RequiredOEM Authorization Certificate Bid to RA enabled No Potable Water Purification System Reverse Osmosis Or UV Based ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Certification for the product CE CE
RequiredWQA
RequiredNSF
RequiredNA Certification number and date - * Manufacturers Quality System ISO 9001:2015 ISO 9001:2015 1/7 Certifications Manufacturers Environment Management System Certifications ISO 14001:2004 ISO 14001:2004 Manufacturers Health and Safety Management System Certifications ISO 18001:2007 ISO 18001:2007 Performance Parameters Maximum Input Water TDS allowed to the system 1000 1000 Type of water purification technology RO RO+UF
RequiredRO+UV+UF
RequiredRO+UV+UF+Alkaline
RequiredR0+UV+Alkaline
RequiredRO
RequiredUV
RequiredRO+Alkaline
RequiredRO +UV
RequiredUV+UF Aavailability of sediment and activated carbon filter Yes * Operation Fully automatic with auto cut off Fully automatic with auto cut off
RequiredSemi Automatic with External Auto Cut Off Ultraviolet (UV) LAMP Yes Yes
RequiredNo Conformity to Standard for Ultraviolet system IS 14724 (latest) for water purification system with Ultraviolet disinfection IS 14724 (latest) for water purification system with Ultraviolet disinfection
RequiredNA if UV not provided "Ultra Voilet (UV) Lamp power in watts (Hint put zero in case UV is not available)" 1 * Recovery at 27 degree Centigrade 25-35 25-35
Required30-40
Required50-60
Required70-80
Required90-100 Output Water Conforming standard IS 10500 (latest) * Filtration Capacity in liter/hour 15 * Provision of Arsenic removal Yes Yes
RequiredNo Provision of Floride removal Yes Yes
RequiredNo Provision of Chloride removal Yes Yes Alkaline filter No Yes
RequiredNo 2/7 Storage tank Inbuilt Inbuilt Type of out put water Storage Tank ABS Food Grade Stainless Steel
RequiredClay Pot (Terracotta)
RequiredCopper
RequiredABS Food Grade
RequiredNA Storage Tank Capacity (storage tank external for higher capacity if required to be arranged by buyer) 8ltr 8ltr
Required10ltr
Required12ltr
Required16ltr
Required25ltr
Required50ltr
RequiredStorage tank to be arranged by buyer
RequiredNA Minimum inlet pressure 0.3 KG/CM2 0.3 KG/CM2
Required0.6 KG/CM2
Required1 KG/CM2 Maximum inlet pressure 3.5 KG/CM2 * Maximum inlet temperature 35 DEGREE 35 DEGREE
Required40 DEGREE Digital display No No Real time TDS display No No Real time pH Display No No High pressure pump No No Raw water/Chemical Raw water/Chemical Cleaning PUMP No No Micron Filter Yes Yes Total Dissolved Solids Removal Percentage from RO Membrane NA for UV only NA for UV only Particulate Filter Porosity 5 micron 5 micron Pressure vessel Sand Filter Yes Yes Pressure vessel carbon Filter No No Pressure Vessel Dual Media Filter No No Membrane Housing No No Body of filter ABS Food grade ABS Food grade Auto cut Yes Yes Number of candles 2 2 Power supply 230 Volt single phase 230 Volt single phase Installation Type Wall mounted Wall mounted Miscellaneous Warranty in years 1 1 3/7 Parameters including replacement of filters Sediment & carbon twice a year) Warranty in years free replacement of machine 1 1 Antiscalant- where silica is up to 10 ppm/where Mica is up to 100 ppm Yes Yes Availabilty of type test Test REPORT for Filtering Size of micron Particles No No TYPE Test certificate No and date for Filtering Size of micron Particles - * Name and Address of laboratory which conducted Test for Filtering Size of micron Particles: - * Availability of type Test Report on Microbial Efficacy from Govt/NABL/ilac Lab - * Type Test certificate No and date for Microbial Efficacy - * Name of the lab - * Availability of test report from Govt/NABL/ilac Lab (Design Evalution Report as per IS:14724 No No Test certificate No and date - * Name and Address of laboratory which conducted Test - * Availability of test report from Govt/NABL/ilac Lab regarding water quality as per IS:10500 Yes * Type Test certificate No and date - * Name and Address of - * 4/7 laboratory which conducted type Test regarding water quality Copies of certifications and reports to be given to buyer at time of supplies Yes * User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Availability of toll free centers for customer support No No Installation and Commissioning inclusive in the scope of Supply* No No Availability of NABL Accredited Laboratory Facility with OEM No No Name and Address of NABL Accredited lab with OEM
RequiredIf Not available put NA - * Inlet Pipe & Fitting from raw water scorces to water purification system Not applicable Not applicable Pipe & Fitting from Out let to purified water tank Not applicable Not applicable Electrical fitting and plug points To be arranged by buyer/consignee * Scope Civil Work if any required during installation All Civil work shall be responsibility of buyer * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters