Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.8 LAccepted-AOC WZ 619 PALAM VILLAGE NEW DELHI 45 | 1 | Accepted-AOC PG deposited by the agency. | |
| 2 | 2₹49.2 L+₹5.2 L (11.9%)Rejected-Finance 3 C 38 JAWAHAR NAGAR SRI GANGANAGAR RAJASTHAN | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 2 | Rejected-Finance Not L1 bidder | |
| 3 | 3₹47.7 L+₹3.7 L (8.40%)Rejected-Finance | 3 | Rejected-Finance Not L1 bidder | |
| 4 | 4₹49.3 L+₹5.3 L (12.1%)Rejected-Finance 2367 E BAWANA ROAD NARELA DELHI 40 | 4 | Rejected-Finance Not L1 bidder | |
| 5 | 5₹49.4 L+₹5.4 L (12.2%)Rejected-Finance NA | 5 | Rejected-Finance Not L1 bidder |
Tender Value
₹47.1 L
EMD Value
₹94,200
Closing Date
16 Aug 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(EMS)/SZ
O/o EE(EMS)/SZ
Vasant Vihar FCTS-to provide civil structure for fixed compactor transfer station (FCTS) at Dhalao No. 63, opposite MTNL office, F-Block Vasant Vihar, Ward No. 153, South Zone
2023_MCD_164014_1
EE (EMS)/SZ/TC/2023-24/02
Open Tender
Civil Works
Percentage
90 days
Vasant Vihar
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹94,200
11 Jan 2024
10 Aug 2023
16 Aug 2023
10 Aug 2023
16 Aug 2023
10 Aug 2023
Amount
Laying and Jointing PVC Pipe. Heading
Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required2x1.5 sq.mm+1x1.5 sq.mm earth wire
Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 Amp, 36 KA, FPMCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
Supply of 18"(450 mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter blade etc as required
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm
SITC of 30W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =30 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class-IP-66
SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class-IP-66
SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
Bidder Name
Amount
M/S RAM CONSTRUCTION CO(GSTN-07BBJPT7916D1ZD)
Gopal Goyal(GSTN-NA)
M/s Rakesh Kumar Goel(GSTN-NA)
NAVANKUR ENTERPRISES(GSTN-NA)
M/s Tara Builders(GSTN-NA)
AMIT CONSTRUCTION CO(GSTN-NA)
Pankaj Builders(GSTN-NA)
SANJEEV ASSOCIATES(GSTN-NA)
Pashupati Builders(GSTN-NA)
M/S S.B.Builders(GSTN-NA)
M/s Rakesh Kumar Goel
M/s Tara Builders
SANJEEV ASSOCIATES
NAVANKUR ENTERPRISES
Pashupati Builders
Pankaj Builders
M/S S.B.Builders
M/S RAM CONSTRUCTION CO
Gopal Goyal
M/s Rakesh Kumar Goel
M/s Tara Builders
NAVANKUR ENTERPRISES
Pashupati Builders
SANJEEV ASSOCIATES
AMIT CONSTRUCTION CO
M/S S.B.Builders
Gopal Goyal
Pankaj Builders
stage.html
html • 0.06 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .