| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹28.7 L+₹98,510 (3.55%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L2 | Rejected-Finance not become lowest bidder | |
| 3 | L3₹33.0 L+₹5.2 L (18.7%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L3 | Rejected-Finance not become lowest bidder | |
| 4 | L4₹33.5 L+₹5.7 L (20.5%)Rejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance not become lowest bidder | |
| 5 | L5₹33.9 L+₹6.1 L (22.0%)Rejected-Finance D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-Finance not become lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Sept 2022, 6:00 pmClosed
Lt Col Deepak Kumar
Garrison Engineer Jhansi
REPAIRS AND RENEWALS TO MCB DBs, MCBs, SERVICE CONNECTIONS, SUB MAIN WIRING, REWIRING WORKS AND CONNECTED ITEMS AT JHANSI CANTT UNDER AGE E/M AT GE JHANSI
2022_MES_548516_1
GE/JHA/TOK/30 OF 2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Jhansi
₹80,000
Yes
3 Nov 2022
29 Aug 2022
26 Sept 2022
29 Aug 2022
24 Sept 2022
10 Sept 2022
Amount
Taking down existing unserviceable DBs (VTPN/ TPN) along with MCCBs and MCBs of any capacity for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engineer-in-Charge.
Taking down existing unserviceable DBs (SPN) along with MCBs of any capacity for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCCB / MCB distribution board, Vertical TPN, 4 way with provision of suitable MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCCB / MCBs shall be measured and paid separately.
Supply and fix MCB distribution board, TPN, 4 way 415 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
All as per srl item No. 4 here-in-before but SPN 12 way 230 Volt complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 4 here-in-before but SPN 08 way 230 Volt complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 4 here-in-before but SPN 04 way 230 Volt complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCCB 125, 16 KA, 4Pole, 415 V, 50 Hz with fixed thermal magnetic release complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCCB 100, 16 KA, 4Pole, 415 V, 50 Hz with fixed thermal magnetic release complete all as specified and directed by Engineer-in-Charge.
S& F MCB TPN 100 Amp, 10 KA, 'C' curve, 415 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.
S& F MCB TPN 63 Amp, 10 KA, 'C' curve, 415 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 9 here-in-before but SPN 63 Amp complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 9 here-in-before but SPN 40 Amp complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 9 here-in-before but 6 to 32 Amp, Single Pole 230 Volt complete all as specified and directed by Engineer-in-Charge.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 6 sqmm + 1 run x 6 sqmm with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length.
All as per srl item No. 15 here-in-before but 2runsX4 Sqmm +1runX4Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item No. 15 here-in-before but 2runsX10 Sqmm +1runX10 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
Notes for item No. 15.00 to 17.00 (i) Quoted rate shall deemed to incude the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & caping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing caping may be used in that portion.
Supply and fix in replacement of MCCB 125A, 16KA, 4 Pole with fixed thermal magnetic release mounted in MCCB sheet steel enclosure including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB 100A, 16KA, 4 Pole with fixed thermal magnetic release mounted in MCCB sheet steel enclosure including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge.
Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 35 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing service cable of any description complete all as specified and directed.
All as per srl item No. 21 here-in-before but 25 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 21 here-in-before but 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 21 here-in-before but 16 sq mm 2 core complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections. including connecting on LT OH line / energy meter / DB etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix Rigid PVC conduit of size 25mm dia inclusive of boxes (junction/ terminal) of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc including cutting the wall surfaces for flush mounting of pipe and making good with cement plaster, putty and paint to match with the existing surface complete all as spexified and directed by Engineer-in-Charge.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of cable and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to 25 x 4 mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply and fix in replacement of Hot Press Molded SMC meter box of size not less than 700mm x 480mm x 210mm for accommodating 04 Nos of Single Phase energy meters including cutting the wall surfaces for flush mounting of meter box and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
HARNAM SINGH ANIL SINGH
ROHIT ENTERPRISES
M/s JS Constructions
FTH Traders
M/s Pooja Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .