etc as per specifications as required. INCLUDED IN ABOVE
Matching cabinet to house SMF batteries for 60 KVA UPS system along with interconnecting links and I/c S/F MCCB as required. INCLUDED IN ABOVE
Supply,Installation,testing Commissioning of Below described lifts complete as per specification and as per direction of Engg-In Charge
Passanger
16 P (1088 KG) (With m/c Room) Lift with speed of 1.5 M/Sec., travel of ground to seventh:8Stop/8 Open,power operated doors, ACVVVF Control, and automatic rescue operation during power failure. (dimensions and travelling as per drawing)
26 P (1768 KG) (With m/c Room) Lift with speed of 1.5 M/Sec., travel of Second Basement to seventh:10Stop/10 Open,power operated doors, ACVVVF Control, and automatic rescue operation during power failure. (dimensions and travelling as per drawing)
26 P (1768 KG) (With m/c Room) Lift with speed of 1.5 M/Sec., travel of ground to seventh:8Stop/8 Open,power operated doors, ACVVVF Control, and automatic rescue operation during power failure. (dimensions and travelling as per drawing)
SUBSTATION WORK
L.V. PANEL BOARD
MAIN LT Panel
Supply, erection, testing & commissioning of IP -42 cubicle type Panel fabricated (folded joints construction) out of 14 SWG CRCA sheet steel floor mounted totally enclosed extendable on both sides switchboard of uniform width with top cable entry and suitable for use on 415 V, 3 phase 4 wire 50 c/s having 65 KA fault capacity complete and housed with incomming and outgoing aluminium bus-bars,interconnection between feeders etc. and their accessories including supply and fixing of base channels of 100x50x6mm as required with provision for following incoming and outgoing switchgear with protection, metering etc. and terminals for scheduled cables and also compataible to PC/PLC/BMS with communiction port RS-485, complete as required and as per specification and schematic diagram complete as required. confirming IS 61439
Note-1) DESIGN, TESTING & CERTIFICATION OF LT MAIN PANEL's MUST COMPLY IEC-61439, ALONG WITH IEC-61641 FOR INTERNAL ARC FLASH
2) PROVISION OF BUSDUCT/CABLE MUST BE AS PER SLD.
The incoming of Transformer feeders & DG feeders as shown on drawing shall be connected through bus duct. The suitable adopter box shall be provided on top only and Solar Incommer through cable from bottom.
All Intelligent ACB shall have Micro processor based O/C, S/C & E/F release RS485 on board communication port. The release setting of all ACB's shall be possible from communication & also user can see the energy parameter of release from BMS/SCADA/Webpage and display module/HMI shall be provided on panel for each ACB to see the release data of ACB. All ACB's shall have Ics=Icu=Icw=65KA for 1Sec & should be supplied with Adopter Terminal Connections whose orientation can be changed on site.
All Intelligent MCCB shall have Micro processor based release with RS485 on board communication port, the release setting of all MCCB shall be possible from communication & user can see the release from BMS/SCADA/Webpage and a indication shall be provided on panel for each MCCB . All CTs and PTs shall be cast resin type. All MCCB shall have Ics = 100% Icu & should have Isolation Feature & Class II Front Face as standard.
All Intelligent ACB'S shall have spare wired contacts for ON,OFF,Trip,rackin,rackout spring charge status for BMS/SCADA communication along with LCD display.
All Intelligent MCCB shall be motorised with Microprocessor based release having spare wired contacts for monitoring ON/OFF and Trip shall be provided for SCADA communication. Control: ON & OFF.
TVM Shall have RS 485 Modbus RTU on board Communication protocol for SCADA communication.
All outgoing feeders shall have touch display module/HMI with RS-485 ports
Night mode and day mode for APFC CT in the transformer incomer.
The LT Panel manufacturer shall provide necessary,CT's Aux. contacts; multiply those contacts in the respective panels etc. to hook up in to PLC system
INCOMING
1 No. 3200 A, 50KA FP, draw out type electrically operated air circuit breaker with 230 V A.C. spring charged motor and micro processor based O/C, S/C & E/F releases, with communication port through RS-485 compatible with PLC/PC/BMS etc
1 No. 24 volt D.C.Shunt release
1 No. 230 volt A.C.closing coil
1 No. 415 volt A.C. under voltage release.
1 No. 3200 Amp. Ammeter (digital type) with inbuilt ASS
1 Set of CTs 3200 A/ 5A class-1 for metering
1 No.Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No.P.F. meter (digital type)
1 No.KWH meter (digital type)
1 No. C.T.3200/2500/1600/5 / 5A Class-1 for Capacitor panel.
Under Voltage relay 415 V A.C.
Over Voltage relay 415 V A.C.
O/C, S/C, and E/F relay
Breaker control switch
1 Set of phase indication lights R,Y,B.
1set of ON-OFF-TRIP ckt. Healthy. indication lights
Spring charged indication.
D.G. PANEL INCOMERS[2 Nos.750 KVA]
1 No. 1250 A, 50KA FP, draw out type electrically operated air circuit breaker with 230 V A.C. spring charged motor and micro processor based O/C, S/C & E/F releases, with communication port through RS-485 compatible with PLC/PC/BMS etc
1 No. 24 volt D.C.Shunt release
1 No. 230 volt A.C.closing coil
1 No. 415 volt A.C. under voltage release.
1 Set of CTs 1250 A/ 5A class-1 for metering
Digital Tri-Vector meter with KVAR, KW, KWH, PF, Ampere, Volts, Frequency metering
Battery charger 230 V/ 24 V DC, 20 A with DC ammeter and DC voltmeter. Charger should have all basic protections like over load, over Voltage reverse polarity etc.
Under Voltage relay 415 V A.C.
Over Voltage relay 415 V A.C.
O/C, S/C, and E/F relay
Restricted Earth Fault relay
Three phase differential relay
Trip circuit supervision relay
Auxillary relay
Master trip relay
Breaker control switch
Automatic load supervision relay
1 Set of phase indication lights R,Y,B.
1set of ON-OFF-TRIP ckt. Healthy. indication lights
Spring charged indication.
SOLAR POWER PLANT INCOMERS [1 Nos.] shall be equipped as: (100 KWp)
1 Nos.400 A FP MCCB , 50 KA, with M.R.,O/C, S/C & E/F releases & indicating lamps (R.Y.B. Phase indication with ON/OFF & Trip Indication) & ammeter and volt meter with all functions with set of CTs etc
1 No. Ammeter (digital type) with inbuilt ASS
1 No.Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No.8 step A.P.F.C.Relay (intelligent micro-processor based with current sensitivity less than 1%)
3 Nos. CTs- 400/5 Amps. Class -1.0
1 Set phase indication lights (R, Y, B)
BUS BARS:-
3200 Amps. 4P aluminium bus bars (50 KA)
BUS COUPLER:-
1 No. 3200A ,4POLE ,EDO ACB with 230 V A.C. spring charged motor.
1 sets Breaker Control switch
1 Sets of phase indication lights R,Y,B.
1 sets of ON-OFF-TRIP ckt. Healthy. indication lights
Interlocking: Transformer incomers ,DG Panel Incommers,solar PV Plant Incomers and bus couplers shall be electrically and mechanically interlocked so that no different source can be paralled at any point of time.
OUTGOINGS:-
2 Nos.630 A FP MCCB , 50KA, with M.R.,O/C, S/C & E/F releases & indicating lamps (R.Y.B. Phase indication with ON/OFF & Trip Indication) & Multifunction meter with all functions with set of CTs etc.
2 Nos.400 A FP MCCB , 50KA, with M.R.,O/C, S/C & E/F releases & indicating lamps (R.Y.B. Phase indication with ON/OFF & Trip Indication) & Multifunction meter with all functions with set of CTs etc.
2 Nos.250 A FP MCCB , 50KA, with M.R.,O/C, S/C & E/F releases & indicating lamps (R.Y.B. Phase indication with ON/OFF & Trip Indication) & Multifunction meter with all functions with set of CTs etc.
4 Nos.200 A FP MCCB , 50KA, with M.R.,O/C, S/C & E/F releases & indicating lamps (R.Y.B. Phase indication with ON/OFF & Trip Indication) & Multifunction meter with all functions with set of CTs etc.
PLC SYSTEM
PLC Operations
PLC system for Auto mains failure, Auto Load Sharing Management, with Auto Synchronization (For 2 Nos Transformer + 2 Nos.DG Sets + 1 No. Solar Power Panel )
2 Nos. no volt monitors for DG supply
2 Nos. no volt monitors for main supply
1 Nos. no volt monitors for Ongrid Solar Power supply
1 No. PLC Comprising:
PLC (Allen Bradley/ siemens)
5 Nos. Power monitors
PLC rack
Digital input modes
Digital Output modes
EPROM (EP)
Man Machine interface (MMI)
Grafix Software for PLC
1 set mimic (SEM)
Set of Auxiliary relays
Set of indicating lights and push buttons
set of control MCBs
Communication cable from PLC to computer as per requirement
1 No. Auto-manual-semi auto & test switches
1 No. status indicator
UPS for required operation
1 No. Auxiliary transformer (star/star)
1 No. printer A3 size
PC as per specifications ( Refer list of makes of materials)
Metering
Power & Energy monitor model (EM 6400 with RS- 238/485 port accuracy class 0.5)
Visual Indications & Control
1 set running
1 No. Emergency stop push button
1 No. Breaker close push button
1 No. Breaker trip push button
Annunciation
Annunciator with hooter, test, accept and reset Push button & Annunciate
Annunciator Inscriptions:
Solid state Annunciator ( 2 Nos. DG sets) for DG-1/ DG-2
Inscription:
Electrical Fault
Excitation Failure
Reverse Power
Emergency Shutdown
Over speed
Low Lube oil pressure
High water temperature
Engine overheating
Bearing temperature high
Winding temperature high
Low fuel level
Exhaust quality
Spare
Spare
Spare
Spare
Solid state Annunciator (1 No.) for ASP
Inscription
DG-1 Fails to Start
DG-1 Neutral Discrepancy
DG-1 ACB Fails to Close
DG-2 Fails to Start
DG-2 Neutral Discrepancy
DG-2 ACB Fails to Close
Annunciator shall have facility for PC interface
Status indicator Annunciator ( 1No.) for ASP
DG-1 Supply Available
DG-1 ACB connected to Bus
DG-1 Neutral ON
DG-2 Supply Available
DG-2 ACB connected to Bus
DG-2 Neutral ON
BC - ACB ON
System operation:
The emergency Diesel -Alternator sets will function as follows:
DG SUPPLY : 2 NOS
MAINS SUPPLY : 2 NOS.
BUS COUPLER : 1 NOS
Manual Mode:
Two different source / supply can’t be paralleled as interlocking is Provided between all the incomers and Bus Couplers in both Auto/Manual mode.
PLC on manual mode:
When all Grid supply available, breaker of all mains shall be switched ON with B/C in off position, all sections of bus bar will be fed through Grid supply.
On Grid failure all mains breaker will get tripped and depending on the load demand any one of the DG can be started and respective DG Breaker along with bus-coupler can be switched ‘ON’ to charge the complete Bus manually. However D.G. can be started automatically if it is in Auto Mode.
We can run one D.G. and one mains supply (but not on the same bus) with bus coupler in off position or Vice-Versa.
No time delay shall be applicable in Manual Mode for closing and tripping of air ckt. Breaker.
Auto Mode:
Grid Supply Healthy:
When all mains supply available, breaker of all mains shall be switched ON with B/C in off position, all sections of bus bar will be fed through Grid supply.
On Grid Failure:
Option – 1
DG 1 in auto mode, rest of D.G.s in manual or in off mode. As Soon as Grid fails DG1 will be started automatically. Healthiness of the DG1 voltage will be sensed by PLC through Under Voltage Relay provided in DG incomer and closing command will be given by PLC to DG1 incomer Breaker and B/C will have time delay of 10 seconds, will be closed so that complete load will be feed through DG1 and similarly in case with DG2
Option – 2
DG1 & DG2 in Auto mode and other DG sets are Manual or in off Mode In this case both the DG sets will start as soon as grid fails. After attaining proper Voltage PLC will give closing command to DG1, DG2 and bus coupler will get tripped. If either of DG fails to start than in-between bus coupler will get closed to charge the complete bus through single DG set. Further if faulty DG becomes healthy and comes in line than in-between bus coupler will get tripped and DG breaker will get closed.
Option – 3
If all D.G.s are in Auto mode then the bus coupler will be in ON position and the DG will get Start one by one as per the priority set as per the load conditions.
If load on DG exceeds 80% of its full load after 10 sec. of time delay in order to check load consistency, the next DG which is in auto mode and healthy condition will start automatically bus coupler will get tripped through PLC and DG breaker of new DG will get closed.
On mains restoration of (45 seconds stabilized) supply all DG Breaker will gets tripped and Mains breaker will get closed. B/C will get closed with time delay say of 10 seconds. On further failure of Grid supply same sequence of operation will be followed as above.
APFC PANEL
Supplying, installation, testing and commissioning of free standing, front operated cubical type capacitor control panel with aluminium bus bars of current density 0.8Amps/sq.mm.& rupturing capacity(50KA), LED indicating lamps interconnections with under noted switch gears as per technical specifications and drawings complete as required. All MCCB shall have rotary operating handles. (capacitor control panel)
Note-1) DESIGN, TESTING & CERTIFICATION OF PCC PANEL's MUST COMPLY IEC-61439, ALONG WITH IEC-61641 FOR INTERNAL ARC FLASH
660 kvar capacitor control panel
1 No.1250A ,TPN ,50KA,MDO ACB with releases for O/C,S/C&E/F.protection..
1 No. Ammeter (digital type) with inbuilt ASS
1 No.Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No.12 step A.P.F.C.Relay (intelligent micro-processor based with current sensitivity less than 1%)
3 Nos. CTs- 1250/5 Amps. Cl-1
1 Set phase indication lights (R, Y, B)
1250 Amps. TP&N aluminium bus bars (50 KA)
3 No.200Amps. TPN MCCB(50 KA) with electronic releases.
8 No.100 Amps. TPN MCCB(50 KA) with electronic releases.
2 No. 120 KVAR TP Shunt capacitor Heavy duty MPP type with discharge resistor and 7% D-tuned Harmonic reactor filter
7 No. 60 KVAR TP Shunt capacitor Heavy duty MPP type with discharge resistor and 7% D-tuned Harmonic reactor filter
2 No.240 Amps. TP capacitor duty contactors.
7 No. 120 Amps. TP capacitor duty contactors.
12 Sets self illuminated Red-Green ON-OFF push buttons. 2 Sets of Axial flow fans with thermostate.
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity outdoor type IP-65, Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with oudoor 1.2 mm GI sheet canopy, 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, fire barrier, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required(IP 65)
3200 amps 50 KA SC for 1 sec
1250 amps 50KA SC for 1 sec
Supply and installation of MS Support structure for busduct and cabling work complete in all respect along with duly coated with two coats of red-oxide primer and two coats of enamel paint. The colour shade of final paint will be as decided by the client.
L.V. CABLES
Supplying following 1.1kV grade, XLPE insulated, heavy duty armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, galvanised steel armouring and with all components as mentioned in BOQ, specifications, complete as required.
3.5 x 400 sq.mm
3.5 x 300 sq.mm
3.5 x 240 sq.mm
3.5 x 185 sq.mm
3.5 x 150 sq.mm
3.5 x 120 sq.mm
3.5 x 95 sq.mm
3.5 x 70 sq.mm
3.5 x 50 sq.mm
3.5 x 35 sq.mm
3.5 x 25 sq.mm
4 x 16 sq.mm
4 x 10 sq.mm
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
100mm dia
150 mm dia.
250mm dia
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:-
3.5 x 400 sq.mm
3.5 x 300 sq.mm
3.5 x 240 sq.mm
3.5 x 185 sq.mm
3.5 x 150 sq.mm
3.5 x 120 sq.mm
3.5 x 95 sq.mm
3.5 x 70 sq.mm
3.5 x 50 sq.mm
3.5 x 35 sq.mm
3.5 x 25 sq.mm
4 x 16 sq.mm
4 x 10 sq.mm
Supply, laying and testing of under noted sizes of copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.
4 x 6 sq.mm
4 x 4 sq.mm
4 x 2.5 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct or tray as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supply and making end termination with brass double compression gland including providing and crimping of copper solderless lugs / ferrules for XLPE armoured power copper conductor cable 1.1 KV grade of following sizes:-
4 x 6 sq.mm
4 x 4 sq.mm
4 x 2.5 sq.mm
Supplying, laying, connecting,terminating, testing & commissioning of under noted sizes of PVC insulated, PVC sheathed unarmoured and overall PVC sleeved 1.1 KV grade control cables in pipe, wall, racks, cable trays, including, dressing, clamping with M.S Zinc passivated clamps etc as required conforming to relevant IS code and technical specifications.
8C x 1.5 sq.mm
10C x 1.5 sq.mm
14C x 1.5 sq.mm
Supply and fixing of cable tray/steel work in position including clamps, frame work of flats, angle iron, channel with fabrication work including cutting, bending, welding, drilling bolting etc. as per design as required. One coat of primer and 2 coats of enamel paint of approved shade shall be provided.
Supply and fixing of perforated 2mm thick CRCA sheet steel power coated cable tray of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. including providing and fixing of M.S. painted hanger etc. as required.
300mm wide 62.5mm depth
450mm wide 62.5mm depth
600mm wide 75mm depth
900mm wide 75mm depth
Supplying and fixing ladder type prefabricated CRCA sheet steel Stove enameled cable tray complete with bend/tee joints, coupling plate and nut bolts washers etc. with side runner 20 x 100 x 2.5mm and centre rungs of size 15 x 30 x 2.5mm c/c 250mm. including providing and fixing of hangers etc. as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
SUB-HEAD -III: EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Control Cables
Supplying, Laying, terminating, testing, commissioning of following sizes of Copper Conductor PVC insulated, PVC sheathed armoured cable 1100 V grade. On surface the cable run shall be fixed on G.I. clamps etc of suitable size or as directed by the E-I-C complete in all respects. Supply and providing cable identification markers. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per specifications complete with end termination as required.
24 C x 2.5 Sqmm
4 C X 2.5 Sqmm
2 C X 2.5 Sqmm
2 C X 4.0 Sqmm
3CX6 Sqmm
Supplying, Laying, terminating, testing, commissioning of following sizes of Copper Conductor PVC insulated shielded , PVC sheathed armoured cable 1100 V grade. On surface the cable run shall be fixed on G.I. clamps etc of suitable size or as directed by the E-I-C complete in all respects. Supply and providing cable identification markers. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per specifications complete as required.
8 C X 0.75 Sqmm
TRANSFORMERS
Supplying, installation testing and commissioning of 1600 kVA, outdoor type, oil cooled, distribution transformer, suitable for 3 phase, 50HZ, AC supply, rated turn/voltage ratio of 11kV/0.433kV,Dyn 11 vector group, percentage impedence of 4.5%, oil immersed naturally cooled (ONAN) mechanism,core made of good quality CRGO, windings made of double wound copper, insulation class A,approved danger and arc flash signages and with all components as mentioned in BOQ, specifications and SLD & confirming IS 1180 Level-II losses, complete as required.
Cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side suitable for 11kV(E) 3C x 300 sqmm XLPE Cable
Bus Trunking Provision LV Side of Transformer as per SLD
Off load tap changer +5 to - 15 % in the steps of 1.25 with AVR
Bi directional rollers
Conservator with drain valve
Earthing terminals.
Explosion vent with double diaphragm and sight glass.
Radiator with top & bottom shut off valve.
First filling of oil including make up fill.
Silica gel breather with oil seal.
Rating and diagram plate.
Air release plug.
Buchholz relay with shut off valve.
Winding temperature indicator. (WTI)
Oil temperature indicator. (OTI)
Magenatic oil level gauge.
Pressure relief device.
Marshalling box with watertight lockable cover lid and all associated accessories as per schedules and specifications.
Drain cum bottom filter valve
Oil surge relay.
HT PANEL BOARD
A. Incomming Panel 1 Nos. each shall be comprising of:
1- Metal Clad housing with track having 1250A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -800/400/5A class 5P-10(15 VA)
CT- II –800/400//5A class -1(15 VA)
3 - Nos. PT's 11KV /Rt.3 /110V/Rt 3 of (100 VA) cast resin type.
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
B. Outgoing Panel 2 Nos. each shall be comprising of:
1- Metal Clad housing with track having 630A TP integral VCB with Electric operated draw out type mechanism (spring charged motor - 230 VAC).
1- Set of air insulated copper bus bar & chamber.
1- Set of isolating plug and receptacle.
1- Set of Automatic safety shutter.
1- Set of breaker control switch (TNC)
2- Sets of CT's
CT- I -200/100/5A class 5P-10(15 VA)
CT- II - 200/100/5A class -1(15 VA)
1 - H.T. Cable box for 3C x 300 sq.mm aluminium conductor XLPE cable (11 KV earthed system).
1 - No. Tripping coil & closing Coil 24V DC/110V A.C.
1 - Set of ON/OFF/Trip & circuit healthy and phase indicating lights.
1- 3 element O/C, EF & SC relay (IDMTL & Hi - set) with required setting.
1- set Auxiliary relay.
1- Master trip relay
1-set Trip circuit supervision
1-Restricted Earth fault relay
Supply, erection, testing & commissioning of 230 V, single phase, 2 wire, A.C. to 24V D.C. 180 AH sealed maintenance free batteries with semiconductor/ IGBT (half wave rectifier) with auto-manual trickle boost facility battery charging units complete including 1 No. Distribution board having 63 Amps DP MCB incomer and 12 No. 16/ 20 Amps DP MCBs (D.C. duty) as outgoing complete as required as per technical specifications.
Supplying and fixing of non-skid rubber mat 25mm thick and 900mm width as required including cutting to required lengths of approved make with Test Certificates for H.T. 11 KV panels.
Supplying and fixing of non-skid rubber mat 16mm thick and 900mm width as required including cutting to required lengths of approved make with Test Certificates for L.T. panels.
Supplying and fixing of fire bucket painted red and duly filled with sand conforming to IS: 2546-1974.
Supplying and fixing of MS stand suitable for supporting two buckets (Pedestal type)
Supplying and fixing of MS stand suitable for supporting four buckets (Pedestal type)
Supplying and fixing of shock restoration chart written in English and Hindi duly framed in as required.
Supplying and fixing of carbon dioxide fire extinguisher type 4 kgs. Capacity of approved make with wall mounting bracket as required conforming to IS: 2878/1976 (Push type).
Supplying and fixing of first aid box as approved complete with standard kit as prescribed by Indian Red Cross.
Supply and fixing of H.T. Danger notice plate of 250x200mm made of mild steel at least 2mm thick and vitreous enameled white on both side with inscription in signal red colour on front side as required.
D.P. Structure, H.T. Panel Board, Battery Charger & HT Metering Panel
Supply, erection, testing and commissioning of H Pole (double pole) structure in position 13M long MS pole (Swaged type) as per IS-410 SP-70 with latest amendment and necessary anti climbing devices, cross arms, bracing, clamps and painting with one coat of primer and two coats of aluminium paint including circuit marking etc. as required. The poles to be erected in cement concrete foundation of 1:2:4 with collar including excavation in soil (600mm(L) x 600mm(W) x 1800mm(D)) and making good complete as required.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supply, erection, testing and commissioning of 11 KV disc insulator for 33 KV over-head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required (9 Nos Set : 3 Nos for each phase)IS: 731-1963 and 3188-1965 for disc insulator.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supply, erection, testing and commissioning of 11 KV, 3 phase, 630 Amps central post racking type gang operated switch with earth switch complete with hardware, arcing horns, arcing contacts, vertical drop out fuses, down rod operating with locking devices, necessary MS channel/angle iron brackets, clamps insulators & connections etc. as required for earthed system and conforming to IS: 19813.
Supply, erection, testing and commissioning of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supply, erection, testing and commissioning of 25x5mm GI earth strip including clamps and binding etc. as required as per specifications and drawings.
Supplying and laying of the 250mm dia 'B' class GI pipe complete with all accessories as required as per specifications.
Supplying and fixing of 1200x1200x12mm GI plate, vertically earthing complete with 20mm dia GI pipe, a funnel for watering with hinged cover masonry housing alternate layer of coke and salt atleast 100mm thick all-around etc. complete as required confirming IS-3043
Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
3Cx300 Sq.mm.
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
3Cx300 Sq.mm.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
3Cx300 Sq.mm.
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
3Cx300Sq.mm.
External Street Light
EXTERNAL LIGHTING
Supplying, installation, testing and commissioning of L.T. panel fully compartmentalized cubical type sheet clad floor mounted totally enclosed , extensible on both sides, switch board suitable for use on 415 Volts 3-phase, 4 wire, 50 Hz system having required fault capacity, housed with incoming and outgoing, Aluminium bus bars with current rating of 0.8 Amp/sq.mm, interconnection etc. with indication lamps, accessories etc, as required as per specification and schematic diagram as required. (Street lighting Panel)
INCOMER:-
1 Nos.200 Amps. TPN MCCB(25 KA) with electronic releases.
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-200 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
200 Amps. TP&N Aluminium bus bars (25 KA)
OUT GOINGS:-
10 Nos. 63A TPN, MCB (10KA).
6 Nos. 24 Hr Timer Switch
6 Nos. 63A TPN contactor
Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect including connecting copper wiring.CAT-AAA
Supply & Erection of 3/4 meter long GI Decorative pole for above post top fitting with inbuilt junction box,MCB,sleeve in foundation and required wiring till fixture in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect including foundation and connecting copper wiring. CAT-AAA
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 140 to 150 Watt. Confirming to IP 66 Protection complete in all respects including connecting copper wiring (CAT- AAA)
Supply & fixing of 9mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and with inbuilt junction box with MCB,and wiring till fixture, sleeve in foundation,Required T&P completee in all respect.
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 70 to 90 Watt. Confirming to IP 65 protection complete in all respect including connecting copper wiring.CAT-AAA
Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
80 mm dia
100 mm dia
Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect including connecting copper wiring.CAT-AAA
D.G. SETS
Design, supply at site, installation, testing & commissioning of 3-phase, 415 volt, 1500 RPM, 50 HZ, Diesel generator set with prime rating capacity of 750 KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure , day tank, with PCC Panel,Adopter box with AL extended bus bar, battery, batter charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator, pcc based auto start & synchronization set, safeties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to IS:4722.Genset should be capable to take an average loading of minimum 85%. net output shall be designed @ 50 degree ambient .Synchronisation should be based on No Master Logic for system reliability . Any genset reaching rated RPM should automatically become master .AVR should be digital type AVR to provide fast response with respect to change in load , it should provide digital governing with digital isochronous synchronisation. To improve the reliability of the System , the synchronizing module should be part of Engine Controller . No external controller should be used for synchronising and shall not be accepted.Genset controller should have Weak Battery Monitoring system . The control system should test the battery each time the genset is signalled to start and indicate a warning if the battery is weak
Roof Top Solar Online grid Sytem
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
ELV SYSTEMS
IP CCTV SYSTEM
SITC of IP Dome Camera 4MP IR Dome Camera, Metal Housing, H.265+/H.265/H.264, Up to 2592x1520@25fps, Min. illumination Color: [email protected], Smart IR, IR Range: 30m, Built-in Mic, SD Card Slot, Reset Button, POE, IP67, IK10, 120dB WDR, Support tripwire and perimeter, ANR. BIS,CE,FCC,ROHS,UL/EN. etc all complete. Make: Pelco / Royalshield / Bosch / Axis
SITC of IP Bullet Camera 4MP IR Bullet Camera, Metal Housing, H.265+/H.265/H.264, Up to 2592x1520@25fps, Smart IR, IR Range: 50m, Built-in Mic, SD Card Slot, Reset Button, 120dB WDR, POE, IP67, 120dB WDR, Support tripwire and perimeter, ANR. BIS,CE,FCC,ROHS,UL/ENetc all complete. Make: Pelco / Royalshield / Bosch / Axis
SITC of IP PTZ Camera 2 MP -IP PTZ Camera 2 MP - IP Network 1/2.8" CMOS, Dual IR Cut Filter , 1920x1080:30fps, H.264/MJPEG Or better, Triple streams, AC24V/POE+, IP66, Micro SD card slot support up to 128GB, Alarm in/out 1/1, Audio in/out 1/1, -30-65℃, IP66, 33x optical zoom(4.6 ~ 152mm), IR range: up to 150m, 120dB WDR, IP66, 33X optical zoom, HLC,BLC,3D DNR, Smart functions-Auto Tracking, CE, FCC, Defog, Privacy mask, Up to 8 Pattern, Presets – 300 , PAN Range - 360° , 0.1°/s ~ 180°/s ,Tilt Range -–16° ~ 90° (auto flip) , 0.1° ~ 120°/s etc all complete. Certificate – BIS, CE, FCC, ROHS, UL/EN etc all complete. Make: Pelco / Royalshield / Bosch / Axis
SITC of NVR - H.265 8SATA 64ch NVR, H.265+ Compression, Support 64-ch input, Up to 12MP Resolution Recording, Incoming Bandwidth 320Mbps, Outgoing Bandwidth 320Mbps, HDMI and VGA independent outputs, HDMI Video output at up to 4K (3840 × 2160) resolution, 8 SATA interfaces for 8 HDDs, up to 10TB for each HDD, eSATA interface:- 1 SATA interface, 2xRJ45 self-adaptive 10/100/1000 Mbps network interfaces, VCA detection alarm is supported, Array Type:- JBOD, RAID0/1/5/6/10, 2xUSB 2.0, 1xUSB 3.0, serial Interface:- 2xRS-485, 1xRS-232, No.of Hard Disks 4TB for the calaculation of 1 month recording 2MP@25FPS as per all camera count, VMS should also be included if required etc. all complete. Make: Pelco / Royalshield / Bosch / Axis
SITC of MS Windows 2008 Server R2 x64, Intel i5 Xeon Quad Core processor, 8 GB RAM, 1TB HDD, 2GB Graphics Card. With CD/DVD player, Mouse and Keyboard etc all complete. Make: HP / Lenevo / Dell
SITC of 55" LCD narrow Bazel for Monitoring for each NVR Server etc. all complete. Make: Sony / Panasonic / Aaztec
Access Control System
Supply Installation Testing and Commissioning of Android based Multi Modal IRIS Recognition cum Fingerprint Terminal, with Fake Fingeprint Detection Technology, Real Time Auto Push Technology, 20,000 IRIS (1:N) / 2,00,000 IRIS (1:1) 50,000 Fingers (1:N) / 2,00,000 Fingers (1:1), 10 million Transaction & 20,000 Image Logs, Onboard Dual Camera with Auto Tilt Function, Communication: TCP/IP, Wiegand Out / IN, RS 485, SD Card, Wi-Fi (optional); Multi Class Card (EM+Mifare), User wise authentication modes, Built in Lock Control, Up to 25,000 lux illumination, UL Listed Power Supply etc all complete. Make: IRIS ID/ Virdi/ Crucial Trak
Supply Installation Testing and Commissioning of Web based Access Mgmt Software includes Multi-Location scalability, Real Time Monitoring, Terminal Employee Management, Biometrics Template Management, Employee Blacklisting, Duress Features, Fire Integration, Email / Alarm Management, Log Access Reports, Compatible with Ms-SQL Databases. License to support upto 50 devices, Users Capacity upto 2000. Make: IRIS ID/ Virdi/ Crucial Trak
Supply Installation Testing and Commissioning of Z4 Recessed Electromagnetic Locks for Sliding Doors. with holding forces up to 280kg etc. all complete. Make: ASSA ABLOY/Trimec/Von Duprin
Supply Installation Testing and Commissioning of IP based Reader Interface module. Supports 2 Door- 2 reader over weigend and 2 Door- 4 Reader over OSDP. Also works with PoE & PoE+ . UL294 Listed, FCC, CE, RoHS, NIST Certified Encryption. Make: IDCUBE-MERCURY/MAXXESS/MORPHO
Supply Installation Testing and Commissioning of Enclosure with UL Listed Power Supply for Controllers. Make: IDCUBE-MERCURY/MAXXESS/MORPHO/DDS
Supply Installation Testing and Commissioning of Iclass Smart card reader1. Operating Frequency: 13.56 MHz Contactless Smart Card reader Data Formats: Wigand, OSDP, Keypad Data Formats : Field configurable, 8-Bit Burst (default) and 26-Bit Wiegand, Certifications and Compliance: UL294/cUL (US), FCC, IC, CE,C-Tick, MIC, NCC Housing Material UL94 Polycarbonate. Make: IDCUBE-MERCURY/MAXXESS/MORPHO/DDS/HID
Supply Installation Testing and Commissioning of UL294 Listed Biometric device with inbuilt smart card reader CPU: ARM® Cortex™-A9 core 1GHz • Linux Operating System, Fake finger detection • Duress finger • FBI PIV IQS certified optical fingerprint senso. • Network/Communication: - Ethernet, RS485, USB,Integrated Smart Card Reader, Internal storage capacity: 512MB Flash, 512MB RAM, Operating conditions: - Temperature: -20°C to 55°C (-4°F to 131°F) - Humidity: 10% to 80% (non condensing). • Ingress protection: IP65 and • EMC/Safety standards: - CE, CB, FCC, BIS, UL294 , RoHS, REACh and WEEE compliant. Make: IDCUBE-MERCURY/MAXXESS/MORPHO/HID
Supply, Installation, Testing & Commissioning of Smart card Frequency Excitation (13.56 MHz) Mifare/I-class technology smart Card. Memory Type EEPROM,Complies with ISO/IEC standards for thickness. Lifetime Warranty Make: IDCUBE-MERCURY/MAXXESS/MORPHO/HID
Supply Installation Testing and Commissioning of Single Door Electro Magnetic Lock Approved,Monitored Single Leaf/Double Leaf Electromagnetic Lock with 600/1200 lbs holding force with dual Monitoring and tested for 45 min on fire door assemblies fire rating including necessary mounting brackets Standards: UL Listed or CE Certified. Make: ASSA ABLOY/Trimec/Von Duprin
Supply Installation Testing and Commissioning of Double Door Electro Magnetic Lock Approved,Monitored Single Leaf/Double Leaf Electromagnetic Lock with 600/1200 lbs holding force with dual Monitoring and tested for 45 min on fire door assemblies fire rating including necessary mounting brackets Standards: UL Listed or CE Certified . Make: ASSA ABLOY/Trimec/Von Duprin
Supply, Installation, Testing & Commissioning of Access Control System: Control Room Equipments: 3 x 1.5 sq mm multi-stranded power Cable (Quantity in running Meter) etc. all complete. Make: Finolex / Polycab/ Havells
Supply Installation Testing and Commissioning Touchless Request to Exit button with detection range from 4 to 12 cm , 0.1 million cycle tested , Make: ASSA ABLOY/Trimec/Von Duprin
Supply Installation Testing and Commissioning Emergency Door Release Button, Gree, Key Resettable, Double Pole Double Throw (DPDT), Make: ASSA ABLOY/Trimec/Von Duprin
Supply Installation Testing and CommissioningX- ray Screening Baggage/ Inspection System Multi Energy Imaging (4 color) Tunnel Size 500 x 300 mm can view Previous / next bag, Manual Image Archive, should have configurable image processing keys with Date & time display facility Search Indicator including Flat monitor panel with UPS should have Fixed zoom 64 x or more, equipment should have standard like TIP Approved EU CE EWSTP STAC Certification etc. all complete. Make- Rapiscan/ Astrophysics / Detec
Sub Head : IT Active Passive, Wi-Fi & IPEBAX System
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 7 Feet for Data as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 4 Feet for Data Jack Panel end as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of Cat-6A, 24 Port Jack Panel for data as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 4 Feet for Voice Jack Panel end as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of Cat-6A 24 Port Jack Panel for Voice Field as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of Cat-6A 24 Port Jack Panel for Voice Field & Resource as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of 15 U Wall Mount Rack as per given Specification etc. all complete. Make: Rittal / Valrack/ APW / Netrack
Supply, Installation, Testing & Commissioning of 300 Pair MDF Box with Mounting Frame as per given Specification etc. all complete. Make: NetRack / Krone / APW / Actassi
Supply, Installation, Testing & Commissioning of 10 Pair Krone Module as per given Specification etc. all complete. Make: NetRack / Krone / APW / Actassi
Supply, Installation, Testing & Commissioning of 25 Pair Riser cable as per given Specification etc. all complete. Make: Delton / Skyton / Actassi
Supply, Installation, Testing & Commissioning of 42 U Wall Mount Rack as per given Specification etc. all complete. Make: Rittal / Valrack/ APW/ Netrack
Supply, Installation, Testing & Commissioning of 6 Core Multi Mode Fiber ( Armored) Cable as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of 12 Port Fiber LIU Loaded with SC MM Coupler, as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of SC MM Pigtail (1.0 Mtr) as per given Specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of 2 port faceplate with Gang Box etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of LSZH Cat 6A-10G speed unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed/surface conduits/Raceways complete 305 Mtr. Roll as per specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of UTP Cat-6A Information Outlet for Data as per specification etc. all complete Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of UTP Cat-6A Information Outlet for Voice as per specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi
Supply, Installation, Testing & Commissioning of Layer 3 Distribution Switch 24 Port with 10G Fiberports 4 port QSFP 10/40 G support with option of SM,MM, Copper as per the given Specification etc. all complete. Make- Cisco / Juniper / Allied Telesis
Supply, Installation, Testing & Commissioning of Wireless LAN Controller which can control up to 50 APs Should have atleast 1 x MultiGigabit/ 10 gigabit Ethernet interface aloong with 4x100/1000 RJ45 Baste-T port should support 3000 concurrent user WLC should support L2 and L3 roaming for IPv4 and IPv6 clients as per the given Specification etc. all complete. Make- Cisco / Juniper / Allied Telesis
Supply, Installation, Testing & Commissioning of Layer 2 switch 24 port Non POE for Data Points 10/100/1000 1G support and 4 SFP Port 10G uplink as per the given Specification etc. all complete. Make- Cisco / Juniper / Allied Telesis
Supply, Installation, Testing & Commissioning of Layer 2 POE+ 24 Port switch 10/100/1000 1G support and 4 SFP Port 10G uplink requirement for CCTV , Wi-fi as per the given Specification etc. all complete. Make- Cisco / Juniper / Allied Telesis
Supply, Installation, Testing & Commissioning of Access point which can support the given Controller,support 2x2 MIMO for both 802.11ac and 802.11n client,Support data rate of 867 Mbps on 5ghzas per the given Specification etc. all complete. Make- Cisco / Juniper / Allied Telesis
Supply, Installation, Testing & Commissioning of Internet Firewall Firewall I/O 10/100/1000 , Gigabit SFP (8throughput), (HTTP/appmix) 2.1/2.1 Gbps , Threat Prevention throughput (HTTP/appmix) 1.0/1.2 Gbps , IPsec VPN throughput 1.6 Gbps , New sessions per second 13,000 , Max sessions 192,000 , 802.1Q VLAN tags per device/per interface: 4,094/4,094 Aggregate interfaces (802.3ad), LACP , NAT modes (IPv4): static IP, dynamic IP, dynamic IP and port (port address translation) , NAT64, NPTv6 , Modes: active/active, active/passive Failure detection: path monitoring, interface monitoring , Zero Touch Provisioning (ZTP)etc. all complete. Make- Extreme / Palo Alto/ Allied Telesis
Supply, Installation, Testing & Commissioning of 100% Non Blocking Fully Digital Integrated Services Digital Network (ISDN) Compatible Voice Over Internet Telephone(VoIP) ready 19" Rack mountable EPABX presently equiped with 04 ISDN PRI Trunk Lines (120 Channel), 16 IP Extension, 16 Digital Extension, 150 Analogue Extension, Expandable up to 500 Ports / Channels and other as per the given Specification etc. all complete. Make: Panasonic / Avaya / Alcatel Lucent/ Cisco
Supply, Installation, Testing & Commissioning of 24 Port Analouge Card etc. all complete. Make: Panasonic / Avaya / Alcatel Lucent
Supply, Installation, Testing & Commissioning of High End Digital Key Phone 6x24 Display with 24 Programmable Dual Color LED’s with 4 Feature Access Keys, multi-step Tilt angle adjustment, Navigator Key, backlit display, should have option to connect Blue Tooth etc. all complete. Make: Panasonic / Avaya / Alcatel Lucent
Supply, Installation, Testing & Commissioning of Low end DIgital Key Phone 1x16 Display with 8 Programmable Dual Color LED’s etc. all complete. Make: Panasonic / Avaya / Alcatel Lucent
Supply, Installation, Testing & Commissioning of Analog Phone With Speaker , Small Display etc. all complete. Make: Panasonic / Avaya / Alcatel Lucent
Audio Video System
SITC of DLP Solid state(Laser Phosphor) 11000 Lumens , 4K UHD Resolution, Illumination Life : 20000 hours. Contrast Ratio 200000:1,Inputs: HDMI, VGA ,DisplayPort, HDBaseT, with lens etc.complete with installation as per the site requirement. MAkes: Christie,NEC,Sonyetc all complete Make: Christie / NEC / Sony
SITC of 1 Chip DLP LASER Phosphor Multimedia Projection system having, 6500 Lumens, 20000 hours lamp life, WUXGA (1920 x 1200p) Native Resolution, Contrast Ratio 4000000:1, inputs: HDMI, DVI-D, , USB, alongwith Zoom Lens etc. complete Make: Christie / NEC / Sony
SITC of Motorized Projection Lift, Aluminium Tubular Motorized Lift with LVC, RF remote, Max Projector size it can take : 600 x 600 x 250 ( W X D X H), Carrying Weight Capacity : 20 kg, Drop : 1000 mm ( 1 Mts) etc all complete Make: Draper / Dalite / Aaztec
SITC of Mountiung arrangements for seminar room projector with all required accessories etc all complete
SITC of Motorized Projection Screen, Image Size: 226 inch diagonal, Fabric: Matt White, Aspect Ratio: 16:9, RF Remote Control etc all complete Make: Draper / Dalite / Aaztec
SITC of Motorized Projection Screen, Image Size: 123 inch diagonal, Fabric: Matt White, Aspect Ratio: 16:10, RF Remote Control etc all complete Make: Draper / Dalite / Aaztec
SITC of 86" Multi Touch Display Panel, 4K UHD (3840 x 2160p) Resolution, Backlight : Direct-lit LED, Brightness: 410 nits, Contrast ratio: 1200:1, Display Colors: min 10bit, integrated 10-point multi-touch capability, Input: 2 HDMI, DisplayPort, VGA, Audio In Output- Audio output, Built-in OPS Slot, Anti Glare Treatment, HDMI-CEC, 2 x 8W speakers etc all complete Make: Christie / NEC / Aaztec
SITC of 75" Professional Display Panel, 4K UHD (3840 x 2160 ) Resolution, Brightness 400 nits, Contrast ratio 1400:1, Display colors 10 bit, 1.07 billion, Viewing angle 178 degrees h/v, Inputs: 4 HDMI, DisplayPort, VGA, USB 2.0 & USB 3.0, RCA (L/R) line in, HDR10 support, 2 x 10W built-in speakers etc all complete Make: Christie / NEC / Aaztec
SITC of 65" Professional Display Panel, 4K UHD (3840 x 2160 ) Resolution, Brightness 400 nits, Contrast ratio 1400:1, Display colors 10 bit, 1.07 billion, Viewing angle 178 degrees h/v, Inputs: 4 HDMI, DisplayPort, VGA, USB 2.0 & USB 3.0, RCA (L/R) line in, HDR10 support, 2 x 10W built-in speakers etc all complete Make: Christie / NEC / Aaztec
SITC of 55" Professional Display Panel, 4K UHD (3840 x 2160 ) Resolution, Brightness 400 nits, Contrast ratio 1200:1, Display colors 10 bit, 1.07 billion, Viewing angle 178 degrees h/v, Inputs: 4 HDMI, DisplayPort, VGA, USB 2.0 & USB 3.0, RCA (L/R) line in, HDR10 support, 2 x 10W built-in speakers etc all complete Make: Christie / NEC / Aaztec
SITC of Wall mouting kit for above display panel, 55" to 86" panel with all required accessories etc all complete Make: Btech / NB / Chief
SITC of Ceiling mouting kit for above display panel, 55" to 86" panel with all required accessories etc all complete Make: Btech / NB / Chief
SITC of PTZ Camera with HDMI Output and USB, 1/2.8″ low-noise, HD CMOS Sensor, 10x optical zoom, Simultaneous video output over HDMI and USB, Up to 255 camera presets available, Supports VISCA, Pelco-D, and Pelco-P camera control protocols, TCP/IP, RS-232, USB, and IR control with mounting etc all complete Make: Atlona / Clearone / Vaddio
SITC of Wooden lectern with wired microphone connectivity, 25" table top, with reading lamps, Cable management, Large reading surface as required with cables & connectors as required etc. all complete.
Desktop Hidden Connection Box, Mechanical Locking Device, Smooth Pneumatic Support Structure, DisplayPort, HDMI, VGA+Audio, Network / Telephone, Power Input voltage: 110V-220V / 50-60Hz, Mountable Enclosure for Cables etc. all complete Make: Aaztec / Altenix / Extron
SITC of Multiformat Transmitter, HDMI, VGA, DisplayPort, DVI-D and Audio inputs, Extends VGA, DVI, HDMI 1.4 or DP 1.1, Audio, Ethernet, RS-232, up to 120 Meter over one CAT5/6/7 cable, HDMI 1.4, HDCP 1.4 and DVI 1.0 compliant, HDBaseT compatible, Pixel Accurate Reclocking, Supports HDMI 3D signal formats, Bi-directional RS-232 and IR extension (pass-through and control), Supports HDMI 4K signal formats (4K UHD @30Hz RGB 4:4:4 or @60Hz YUV 4:2:0, up to 9 Gbps) etc all complete Make: Lightware / Extron / AMX
SITC of Wallplate Transmitter, HDMI, VGA, DisplayPort, and Audio inputs, Extends VGA, DVI, HDMI 1.4 or DP 1.1, Audio, Ethernet, RS-232, up to 120 Meter over one CAT5/6/7 cable, HDMI 1.4, HDCP 1.4 and DVI 1.0 compliant, HDBaseT compatible, Pixel Accurate Reclocking, Supports HDMI 3D signal formats, Bi-directional RS-232 and IR extension (pass-through and control), Supports HDMI 4K signal formats (4K UHD @30Hz RGB 4:4:4 or @60Hz YUV 4:2:0, up to 9 Gbps) etc all complete Make: Lightware / Extron / AMX
SITC of HDMI Transmitter, HDMI inputs, Extends DVI/HDMI 1.4, Audio, Ethernet, RS-232, up to 120 Meter over one CAT5/6/7 cable, HDMI 1.4, HDCP 1.4 and DVI 1.0 compliant, HDBaseT compatible, Pixel Accurate Reclocking, Supports HDMI 3D signal formats, Bi-directional RS-232 and IR extension (pass-through and control), Supports HDMI 4K signal formats (4K UHD @30Hz RGB 4:4:4 or @60Hz YUV 4:2:0, up to 9 Gbps) etc all complete Make: Lightware / Extron / AMX
SITC of HDMI Reciever, HDMI inputs, Extends DVI/HDMI 1.4, Audio, Ethernet, RS-232, up to 120 Meter over one CAT5/6/7 cable, HDMI 1.4, HDCP 1.4 and DVI 1.0 compliant, HDBaseT compatible, Pixel Accurate Reclocking, Supports HDMI 3D signal formats, Bi-directional RS-232 and IR extension (pass-through and control), Supports HDMI 4K signal formats (4K UHD @30Hz RGB 4:4:4 or @60Hz YUV 4:2:0, up to 9 Gbps) etc all complete Make: Lightware / Extron / AMX
SITC of Modular Digital Router Frame, 8 Inputs and 8 outputs frame, onboard1 DVI Preview input and test output, Combine non-HDCP and HDCP capable I/O boards in the same frame, Advanced EDID Management, Device control via Ethernet (TCP/IP), RS-232 and USB, Fully non-blocking switching architecture, No video compression, Bi-directional RS-232 extension (pass-through), Supports all embedded audio formats (including PCM, Dolby Digital and DTS high bitrate audio), Pixel Accurate Reclocking, etc all complete Make: Lightware / Extron / AMX
SITC of Combine / Combination of 4 HDBaseT and 4 HDMI inputs, providing HDMI 1.4, audio, Ethernet and RS‑232 extension on a single CAT5/6/7 cable up to 120m in HDBaseT, Resolutions up to 4K / UHD (30Hz RGB 4:4:4 , 60Hz YCbCr 4:2:0) and 48‑bit color depth, bi-directional RS‑232 and Ethernet transmission, built-in PoE injector function, compatible with deep color, Dolby TrueHD and DTS‑HD audio, HDCP enable/disable mode, Pixel Accurate Reclocking, Advanced EDID Management and Frame Detector etc all complete Make: Lightware / Extron / AMX
SITC of Combine / Combination of 4 HDBaseT and 4 HDMI outputs with audio outputs, providing HDMI 1.4, audio, Ethernet and RS‑232 extension on a single CAT5/6/7 cable up to 120m in HDBaseT, Resolutions up to 4K / UHD (30Hz RGB 4:4:4 , 60Hz YCbCr 4:2:0) and 48‑bit color depth, bi-directional RS‑232 and Ethernet transmission, built-in PoE injector function, compatible with deep color, Dolby TrueHD and DTS‑HD audio, HDCP enable/disable mode, Pixel Accurate Reclocking, Advanced EDID Management and Frame Detector etc all complete Make: Lightware / Extron / AMX
SITC of Matrix Switcher of 4 HDBaseT , 4 HDMI Inputs, 2 HDBaseT and 2HDMI outputrs with audio outputs, 4K / UHD (30Hz RGB 4:4:4, 60Hz YCbCr 4:2:0), 3D capabilities and HDCP are fully supported, Built-in PoE injector, Balanced analog audio output for audio de-embedding, Built-in Event Manager control automation feature, HDBaseT compatible, HDMI 1.4, HDCP 1.4 and DVI 1.0 compliant, Pixel Accurate Reclocking, No video compression, Bi-directional RS-232 extension (pass-through), No signal latency, zero frame delay etc all complete Make: Lightware / Extron / AMX
SITC of UHF Wireless Handheld Microphone System, Cardioid dynamic, True Diversity, Modulation mode : FM, Frequency Response : 100 Hz to 15 kHz, RF Sensitivity: 20 dBuV at 60 dBA S/N ratio (50Ω termination), Total Harmonic Distortion: <1.0% (at 1 kHz, ±20 kHz deviation), Dynamic Range > 110dB, switch function : Mute/unmute & On/OFF, Operating range: 100 m (300'), typical (open range environment with no interfering signals), RF Power Output High: 30 mW, Low: 10 mW (switchable), No. of Channel : 10 channels per band, Antenna Input : BNC type, 50Ω - BIAS voltage 12V DC 60mA each for powering an antenna booster, active splitters, an antenna combiner or any other active component., Maximum Output level XLR / Balanced: +9 dBV & 6.3 mm (¼"") / Unbalanced: +4 dBV , Balanced audio output attenuator : Two position switch: 0/-12 dB, Accessories Included: detachable Antennas, Rack mount kit etc. all complete Make: Audio Technica / Shure / Sennheiser
SITC of UHF Wireless Lapel Microphone System, Cardioid Condenser, True Diversity, Modulation mode : FM, Frequency Response : 100 Hz to 15 kHz, RF Sensitivity: 20 dBuV at 60 dBA S/N ratio (50Ω termination), Total Harmonic Distortion: <1.0% (at 1 kHz, ±20 kHz deviation), Dynamic Range > 110dB, Switch function : Mute/unmute & On/OFF, Operating range: 100 m (300'), typical (open range environment with no interfering signals), RF Power Output High: 30 mW, Low: 10 mW (switchable), No. of Channel : 10 channels per band, Antenna Input : BNC type, 50Ω - BIAS voltage 12V DC 60mA each for powering an antenna booster, active splitters, an antenna combiner or any other active component, Maximum Output level XLR / Balanced: +9 dBV & 6.3 mm (¼"") / Unbalanced: +4 dBV, Balanced audio output attenuator : Two position switch: 0/-12 dB, Accessories Included: detachable Antennas, Rack mount kit etc. all complete Make: Audio Technica / Shure / Sennheiser
SITC of UHF Wireless Headworn Microphone System, Cardioid Condenser, True Diversity, Modulation mode : FM, Frequency Response : 100 Hz to 15 kHz , RF Sensitivity: 20 dBuV at 60 dBA S/N ratio (50Ω termination), Total Harmonic Distortion: <1.0% (at 1 kHz, ±20 kHz deviation), Dynamic Range > 110dB Switch function : Mute/unmute & On/OFF, Operating range: 100 m (300'), typical (open range environment with no interfering signals), RF Power Output High: 30 mW, Low: 10 mW (switchable), No. of Channel : 10 channels per band, Antenna Input : BNC type, 50Ω - BIAS voltage 12V DC 60mA each for powering an antenna booster, active splitters, an antenna combiner or any other active component., Maximum Output level XLR / Balanced: +9 dBV & 6.3 mm (¼"") / Unbalanced: +4 dBV, Balanced audio output attenuator : Two position switch: 0/-12 dB, Accessories Included: detachable Antennas, Rack mount kit etc. all complete. Make: Audio Technica / Shure / Sennheiser
SITC of 4 - way Antena Distribution system, UHF (wide-band 440-900 MHz) active unity-gain diversity system, High OIP3 (+ 32 dBm) for maximum protection against intermodulation, 12V DC power to each antenna input to operate powered antennas or in-line RF devices up to 100 mA minimum, Accessories Included: Rack mount kit & BNC cable x 8 etc. all complete Make: Audio Technica / Shure / Sennheiser
SITC of Pair of UHF wide-band directional antennas, Operating Bandwidth : 470-990 MHz, Antenna Type : LPDA (log periodic dipole array) antennas, Impedance : 50 Ohms Typical, Polar Pattern : Elliptical, 90° acceptance, typical, Horizontal adjustment should be possible by rotating the antenna in the mounting fitting etc. all complete Make: Audio Technica / Shure / Sennheiser
SITC of Dynamic Vocal Microphone, Hypercardioid, Frequency Response : 60 - 14,000 Hz, Impedence : 500 ohms, Output Connector: 3 pin XLR Type, Silent on/off operation design switch & Soft-touch finish for a secure, CE etc. all complete Make: Audio Technica / Shure / Sennheiser
SITC of Dynamic microphone for instruments, Hypercardioid, Frequency Response : 60 - 14,000 Hz, Impedence : 600 ohms, Output Connector: 3 pin XLR Type, Silent on/off operation design switch & Soft-touch finish for a secure, comfortable grip, Certifictaion: CE etc. all complete. Make: Audio Technica / Shure / Sennheiser
SITC of Gooseneck Microphone, Cardioid Condenser, 418 mm, Frequency Response : 70 - 16,000 Hz, Impedance : 100 ohms, Maximum Input Sound Level: 134 dB SPL, 1 kHz at 1% T.H.D., Dynamic Range: 106 dB, 1 kHz at Max SPL, Desk Stand with ON/OFF Switch, Output Connector: Integral 3-pin XLRM-type, Certifictaion: CE etc. all complete. Make: Audio Technica / Shure / Sennheiser
SITC of Advanced Digital Audio Processor, AEC Mic Input: min 10 No's, Line Output: min 6 No's or more, USB Audio Interface 24Bit, 48Khz, GPIO Contcats: 6 No's or better, Built in 64 x 64 channel, dual-redundant Dante/AES67 audio transport, 24 channels of freely assignable Acoustic Echo Cancellation, DANTE , Digital Audio Link Port for Future expansion, Frequency Response: 20Hz to 20KHz, Ethernet, Crosstalk (inter-channel @ 1 kHZ): < 75 dB, Certifictaion: CE , FCC etc all complete Make: Music Tribe / Biamp / AtlasIED
SITC of 40 channel 48KHz Mixing Console, 32 mic inputs, 24 bus, 16 Aux outs. Main LCR out and Matrix outputs, Built in Stage Box Interface, 192 kHz, 24 bit ADC and DAC converters with minimum 112 dB dynamic range, Minimum 24 motorised 100 mm faders, Optional wireless remote control for iPhone and iPad, 32 x 32 channel USB 2.0 audio interface, 8 DCA and 6 mute groups, Built in Effect processor, Built in or external 100-Band for all Channel/Bus EQ 's, Auto-ranging universal switch-mode power supply, Digital mixer should be supplied with 32 inputs and 16 output stage Box etc. all complete. Make: Music Tribe / Allen Heath / Yamaha
SITC of 2 Way 12" Full Range Loudspeaker, Switchable Passive/Bi-amp Loudspeaker, 12" LF driver or better and 1"HF compression driver or better, LF/Passive : 500 Watts rms @ 8 Ohms or better, HF :75 Watts rms power@ 6/8 Ohms or better, Frequency Range 45 Hz - 18 kHz , 80°-90° (H) x 30°- 40° (V) rotatable dispersion, Sensitivity: 96dB, Peak SPL: LF - 130dB, HF - 134dB, Birch Plywood Enclosure, Multiple Rigging Point etc. all complete Make: Music Tribe / Renkus-Heinz / Martin Audio
SITC of Flying plate for Left, & Right FOH Speaker System etc. all complete. Make: Music Tribe / Renkus-Heinz / Martin Audio
SITC of Dual 12" or better Band Pass/Front loaded Subwoofer, 800 Watts rms @ 4 ohms or better, Frequency Range 35 Hz - 200 Hz , Sensitivity 100 dB, Impedance 4ohm, 8Ohm, Peak SPL,135 dB , Birch Plywood Enclosure, Multiple Rigging Point etc. all complete Make: Music Tribe / Renkus-Heinz / Martin Audio
SITC of Stage Monitor System, 12" LF ,1" HF Driver Coaxial Design, Rated Power 1100 Watt or better, Class-D Amplifier with inbuilt DSP, Frequency Response : 75 Hz – 18 kHz or better, Maximum SPL 125 dB peak or better, 60-80 degree Horizontal x 40-50 degree Vertical Dispersion, Fully featured user interface with LCD display for ease of navigation, Birch Plywood construction etc. all complete. Make: Music Tribe / Renkus-Heinz / Martin Audio
SITC of Delay Speaker 2 - way full range loudspeaker consisting , 8" LF or bettter ,minimum 1" HF driver, 150 W ot better continuous power handling capacity, Impedance 4/8 Ohms, Peak SPL 119 dB , Frequency Range 60 Hz-18 kHz, Birch Plywood Enclosure , 70°-90° (H) x 50°- 70° (V)dispersion etc. all complete Make: Music Tribe / Renkus-Heinz / Martin Audio
SITC of 2-Channel 2400 W Power Amplifier, Power Output : 1200 W @ 4 Ohms, Integrated DSP with minimum 30 multi-slope parametric equalizers, adjustable high- and low-pass filters, Input & Output Delay, crossover with multiple filter types, Analog & AES3 Inputs, Four channel Input Mixer, THD + N 20 Hz- 20 kHz for 1 W <0.1%, Signal-to-Noise ratio >105 dB, Frequency Response 20 Hz- 20 kHz, Channel separation at 1 kHz >80 dBCommon Mode Rejection 50 dB, Software configurable limiter, Networked control, Certifictaion: CE, FCC, UL etc. all complete. Make: Music Tribe / Powersoft / D&B Audio Teknik
SITC of 2-Channel 1200 W Power Amplifier , Power Output : 600 W @ 4 Ohms, Integrated DSP with minimum 30 multi-slope parametric equalizers, adjustable high- and low-pass filters, Input & Output Delay, crossover with multiple filter types, Analog & AES3 Inputs, Four channel Input Mixer, THD + N 20 Hz- 20 kHz for 1 W <0.1%, Signal-to-Noise ratio >105 dB, Frequency Response 20 Hz- 20 kHz, Channel separation at 1 kHz >80 dB, Common Mode Rejection 50 dB, Software configurable limiter, Networked control, Certifictaion: CE, FCC, UL etc. all complete. Make: Music Tribe / Powersoft / D&B Audio Teknik
SITC of 6.5" Coaxial In-Ceiling Loudspeaker, System Type: In-Ceiling Flush Mount Speaker, Driver Size: Min. 1 x 6.5” Driver or better, Power Continuous / Programme: 50 W / 100 W, Nominal impedance: 8Ohm, SPL Peak: 112dB, Dispersion: 110 Degree Conical or Better, Frequency Range: 75 Hz-18 kHz, Sensitivity: 90dB, Transformer Tap 70V / 100V, Certification: UL1480 / UL2043, Enclosure: Steel Backcan, Included Accessories: Metal Grille, C-ring, Paint Mask, Cutout Templateetc all complete Make: Music Tribe / Martin Audio / AtlasIED
SITC of 8" Coaxial In-Ceiling Loudspeaker, 8” Driver or better, Power Continuous / Programme: 90 W / 180 W, Nominal impedance: 8Ohm, SPL Peak: 116dB, Dispersion: 100 Degree Conical or Better , Frequency Range: 65 Hz-18 kHz, Sensitivity: 91dB, Transformer Tap 70V / 100V, Certification: UL1480 / UL2043, Enclosure: Steel Backcan, Included Accessories: Metal Grille, C-ring, Paint Mask, Cutout Template etc all complete Make: Music Tribe / Martin Audio / AtlasIED
SITC of Dual Channel Class D Amplifier with Energy Star Certification , 2 x 120 W @ 4/8 Ohms and 70V/100V, Distortion <0.05%, Frequency response 20 Hz to 20 kHz, Signal-to-noise >97 dBA etc all complete Make: Music Tribe / Extron / AtlasIED
SITC of Dual channel 240 Watt Class D Amplifier with Energy Star Certification, Delivering 240W @ 4/8 Ohms and 70V/100V, Distortion <0.05%, Frequency response 20 Hz to 20 kHz, Signal-to-noise >97 dBA. Etc all complete Make: Music Tribe / Extron / AtlasIED
SITC of Enterprise-Class Control System, One RS-232/422/485 COM port, Two RS-232 COM ports, Eight IR/serial, eight relay, Programmable event scheduling with astronomical time clock etc complete Make: Crestron / AMX / Extron
SITC of Apple iPad with GUI Application etc all complete
SITC of Programmable 8 Port Relay Module & 4 digital / analogue input module 0-24 Volts DC, low-voltage relay, 6 Watts Power @ 12Volts / 240 V, 44k Input Impedence with cables & connectors as required Make: Make: Crestron / Extron / Vikruti
SITC of VGA+Audio Cable: 3 Feet etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of High Speed HDMI Cable: 3 Feet etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of High Speed HDMI Cable: 10 Feet etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of High Speed HDMI Cable: 50 Feet etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of 4K DisplayPort Cable: 3 Feet etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of 4K DisplayPort Cable: 6 Feet etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of 14AWG 4 Core Speaker Cable (as per actual) etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of 14AWG 2 Core Speaker Cable (as per actual) etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of 16AWG 2 Core Speaker Cable (as per actual) etc. all complete. Make: Kramer / Kordz / Belden / Canare / Sommer
SITC CAT6A cable F/UTP (as per actual) etc all complete Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of 2 Core Sheilded Audio/Control Cable (as per actual) etc all complete Make: Kramer / Kordz / Belden / Canare / Sommer
SITC of Connector and Accessories etc all complete Make: MX / Nuetrick/ Amphenol
SITC of Rack Structure 42 U Air Cooled AV Equipment Rack with Two Nos. of Vertical Power Strips, Cantilever Selves, Cable routing perforations, 4 No. of Spin Wheels etc. all complete. Make: Valrack / Netrack / FSS
SITC of Rack Structure 20 U Air Cooled AV Equipment Rack with 4 Nos. of Vertical Power Strips, Cantilever Selves, Cable routing perforations, 4 No. of Spin Wheels etc. all complete. Make: Valrack / Netrack / FSS
SITC of Rack Structure 12 U Air Cooled AV Equipment Rack with 4 Nos. of Vertical Power Strips, Cantilever Selves, Cable routing perforations, 4 No. of Spin Wheels etc. all complete. Make: Valrack / Netrack / FSS
Description of Work / Item(s)
Amount
HVAC Work
WATER COOLED WATER CHILLING MACHINES :
Supplying, installing, testing & commissioning of microprocessor controlled variable speed Screw Type water chilling machine each having a minimum capacity of 250 TR at chilled water inlet/outlet temperature of 54 deg.F/44 deg.F, Fouling Factor 0.0005 FPS with chilled water circulation rate of 600USGPM and condenser water inlet/outlet temperature of 90 deg.F/ 97.5 deg.F ,Fouling Fcator 0.001 FPS with circulation rate of 1000 us gpm, suitable for operation on refrigerant R-134a for semi hermetic screw type each comprising of the following complete as per specifications and as required. NPLV shall not exceed 0.40 and IKW/TR 0.71 at reducing condenser water temperature as per AHRI 550/590 standard. Chiiler performance shoul be in accordance with AHRI550-590 . Performance testing on AHRI certified test bed at 100% load of one machine at manufacture works on AHRI certified test bed. The COP of the machine should not be less than 5.8. Mono / twin Screw Type Compressor in semi hermetic construction, complete with automatic stepless type capacity control, safety switches, forced feed lubrication system etc, as per specifications. Suitable Nos & suitable capacity squirrel cage induction motor with class 'F' insulation suitable for operation on 415 volts +10%, 50 Hz, A.C. supply. Suitable Nos. & suitable capacity Air Cooled VFD starter suitable for compressor motor complete with ammeter, over load protection, under voltage protection, protection against phase reversal & independent single phase preventors etc complete as required. The VFD shall be installed inside the panel/ in case VFD is installed separately the same shall be IP 54 rated. Necessary drive arrangement. 1 Set – Lubrication device,oil strainer, automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications. 1 No. – Matching shell and tube water cooled
condenser of M.S. shell and integrally both side finned copper tubes. The pressure drop across condenser should be less than 5 meter. 1 No. – Matching shell & tube flooded type chiller for screw type unitsof MS shell and integrally both side finned copper tubes The pressure drop across cooler should be less than 9 meter. 1 Lot – Refrigerant piping fittings, valves and accessories to inter connect compressor, condenser, chiller and expansion valve.The expansion valve shall work on level sensing technology. 1 Set – Microprocessor based control panel (Modbus and bacnet protocol compatible) compete with accessories and inbuilt OEM provided remote monitoring facaility for the remote acess for the chiller by OEM as per the specification. as per specifications. Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications, liquid level control etc. Water flow switches at outlet of condenser & chiller, water drain and air purge valves wherever required. Suction line and chiller insulation(OEM provided factory installed) with minimum 19 mm thick polyvinyl nitrile rubber insulation complete as required. Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with antivibration pads/springs. Initial/first charge of refrigerant gas and compressor oil. RCC/cement concrete foundation for the chilling unit.- 3 NOS (2 WORKING 1 STAND BY)
Hot water Generators
Supply,installation, testing & Commissioning of electrically operated Hot Water Generator of of following actual capacity made of 8mm M.S. sheet and dish end made of 10mm M.S. having 16 gauge stainless steel lining with heaters arranged in banks and Controller and Thermostat so that required qty. of hot water is generated at 50°C with nominal variation, including 100mm thick resin bonded fibre glass insulation of 24 Kg / CUM density finished with 1.25mm thick aluminium sheet cladding including necessary Electrical panel with BMS compatible having suitable Incoming and outgoing Switchgears for Boiler, automatic Controls including inlet and outlet connections for water complete with pressure release valve, low level cut-out, Autovent sight-glass as per specification complete as required. (Degree of protection IP52 with IS 2147) - 150 KW
Heating capacity : 150 KW (1W+1SB)
Water in temp. : 45 deg C
Water out temp : 50 deg C ,Flow Rate : 140USGPM
Condenser water Pumps Set
Supply, erection, testing and commissioning of Centrifugal Vertical Split Casing condenser water pump set capable of delivering 1000 USGPM of water against 28 mtr head each comprising of the following and complete as per specifications and as required. 1 No. - Split Casing/end suction back pull out type pump with bronze impellar, S.S Shaft, CED Coated CI body and mechanical seal.1 No. - Split Casing/end suction back pull out type pump with bronze impellar, S.S Shaft, CED Coated CI body and mechanical seal.1 No. Suitable HP, TEFC squirrel cage induction motor with class 'F' insulation,Eff-1, 1450 RPM synchronous speed, operating on 415 Volts ± 10 %, 3 phase, 50 Hz A.C. supply. Unless otherwise specified, renewable wear ring of bronze shall be furnished atleast on the casing
Pump as above (2 working+1 Stand by)
Chilled water Primary Pumps
Supplying, erection, testing and commissioning of Centrifugal Vertical Split Casing/ primary chilled set capable of delivering 600USGPM of water against a head 20 Mtr. each pump shall comprise the following as required as per specifications.1 No. -Vertical Split Casing type pump with bronze impeller, S.S Shaft, CED Coated C.I body and mechanical seal. Duly insulated with 80 kg/cum density resin bonded fiber glass cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications.1 No.- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulation,IP -55 Protection,Eff-1, 1450 RPM synchronous speed, operating on 415 volts ± 10%, 3 phase, 50 Hz A.C. supply. Pump as above (2 working+1 SB)
secondary pumpwith vfd
Supplying, erection, testing and commissioning of package type Centrifugal Vertical split casing Secondary chilled with VFD and all pump system controller, comprising of:Pumping set with CED Coated cast Iron casing, Bronze impellers with stainless steel shaft, connected to suitable capacity TEFC ventilated induction motor with class 'F' insulation, Eff-1, 3 Phase, 1450 RPM, suitable for 415 volts ± 10%, 3 phase, 50 Hz A.C. supply. Duly insulated with 80 kg/cum density resin bonded fiber glass cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications Unless otherwise specified, renewable wear ring of bronze shall be furnished atleast on the casing . Variable secondary Panel should have a dedicated programmable logic controller with individual drive for each pump and with required no. of sensors and the entire unit has to be procured from the Pump manufacturer to ensure the smooth operation of the system. The Programmable logic controller shall be able to control minimum 1 Pump and maximum of 4/6 Pumps, Automatic cascade control of pumps, automatic sequence change, Friction loss compensation, pump status shall be there. Display shall be graphical type with minimum 320 pixels X 240 Pixels VGA display with backlight.Drive should have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz. An IP41/IP55 Nema Standard powder coated steel enclosure for Basement/Roof top, with sufficient capacity of cooling fan shall house all the electrical control components.Microprocessor based control panel shall have suitable hardware & software so that it can be integrated directly to IBMS with standard communication open protocol using backnet / Modbus as well as open IP.(All the Pump set will have their control panel with respect to the motor rating).
All pumps to be provided with separate variable frequency drives. Control panel should also consist of cooling fan.One panel for each job will be provided (for a set of two pumps) and the panels should be installed adjacent to each other.The pumps should be suitable for heating as well as chilled water circulation.Lot-Mounting frame work with anti vibration pads.Necessory 2 nos. of Ectronic Differential Pressure Transmitters and control wiring (control wiring is quantified in electrical Sub head) as required.suitable flanged suction and delivery headers in C-Class MS.Complete set system to be mounted on a common MS base frame and shall follow following duty with following no. of pumps:Flow Rate : 600 USGPM , Head : 28 Metre WC
Hot Water Pump Sets
Supply,erection, testing and commissioning of end suction back pull out type Hot water centrifugal pump for hot water recirculation, pump set capable of delivering 140 USGPM of water against 30 mtr head each comprising of the following and complete as required 1 No. - centrifugal type pump with bronze impellar and mechanical seal.Duly insulated with 80 kg/cum density resin bonded fiber glass cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications.1 No. Suitable HP, TEFC squirrel cage induction motor(Eff-1) with class ' B' insulation, 1500 RPM synchronous speed, operating on 415 Volts + 10 % , 3 phase , 50 Hz A.C. supply. (1 working+1 stand by )
Cooling Towers 9.45 lacs kcal/hr heat rehection capacity
Supply, installation, testing and commissioning of FRP Induced draft Cross / Counter flow, 1 to 4 fan as required direct / gear driven site erected cooling tower of capacity as mentioned below based on the parameters given below and complete with PVC Fill Louvers Drift Eliminator Weather proof IP 55 TEFC Motor ( IE-2), Propeller Fan FRP basin with additional sump in the bottom of the basin on every outlet point to avoid vortex formation in the condenser water pipe line Hot dip galvonized Steel Ladder, Stainless Steel hardware including nut, bolt, washer etc. The cooling Tower shall confirm to technical specification given in the tender The maximum allowable sound power at distance of i M from the cooling Tower shall be less than 75 dB. Tower fan motor shall besuitable for VFD operation and operation of VFD system shall be approach of cooling towerm with separate isolator / MCCB etc. as required.Cooling Towers 9.45 lacs kcal/hr heat rehection capacity
Water Leaving Temperature : 32.3 Deg C
Water Entering Temperature : 36.4 Deg C
Water Flow Rate : 1000 USGPM
Ambient Wet Bulb Temperature : 28.3 Deg C
Cooling Tower as Above ( 2 working+1 stand by)
FLOOR MOUNTED/ CEILING SUSPENDED AIR HANDLING UNITS :
Supply,installation,testing and commissioning of sheet metal sectionalised construction draw thru type in Double Skin construction as per the specifications. Each Air Hndling Units shall be with filter sections with filters as mentioned in specification and datasheet and chilled water cooling coils/hot water cooling coils of Copper tube and Aluminium fins construction,squirrel cage induction EFF1 type motor,mixing box, suitable for humidifier,vibration isolators,coil size shall be at face velocity of 500 feet per minute .Motor shall be suitable for 415V/3Ph/50 Hz AC electric supply. Air moving capacities shall be as detailed below as per drawings and specifications.
ALL OTHER AHU DETAILS SHALL BE AS PER DBR DATASHEETS AND SPECIFICATION
AIR HANDING UNITS
3500 CFM-60 MM ESP
2100 CFM-60 MM ESP
4000 CFM-60 MM ESP
2500 CFM-60 MM ESP
2000 CFM-60 MM ESP
2600 CFM-60 MM ESP
9000 CFM-60 MM ESP
2500 CFM-40 MM ESP
2500 CFM-40 MM ESP
1500 CFM-60 MM ESP
5500 CFM-40 MM ESP
5000 CFM-60 MM ESP
3500 CFM-40 MM ESP
3750 CFM-40 MM ESP
3750 CFM-40 MM ESP
2000 CFM-40 MM ESP
2500 CFM-40 MM ESP
2500 CFM-60 MM ESP
4500 CFM-40 MM ESP
2000 CFM-40 MM ESP
14000 CFM-50 MM ESP
9500 CFM-50 MM ESP
2000 CFM-40 MM ESP
3000 CFM-60MM ESP
3000 CFM-125 MM ESP
1000CFM-60MM ESP
Supply, installation, testing and commissioning of ceiling suspended High static type FCU's each complete with 3 row deep cooling coil of copper tubes aluminium fins construction, centrifugal fan, 3 speed motor, filters insulated drain pan, coil piping connections, condensate drain connection, complete as required complete with 1 no bronze ball valve with strainer , 1 no ball valve without strainer, 1 no pressure independent balancing and control valve . , cooling thermostats and electrical wiring, manual air vent valve, SP isolator with MS enclosure box should be Provided etc. as required as per specification & drawings with the following capacities:-
1.0 TR-400 CFM
1.5 TR-600 CFM
2.0 TR-800 CFM
3.0 TR-1200 CFM
VARIABLE FREQUENCY DRIVES-Supply, Installation, testing & commissioning of HVAC dedicated VFDs suitable for the following AHU fan motor capacity (The integration of the VFD with AHU is included in this item) with IP 54 enclosures with Mains disconnect, complying with the tender specifications and having:Built-in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the VFD. Built-in EMC Filters (electromagnetic compatibility filters) for VFDs for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution): 2004 Category C 1, for required length of cable between motor & VFD.Two/Three -feedback PID (Propotional integrated derivative) controller having capability to simultaneously accept 2/3 feedback signals from temperature sensors for process optimization and accordingly regulate the speed of the AHUs.Automatic Energy Optimization for maximum energy savings.
Supply, Installation, testing and Commissioning of ceiling / floor mounted Rectangular/ROUND box type accoustically insulated centrifugal Inline fan, constructed of GSS duly powder coated as per detailed specifications, complete with forward curved SISW fan, motor and drive suitable for 220 ± 10% volts, 1 phase, 50 Hz A.C supply, with necessary canvas connection etc complete in all respects. for toilet exhaust
700 cfm at 15 mm static
Supplying, installation, testing & commissioning of Propeller type exhaust air fans suitable for following capacities complete with electric motor suitable for operation on 220 V+ 10%,50 Hz, 1 phase AC supply fitted with speed regulator, mountings, frames, louvers and bird screen etc. of the following capacities.e unit shall be complete as per drawings and specifications.
200 mm dia
Axial flow Fan for EXHAUST air Supply :
Supply, Installation, Testing & Commissioning of GSS long casing (Motor should completely coverd in fan casing) tube Axial flow type fans for parking ventilation exhaust fans and smoke exhaust fans for areas mentioned in datasheet complete with aluminium alloy blades with aerofoil design, bird screen,fire rated flexible connection & gravity louvers , vibration isolators at outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt distance from fan outlet shall not be more than 80db(A) (Room Condition). Capacity shall be as follows & as per detailed technical specification: Fans should be AMCA certified. RPM Should Not exceed 1450.However lower CFM fans upto 5000 CFM can be provided at 2850 Rotations per minute. Outlet velocity shuld not exceed 10 m/s of below capacities. fans shall be fire rated (250 deg c for 2 hours)
12000 cfm at 20 mm static - musuem smoke exhaust
10000 cfm at 25mm static - parking exhaust
10000 cfm at 30mm static - seminar , e library
6000 cfm at 20 mm static - plant room exhaust
5000 cfm at30 mm static - conference hall
4500 cfm at 20 mm static - cafeteria smoke exhaust
3500 cfm at 25 mm static - kitchen exhaust
Axial flow Fan for Fresh air Supply (in case of fire) :
Supply, Installation, Testing & Commissioning of GSS long casing (Motor should completely coverd in fan casing) tube Axial flow type fans for parking smoke fresh airand staircase pressurization fans for areas mentioned in datasheet complete with aluminium alloy blades with aerofoil design, bird screen, flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt distance from fan outlet shall not be more than 80db(A) (Room Condition). Capacity shall be as follows & as per detailed technical specification: Fans should be AMCA certified. RPM Should Not exceed 1450.However lower CFM fans upto 5000 CFM can be provided at 2850 Rotations per minute. Outlet velocity shuld not exceed 10 m/s of below capacities.
16000 cfm at 25 mm static
10500cfm at 25 mm ststic
Supply installation testing and commissioning of clean room labs monitoring system . the system shall include following- DDC controller with front display to monitor and control the parameters such as temperature , humidity and pressure diffrential across ahu fan , filters , room and adjacent area . System should include DDC controller with field instruments like T+RH sensor, Diffrential pressure sensor across filters and fans , diffrential pressure switch across room and adjacent area . pessure differential range 10mm-125mm. , Differential Pressure switch across the Air Handling Units indicating the filter status (pressure differential 2mm-25mm) . Controller shall take inputs from Temperature and RH sensor , pressure differential between lab and adjacent area , pressure differential across coil , filters and based on these inputs it shall control instruments /equipments like actuator of cooling coil , heating coil , vfd for fan speed . SITC of All necessary control , power, communication wiring included in contractors scope
Main HVAC Panels
Supply, installation, testing and commissioning of the following integrated cubical type dead front extensible sheel control panel, anchoring of panel to foundation. The panel shall be suitable for 415Volts/3Ph/50Hz. Quoted price shall also include Ruber Mats etc. The Panel shall have separate compartment for bus bar and cable alleys. The following components and accessories ashall be mounted within each control pane.
INCOMER
Two set of 1600 Amps Electrically operated draw out type 4 pole ACB with 6 NO & 6 NC contacts and complete with the following
Overvoltage tripping mechanism for persistent voltage exceeding 110% of the rated voltage for more than 5 minutes
CT operated over current and earth fault relay(IDMT) with CTs 4000/5A SP 10 protection class VA burden
Phase indicating Lamps with toggle switches and control fuses.
BUS COUPLER - 1 No 1600 Amps ACB with ON/OFF and trip indication .
Bus Bars :
Aluminium Bus bar with heat shrinkable sleeves rated at 2000 Amps for 3 ph and neutral phase. Bus bar shall have maximum current density of 0.8amps/mm2 and the neutral phase bar of not less than 50% capacity 2000A EP ACB for Bus Coupler
Outgoings:
Total Panel Price
Control Panel in Air Handling Units (AHUs) :
Supply,installation,testing and commissioning of the following Cubical type openable front , sheet steel wall mounted control panels sleeve type. Al. bus bars including anchoring inton the wall. These panels shall be completer in all respect as per the drawing and specification.
The panel shall include the following accessories :
MCCB as per rating given below.
Terminal block for power distribution.
Single Phase Preventor.
Phase indicating lights and indicating lights for ON/TRIP status
Time delay relay for automatic restart of AHUs motors.
All starters shall have suitable potential free contacts
Wiring for microswitch for stopping the fan when fire dampers closes.
The number of AHU panel shall be as detailed below :
25 amps TP MCB with 1 No. 5.0 HP + 3KW DOL Starter for PT Humidifier
25 amps TP MCB with 1 No.5. HP + 1KW DOL Starter for PT Humidifier
25 amps TP MCB with 1 No.5 HP
32 amps TP MCB with 1 No.7.5HP
63 amps TP MCB with 1 No.20HP
Condenser Water Piping :
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc.adequately supported on rigid supports duly painted / buried in ground excavation and refilling etc.as per specification and as required complete in all respect.
Note:- The Pipes size 150mm & below shall be M.S.'C' class as per IS:1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS:3589, from minimum 6.35mm thick M.S. Sheel for pipes upto 350 mm dia.And from mininum 8mm thick MS sheel for pipes of 400 mm dia and above.
250 mm dia.
200 mm dia.
100 mm dia.
50 mm dia
Condenser Circuit Valves without insulation
Supply,fixing,testing and commissioning of following size valves, guages and strainers for condenser water circulation as per drawings and specifications
Butterfly Valves (manual) with CI body SS disc nitrile sheet and O ring PN 16
250 mm dia
200 mm dia.
100mm dia
50 mm dia
BALANCING VALVE with built in measuring facility with CI body flanged conrtuction with EPDM coated disc with long pitch & PN 10 pressure rating as specified.
200 mm dia
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095 with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required - 200 mm dia
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified
200 mm dia.
Supply ,Installation ,Testing and commissioning of Flexible connector for following Dia. pipe suitable for PN 16 pressure rating to be installed at pump and chiller suction and discharge .
200 mm dia
SITC of flow switch
Supply ,Installation ,Testing and commissioning of Y -STRAINER of ductile body flanged ends with stainless steel strainer for condenser water piping without insulation as specified . - 200 mm dia
S/F of POT STRAINER - 250 MM DIA as show in drawing
Supply,installation,testing and commissioning of following Thermometers and pressure guage as per drawings and specifications for the condenser water circuit complete with fittings
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometers.
Insulated chilled/hot Water Piping :(Nitrile rubber insulation) Minimum 45 Kg/cu m density thermal conuctivity 0.037 W/MK or better at 20 deg.
Supply,laying,fixing,testing and commissioning of following nominal sizes of chilled water/ hot water piping inside the building (with necessary clamps,vibration isolater and fittings but excluding valves,strainer,gauges etc.) dully insulated with following closed cell elastometric nitrile rubber of class'O' insulation applied by adhesive confirming to standard specifications and finally applying 0.63mm aluminium sheet cladding complete with type3,grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints and repairing of damage to building etc.as per specification and as required complete in all respect.
Note:- The pipe of sizes 150mm & below shall be M.S.'C' class as IS:1239 and pipe size above 150mm shall be welded black steel pipe heavy class as IS:3589,from minimum 6.35mm thick M.S. sheet for pipe upto 350mm dia. and from minimum 8mm thick M.S. sheet for pipes 400mm dia and above.
200 mm dia. (32 mm insulation)
150 mm dia. (32 mm insulation)
125 mm dia. (32 mm insulation)
100 mm dia. (32 mm insulation)
80 mm dia (32 mm insulation)
65 mm dia (32 mm insulation)
50 mm dia. (32 mm insulation)
40 mm dia. (32 mm insulation)
32 mm dia. (19 mm insulation)
25 mm dia. (19 mm insulation)
Chilled Water and Hot water Circuit Valves :
Supplying,fixing,testing and commissioning of following valves, strainers,gauges in the chilled / hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications
Butterfly Valves /Ball valves(Manual) with CI body SS Disc, Nitrile Rubber seal and O- ring PN16 pressure rating for chilled water / hot water circulation as specified.
200 mm dia
150 mm dia
100 mm dia
80 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
32 mm dia. BALL VALVE
25 mm dia. BALL VALVE
Ball Valve set with and with Y stainer duly insulated of the following sizes as per specifications and drawings. -25 mm dia
Ball Valve set with and with Y stainer duly insulated of the following sizes as per specifications and drawings. -32 mm dia
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified
150mm dia
100mm dia
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with insulation ,CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095 with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required - 150mm dia
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve complete with insulaion mentioned in piping section , with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum
80 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
150mm dia
100mm dia
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
150 mm dia
100 mm dia
80 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
Supply ,Installation ,Testing and commissioning of Flexible connector for following Dia. pipe suitable for PN 16 pressure rating to be installed at pump and chiller suction and discharge .
150 mm dia
100 mm dia
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometers.
Supply, Installation, testing and commissioning of thermostat for various air handling Units.
Three Way Motorized Valves with modulating motor actuator & transformar for converting AC to DC, in heating coil of air handling units as per specification gof following sizes. -25 mm dia
Three Way Motorized Valves with modulating motor actuator & transformar for converting AC to DC, in heating coil of air handling units as per specification gof following sizes. -32mm dia
Close Type Expansion Tank & Air separator :
Supply,installation,testing and commissioning of close type expansion tank of 1000 litres capacity with EPDM butyle membrane tested at minimum 16 bar pressure complete with its pressurisation unit with double pump and its suitable panel and required accessories for proper installation and working as per drawings specifications. (for chilled water circuit)
Combined Air and Dirt Separators Supply, Installation, testing and commissioning of a combined Air and Dirt Separators as per Specifications on the return water line located at the pump suction or a suitable location in AC Plant Room as suggested and suitable for 1200 gpm water flow. Separator should be capable of removing all micro bubbles and should have a steel tube & copper wire media to carry out its operation. It should be able to remove upto 10 microns of dirt particles. The separator should be complete with high capacity air vent, service valve, non return valve, butterfly valve connection for makeup water inlet, flanges, drain valve etc
Drain Piping :
Supply,installation,testing and commissioning of condensate drain water piping of GI ' Medium' Class complete with fittings like elbow, tees, reducers bends M.S. flanges, Supports welding, Painting etc. as required confirming to tender specifications and of following size.
specifications of below sizes.
65 mm dia
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia
Supply,installation,testing and commissioning of Air Vents 15 mm dia.
of 1" dia Ball valves for drain with fittings etc.
Rectangular Ductwork :
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required
24 Gauge (thickness 0.63 mm sheet)
22 Guage (thickness 0.80 mm sheet)
20 Guage (thickness 1.00 mm sheet)
18 Guage (thickness 1.25 mm sheet)
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet as per cpwd specifications complete as required
24 Gauge (thickness 0.63 mm sheet)
22 Guage (thickness 0.80 mm sheet)
20 Guage (thickness 1.00 mm sheet)
18 Guage (thickness 1.25 mm sheet)
Supply,installation,testing and commissioning of Aluminum sheet metal rectangular ductwork complete with supports,elbows dampers/splitters/vanes/hangers/supports/rubber gaskets and all ancilliary items as per approved drawings and specifications of the following sheet thickness.:
24 Guage
22 Guage
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required
19mm thick Insulation
25mm thick Insulation
Duct Accoustic Lining :
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications
Grilles/Diffusers/Louvers/VCDs/FDs :
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room
Damper
Actuator
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core .
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. 200 mm dia
Supply,installation,testing and commissioning of MS powder coated Exhaust Grilles/louvers without dampers but with wire mesh jali for exhaust.
Fire Dampers
Supplying,fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required sizes i/c control wiring,the damper shall be motorised and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored.The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Fire dampers
Actuator
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
Power Cabling :
Supply,installation,testing and commissioning of PVC insulated sheathed 1.1 KV grade armoured Al. Power cables from various panels upto their respective equipment on MS painted perforated trays with appropriate clamps/fixing arrangements as per specifications and drawings.
3.5 C X 400 mm2 Aluminium Cable
3.5 C X 95 mm2 Aluminium Cable
3.5 C X 25 mm2 Aluminium Cable
3.5 C X 50 mm2 Aluminium Cable
4 C X 16 mm2 Aluminium Cable
4 C X 10 mm2 Aluminium Cable
3 C X 6 mm2 Copper Cable
3 C X 4 mm2 Copper Cable
Supply,installation,testing and commissioning of perforated 2mm CRCA sheet steel powder coated cable trays of following sizes complete with joints+C217 coupling plates and nut bolts etc including providing and fixing of MS hangers etc as required as per the drawings and specifications
150mm wide and 50 mm deep
300 mm wide and 62.5 mm deep
450 mm wide and 62.5 mm deep
Earthing :
Supply,installation,testing and commissioning of double earthing continuity conductor of GSS from Panels to respective equipment as per drawings and specifications.
25 mm X 5 mm strip
6 SWG wire
PAN TYPE HUMIDIFIER
Supply & installation of Humidification Package comprising of Pan Type Humidifier, Humidification Tank, Heaters, Internal Controls/Wiring etc. complete in all respect. - Capacity
Underdeck Insulation of Exposed Roofs:
Supply and fixing thermal insulation on exposed roof ( underdeck) with 13mm thick Cross Linked Closed Cell Polyethylene FR-XPE insulation of density 33 kg/cub.mtr with adhesive (pidilite DR-505) etc. as required and finally fixed with the help of rawl plug & dash fastners.
Shreejikrupa Project Limited
K S M BASHIR MOHAMMAD AND SONS
Shreejikrupa Project Limited
K S M BASHIR MOHAMMAD AND SONS
Krishna Buildspace Pvt.Ltd.
Shreejikrupa Project Limited
Krishna Buildspace Pvt.Ltd.
Shreejikrupa Project Limited
Krishna Buildspace Pvt.Ltd.
K S M BASHIR MOHAMMAD AND SONS
K S M BASHIR MOHAMMAD AND SONS
Shreejikrupa Project Limited
Krishna Buildspace Pvt.Ltd.
Shreejikrupa Project Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid