Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance AZAD NAGAR AZAD NAGAR HARDOI UTTAR PRADESH 241001 UDYAM UP 35 0017189 | HARDOI | UTTAR PRADESH | 241001 | Admitted-Finance |
| 3 | Admitted-Finance HARDOI VAIT GANJ HARDOI HARDOI HARDOI HARDOI UTTAR PRADESH 241001 | HARDOI | UTTAR PRADESH | 241001 | Admitted-Finance |
Tender Value
₹23.2 L
EMD Value
₹23,240
Closing Date
17 Aug 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDCH ASHA NAGAR HARDOI
SE EDCH ASHA NAGAR HARDOI
23/EDC(H)/2023-24
2023_MVVNL_828247_1
23/EDC(H)/2023-24
Open Tender
Miscellaneous Works
Item Rate
365 days
HARDOI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C No. 21342643946, IFSC Code IDIB000E504, India
₹23,240
7 Oct 2023
10 Aug 2023
18 Aug 2023
10 Aug 2023
17 Aug 2023
10 Aug 2023
Amount
Safe loading Carriage & unloading of following material from store centre to pit site/JE dump store.
PCC pole 8.5 mtr long.
ST pole 11 mtr. Long.
11 KV XLPE cable of size 3x185 sq.mm.
G.I Wire
Stay Set Complete
33 KV Pin with Net
Disc insulator With fitting (B&S) 70KN
MS Earthing Rod (2540x20 mm) With Fitting
11 KV Indoor Metering cubicle 5/5 10/5 15/5 25/5amp
11/0.4 KV T/F 250/ 400/ 630 KVA
11/0.4 KV T/F 100 KVA
11/0.4 KV T/F 63 KVA
11/0.4 KV T/F 25/16/10 KVA
11 KV outdoor, pole mounted CT/PT. unit.
ACSR Weasel Conductor
Rabbit Conductor
Line Material
Cable box 3x70/3x120/3x185x3X185 3x300 Indoor & Outdoor
Erection of PCC 8.5 mtr long single pole with Grouting & with all accessories
Erection of PCC 8.5 mtr long double pole with Grouting & with all accessories
Erection of STP 11 mtr long single pole with Grouting & with all accessories
Erection of STP 11 mtr long double pole with Grouting & with all accessories
Fabrication & Erection of cable stand made of two nos MS Channel 100x50x3 mtr. Long jointed to each other by means of 5nos MS Strip 50x6mm of size 150mm long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamps also. all the materials i.e. clamps nut bolts will provide by contractor.
Grouting and Nozzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (sand, brick blast & cement). All material except stay wire shall be suppled by the contractor
Ordinary earthing by 11 KV MS earth Rod 2500 mm long as per RESPO schedule. All material except earthing rod shall be supplied by the contractor.
Complete jumpering with help of Gl pipe as per RESPO norms GI pipe and other required 45 material shall be supplied by contractor.
Laying of 11KV 3X185 sqmm single XLPE cable by digging of trench size 500 mm wide 900 mm 480 after laying of brick, sand and stone slab
Installation of 11 KV CT/PT double metering unit of constructed double pole structure as per RESPO norms. Only 11 KV CT/PT unit shall be supplied by department
Fixing & commissioning of 11 KV pilfer CT Unit (5/5 10/5, 15/5 25/5Amp.) All material except pilfer CT Unit cubical shall be supplied by the contractor.
Earthling by way of Boring and lowering the "B" class Gl pipe (Jindal) of 50mm dia from ground upto water level not less than 20mtr as per standard practice.
Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1:5.10 cement sand and brick ballast on the top of padding brick work ist class brick of 0.95 mtr height & 0.35 mtr wall will be constructed, Rest wall should be 0.23 mtr thick, Brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be filled from the ground level up to 15 centimetres below from the top of wall, Cement, sand & brick Ballasts should be filled up to 15 centimetre. Two no, of channel 100x50 in length 1500mm will be) grouded 0.35 CM RCC will be done with cores sand, cement and stone ballast in the ratio of 1:24. The T/Fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand (All the material to be arranged by the contractor.)
Placement of 11/04 KV TIFS from dump place to newly constructed T/Fs plinth & installation, commissioning of 100/250/400/630 KVA T/FS of T/F Plinth and including jumpering with the system (All the required martial for above job shall be provided by contractor except T/Fs)
Fabrication erection & commissioning of 100 KVA T/F on Double pole with all accessories. All material except 100 KVA T/F
Fabrication erection & commissioning of 63 KVA T/F on Double pole with all accessories. All material except 63 KVA T/F shall be supplied by the contractor
Fabrication erection and commissioning of 25/16/10 KVA TIF on double/single pole with all accessories. All material except 25/16/10 KVA T/F shall be supplied by the contractor.
Stringing & Sagging of three phase 11 kv line
Construction of toe wall around the 11/0.4 kv S/S fuse unit size 0.75 Mt. At Base and 0.23 Mt. At top as per RESSPO Norms by Ist class bricks in the ratio 1:6, Base concreting of the wall to be done in ratio 1:6:12 and plaster 12 mm thick in ratio 1:4.& fabrication of fencing with wire mesh 10SWG(37mmx50mm)(all material to be arranged by contractor
Installation of cable box 11 KV Indoor & Outdoor
Looping & chopping of tree branches for clearance of HT/LT line after clearance of line throughout pieces of tree branches of site (Approx 3 Km).
M/S S.K. CONTRACTOR AND SUPPLIER
Neeraj Electricals
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .