Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹25,980
Closing Date
8 Oct 2020, 6:00 pmClosed
Asst. Gen. Manager (Engg-E)
Asst. Gen. Manager (Engg-E), Airports Authority of India, Goa Airport
Annual Maintenance contract of 02 nos. 33KV HT Automatic Voltage Regulator (HT AVR) installed at Goa Airport
2020_AAI_56187_2
AAI/Go/E/AGM-E/AVR/NIT08/20-21
Open Tender
Electrical Works
Works
730 days
Goa Airport
As per NIT
18 documents required · 18 mandatory
₹1,120
Airports Authority of India
₹25,980
27 Oct 2020
15 Sept 2020
14 Oct 2020
15 Sept 2020
8 Oct 2020
15 Sept 2020
15 Sept 2020 - 19 Sept 2020
Amount
Annual maintenance contract of 2 nos., 33KV HT Automatic Voltage Regulator (HT AVR) of 5000 KVA,3 phase, 50Hz AC capacity having an input voltage range from 27KV to 35KV and stabilized output voltage of 33KV +/- 1%, 3 phase, 50Hz AC including all accessories and protection devices including earthing terminals, drain valve, oil level indicator, conservator, explosion vent, buchholz relay, dial type temperature indicator etc. and including regular visit and breakdown call/visit within 48 hrs etc. as required as per instruction of Engineer-In-charge.
Supply of Spares etc. as follows as required time to time as per instruction of Engineer In-charge:-
PCB 1002/3 relay
Flip flop circuit
40 kg TOURQ, Step sys. Motor with gear, sprocket, resistance, capacitor etc. complete accessories as required
Power contactor, 800 Amps, 240V AC (Make: ABB or equivalent)
B4C limit switch
100/12 Balancer core & coil assembly
200/12 Balancer core & coil assembly
240 Volt, AC, Single phase auxiliary contactor (NCC)
240 Volt, AC, Single phase auxiliary contactor (RCC)
240 Volt, AC, Single phase auxiliary contactor (CFF)
240 Volt, AC, Single phase auxiliary contactor (CFL)
240 Volt, AC, Single phase auxiliary contactor (CM)
240 Volt, AC, Single phase auxiliary contactor (CC)
240 Volt, AC, Single phase auxiliary contactor (AC)
110 Volt, AC, Single phase auxiliary contactor (CLS)
240 Volt, AC, Single phase cutler hammer Timmer (0 to 60 sec)
Onetime repair & commissioning of 2nos, 33KV HT AVR including servicing/replacement of carbon roller assembly, B4C tag, limit switches, tail assembly with sleevings, HT bushings complete set, oil temperature indicator,33KV PTs and CTs, top up of transformer oil etc. to make the AVR completely serviceable, as required as per the instruction of Engineer In-charge
MAHADEV ENTERPRISE
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .