Executive Engineer RNB Electric Division Srinagar
Executive Engineer RNB Electric Division Srinagar
Internal Electrification of Community Hall at Khonmoh Srinagar
2022_PWDJK_168737_1
E/NIT/15/2022/23dtd09/05/2022
Open Tender
Electrical Works
Item Rate
20 days
Internal Electrification of Community Hall at Khon
as per BOQ
2 documents required · 2 mandatory
₹600
Executive Engineer RNB Electric Division Srinagar
₹20,960
14 May 2022
9 May 2022
14 May 2022
9 May 2022
14 May 2022
9 May 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (incl cost of conduit & circuit wiring from DB Box to first switch in sub circuit (Long and extra long poits)
Wiring for Power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required ( (incl cost of conduit & circuit wiring from DB Box to first switch in sub circuit ,(max two points to be provided one circuit from DB Box) (Long and extra long poits)
Wiring for 6 Amp Socket Out Points 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required ( (incl cost of conduit & circuit wiring from DB Box to first switch in sub circuit ,(max two points to be provided one circuit from DB Box) (Long and extra long poits)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supply and Fixing of two module stepped type Electronic Fan regulatot on the existing modular plate switch box including connections but excl cosat modular plate etc as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable to be laid through surface/ recessed medium class PVC conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 10 sq. mm + 1 X 10 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single Pole
Supplying and fixing 40-63 Amp 240/415V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A
Supplying and fixing 32 Amp 240/415V, 2 Module Change over Switch fitted in excisting D Box incl making of necessary connections
Supply and Fixing of Neon Indicator Modular Switch Series incl its Frame Plate, cover plate and G I Box of required size
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply of 12 Watt Surface mounted Slim / Recessed type LED Fixtures.
Supply of 14 Watt Batten Type Al Base LED Light Fixture of standard make
Supply of 1400 mm sweep Ceiling Fans complete in all respects.
Supply of 300 mm sweep Exhaust Fans with steel body and steel blades incl wire guage shutter fron out side complete.
Supply of 36 watt LED Flood Light made of pressure die cast Aluminum Housing with high power LEDs, Lens & Toughened glass IP66
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
Upto 450 sweep
Supplying and fixing of following sizes of medium class PVC conduit /Double lock channel along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Design, Fabricataion, assembly, Installation, Testing and Commissioning of Front Operated Cubicle type compartmentalised as per form 3B free standing, dust and verim proof (IP 42 ingress protection) LT panel suitable for use of 415 volts, 3 Phase 4 wire 50Hz suitable for a fault levewl of 55kA at 415 volts, fabricated from 2 mm thick Powder coated paint finish of approved shade CRCA MS sheet with hinged, gasketted9 metal based neoprene) and lockable doors having structral reinforcement with suitable angle/ chanel/T / Flat section uncl gland plates as requiredand lifting hooks with sleeved TPN AL Busbars and G I strip of required size with 2 no earthinmg terminals complete with interconnections as required for MCB`s and control wiring. Each incoming / out going breakers shall have thermal megeatic release. The panel will be made as oper detailed specifications and drawings formating part of this document. Incomer Normal :- 1 No 250 Amp TPN MCCB with beaking capacity 36kA with thermal release and adjustable settings. 1 Set of R,Y,B Phase indicating lamps 1 No MFM with 630/5CT coils 1 Set of 400 Amp TPN Alluminum Bus Bar with colour coding sleeves Incomer Generator :- 1 No 100 Amp Four pole change over switch 1 Set of R,Y,B Phase indicating lamps 1 No MFM with 630/5CT coils 1 Set of 200 Amp TPN Alluminum Bus Bar with colour coding sleeves Out Going :- 4 No of 63 Amp D Pole MCB`s for haeting laod 8 No 40 Amp D P MCB`s for normal lif=ghting oad and AC Point 4 No 40 Amp D P MCB`s for normal lif=ghting oad and AC Point
Supply, laying, jointing, terminating, testing and commissioning of 95 sq mm 3.5 Core 1100 V grade, armoured, FRLS, XLPE, aluminum(AL) conductor cables of Havel's / Polycab / Universal / Fort Gloster on existing trays/walls/columns/ trenches including the cost of supports with suitable clamps, saddles, hooks, bolts etc. and including the cost of proper dressing of cables, markers providing identification tags, earthing of glands armouring etc complete.
Chemical Earthing with 2 mts long GI electrode to 50 mm dia G I Pipe placed verticaly in 100 mm dia bore dully drilled with hand drill and filed with required quantatity of chemical and man hole cover at top. The job includes extending of Earthing fron Eart Electrode to Main L T panel with 25x5 mm G I Strip in one run
Supply, installation, testing & commissioning of 2000 VA Digital UPS/ inverter sine wave with technical specification of Rating=2 KVA having 24 volt, voltage=230V, of frequency 50Hz, efficiency on Battery mode>90%, short circuit protection 300%, charger of constant current/constant wattage & charger current of 10% of exide make Digital sine wave UPS having DC voltage The job includes providing and fixing of 2 no.s ,12v EL-Tall Tubular batteries 180 AH with 4 years warranty Exide batteries) with pvc trolley for housing of batteries complete job.
Supply,Installation,Testing & Commissioning of 10 KVA, single phse , automatic Servo voltage stabilizer operating from AC Input voltage of 90 to 260 volts thereby producing desired out put voltage (230 volts ± 5% ) (Alba/Chinar/ Electrified ).The job includes AMC of batteries and invertor for a period of three years ,whic includes quarterly servicing of devices & as and when required. complete job.
AAY SQUARE AND SONS
TALIE ELECTRICALS PROP SHOWKAT AHMAD TALIE
GUROO ELECTRICAL ENGINEERS
M/S YOUSUF ENGINEERING WORKS
M/S AXIS ENGINEERS
M/S ALAMDAR ELECTRICALS
Sabtech Engineering Works
M/S Y R Electrical and Mechanical Works
JMC TRADERS
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .