Er. Gurpreet Singh Bhains
Office of the Executive Engineer, Electrical Division No. 1, Sector-9,Chandigarh.
RENOVATION OF ELECTRICAL INSTALLATION AROUND THE STRONG ROOM, GALLERY AND GUARD ROOM IN CENTRAL TREASURY, SECTOR-17,CHANDIGARH.
2025_CHD_89743_1
E1/TN-449
Open Tender
Electrical Works
Percentage
30 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10,500
24 Dec 2025
24 Dec 2025
31 Dec 2025
24 Dec 2025
31 Dec 2025
24 Dec 2025
DSR Item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.
Group C
DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/ HFFR PVC insulated copper conductor single core cable etc. as required.
Group C
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
DSR Item No. 1.17 Supplying and drawing following sizes of FRLS/ HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 Pin 5/6 A. socket outlet
DSR item No.1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
DSR item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
DSR item No.1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
DSR Item No. 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
DSR item No.1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
DSR item no. 8.6.11 LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 13 of the DNIT).
DSR item no.8.9.5 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%,(As per Complete Item No. 14 of the DNIT).
DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, (As per Complete Item No. 15 of the DNIT).
4 way (4 + 12), Double door
DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
DSR item no. 8.12.13 LEDStreet lightfixture, powdercoatedpressurediecast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying,installation, (As per Complete Item No. 17 of the DNIT).
DSR item no. 9.2.3 BrushLessDirectCurrent(BLDC)FanwithoutRemote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, (As per Complete Item No. 18 of the DNIT).
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
S/E of Thermo Plastic cable Jn. Box IP55/65 of size 155 X 210 X 92 deep (approximate) with 4 nos. thermal block suitable for 1 no. incoming and 3 nos. outgoing cables.( As per Complete Item No. 19 of the DNIT).
S/E of GI pipe bracket of 32 mm dia welded with nipple for erection of existing street light fittings to be installed on wall with suitable size of rag bolts and MS clamps made out of 25 mmx 5 mm thick MS flat with all labour and material.( As per Complete Item No. 20 of the DNIT).
Supply and fixing extra down rod of 15 mm dia G.I. pipe length to fix the ceiling fan. The job includes cost of cutting, making holes and cutting groove in pipe for proper tightening of rod to the fan motor.
DSR item No.2.2.13 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
100A,30KA,FPMCCB
Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing, ( As per Complete Item No. 23 of the DNIT).
Size 12” Sweep 900 RP. MTR. with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make HDEF EXHD 300-6-1/ Bajaj make Supreme PLUS only.
Size 15” Sweep 900 RP. MTR. with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make HDEF EXHD 380-6-1/ Bajaj make Supreme PLUS only.
Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. ( As per Complete Item No. 24 of the DNIT).
Size 10 Sq.mm 4 Core XLPE Al. Arm. Cond. Cable
Supply and Erection of B.L. Holder of make Anchor Panta / Havells Reo/ Gold Medal Essenza ISI marked on existing Jn. Box / Wooden block including making connection etc. as required.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_109768.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .