Loading…
Loading…
Tender Value
₹84.5 L
EMD Value
₹63,345
Closing Date
10 Jun 2026, 5:30 pm5d left
MR SE BRIDGE RAIGARH SANTOSH KUMAR SIDAR(DFLT)
CE(Bridge)
Special Repair of Mand River Bridge (Chandrashekhar Setu) on Kharsia-Adu-Chhal Road ( S.E.C.L.Bridge)
192285
NIT No.41/G. 2026-27 Dated :- 03.06.2026
RESTRICTED TENDER
WORKS
4 days
CE(Bridge)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
7 documents required · 7 mandatory
Public Works Department (PWD)
WORKS
MR SE BRIDGE RAIGARH SANTOSH KUMAR SIDAR(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C D
CE(Bridge)
Bridge Circle, Raigarh
Bridge Division Raigarh
120
04
No
30
192285
10 Jun, 2026 5:30:00 PM IST
15 Jun, 2026 11:00:00 AM IST
3 Jun, 2026 6:00:00 PM IST
NIT No.41/G. 2026-27 Dated :- 03.06.2026
Special Repair of Mand River Bridge (Chandrashekhar Setu) on Kharsia-Adu-Chhal Road ( S.E.C.L.Bridge)
63345.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
8446000.00
2
12 Jun, 2026 5:30:00 PM IST
8446000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
7d 3h 26m
7 documents required · 7 mandatory
₹0
₹63,345
3 Jun 2026
3 Jun 2026
15 Jun 2026
3 Jun 2026
10 Jun 2026
3 Jun 2026
12 Jun 2026
Scarifying Existing bituminous surface to a depth of 50 mm Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all leads & lifts.
Clearing Grass and Removal of Rubbish (clearing grass and removal of rubbish including all leads and lifts)
Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000m as per section 2811.
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry,cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in (i) Lime / Cement Concrete (c)Prestressed / Reinforced cement concrete grade M-20 &above
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorized representative ensuring compliance to the manufacturer's instructions for installation.)
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorized representative ensuring compliance to the manufacturer's instructions for installation.)
Sealing of cracks/porous concrete by injection process through nipples/Grouting complete as per Technical specification section 2806 (B) Cement mortar (1:1) Grouting
Patching of damaged concrete surface with polymer concrete and curing compounds, initiator and promoter, available in present formulations, to be applied as per instructions of manufacturer and as approved by the Engineer. (Av. thickness 25mm)
Drainage Spouts complete as per approved drawing and Technical specifications of section 2705
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700 (Newly laid concrete shall be covered by gunny bags). RCC Grade M 35 (II) For T-beam & slab (a) Using Concrete Mixer (iii) Height above 10m
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in super-structure complete as per drawing and technical specifications
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications as per section 1500,1700 & 2100. (A) Using batch type concrete mixer with integrated weigher. (i) PCC Grade M15
Replacement of damaged concrete railing (including Dismantling the old railing and disposal of dismantled material)
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment and cement Grouting with C.M. 1:4 in Pitching of gap between stone/block complete as per drawing and Technical specifications as per section 2504 (B) Cement Concrete Block of size 0.3x0.3x0.2 m cast in cement concrete of grade M15
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed as per section 2504
Tack coat Providing and applying tack coat with bitumen emulsion(RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. (iii) Cement concrete @ 0.35 kg/ Sqm
Mastic Asphalt (ii) Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-39, prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of 13.2 mm nominal size at the rate of 0.005cum per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces is not less than 1000C, protruding 1 mm to 4 mm over mastic surface, all complete as per clause 516.
Mastic Asphalt (ii) Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-39, prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of 13.2 mm nominal size at the rate of 0.005cum per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces is not less than 1000C, protruding 1 mm to 4 mm over mastic surface, all complete as per clause 516.
Painting on concrete surfaces with black and yellow alternate bands including cost of material and labour complete as per drawings and specifications as per clause 803. With Road Marking Paint
Painting on concrete surface of R.C.C. Railing (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.)
Granular sub-base as per table:-400-1 Construction of granular sub-base by providing close graded material, ,carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per caluse 401 A - Plant mix method (with Mechanically crushed stone only) (a) For Lower Sub-base with (iii) Grading-V Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per clause 502. (i) on WBM/WMM surface @0.85 Kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. (ii) Granular surfaces treated with primes @ 0.30 kg /Sqm
Dense Bituminous Macadam (Providing and laying dense graded bituminous macadam with 100-120 TPH capacity Batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects. B - With mechanical paver finisher (ii) for Grading II (26.5 mm nominal size bitumen content 4.50%)
Bituminous Concrete (Providing and laying bituminous concrete with minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.0 to 6.0% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects) (B) With mechanical paver finisher (iii) for Grading II (13.2 mm nominal size) with bitumen 6.0 %
Metal Beam Crash Barrier B Type - B, "THRIE" : Metal Beam Crash Barrier (Providing and erecting a "Thrie" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanized by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a space of channel section 150 x 75 x 5 mm, 546 mm long complete as per clause 811.3)
Providing & Fixing Hazard Marker Partial Reflective hazard marker as per clause 15.66 of IRC 67-2022, made of 16 gauge (1.6 mm) thick mild steel sheet Confirming to IS: 2062 Painted with one coat of Zinc Chromate Stoving Primer and two coats of Black Stove Enamel (Oven Baked) paint with 10 cm alternative bands of yellow Retro- Reflective Sheeting of Micro Prismatic Grade pasted as per IRC:79 and black paint, including back frame made of angle iron 25x25x3mm mounted over one MS angle Iron post of size 50X50X6 mm of 1.65 meter long duly painted with synthetic enameled paint block including bolts and fixing the same in M-15 concrete black of size 30X30X30 cm Including transportation etc. Complete (II) Two Way Object Hazard Marker Size 450x900mm A Made of Class-C Micro Prismatic Grade Sheeting of Type XI (for National Highways and State Highways)
Replacement of Elastomeric bearings complete as per Technical specification section 2810 (the work entails replacement of all the bearings on one side of span)
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.09 MB
3124640672003217109_187465_Form A 2.zip
NIT • 0.04 MB
380280576277972568_187465_Details NIT 2.zip
NIT • 0.05 MB
6427561545152941476_187465_on going.zip
NIT • 0.09 MB
9153382793567897411_187465_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
8334085464344027631_192285_Notice.zip
NIT • 0.04 MB
2141792456651784737_187465_RFQ.xlsx
BOQ • 0.03 MB
409961444045285233_187465_NIT.xlsx
BOQ • 0.03 MB
Download all tender documents and submit your bid