Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.0 L+₹6.6 L (30.7%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
28 Sept 2021, 6:00 pmClosed
GE Bharatpur
GE Bharatpur, Kanjoli Line
Repair Replacement of internal electrification ceiling fan geyser sub main wiring DBs earthing and connected items in OTM Md Accn at Kanjoli Line in Mil Stn Bharatpur
2021_MES_471371_1
8078/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Bharatpur
As per tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹58,000
Yes
30 Oct 2021
28 Aug 2021
30 Sept 2021
28 Aug 2021
28 Sept 2021
16 Sept 2021
29 Aug 2021 - 2 Sept 2021
Amount
Disconnecting & taking down the ceiling fan of 1200mm/1400mm sweep, for carried out preventive maintenance and rehanging the same after cleaning the dust etc with air pressure, cotton cloth & brush, taking out ball bearing and bush, cleaning with kerosine oil, lubricating greasing, oiling, cleaning to winding including supply and replacement of nuts, bolts, rubber real, split pin, connector and flexible cable of size 3 core 0.5 Sqmm upto required length from ceiling rose to connector of ceiling fan including testing all as directed. Note : (i)Patty item such as nut, bolt, washer,rubber seal, split pin, connector copper cable pvc insulated 0.5 sqmm 3 core are deemed to included in quoted unit rate of item.(ii) Parts/components replaced other than mentioned above will be measured and paid separately under respective items as supply only. (iii) The services of ceiling fan carrying out door to door.(iv) After completion of work all fans shall be tested to the entire satisfaction complete all as specified and directed
Disconnecting & taking down the wall fan/exhaust fan of 380mm/450mm sweep, for carried out preventive maintenance and rehanging the same after cleaning the dust etc with air pressure, cotton cloth & brush, taking out ball bearing and bush, cleaning with kerosine oil, lubricating greasing, oiling, cleaning to winding including supply and replacement of nuts, bolts, rubber real, split pin, connector and flexible cable of size 3 core 0.5 Sqmm upto required length from exhaust fan to connector of exhaust fan including testing all as directed. Note : (i)Patty item such as nut, bolt, washer,rubber real, split pin, connector copper cable pvc insulated 0.5 sqmm 3 core are deemed to included in quoted unit rate of item.(ii) Parts/components replaced other than mentioned above will be measured and paid separately under respective items as supply only. (iii) The services of exhaust fan carrying out door to door.(iv) After completion of work all fans shall be tested to the entire satisfaction complete all as specified and directed.
M&L for one coat spray painting of ceiling fan of any sweep complete with blades, down rod etc with synthetic enamel paint of approved colour by spraying including filling cavaties with filler, preparation of surfaces cleaning all dust etc and writing of MES No of size not exc 5cm high using black enamelled paint complete all as specified and directed
M&L for one coat spray painting of exhaust fan of any sweep complete with blades, etc with synthetic enamel paint of approved colour by spraying including filling cavaties with filler, preparation of surfaces cleaning all dust etc and writing of MES No of size not exc 5cm high using black enamelled paint complete all as specified and directed
M&L for cutting and dismantling the existing winding of ceiling fan of 1200mm sweep and rewinding with super enamelled copper winding wire heavy duty ISI mark of suitable gauge including varnishing, lubricating, greasing, oiling and testing including taking down and rehanging at the same location in complete all as directed.
Description all as per ser item No 5 above but 1400mm sweep ceiling fans.
Supply only of following parts/components suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed :- (a) Capacitor 2.5/3.5 mfd, oil filled, 400V AC, 50 HZ, 850C ISI marked Make : Asian/Unistar/Usha.
(b) Ball bearing (6201) Make : SKF, NBC, TATA.
(c) Ball bearing (6202) Make : SKF, NBC, TATA.
(d) Ball bearing (6203) Make : SKF, NBC, TATA.
(e) Hanging clip complete with rubber real existing as standard size available in market.
(f) Fan hook complete as standard size available in market for fixed with GI Pipe and existing Channel. Note:- Fixing of item No 7 to 7.05 shall be measured and paid under item No 01 only.
Supply and replacement of ceiling fan blade suitable for ceiling fan 1200mm sweep complete all as specified and directed.
Supply and replacement of down rod for ceiling fan 50cm long 15mm internal dia heavy duty duly painted including hanging clamp, rubber ring, nut and bolts complete suitable for ceiling fan of 1200/1400mm sweep.including necessary hole complete all as specified and directed.
Supply and replacement of canopy suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed.
M&L for cutting and dismantling the existing winding of exhaust fan 380mm sweep with super enamelled copper winding wire of suitable gauge including varnishing, lubricating, greasing oiling testing complete all as directed.
Description all as per ser item No 11 above but for exhaust fan 450mm sweep.
Supply of following parts/components suitable for exhaust fan 380/450mm sweep complete all as specified and directed.:- (a) Capacitor 4 mfd, oil filled, 400V AC, 50 HZ, 850C ISI marked. Make : Asian/ Unistar/ Usha/ LARSEN & TUBRO.
(b) Fan blade set for exhaust fan of 380mm sweep
(c) Fan blade set for exhaust fan of 450mm sweep Note:- Fixing of item No 13 to 13.02 shall be measured and paid under item No 02 only.
Taking down the existing unserviceable water storage type geyser of capacity 25/35 ltr of any make by disconnecting from water connection and reinstallation at the same location after carrying out necessary repair/replacement of unserviceable parts including one coat of spray painting with synthetic enamel paint of approved colour and marking of MES No. with black paint and testing complete all as specified and directed. Note:- Parts/components replaced other than mentioned above will be measured and paid separately under respective items as supply only.
Description all as per item No 14 above but 50 ltr capacity.
S&F in replacement Heating element 1500W with rubber ring clamping screws etc in geyser water storage type of capacity 25 ltr/35 ltr complete all as specified and directed..Make: as per existing.
S&F in replacement Heating element 2000W with rubber ring clamping screws etc in geyser water storage type of capacity 50 ltr complete all as specified and directed..Make: as per existing.
Supply only following parts required for repair of the geyser water storage type 25/35 ltr capacity complete all as specified and directed. (a) Thermostat switch adjustable type.Make: as per existing.
(b) Reset type thermal cut out.Make: as per existing.
(c) Fusible plug fuse.
(d) Non return valve vertical type spring loaded, ISI marked.Make: as per existing.
(e) Water storage tank made of 22 SWG copper sheet complete with flange for aperture plate and vent pipe connection for geyser.
(f) Water storage tank made out of special laminated texture finished body with covering of non corrosive protection on both sides of sheet statically powder coated body made of heavy gauge CRCA sheet.
(g) Iron neck ring.
(h) Brass inlet/outlet assembly complete without element and thermostat.
(j) Aperture plate made of brass.
(k) Element holding clip made of mild steel.
(l) Bolts with washer 25mm long for aperture plate.
(m) Rubber gasket, plate type for aperture plate.
(n) Rubber gasket, ring type for aperture plate.
(o) Indicator bulb square type complete with necessary connection wire of red & green colour complete as per sample kept in GE's office.
(p) Pressure release valve of size 15mm, ISI marked.
(q) Anti vaccum valve with GI tee of 15mm bore, ISI marked. Note:- Fixing of item No 18 to 18.15 shall be measured and paid under item No 14 only.
Supply only following parts required for repair of the geyser water storage type 50 ltr capacity complete all as specified and directed. (a) Thermostat switch adjustable type.Make: as per existing.
(b) Reset type thermal cut out.Make: as per existing.
(c) Fusible plug fuse.
(d) Non return valve vertical type spring loaded, ISI marked.Make: as per existing.
(e) Water storage tank made of 22 SWG copper sheet complete with flange for aperture plate and vent pipe connection for geyser.
(f) Water storage tank made out of special laminated texture finished body with covering of non corrosive protection on both sides of sheet with 100% pure Salem stainless steel sheet/electro statically powder coated body made of heavy gauge CRCA sheet
(g) Iron neck ring.
(h) Brass inlet/outlet assembly complete without element and thermostat.
(j) Aperture plate made of brass.
(k) Element holding clip made of mild steel.
(l) Bolts with washer 25mm long for aperture plate. Make : TVS.
(m) Rubber gasket, plate type for aperture plate.
(n) Rubber gasket, ring type for aperture plate.
(o) Indicator bulb square type complete with necessary connection wire of red & green colour complete as per sample kept in GE office.
(p) Pressure release valve of size 15mm, ISI marked.
(q) Anti vaccum valve with GI tee of 15mm bore, ISI marked.
(r) Hot water Connection Pipe Set 24-Inch long, standard 1/2-inch compression by standard 1/2-inch iron pipe straight thread,Flexible Note:- Fixing of item No 19 to 19.16 shall be measured and paid under item No 15 only.
M&L for removing unserviceable grouted "Anchor" type bolts and nuts from the wall and S&F new "Anchor" type bolts (04 Nos of 12mm dia) grouted properly in wall to hold 25/35/50 ltr capacity water storage type geyser with and including nuts and washers and marking good the disturbed surface in cement mortar 1:3 complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc and making good, cutting exc 10cm and not exc 20cm girth in brick or stone wall complete all as specified and directed.
S&F in repair galvanised, steel water tubing, 40 mm bore medium grade with all fittings complete to walls and ceilings for hanging of celing fan of following sizes complete all as specified and directed.
S&F in repair PVC cable 3 core copper conductor of size 2.5 Sqmm to water storage type geyser of capacity 25/35/50 ltr including taking out old cable complete all as specified and directed.
Taking down U/S plug top and S&F new 3 pin plug top 16 amps, 230 volts, ISI marked complete all as specified and directed..
S&F in repair sheet metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of DP 20 Amps, 240 volts complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, bell,same board, independent or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall, floor & ceiling etc complete all as specified and directed.
Dismantling of old U/S rusted main switch/DB of any size capacity and make complete all as specified and directed.
M&L point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe 20 mm bore (minimum) with all accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards/ existing sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed for the following :- (a) One light point controlled by one way switch.
(b) One fan point controlled by one way switch.
(c) One bell/buzzer point controlled by one push button.
(d) One 3 pin 6 Amp socket point outlet on the same board with other switches
(e) One 3 pin 6 Amp socket point outlet on the independent board
All as per item No 28 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 Amps multi purpose flush type 230 volt complete all as specified and directed. .
S&F switch socket combinatin 2 in 1, 16 Amp flush type multi purpose 230 volt complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amps 230 volt grade complete all as specified and directed.
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board complete all as specified and directed. make : Anchor code No 3290 penta or equivelent in Legrand.
S&F bell push flush type 5 Amps 230 volts grade complete all as specified and directed.
M&L bell multi musical type 230 volts grade complete all as specified and directed.
S&F step type electronic fan regulator EME type 450 watt make : Anchor code No 50440 penta or equivelent in Legrand complete all as specified and directed.
S&F submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit/sleeves 20 mm dia with all PVC accessories concealed in wall, floor/ceiling etc including taking down old unserviceable submain wiring complete all as specified and directed. Note:- Two runs of 4 sqmm cable and run of 4 sqmm earth cable and PVC conduct shall be measured as one unit.
S&F submain wiring complete with 10 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 10 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit/sleeves 25 mm dia with all PVC accessories concealed in wall, floor/ceiling etc including taking down old unserviceable submain wiring complete all as specified and directed. Note:- Two runs of 10 sqmm cable and run of 10 sqmm earth cable and PVC conduct shall be measured as one unit.
Supply and fixing of distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt/415V of the complete all as specified and directed following capacity: (a) 4 way TPN with 200 amps rated busbar 415 volts (double door type).
(b) 8 way SPN with 200 amps rated busbar 240 volts (double door type).
(c ) 4 Way SPN with 200Amp rated busbar 240V (Double door type)
Supply & fix 4 way VTPN Distribution Board (with provision for MCCB as incomer & WiNtrip MCB as outgoing) complete all as specified and directed.
S&F MCCB's,MCB's with GI hardwear of following capacity :- (a) MCCB 415 volts 100 Amps 04 pole 30 KA Make L&T Model:CM90679OOLO or equivalent make as mentioned in Appx B
(b) MCB SP 240 volts 10-32 Amps
(c) MCB SPN 40 Amps, 240 volt
(d) MCB TPN 63Amps C curve 415 V, 10 KA Make Havells Cat No:DHMGCTNF063 or equivalent make a specified in Appx 'B'.
S&F in repair Linear LED T8 tubular lamp of 20 watt with extruded aluminium body, PC diffuser and inbuilt driver with Batten suitable for LED T8 lamps , complete with all accessories internally pre-wired and including connecting to ceiling rose with three core flexible copper conductor cable of size 1Sqmm complete all as specified and directedCat Part No: LTT8-20+DMLN1LT8-16, Make Crompton or equivalent make a specified in Appx 'B'.
M&L batten holder insulated with back plate including suitable size of PVC round block complete all as specified and directed.
Supply and fix in repair white powder coated CRCA housing with LEDs 24 W, 230 V, 50 Hz recess mounting LED 2 feet x 2 feet luminaries, seemless front frame with flat white hight transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and directed Make :- Crompton Cat No LCTLRNE-24-FO-CDL or equivalent make a specified in Appx 'B'.
S&F in repair LED mirror light fitting 1 x 14 W 230 volts attractive wall / ceiling mounted type with decorative grey end caps, polycarbonate body and ribbed opal diffuser.matallic channel and white refelector suitabale for mirrior fitting,complete with all accessoris prewired and including connecting up with twin core twisted flexible copper conductor cable 0.5 sqmm size completeall as specified and directed..
Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 15 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm complete all as required specified & directed
unique traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .