Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.5 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹17.0 L+₹26,308 (1.58%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | 2 | Rejected-Finance OTHER THAN L1 | |
| 3 | 3₹17.3 L+₹61,941.50 (3.71%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | 3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹17.8 L
EMD Value
₹35,600
Closing Date
22 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE SHILLONG
CWE SHLLONG, SE FALLS, SHILLONG-11
SPL REPAIR TO BLDG NO P-438 AT UMROI UNDER GE UMROI
2020_MES_345131_1
8403/UMR/E8
Open Tender
Civil Works
Item Rate
180 days
UMROI
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE UMROI
₹35,600
Yes
6 Jul 2020
26 May 2020
24 Jun 2020
26 May 2020
22 Jun 2020
9 Jun 2020
60 days
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, walls etc, laid , bedded and pointed in any mortar and removing rubbish off the premises etc complete all as directed.
M&L screed bed or bedding laying of cement mortar (1:4), 15 mm thick for as in floor finishes, complete all as specified and as directed.
M&L for backing coat of cement mortar 1:4, 10 mm thick for as in vertical surfaces such as skirting , dados etc, complete all as specified and as directed.
M&L for joint free non-skid coloured ceramic tiles 9 to10 mm thick (size of each tile 600 x600 mm) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified . Note : Screed bed shall be measured and paid separately.
All as per item No 04 above but as skirting etc complete all as specified and directed.
S&F Coloured non skid ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified . Note : Screed bed shall be measured and paid separately.
Supply & Fixing of glazed ceramic coloured /printed tiles 300x200x7mm/350x250x 7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match on vertical surface of wall complete all as specified and as directed. Note : backing coat shall be measured and paid separately.
M&L screed bed or bedding laying of cement mortar (1:4) 20 mm thick for as in floor finishes, complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed. Note : Screed bed shall be measured and paid separately.
M&L for Machine cut kota stone in riser of steps 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. Note : Screed bed shall be measured and paid separately.
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of other than white and black, complete all as specified and directed. Note : Screed bed shall be measured and paid separately.
M&L for Granite work 18-20mm thick of any type (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade, complete all as specified and directed. Note : Screed bed shall be measured and paid separately.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards / slabs/ blankets, any thickness, including fillets, complete all as specified and as directed.
Dismantling rails, posts, rafters, purlins, etc in framed work, under 40 sqcm in section, complete all as specified and as directed.
Providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel section (Galvanized @120 grams, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and cross 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from trusses/ceiling using suitable suspension arrangement as per manufacturers instructions/literature, GI adjustable wire of 4mm dia with galvanized butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at centre of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engr-in-Charge.
Taking down cement plaster from brick/concrete surface including racking out joint hacking for key scrubbing down with water etc and removing rubbish off the premises etc complete all as directed.
M&L for 15mm thick rendering in CM (1:4) in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick finishing the surfaces with fair and even without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
Supply only integral water proofing compound
M&L for Rendering 10mm thick on fair faces of brickwork or concrete surfaces in cement mortar (1:6) on concrete surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for Rendering 5mm thick on fair faces of concrete surfaces in cement mortar (1:3) finished even and smooth without using extra cement, as in ceiling, complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall any description and applying two coats exterior acrylic emulsion paint ( 1st quality) over a coat of white cement based wall care putty (minimum 1.5mm thick) and suitable primer all as specified and directed.
M&L for Complete removal of existing treatment of plastered surfaces of wall, washing rubbing down and applying two coats exterior emulsion paint ( 1st quality) over a coat of white cement based wall care putty (minimum 1.5mm thick) and suitable primer etc all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over white cement based wall care putty (minimum 1.5mm thick) over a coat of cement alkali resistant/cement primer complete all as specified and as directed.
M&L for Complete removal of existing treatment of plastered surfaces of wall, and applying white cement based wall care putty (minimum 1.5mm thick) over a coat of alkali resistant/cement primer and preparation of surface and applying two coats of oil emulsion distemper , complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of whitewash, complete all as specified and as directed.
M&L for preparing old plastered surfaces of ceilings and applying two coats of white wash, complete all as specified and as directed.
S&F in repairs 20 mm harrison rails, anodised aluminium alloy, with fixing brackets, stops, rollers etc. complete all as specified and as directed.
S&F in repair aluminium anodised brackets for curtain rod complete all as specified and directed
Demolition of unreinforced cement concrete of any description and in any position not otherwise specified and removing rubbish off the premises etc complete all as directed.
M&L for 75 mm thick Cement concrete type C 2, 1:3:6 (using 40 stone aggregate) in plinth protection, finished even and smooth without using extra cement, including provision of joints and filling the same with bitumen mastic complete all as specified and as directed.
M & L PCC 1:3:6 type C2 ( using 40 mm graded crushed stone aggregate) as in surface channel and drains, complete all as specified and directed
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
Taking up or down steel tubing and connection 20 mm bore, including cleaning for re-fixing or removal to store, complete all as specified and as directed.
S&F GI pipe medium grade 20 mm bore in wall and ceiling or laying in floors, including new fittings as required complete all as directed
Refixing old steel tubing and connections in new or old position ( walls, ceiling, floor etc) in 20mm bore including new fittings as required complete all as specified and directed
Taking up or down steel tubing and connection 15 mm bore, including cleaning for re-fixing or removal to store, complete all as specified and as directed.
Cutting chases for concealed pipe where required and pointing in cement mortar 1:3 etc. in brick walls for bore of pipe 15/20 mm and making good etc. complete all as specified and directed.
Supply & Fixing Tubes medium grade, 15mm bore galvanised with all fittings and fixed complete (concealed) to wall and ceiling or laid in floors Complete all as specified and directed. Note : Chasing and cutting shall be measured and paid separately.
Refixing old steel tubing and connections in new or old position ( walls, ceiling, floor etc) in 15 mm bore including new fittings as required complete all as specified and directed
S&F in repairs 500 litres capacity rotational moulded polyethene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as directed.
S&F 20 mm bore gun metal, glove or gate valves with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern ),including all fittings, heads, shoes, bends, swan necks etc. including cleaning or refixing or removal to store, complete all as specified and as directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore, complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore, complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore, complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore, complete all as specified and directed.
S&F PVC (SWR) single T equal or unequal with access door 110mm bore, complete all as specified and directed.
S&F PVC (SWR) single T equal or unequal with access door 75mm bore, complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore, complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore, complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm bore, plain with grating including jointing with solvent cement complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) not exceeding 1.5 sqm each and making good the disturbed surfaces and removing unserviceable materials from site of work complete all as directed by the Engineer-in-Charge.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exceeding 1.5 sqm and not exceeding 4 sqm each and making good the disturbed surfaces and removing unserviceable materials from site of work complete all as directed by the Engineer-in-Charge.
S & F in repair of Prelaminated particle board 18/19 mm thick, BWP, bonded with phenol formaldehyde synthetic resin, confirming to IS: 12823 grade-I, as in Cupboard interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified. :Make : Greenply Industries Ltd (Ply & Board division)/Kitply/Century/Archid Ply/National Plywood Inds Pvt. Ltd
S & F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip if 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail ; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles. & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification & drawing.
S & F for solid PVC door frame of size 50mm X 47 mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube supplying and fixing in opening as per specification and drawing complete all as specified and directed.
M & L for plain Cement Concrete Type C1 1:2:4 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
S & F 100 mm long medium weight, cold rolled mild steel butt hinges complete all as specified and directed.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150mm aluminium anodised bow handles complete all as specified and directed.
S&F bands, straps, supports or stays for rainwater, large hasp and staple, chains, clamps, hold fasts, wall ties etc and small articles confirming to Fe290 Gde-E-165, complete all as specified and as directed.
S&F PVC connection 15mm size with PTMT nuts of length 600mm, complete all as specified and as directed. Make : Prayag/Polytuf
Cutting channels, grooves or rebates not exceeding 15cm girth and treating surface, with or without reinforcement, complete all as specified and as directed.
S&F in repairs 15 mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S & F 125mm size brass chromium plated shower rose with or without swivel joints with arm, fixed to steel pipe or union of 15mm bore fixed as in repairs complete all as specified and as directed.
Supply & Fixing Vitreous china wash hand basin size 550x400mm (flat back or angle back type) including 32mm dia brass chromium plated waste fitting a pair if cast iron bracket duly painted including cutting and pinning in ends making good disturbed surfaces in CM 1:3 including taking down unserviceable wash hand basin and connected items of any description, complete all as specified and as directed.
S & F in repair 32 mm Bottle trap of PTMT having minimum water seal of 25mm. (Minimum weight 32mm-260gms/40mm-270 gms) all as specified and directed. Make : Prayag/Polytuf
S & F Central hole basin mixer with regular spout without popup waste system with 450 mm long braided hose, with fixing accessories set complete all as specified and as directed. Make: Jaquar Cat. No. QQT-7167B or equivalent of make Parryware/Cera/Hindware.
S & F chromium plated tubular towel rail, 20mm dia, ‘D’ type, 60cm long between flanges including brass chromium plated brackets and chromium plated brass screws and wooden/plastic cleats and fixed as in repairs complete all as specified and as directed.
S&F Toilet roll holder with flap, with accessories set , complete with all accessories set as specified and as directed by Engr-in-Charge. Make : Jaquar Cat Part No. AQN-7753 or equivalent in Marc/Kohler/ Parryware/Gorhe/Crabtree
S&F in repairs Vitreous china wash down water closet pan ( pedestal pattern ) , white including white plastic water closet seat & back with flat bottom and cover mild steel chromium plated or aluminium anodised high device (excluding flushing cistern and flush pipe) but including fixing bolt and necessary connection with existing pipes complete all as specified and directed.
Supply & fixing PVC low level flushing cistern , white , 10 litres capacity with float valve and brackets complete including fixing low level flush pipe after dismantling of old unserviceable existing flushing cistern complete all as specified and directed.
Supply & Fixing 15mm Bore bib tap cast copper alloy chromium plated fancy type with crunch or butterfly handle screw down screwed for iron pipe or for brass funnel and fixed, in repair complete all as specified and as directed.
Supply & Fixing 15 mm bore stop valves, fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair, complete all as specified and as directed.
S&F Hand shower (health faucet) with 8mm dia, 1.2m long flexible tube & wall hook, complete with all accessories set as specified and as directed by Engr-in-Charge. Make : Jaquar Cat Part No. ALD-573 or equivalent in Marc/Kohler/ Parryware/Gorhe/Crabtree
S&F Soap dish, complete with all accessories set as specified and as directed by Engr-in-Charge. Make : Jaquar Cat Part No. AQN-7733 or equivalent in Marc/Kohler/ Parryware/Gorhe/Crabtree
Taking down of existing roof treatment from roof and Terrace, roughening surface of old concrete roof by picking, sweeping, cleaning and washing down with water to remove dust, etc and applying roof treatment with the following specifications:- (a) Applying cement slurry over concrete surfaces @3kg/sqm. (b) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (levelling course). (c) Applying evenly one coat of cold bituminous primer conforming to [email protected] litre per square meter on the cleaned plastered surfaces. (d) Applying a layer of APP based polymeric membrane, 3mm thick (minimum) weighing 3.50 Kg per square meter reinforced) with polyester non woven fabric weighing not less than 160 gms per square meter by torch application. The overlap shall not to be less than 100mm on transverse direction and 75mm on longitudinal direction and sealing overlaps. (e) Applying evenly one coat of aluminium paint @ 0.10 litre per square meter over the APP based polymeric membrane.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for frames of doors/windows/ventilators and partitions with extruded built up standard sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, including making provision for fixing of fittings wherever required including the cost of other required fittings etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, C.P.brass/stainless steel screws, all complete as per the directions of Engineer-in-charge. (Notes:- 1. The weight shall be of all aluminium components and fittings except the gaskets. 2. Glazing, wire mesh and panelling to be paid for separately and all other fittings shall be deemed to be included in the rate quoted.)
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for windows(sliding/fixed type) and ventilator shutters with extruded built up standard sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, including providing and fixing hinges/pivots/sliding track and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required and standard aluminium fittings like handles, bolts, stays, closing mechanisms and other required fittings etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing /panelling, C.P.brass / stainless steel screws, all complete as per the directions of Engineer-in-charge. Note : 1. The weight shall be of all aluminium components and fittings except the gaskets. 2. Glazing, wire mesh and panelling to be paid for separately and all other fittings shall be deemed to be included in the rate quoted.)
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples ,complete all as specified and directed.
M&L for aluminium anodized grill as per approved design and pattern weight not more that 4 Kg/sqm and fixed with frame complete all as per manufacturer's instructions and as specified and directed
Taking down carefully old unserviceable copper/aluminium point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. to be measured separately) and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as directed by the Engr-in-Charge.
Taking down carefully MCB/MCCB DBs SP/TP by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.
M&L point wiring with 1.5 Sqmm (nominal area) PVC insulated1100 volts grade, multistranded, copper conductor, single core, unsheathed cables (FRLS quality) drawn through and including PVC conduits of suitable size but not less than 20 mm dia (medium grade) with all fittings and accessories concealed in walls/ceiling etc including cutting chases for conduits and sinking for boxes and making good to disturbed surfaces including sunk mild steel terminal box with 3mm thick plastic laminated sheet top cover for mounting switches, sockets, regulators etc including PVC insulated and unsheathed, single core, multi-stranded, copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one light point / fan point/ one call bell point controlled by one 5 Amps one way switch complete as specified and directed. Note : Rate for Cutting, chasing and making good the existing surface for complete concealed wiring is deemed to be included in quoted rate all as specified & directed by Engr-in-Charge. .
All as per item No 89 above but one 3 pin socket outlet 5 Amps, on the same board with other switches.
All as per item No 89 above but one 3 pin socket outlet 5 Amps, on independent board.
All as per item No 89 above but one light point controlled by two, two way switch.
All as per item No 89 here-in-before but point wiring for one 3/5 pin 15 Amps socket point on independent board with 2.5 Sqmm size PVC insulated, unsheathed, multi stranded, copper conductor cables and with 2.5 Sqmm PVC insulated unsheathed, single core, multistranded copper conductor cable as earth wire complete as specified and directed.
Supply and fixing switch piano,6 Amp, flush type, single pole, one way 230 volts, complete all as specified and directed.
Supply and fixing switch bell push piano,6 Amp, flush type, single pole, one way 230 volts, complete all as specified and directed.
S & F socket outlet 5 Amps,3/5 pin flush type complete all as specified and directed.
S & F switch socket combination 2 in 1, 5 Amps, 3/5 pin, flush type complete all as specified and directed.
S & F switch socket combination 2 in 1, 3/5 pin, 5 and 15/16 Amps, flush type complete all as specified and directed.
S & F ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
Supply and fixing switch piano,6 Amp, flush type, single pole, two way 230 volts, complete all as specified and directed.
S & F stepped type electronic fan regulator, flush type 240 volts complete all as specified and directed.
Supply and fixing call bell electric, 240 Volts, single pole type ding dong complete all as specified and directed
Supplying and fixing in repair sheet metal enclosures for MCB's distribution board, double door, TPN, 4 ways with 200 Amps rated bus bar at 415 Volts complete all as specified and directed.
Supply and fixing of MCB SPN DB 8 way double door,IP-43 protection, isolated neutral bar, insulated busbar assembly, mechanical impact strength of IK08 complete all as specified and directed by Engr-in-charge.
Supply & fixing of MCB TPN 63 Amps 'C' Series 10 KA 240 volts complete all as specified/directed.
Supply & fixing of MCB SPN 32 Amps 'C' Series 10 KA 240 volts complete all as specified/directed.
Supply & fixing of MCB SP 6-32 Amps 'C' Series 10 KA, 240 volts complete all as specified/directed.
Supply and fixing lamp holder angular PVC/Polycarbonate suitable for batten fittings complete all as specified/directed.
Supply and fixing LED tubelight fitting 1x18 watts including Tube rod, 230 Volts, bipin holders connector block etc. complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. Make : Cat Part No: Bajaj Batten 112181 Batten for LED TUBE LIGHT fitting BLRB- DB 118. Bajaj Tube rod No BLRB-18 Watt CWc XE (112753) or Havells Cat Part No: REGALBATTENT5UPTO1X18WDSBSWH for batten and TITANIANEO1213T8SSTL18WLED865SPC for tube light or its equivalent in Philips
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised wire of size 4 mm (upto 7.50m length)as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar, funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execution and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed.
Material & labour for Sub main wiring with two runs of single core 6 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 volts grade drawn through and including PVC casing copping of adequate size (minimum 20mm) of wall/ceiling with all necessary fittings and accessories and 1 run of FRLS PVC insulated and unsheathed insulated single core cable with multi stranded copper conductor of size 6 Sqmm as earth wire (green in colour) run throughput and connected to common earth dolly including taking out the old sub main wiring complete all as specified and directed. Note : (a) Two run of cable, one run earth wire and one run PVC casing copping will be measured as one length.
Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 volts grade drawn through and including PVC casing copping of adequate size (minimum 20mm) of wall/ceiling with all necessary fittings and accessories and 1 run of FRLS PVC insulated and unsheathed insulated single core cable with multi stranded copper conductor of size 4 Sqmm as earth wire (green in colour) run throughput and connected to common earth dolly including taking out the old sub main wiring complete all as specified and directed. Note : (a) Two run of cable, one run earth wire and one run PVC casing copping will be measured as one length.
Supply only LED bulb of 9 Watt (Warm white). Make- BAJAJ B22 or equivalent to Philips/ CG/Havells/ Surya
M&L for cutting of circular hole and finishing same with painting/distempering/whitewashing on any type of wall suitable size for fixing of exhaust fan of size 300mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including, making good to disturbed surfaces of wall and to match as per the existing colour complete all as directed and specified by engineer-in-charge.
Supply & fix exhaust fans AC single phase 230/ 240 V copper wound, heavy duty, metallic body of size 300 mm sweep with louver,1400 RPM all as specified and directed. Make : Havells/Crompton/Bajaj
Taking down defective street light of any type and any size after disconnecting all incoming and outgoing electric connection from pole keeping serviceable fittings separately for reuse at site and removing unserviceable fittings from the site complete all as directed.
Supply and fix LED street light 45 watt, 230 volts with IP-66 protection inclusive all incoming & outgoing electric connection and testing for entire satisfaction of Engr-in-Charge. Cat Part No ENDURACITYLINERNEXGENSL45WLED757SASYBOPC of make Havells, Surya Cat Part No SLE UL 45 W IP66 LXN, Bajaj Cat No BRTFG 45W LED WW or equivalent in Phillips.
Supply and fix bracket made out from light grade GI steel tube 25mm dia not more than 1.5 Metres length and bend at 120 degree to shape for fixing LED street light fitting complete inclusive of all necessary fixing arrangements such as clamps, nuts, bolts etc duly painted with two coats of synthetic enamelled paint over a coat of red oxide pipe on steel surfaces inclusive taking out old bracket all as specified & directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. and for foundation of poles, stays etc. not exceeding 10 sqm on plan and n exceeding 1.5 in depth and getting out complete all as specified.
M & L for sand cushioning to underground cable for protection with fine river sand over, under ground cable laid in trenches and gently punned as cushioning to cable complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick of soft/loose soil in trenches/pit complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick, (locally available best quality), laid dry and flat complete all as specified and directed.
Supply and laying in trenches or passing through pipe or fixed to pole cable XLPE insulated screened underground, PVC bedded, galvanised steel strip or wire armoured, heavy duty 1100 volt grade, 25 Sqmm, 4 core with aluminium stranded conductor all as specified and directed . Note: (i) Excavation & earth work will be measured and paid separately
M/S UB ENTERPRISE
M/s Jaiswal and Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .