Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5.4 L
EMD Value
₹10,000
Closing Date
12 Apr 2021, 1:00 pmClosed
SE HQ ATP ANPARA
OFFICE OF SE HQ ATP ANPARA
Overhauling and Breakdown Maintenance of Fire Fighting system and equipments of 3x210 M.W.,ATPS Anpara
2021_RVUNL_571266_1
06/HQ/FFSD1/ATP/2021-22
Open Tender
Miscellaneous Works
Fixed-rate
365 days
ANPARA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
DY CAO CFA and BO ATPS
₹10,000
23 Jun 2021
17 Mar 2021
12 Apr 2021
17 Mar 2021
12 Apr 2021
17 Mar 2021
Complete Overhauling of Fire Water Pumps
Complete Overhauling of Jokey Pumps
Complete Overhauling of Sump Pumps
Complete Overhauling of Air CompressorType-FC-40,KG Khosla
Complete Overhauling of Air CompressorType-30 Ingersol Rand
Foam Water Mixture Tank of Auto Fixed Foam system
Gate Valve of Sizes500 Nb
Gate Valve of Sizes300 Nb
Gate Valve of Sizes250 Nb
Gate Valve of Sizes200 Nb
Gate Valve of Sizes150 Nb/100 Nb/80 Nb
NRV of size 500 NB
NRV of size 300 Nb
NRV of size 150 Nb
Cleaning of sump pit
Complete overhauling of Fire water pump motor
Complete overhauling of Jokey pump motor
Complete overhauling of Air compressor motor 11 kw,0.4 kv,3 phase
Complete overhauling of Air compressor motor 3.7 kw,0.4 kv,3 phase
Sump pump motor
Replacement of damaged bearing including all related work alongwith its alignment 400 M3 Pump and motor
Replacement of damaged bearing including all related work alongwith its alignment 27 M3 Pump and motor
Replacement of damaged bearing including all related work alongwith its alignment 15 M3 Pump and motor
Bringing stator from store and replacement of damaged stator at the site
Replacement of damaged valve in fire fighting system by bringing valve from site store 450 and 400 mm gate valve and NRV
Replacement of damaged valve in fire fighting system by bringing valve from site store 80,100,150,200,250 and 300 mm gate valve and NRV
Replacement of damaged valve in fire fighting system by bringing valve from site store 65,80,100 and 150 mm Deluge valve and alarm valve.
Excavation of soil for attending leakage in pipe line of fire fighting system for Soft Soil
Excavation of soil for attending leakage in pipe line of fire fighting system for Hard Soil
Excavation of soil for attending leakage in pipe line of fire fighting system for Cemented concreate
Refilling of soil after attending leakage
Replacement of 450 mmNB size of pipe by cutting and welding
Replacement of 400 mmNB size of pipe by cutting and welding
Replacement of 300 mmNB size of pipe by cutting and welding
Replacement of 250/200 mmNB size of pipe by cutting and welding
Replacement of 150 mmNB size of pipe by cutting and welding 150 mmNB
Replacement of 150/200 mmNB size of pipe by cutting and welding at a height
Replacement of 80/100 mmNBsize of pipe by cutting and welding at a height at a height
Replacement of SPRINKLER at height of 37 Mtr coal Bunker
S ENTERPRISES
M/S AJAY ENGINEERING WORKS
Bidder Name
M/S SCINTECS PROCESS CONTROL
S ENTERPRISES
M/S AJAY ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .