| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹20.5 L+₹1.2 L (6.23%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹20.6 L+₹1.4 L (7.13%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹23.4 L+₹4.2 L (21.6%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹23.6 L+₹4.4 L (22.6%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
| Sl No | Description | Qty | Unit | Ms Kamal Kant Agarwal L2 | DEMROT ELECTRICAL WORKS L6 | DEVI DAYAL CONSTRUCTION CO L1 | LOKESH ELECTRICAL L5 | ASHOK INFRATECH L4 | M/S S S CONSTRUCTION L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Bus Bar Chamber outdoor type made out of 1.6 mm CRCA steel sheet 8 Nos outgoing TPN 200 Amps Bus Bar rating including fixing on Wall / Pole with suitable size of clamp, Nut & Bolt or as per site requirement for fixing of outdoor site with provision of angle iron legs 45 x 45 x 3 mm, 750mm long including PCC 1:2;4 type B-1 as in foundation of size 450 x 600 x600mm for grouting and incommer and outgoing cable connections with suitable size of lugs complete all as specified and directed . | 3 | Each Job | 7,000 ₹21,000 | 10,000 ₹30,000 | 6,000 ₹18,000 | 5,000 ₹15,000 | 3,000 ₹9,000 Lowest | 4,000 ₹12,000 |
| 2.00 | Supply and laying electrical insulation rubber mating for installations of size 1mx2mx25mm thick as per latest IS complete all as specified and as directed. | 4 | Each | 1,500 ₹6,000 | 2,500 ₹10,000 | 1,000 ₹4,000 Lowest | 1,400 ₹5,600 | 1,000 ₹4,000 Lowest | 1,800 ₹7,200 |
| 3.00 | Supply and laying electrical insulation rubber mating for installations of size 1mx2mx20mm thick as per latest IS complete all as specified and as directed. | 4 | Each | 1,000 ₹4,000 Lowest | 2,000 ₹8,000 | 1,000 ₹4,000 Lowest | 1,200 ₹4,800 | 1,500 ₹6,000 | 1,800 ₹7,200 |
| 4.00 | Supply, installing, commissioning and testing of LT panel board outdoor type, cubical type made out CRCA sheet 3.15 mm thick, inner sheet 2.0 mm thick, dust and vermin proof as per IS/IEC-:61439-1:2011, 61439-2:2011 having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete complete with suitable size of aluminium bus bar - 03 Nos for Phase and 01 No for neutral, (in separate chamber) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 350 Amp,4P, 36KA adjustable thermal and adjustable magnetic (I/C)- 01 No
(b) MCCB 100A, 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 01 No
(c) MCCB 63 Amp, 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)= 05 Nos
(d) Digital meter with Voltmeter (0-500V) - 01 No
(e) Rating of CT & Ammeter as per Bus bar capacity as mentioned in BOQ
(f) Selector Switch for Ammeter (R,Y & B) - 01 Set
(g) Selector Switch for Voltmeter (RY,YB & BR) - 01 Set
(h) Indicationg Lamps (R,Y,B) - 01 Set | 2 | Each job | 25,000 ₹50,000 Lowest | 1,00,000 ₹2,00,000 | 45,000 ₹90,000 | 40,000 ₹80,000 | 80,000 ₹1,60,000 | 30,000 ₹60,000 |
| 5.00 | Supply, installing, commissioning and testing of LT panel board outdoor type, cubical type made out CRCA sheet 3.15 mm thick, inner sheet 2.0 mm thick, dust and vermin proof as per IS/IEC-:61439-1:2011, 61439-2:2011 having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete complete with suitable size of aluminium bus bar - 03 Nos for Phase and 01 No for neutral, (in separate chamber) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 160 Amp,4P, 25KA adjustable thermal and adjustable magnetic (I/C)- 01 No
(b) MCCB 63A, 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 06 Nos
(c) Digital meter with Voltmeter (0-500V) - 01 No
(d) Rating of CT & Ammeter as per Bus bar capacity as mentioned in BOQ
(e) Selector Switch for Ammeter (R,Y & B) - 01 Set
(f) Selector Switch for Voltmeter (RY,YB & BR) - 01 Set
(g) Indicationg Lamps (R,Y,B) - 01 Set | 2 | each job | 20,000 ₹40,000 Lowest | 1,00,000 ₹2,00,000 | 50,000 ₹1,00,000 | 40,000 ₹80,000 | 65,000 ₹1,30,000 | 35,000 ₹70,000 |
| 6.00 | Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundation of poles, laying of cables etc. and getting out in soft/loose soil complete all as specified and as directed. | 1,033 | Cum | 80 ₹82,640 | 150 ₹1,54,950 | 90 ₹92,970 | 60 ₹61,980 | 40 ₹41,320 Lowest | 70 ₹72,310 |
| 7.00 | M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable and punned the sand for protection of cable complete all as specified and as directed.
Note:- For payment punned depth shall be measured. | 310 | Cum | 250 ₹77,500 | 300 ₹93,000 | 400 ₹1,24,000 | 100 ₹31,000 Lowest | 250 ₹77,500 | 100 ₹31,000 Lowest |
| 8.00 | Supply and laying reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150mm x 40mm complete all as specified and as directed. | 25,500 | Each | 5 ₹1,27,500 | 20 ₹5,10,000 | 4 ₹1,02,000 Lowest | 10 ₹2,55,000 | 7 ₹1,78,500 | 4 ₹1,02,000 Lowest |
| 9.00 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and as directed | 616 | Cum | 20 ₹12,320 | 50 ₹30,800 | 20 ₹12,320 | 20 ₹12,320 | 10 ₹6,160 Lowest | 25 ₹15,400 |
| 10.00 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. | 417 | Cum | 18 ₹7,506 | 50 ₹20,850 | 30 ₹12,510 | 20 ₹8,340 | 10 ₹4,170 Lowest | 20 ₹8,340 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
17 Dec 2025, 6:55 pmClosed
Garrison Engineer (East) Mathura
GE (East) Mathura
REPAIR/MAINTENANCE OF LT SWITCHGEARS, LT PANELS, LT CABLES AND CONNECTED ITEMS AT VARIOUS LOCATION UNDER GE(E) MATHURA MIL STN
2025_MES_741854_1
1543/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (E) Mathura
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (E) Mathura
₹1 L
Yes
19 Jan 2026
27 Nov 2025
19 Dec 2025
27 Nov 2025
17 Dec 2025
11 Dec 2025
27 Nov 2025 - 11 Dec 2025
Amount
Supply, installation, testing and commissioning of Bus Bar Chamber outdoor type made out of 1.6 mm CRCA steel sheet 8 Nos outgoing TPN 200 Amps Bus Bar rating including fixing on Wall / Pole with suitable size of clamp, Nut & Bolt or as per site requirement for fixing of outdoor site with provision of angle iron legs 45 x 45 x 3 mm, 750mm long including PCC 1:2;4 type B-1 as in foundation of size 450 x 600 x600mm for grouting and incommer and outgoing cable connections with suitable size of lugs complete all as specified and directed .
Supply and laying electrical insulation rubber mating for installations of size 1mx2mx25mm thick as per latest IS complete all as specified and as directed.
Supply and laying electrical insulation rubber mating for installations of size 1mx2mx20mm thick as per latest IS complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundation of poles, laying of cables etc. and getting out in soft/loose soil complete all as specified and as directed.
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable and punned the sand for protection of cable complete all as specified and as directed. Note:- For payment punned depth shall be measured.
Supply and laying reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150mm x 40mm complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and as directed
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, steel tape / wire armoured heavy duty electric underground cable, 1100 volts grade with stranded aluminium conductor of following nominal cross sectional area including taking down old unserviceable cable:- Note:- Excavation, returning and removal shall be paid and measured seperately under respective item of BOQ from Sr No 12 to 21
16 Sqmm 4.0 core.
25 Sqmm 3.5 core.
35 Sqmm 3.5 core.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
150 Sqmm 3.5 core.
185 Sqmm 3.5 core.
240 Sqmm 3.5 core.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 Sqmm to 35 Sqmm complete all as specified and directed.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as directed.
Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
M&L for copper earthing in replacement with copper earth plate electrode 90 cm X 60 cm X 3.15 mm buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 20 X3 mm as earthing strip by means of bolts,nut check nut and washers protected with and including 40 mm dia medium grade GI pipe,necessary excavation and earth work,magnesium sulphate (80 Kg) ),charcoal (2 Qtl) and common salt (2 Qtl) filling,watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover ,GI funnel with test point,testing (all as shown in electrical plate No 5 and commissioning all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main panel/eqpmt, pole/bus bar etc, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost complete. Note: GI strip beyond 7.5Mtr length from earth electrode shall be measured and paid separately).
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle.
Supply and laying GI Pipe light grade with all fitting and fixed complete to walls/poles/underpass and ceilings or laid in floors complete all as specified and directed of following sizes in item no 30 and 31
80 mm bore
100 mm bore
Excavation in post hole (or similar hole) each n exc 0.5 cum,getting out,returning,filling in and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25 cm in soft/loose soil.
M&L for providing cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in foundations,filling and mass concrete.
Supply only chain link fencing made out of mild steel galvanised wire of any size all as specified and directed.
Fixing only chain link fencing including line wires,any mesh,sizes and type to any type of strandards,rail,straining bolts etc including provision of binding wire complete all as specified and directed. Note:- (i) Supply only fencing will be measured and paid separately. (ii) Supply and fix mild steel nut bolt,line wire and flat will be measured and paid separately.
Supply and fix mild steel section fin post and struts for fencing including cutting top to shape as directed drilling hole notching for wire etc or flat iron fillet (for security wire mesh etc) including all necessary drilling bolting or riverting etc complete all as specified and directed.
Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends,each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long & dia of shank 11 to 15 mm compele all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise desenbed and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified.
Supply and fixing in replacement of MCCB 630Amp rating,4-pole 415V, Electronic release with overload and short circuit adjustable type breaking capacity 36 KA.
Supply and fixing in replacement of MCCB 400Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA.
Supply and fixing in replacement of MCCB 315 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA.
Supply and fixing in replacement of MCCB 250 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA.
Supply and fixing in replacement of MCCB 200 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA.
Supply and fixing in replacement of MCCB 160 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA.
Supply and fixing in replacement of MCCB 100 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA.
Supply and fixing in replacement of MCCB 63 Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal fixed megnetic type breaking capacity 16KA.
Supply and fixing in replacement of MCCB 250Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA.
Supply and fixing in replacement of MCCB 200Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA.
Supply and fixing in replacement of MCCB 160Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 25KA.
Supply and fixing in replacement of MCCB 125Amp rating,3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 25KA.
Supply and fixing in replacement of MCCB 100Amp rating,3-pole 415V, fixed thermal fixed megnetic type breaking capacity 16KA.
Supply and fixing in replacement of MCCB 63 Amp rating,3-pole 415V, fixed thermal fixed megnetic type breaking capacity 16KA.
Cutting wild grass, bushes, creeper, unwanted vegetation from inside / surrounding of E/M sub station (transformers) including cutting creepers from barbed / cattle fencing of the sub stn of area not exceeding 300 Sqm as when directed and removing of unwanted material from installation fencing/compound and depositing where directed after taking proper electric shutdown form MRS Mathura. Note :- The item shall be operated maximum two times in entire period of contract in the same installations. (Area measured separately each time).
Ms Kamal Kant Agarwal (BID ID -3507074)
M/S S S CONSTRUCTION (BID ID -3507085)
ASHOK INFRATECH (BID ID -3500130)
LOKESH ELECTRICAL (BID ID -3500738)
DEMROT ELECTRICAL WORKS (BID ID -3507076)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tender.pdf
Tender Documents • 0.80 MB
BOQ_830719.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .