Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted | |
| 2 | L2₹25.6 L+₹2.7 L (11.8%)Rejected-Finance VILL POST MANJHULI PS BAKHITIYARPUR KHUSRUPUR DIST PATNA BIHAR 803202 | NALANDA | BIHAR | 803202 | L2 | Rejected-Finance Other than lowest quoted | |
| 3 | L3₹26.0 L+₹3.1 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted | |
| 4 | L4₹26.5 L+₹3.6 L (15.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted | |
| 5 | L5₹26.6 L+₹3.7 L (16.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest quoted |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
26 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
SPL REPAIRS TO BLDG NO P9 (HANGER) AT 1 (I) RO FLT UNDER GE RANCHI
2024_MES_658252_1
8200/1565/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Ranchi, 7th Club Road Ranchi, PI
Class E Cat a (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹46,600
Yes
25 Oct 2024
7 Jun 2024
28 Jun 2024
8 Jun 2024
26 Jun 2024
21 Jun 2024
Amount
S&F in repair anti bird net , machine made of 22x22mm square size black/blue colour made of high density polythene UV stabilized wire of size 720/2x3(1.00mm) dia with twine, breaking strength 22.00kg, knot breaking strength 28.00kg and mesh breaking strength 18 kg, 380 Den/15ply including 4.00mm dia border rope of high density UV stablized rope monofilament and fixed to wall including 'T' type nuts & bolts with 5.00 to 10.00mm dia washers, at approximate height of 10.00mtr & above of hanger, includig all necessary scaffolding, ladder etc, complete all as specified and directed Make:- GARFIL/TUF ROPES/SS ROPES/BIRDNET. Note:- All safety measures for the safety of workmen shall be ensured by the contractor, Insurrance of workers shall also be got done by the contractor before execution of this item. This aspect shall deemed to be included in quoted rates.
Repairs of MS rolling door shutter in area, not exc 100 sqm (in each) for any type and position, taking down and up as railed or derailed position and refitted or refixing in same position after applying one coat of synthetic enamel paint on existing MS steel surface, like angle, tee, flat iron etc, greasing at hinges, rollers and mild steel runner surface for smooth (opening/ closing) function, with necessary minor repair work if required like as MS angle, MS roller, Galvalume corrugated or plain sheet (0.50mm, 550 Mpa) or similar work etc if required complete all as specified and directed. (Note: Additional MS work or Galvalume sheet will be paid separately).
S&F framed work such as grills, gratings etc. With ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming Fe 290, Gde -E -165
Dimantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings.
S&F prepainted galvalume aluminium zink coating GI based corrugated/ semi - corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with coach screw as per manufacturers instrution complete all as specified and directed
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall and ridge,fixed with self tapping srews complete all as specified and directed
S&F 0.63 Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 as in roof covering fixed with coach screw as per manufacturers instrution complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
Dismantling of wall and ceiling board any thickness/description including cover fillet .
S&F Anodised Aluminium snap grid size 605x605mm frame work for false ceiling complete all as specified and directed
M&L 4mm thick non asbestos fibre cement designer building board of size 600X600 fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping.
Dismantling floor, hearth or wall tiling includiing cement mortar bedding, removing serviceable tiles to store and rubbish off the premises
M&L screed bed or bedding layer of cement mortar 15 mm thick for laying floor finishes in CM 1:6 for fixing tiles.
M&L Non skid ceramic joint free coloured tiles 7-8 mm thick (square or rectangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement. to match as in floors complete all as specified and as directed.
All as per item No 15 above but on vertical surfaces such as skirting, dado, risers to steps etc.
M&L light shade vitrified tiles 10 mm thick ( square / rectangular) area of each tiles not exceeding 0.36 sqm in as in floor etc. set & jointed in neat cement slurry & pointed in white cement to match complete all as specified and as directed .
All as per above item No 17 above, but on vertical surface as dado/ skirting
M&L screed bed or bedding layer of mortar 10 mm thick in CM 1:4 as backing coat for laying tiles in dado , on brick or concrete surfaces
M&L for glazed ceramic coloured tiles in vertical surfaces 350 X 250X 7/ 450x350x7mm thk set and jonnted in cement slurry and pointed in white or colour cement to match complete all as specified and directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for
M&L 75mm thick PCC type C-2 1:3:6 (using 40mm graded stone agg) as in plinth protection/Path/floor finishing surface of concrete topping even and fair without using extra cement complete all as specified and directed
M&L cement concrete type D-2, 1:4:8 (40 mm graded aggregate) 75 mm thick as in Sub-base of floor.
M & L machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade laid over sand cushioning complete all as specified and as directed.
M &L sand filling under floors or in foundations including watering and consolidation.
M&L, 20mm thick screed bed or bedding layer of mortar in CM (1:6) for lying floor finishes and surface fair and even.
M&L Chequered cement concrete tiles (300x300x25)mm thick, set, jointed and pointed in neat grey cement slurry with grey pigment cement and pigment in floors
Taking down cement plaster of any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbinng down with water, etc.
M&L rendering 10mm thick in CM 1:6 on fair faces of brick work , finished even and smooth without using extra cement.
M&L rendering 15mm thick in CM 1:4 on fair faces of brick work , finished even and smooth without using extra cement.
M & L preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed
M & L preparation of complete removal of existing treatement from old plastered surface of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed
Taking down existing chowkats or frames, without taking out shutters from the frame, n exc 1.5 Sqm, complete all as specified and as directed
Taking down existing chowkats or frames , without taking out shutters, from the frame, exc 1.5 Sqm but not exc 4 Sqm each,
S&F powder coated anodised/aluminium frame of size 65mm x 38mm x 1.00 thick or appropriate section as directed including with frame standard section for sliding type windows /ventilatorss with one or more rebates including joining cleats, beading, handle with locking arrangement, rubber gasket for fixing etc complete with and including 5.5 mm thick tinted glass n.exc 1 Sqm each panes (window of frame 3 tract wt not less than 0.50kg/RM and shutter having wt not less 0.45kg/RM) all as specified and directed
S&F door closer hydraulically regulated, designated No- 2 universal type, suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 kg aluminium (die cast) body.
S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
S&F in repair Harrison rails (Curtain rails), mild steel, chromium plated including with supply & fixing brackets, stops, rollers with endcaps etc.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for taking credit and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down and refixing of ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades complete all as specified and as directed.
M & L Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- (Note: Modular cover plate with frame of any module is included in the rate quoted)
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
Description all as per item No 44 here in before but using 2.5 sq mm single core copper conductor cable FRLSH of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm FRLSH copper conductor cable PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
Description all as per item No. 44 here in before but using 4.0 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for power point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point)
S & F Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
M & L Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F MCB Single pole and neutral rated capacity 40 to 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps complete all as specified and as directed complete all as specified and as directed
S & F LED mirror light 9/10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make- Bajaj Havells, Philips.
S & F wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make :- Make Bajaj Philips, Havells.
M/S JAI MATA DEE CONTRUCTION CO. (BID ID -3036204)
M/S Manoj Kumar Sinha (BID ID -3037539)
jai maavindwashni sales & supply (BID ID -3037476)
M/S ABDHESH CONSTRUCTION (BID ID -3037638)
M/S DILIP KUMAR (BID ID -3036215)
Bihar traders (BID ID -3040334)
ISHAAN ENGINEERING (BID ID -3036716)
BHARATI ENTERPRISES (BID ID -3038041)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .