| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.7 CrAccepted-AOC S NO 23 2 GROUND ANAND VIHAR COLONY SINHAGAD ROAD HINGAHE KHURD PUNE CITY PUNE MAHARASHTRA 411051 INDIA | PUNE | MAHARASHTRA | 411051 | ₹77.7 Cr Quoted ₹88.0 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹88.6 CrRejected-Finance | ₹88.6 Cr | L2 | Rejected-Finance Not L1 Hence Reject Tender |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical OFFICE NO 515 PLOT NO 194 NMS ICON SECTOR 19 ULWE NAVI MUMBAI MAHARASHTRA 410206 | NAVI MUMBAI | THANE | MAHARASHTRA | 410206 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹75.3 Cr
EMD Value
₹37.7 L
Closing Date
29 Aug 2022, 6:55 pmClosed
Executive Engineer, Public Works Division, Pune 1.
Executive Engineer, Public Works Division, Pune 1.
40-1 - Construction of New Administrative Building for Education Department at City Survey No. 832, Final Plot Number 173, Bhamburda, Shivajinagar, Pune. (Including Electrical Work).
2022_PWDRP_823395_1
E-Tender Notice No. 40 for 2022-2023
Open Tender
Civil Works - Buildings
Shivajinagar Pune
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,360
₹37.7 L
Chief Engineer, Public Work Region, Pune.
4 Jun 2023
1 Aug 2022
1 Sept 2022
1 Aug 2022
29 Aug 2022
1 Aug 2022
17 Aug 2022
Amount
Removing grass,grazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc.complete.
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 metre) By Mechanical Mean
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/ murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means
Excavation for foundation in Softrock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/ murum, ramming, watering including shoring and strutting etc.complete. (Lift from1.5 metre to 3.0 metre) By Mechanical Means
Excavation for foundation in Softrock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/ murum, ramming, watering including shoring and strutting etc.complete. (Lift from 3.0 metre to 4.5 metre) By Mechanical Means
Excavation for foundation in Softrock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/ murum, ramming, watering including shoring and strutting etc.complete. (Lift from 4.5 metre to 6.0 metre) By Mechanical Means
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc.complete. (Lift from 4.5 metre to 6.0 metre. By Mechanical Means
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc.complete. (Lift from 6.0 metre to 8.5 metre). By Mechanical Means
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc.complete. (Lift from 8.5 metre to 10.0 metre). By Mechanical Means
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)
Providing and laying perforated poly vinyl chloride 160 millimetre diameter pipe in proper line,leveland slope including necessary material fitting etc. complete.
Providing preconstructional antitermite treatment as per I.S.6313(Part-II)treatment by treating the back fillin immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. BASEMENT 2
BASEMENT 1
Providing preconstructional antitermite treatment as per I.S.6313 (Part-II) by treating the top surface of plinth filling at the rate of 5litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-10 of trap metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick cement mortar 1:3 with conceal, setcrete ( RMW ), Algaeproof or other alike water proofing liquids, raking of joints upto 35 millimetre depth,filling the joints with 6 millimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding cement concrete 1:3:6 base concrete).
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 millimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 millimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete). Basement 01
Basement 02
Smart Care Preapply HDPE 80 for Raft and Uncofined Retaining Walls 1- Supplying and Installing of Asian Paints Smarteare 1.20 millimetre thick pro applied HDPE fully bonded membrane or equivalent make having puncture resistance of HOON as per ASIMI 154), tensile strength of 21 Mpa, and hydrostatic head resistance not less than zom water head as per ASTM D 545 elongation of 500% as per ASTM D412, peel adhesion to concrete of 1200 N/m as per ASTM D 901, Lap peel adhesion 450N/m as per ASTM D1876. The size of the membrane should be 1.2m x 20m. The pre-applied, fully bonded HDPE sheet membrane shall be loosely laid on PCC and gets bonded to the underneath of the poured concrete of base/ raft slab and confined retaining wall. The fully bonded HDPE sheet membrane shall consist of a high performance PE film, self adhesive polymer layer and unique particulate layer with pressure sensitive adhesive, which bonds fully to the poured concrete of base slab/confined retaining wall. The membrane shall have minimum of 75 millimetre side laps and end laps which shall be sealed with double sided adhesive tape, plc complete as per manufactures specification and Instructions. This shall include cleaning and removal of all the dust, dirt, oll, grease, coment laltance, loose particle and prepare the P.C.C. Substrate for laying of waterproofing system, as directed by Engineer Incharge and covering 10 years Guarantee against leakages on Court fee stamp paper of Rs. 500/- etc. complete. Basement 02
Smart Care Ultron (Hybrid Polyurea) for Retaining Walls -Providing and laying liquid based Asian Paints Smartcare Ultron or equivalent make (Polyurea-Polyurethane seamless/jointless treatment) for waterproofing on the Un-confined vertical surface by cleaning the external surface, removal of loose concrete and filling cracks with polymer modified mortar and treatment of tie rod holes, bracing angle etc with plugging mortar, as per manufacturers' reco millimetre endation, thereafter, providing and applying one coat of two component solvent free epoxy primer @ 0.15-0.20 kilogramme /m2, followed by providing and applying 2 component high performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, liquid membrane with an elongation of 600% and tensile strength of 12.6 N/ millimetre 2 as per ASTM D 2370, crack bridging ability of 3 millimetre as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying in two coats at 1.5 kilogramme per Sqm etc, complete as per Manufacturer specifications. HDPE Termination at Raft with Aluminium strip of width min. 75 millimetre , with the turnkey execution to be done by the manufacturer through its in house subsidiary execution company and as directed by Engineer incharge with covering 10 years Guarantee against leakages on Court fee stamp paper of Rs. 500/- etc. complete.including protective foam of 20 millimetre thick for outer surface of retaining wall. Basement 01
Basement 02
Car Deck Coating 2 millimetre ( Parking ) Any Colour of RAL Shade: Providing and applying Car Deck Coating for Parking surface including Surface prepration by cleaning, Grinding, Cracks and Pot filling to the entire floor by Asian Paints Apcoflor LSC 3XL or eqvivalant Supplying and applying Asian Paints Smartcare Car deck primer Coating to the entire floor by first applying AP Apcoflor HFP 120 primer coat at a rate of 0.2 kilogramme per Sqmt, then applying AP apcoflor Car deck başe coat @ 0.8 kilogramme per sqm. I millimetre ediately Providing and seeding the quartz silica sand @ 3 kilogramme per sqm on the wet base coat. Applying AP Smartcare Apcoflor Car deck top Coat @ 0.8 kilogramme per sqm in onecoats .Providing and lining - stencilling on the dried surface of top cat using Apcoflor TC 650 Top coat-2 components of required colour etc complete as per manufacturer's specification and as directer by Engineer incharge.. Basement 01
Basement 02
Providing and laying in situ /Ready Mix cement concrete Mix-20 of trap metal for Reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 of trap metal for Reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT 2
Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 of trap metal for Reinforced cement concrete PARDI as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabledConcrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT 2
BASEMENT 1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing dry rubble stone soling 15 centimetre . to 20 centimetre . thick including hand packing and compacting complete. (ONLY LABOUR RATE TAKEN FOR ABOVE ITEM) GROUND FLOOR
Filling in plinth and floors with approved excavated materials in 15 centimetre . to 20 centimetre . layers etc.complete. BASEMENT 2
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/ bolted/ welded connections without connecting plates, braces etc.and including one coat of anticorrosive paint and overit two coats of oil painting of approved quality and shade etc.complete BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-40 of trap metal for Reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-25 of trap for Reinforced cement concrete columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-25 of trap metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabledConcrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT1
BASEMENT2
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-40 of trap metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-25 of trap metal for Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 of trap metal for Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT2
Providing and laying Cast in situ/Ready Mix cement concrete Mix-40 of trap metal for Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mixcement concrete Mix-25 of trap metal for Reinforced cement concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-20 of trap metal for Reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-40 of trap metal for Reinforced cement concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in position Thermo mechanically treated (TMT) - FE - 500 bar reinforcement of various diameters forReinforced cement concrete pilecaps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawing sand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing during laying in Reinforced cement concrete Slab rectangular 2 millimetre thick mild steel sheet fan hook box of size 180x100 millimetre with required depth with holes or not chesas required, bottom and top sides of 1.6 millimetre mild steel sheet fixed with 3.5 millimetre diameter round headed screws together with 12 millimetre diameter mild steel bar bent to shape with hooked ends for fan hook and painting to exposed surface BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part3)-1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185(Part3)-1984 in extra fine jointing mortar offixoblock of UltraTech or equivalent in Halfbrick thick wall including striking joints, raking out joint sand scaffolding etc. Complete. (The test shall becarried out conforming to IS:6441 (Part I) - 1972) LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing internal cement plaster 20 millimetre . thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete with natural sand. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete. BASEMENT2
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete with natural sand. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying plaster with plaster of paris in 6 millimetre thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying priming coat over concrete/ Masonry/ Asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, greese, dirt and other foreign matter and sand papering as required etc. complete. humidity of upto 90%. Magnesite protects the wood cells against ageing and fungal attack. To achive upto NRC=1.00 it should be a clear gap of 200 millimetre from wall slab along with the backing of Mineral wool of 50 millimetre thick with 64 kilogramme /m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 and EN13964 with flying colors and A sustainable material (PEFC and FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Envirenmental Product declaration). Manufacturing tolerance for nominal size: Length, Width and Thickness ± 1 millimetre , and In a Standard Climate of 23° C and 50% rel. humidity. FIXING and SUBSTRUCTURE: Impact Resitant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel and Centre Distance Support of 300 millimetre and Centre distance of Cross Profile would be at 600 millimetre and Main Profile at 900 millimetre CD Profile is made out of GI( Sections Profile 60/27/0.6 millimetre -0.6 millimetre Thick x 60 millimetre Width x 0.27 millimetre height). The Main Profile is in the legth of 3000 millimetre and to form a section of 600 millimetre x 1200 millimetre . Heradesign Superfine panels to be fixed on the wall with a minimum of 200 millimetre void or gap with Galvanized screws of length 50 millimetre and Dia 4.5 millimetre with a backing of Mineral Wool of density 64 kilogramme /m3 density (50 millimetre thick).Colour Of Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scraping if necessary including scaffolding etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian / Berger / Nerolac / Dulex Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller. (With prior approval of S.E.) BASEMENT 2
BASEMENT 1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1kilogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete with natural sand. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC?s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kilogramme /15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing water proof bedding for flooring of Bath and Water closet 25 millimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre . thick layers of same mortar added with jute fiber at 1kilogramme per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre x 300 millimetre . making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. FIRST FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance and thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. EIGHTH FLOOR
Providing waterproofing in water closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1 kilogramme per bag of cement laying brick bat coba of required thickness in centimetre 1:5 with waterproofing compound 1 kilogramme /bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in centimetre mortor 1:3 with waterproofing compound 1 kilogramme per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying machine cut machine Polished Kota stone flooring 25 millimetre to 30 millimetre thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 millimetre to 30 millimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying matt finish ceramic tiles of having size 30 centimetre x 30 centimetre confirming to I.S.15622/2006 (group D II-A) and 7 to 8 millimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
Providing and Fixing in position, Carpet more than 800+ gsm, made with100% stain proof fibres of approved make along with 5 millimetre underlay as per Architectural and Acoustical Design and Instructions and Complete in all aspects including all materials labour,finishing etc complete. LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
Providing and laying ceramic tiles of having size 30 centimetre .x 30 centimetre .and confirming to corresponding I.S. for dado and skirting in required position with ready made adhesive mortar of approved quality on plaste rof 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying vitrified matt finish tiles having size 300 millimetre X 600 millimetre of 8 to 10 millimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Glazed Vitrified tiles Matt/Antiskid finish of size 800 x 1200 millimetre in floors of 8 to 10 millimetre thickness with water absorption less than 0.08% and confirming to IS 15622 of approved brand and manufacturer in all colours and shades laid on 20 millimetre thick cement mortar 1:4 ( 1 cement 4 course sand ) jointing with grey cement slurry @ 3.3 kilogramme /sqmt including grouting the joints with white cement and matching pigments etc. The tiles must be cut with zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel , piller,wedge,clips of required thickness,leveling system and rubber mallet for placing the tiles gently and easily. EIGHTH FLOOR
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and confirming to IS15622-2006 (Group-BIIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
WOODEN FLOORING: Providing and laying 10 millimetre thick solid ENGINEERING WOODEN FLOORING including SKIRTING of same material and design of Armstrong, Egger or equivalent (matt finish) consisting of panels of size 1200 millimetre x 200 millimetre or as per manufacturer specification. The panels having a click system tongue and groove joint to secure a long lasting joint with the edges duly impregnated with paraffin. The Floating wooden flooring shall be laid over a 0.20 millimetre thick polythene film to form a vapor barrier and 2 millimetre to 3 millimetre thick approved FOAM. The panels used shall be of high solidity, high impact strength, high temperature resistance without change in shape). Each panel shall have click system (tongue and groove profile) and to be laid in approved pattern with suitable glue if required as per manufacturers specifications including alround suitable egde profile alround/wherever required for firm end locking. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying in situ cement concrete Mix-20 with tremix treatment for 100 millimetre thickness for flooring with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen etc. complete. BASEMENT2
BASEMENT1
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and preparing kitchen otta up to 75 centimetre width, made up from 30 millimetre . thick and 75 centimetre . high vertical support for kadppa at 1 metre center to center of 25 millimetre . thick both side polished kadappa middle shelf and bottom of 20 millimetre . thick one side polished kadappa with facia patti of 20 x 50 millimetre . kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre x 40 millimetre x 5 millimetre with oil painting, etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Polishing applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying french polish, scaffolding if required etc. complete. Note: The work to be excuted on prior approval of Superintending Engineer will be necessary. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shuttes indouble leaves 35 millimetre thick, decorative type of exterior grade, as per detailed drawings, conforming to I.S.:2202–1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame) (Sample to be got approved from Ex. Engineer before use) COMMERCIAL Hard Wood shutter. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing 44 millimetre thick both side laminated Door ( With Glass ) made up of 18 millimetre thk plywood frame covered with 12 millimetre thick plywood both side of the frame to get required thickness as per architectural design and drawing of CENTURY MAKE COMMERCIAL PLY BWR GRADE (ISI 303 ) or equivalent make with both side 1.0 millimetre thk laminate of ROYAL TOUCH or equivalent make confirming to (ISI 2046) with grove finish with 43 x 10 millimetre BTC lipping and 8 millimetre float glass strip as per drawing is fitted by BTC 20x10 millimetre moulding icluding all material brass screw brass hinges (125 x 12 millimetre ) ENOX make mortice lock, door stopper,antitermite treatment to plywood,two coats melamine polsih to moulding and lipping, lobour charges as directed by engineer in charge etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
Providing and fixing 30 millimetre thick poly vinyl chloride FLUSH L DOOR SHUTTER consisting of panel of hollow poly vinyl chloride profile of 20 millimetre thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19 millimetre x 19 millimetre inserted inside the hollow section of stiles rails top ?and bottom rails and two 19x 19 millimetre MS tubes inserted horizontally inside the hollow profile section using 4/5 millimetre sheet using screws hollow profile shall be lipped with 10 millimetre (5 millimetre x2) thick x 20 millimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5 millimetre thick termite proof waterproof plain /prelam poly vinyl chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening etc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
a) Door Frame: Supplying and Fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 kilogramme per cubic metre) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 millimetre spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10 millimetre x 4 millimetre affixed in the slit of the Frame for fire and smoke sealing, etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
b)Shutter : Supplying and Fixing of 55 millimetre thick asbestos free 'TUFWUD' brand - 3 criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8 millimetre Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 kilogramme /cum) frame work of 100x32 millimetre with 32 millimetre thick infill of ceramic fiber (density 128 kilogramme /cum), vermaculite mix faced with 3 millimetre Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10 millimetre x4 millimetre affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
c)VisionPanel: 2 HR rated E Class clear high stress fire rated glass is prefabricated strategically inside the shutter structure with10 millimetre in side the shutter on all sies with U-glazing.Anadditional insulated powder coated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing single shutter glass door of required size of 12 millimetre thick toughen glass frosting and edge polish as shown in the drawings or as directed , including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing double shutter glass door of required size of 12 millimetre thick toughen glass frosting and edge polish as shown in the drawings or as directed , including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing Aluminium colour anodized sliding and folding door 2 shutters having special patented frame and shutter profiles.Oter frame profles being fixed to the missionary with SS-202 screw shutters having 45 degree corner joints with special cleats for linear joints having 6 millimetre toughned glass are installed in the frame structure with mortise lock at opening, Top and bottom pivots for sliding,but hinges for folding operation and subsidiary multi point locking and pop handle for additional security,complete. LOWER GROUND FLOOR
GROUND FLOOR
SECOND FLOOR
Two Track Two Glass Shutter Window : Providing and fixing aluminium color anodized system sliding window of various sizes. Window will be made from Geeta / Lixil / Malwin , 25 to 27 millimetre slim series or equivalent System. Windows will be of specially extruded aluminium 2 Track - 2 Glass shutter window/ ventilator, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Three Track Two Glass + One Net Shutter Window :Providing and fixing aluminium system color anodized sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson, 25 to 27 millimetre slim series or equivalent System. Window will be of specially extruded aluminium 3Track - 2 Glass + 1 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Three Track Three Glass Shutter Window :Providing and fixing aluminium system color anodized sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson, 25 to 27 millimetre slim series or equivalent System. Windows will be of specially extruded aluminium 3Track - 3 Glass shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Three Track Four Glass + Two Net Shutter Window :Providing and fixing aluminium system color anodized sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson, 25 to 27 millimetre slim series or equivalent System. Windows will be of specially extruded aluminium 3Track - 4 Glass + 2 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Aluminium System Color Anodized Fixed Window : Providing and fixing aluminium system color anodized fixed window of various sizes. Casement will be made from Geeta / Malwin/Lexil/Brandson, 40 millimetre series or equivalent System. Windows will be of specially extruded aluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 wood screws. Fixed glass casement will be made from specially extruded aluminum section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogramme /sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
Providing and fixing 12 millimetre thick toughen glass and edge polish as shown in the drawings or as directed, including all necessary fittings like Upper glazing profile, bottom locking glazing profile, standard gasket for profile, locking Gasket 12 millimetre , door soft central 180 weather seal for glass edges as per drawings having glass fixing sections at all sides concealed in partitions etc. complete as directed by Engineer -IN-Charge. gaps between glass panels should be filled by clear silicon weather proofing sealant , EPDM gaskets, handles all necessary fasteners and accessories complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing frosting to the glass and other required surfcaes as shown in the drawings or as directed, including all necessary work etc. Frosting should be even and no uneven patterns will be accepted for the same. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600 millimetre Lay in tiles of pre coated galvanized steel in 0.5 millimetre thickness in Global white color tile to be laid on grid systems with 15 millimetre wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimetre and 600 millimetre Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600 millimetre Lay in tiles of pre coated galvanized steel in 0.5 millimetre thickness in Global white color tile to be laid on grid systems with 15 millimetre wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimetre and 600 millimetre Cross Tees.products approved as per GRIHA and BS 476 etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
METAL FALSE CEILING WITHOUT SUSPENSION SUPPORT FROM TRUE CEILING: Providing and fixing horizontal level suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions with Rectangular panels made of 0.7 millimetre thick Galvanised Steel (GI) of 120gsm, post coated to Global White colour, suitable for Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300 millimetre , length ranging from 1500 millimetre to 2660 millimetre . General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7 millimetre as per in IS:513 (1994). Dimensions: The panel Length varies between 1500 millimetre to 2660 millimetre , panel Width shall be 300 millimetre . The dimensional tolerances for length shall be ±1.0m up to 1000 millimetre L; ±1.5 millimetre between 1001 to 2000 millimetre L; ±2.0 millimetre between 2001 to 3000 millimetre L. The dimensional tolerances for width shall be ±0.5m up to 300 millimetre W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3 millimetre (W) x 8 millimetre (H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30 millimetre (H) and shall be bent appropriately bent as per the manufacturer‘s specifications for providing hook-on ends. The long side shall have inside horizontal bends of 5-15 millimetre for rigidity and vertical upturns of 40 millimetre (for length ranging from 1251-2660 millimetre ). Surface Finish: Plain: The panels shall be in plain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (∆e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µ thickness, having appropriate surface adhesion (or tackiness) corresponding to surface gloss level. Light reflectance: The panel shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400 millimetre . The difference between the two diagonal dimensions of the panel to be less than 1 millimetre . The sag to be measured at the center in accordance with TAIM standards. Access and Plenum space: The panels to be Fully Accessible, with system height of 98 millimetre ,
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15 millimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 20 millimetre , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 millimetre with 15 millimetre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 32 millimetre and a load carrying capacity of 7.7 kilogramme s/M2 and minimum pull out strength of 100 kilogramme s.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
ACOUSTICAL WOODWOOL WALL PANELLING: Providing and fixing of 100% Natural Material- Magnesite (Hygroscopic and biologically sound binding agent) bonded woodwool Heradesign planks of 600 millimetre *1200 millimetre *25 millimetre thickness made out of wood wool fibre of width 1 millimetre Fiber thickness mixed with Natural water and Magnesite (No-Cement) with open and smooth surface texture, Weight of panel to be 11.3 kilogramme /m2. A Completly harmless Envirenment and Human Friendly and also a disposable or recyclable Material and can last for more than 80 Years in building interiors As it has long lifespan and suitable for Indoor conditions with relative air humidity of upto 90%. Magnesite protects the wood cells against ageing and fungal attack. To achive upto NRC=1.00 it should be a clear gap of 200 millimetre from wall slab along with the backing of Mineral wool of 50 millimetre thick with 64 kilogramme /m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 and EN13964 with flying colors and A sustainable material (PEFC and FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Envirenmental Product declaration). Manufacturing tolerance for nominal size: Length, Width and Thickness ± 1 millimetre , and In a Standard Climate of 23° C and 50% rel. humidity. FIXING and SUBSTRUCTURE: Impact Resitant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel and Centre Distance Support of 300 millimetre and Centre distance of Cross Profile would be at 600 millimetre and Main Profile at 900 millimetre CD Profile is made out of GI( Sections Profile 60/27/0.6 millimetre -0.6 millimetre Thick x 60 millimetre Width x 0.27 millimetre height). The Main Profile is in the legth of 3000 millimetre and to form a section of 600 millimetre x 1200 millimetre . Heradesign Superfine panels to be fixed on the wall with a minimum of 200 millimetre void or gap with Galvanized screws of length 50 millimetre and Dia 4.5 millimetre with a backing of Mineral Wool of density 64 kilogramme /m3 density (50 millimetre thick).Colour Of Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
Providing and fixing in position Gypsum board false ceiling with 12.5 millimetre thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
ACOUSTICAL GLASS FIBRE FALSE CEILING CLOUDS and SHAPES : Providing and Fixing Acoustical Clouds/Shapes - Acoustical clouds which are 30 millimetre thick, flat glass fibre panels of Humidity Resistance RH 95%, with embedded frame made of aluminium extruded section of 38X10 millimetre of grade 6063-T6 as per dimension mentioned in below table for reinforcement and secured hanging. Embedded extrusion shall have grub slot with pre inserted nut for group hanging and connected using Aluminium die casted corner connector with ¼‖ – 20 threading for hanging using cable adjuster for independent clouds. The form of Acoustical Clouds/Shapes - shall be Square / Convex / Concave / Circle / Hexagon / Trapezoid / Parallelogram (Left and Right) / Rectangle (Small and Large) in standard Traffic White color with light reflectance 90% as per ASTM 1477-98 or in the color specified by the Architect / Engineer in charge (Shell / Tangerine / Cranberry / Moss / Kiwi / Reef / Lagoon). The Acoustical Clouds/Shapes shall be made of Glass fibre panel with density of 110-120 kilogramme s/m3 along with acoustical sound absorbing scrim on the face to achieve sound absorption as per below mentioned table in accordance to EN ISO 354 :2003 (average of 500-4000Hz) . The face and edges shall be finished with matching water based texture paint. Shape Nominal Size and Sound Absorption – Metric Sabin 1. Square 1170x1170 millimetre - 2.48 Metric Sabin 2. Convex 1170x1140 millimetre 2.28 Metric Sabin 3. Concave 1170x1140 millimetre 1.94 Metric Sabin 4. Circle 1170 diameter 2.12 Metric Sabin 5. Hexagon 1170x1010 millimetre 1.61 Metric Sabin 6. Trapezoid 1170x1170 millimetre 2.15 Metric Sabin 7. Left Parallelogram 1170x1170 millimetre 2.15 Metric Sabin 8. Right Parallelogram 1170x1170 millimetre 2.15 Metric Sabin.The panel shall be hung as per the following based on the installation. Individual Suspension - The panel shall be hung using deck hanging kit comprising of griper structure anchor and cap of diameter 20 millimetre , spring loaded bottom end cable adjuster of diameter 9 millimetre and 2.4m long aircraft cable of 1/16‖ diameter The number of deck hanger will be as per Table 1 above. The Acoustical Clouds/Shapes shall carry a 1 year warranty against manufacturing defect and supported by a manufacturer warranty certificate. The supply shall be backed by a Manufacturing Test Certificate. Suspension System Details Components 1) Griper structure anchor, 2) Gripper anchor cap 3) Cable adjuster 4) Aircraft Cable Cable adjuster Spring loaded bottom end cable adjuster of diameter 9 millimetre and 45 millimetre long Aircraft cable Material Galvanized Steel Aircraft cable dimension 1/16‖ Ø x 2.4m Tolerance ±1 millimetre INSTALLATION: Individual Suspension. The panels to be suspended individually using the Acoustical Clouds/Shapes Deck hanging kit as per the number specified in above Table 1. Hanger Wire Attachment to Structure: Attach the gripper structure anchor to the true ceiling using an appropriate fastener (1/4"-20 Threading) that will carry the full weight of the panels. Insert the end of the cable into the gripper anchor cap. Screw the gripper anchor cap completely into the gripper structure anchor. The panel to be suspended using the aircraft cables from the soffit by fixing the cap end of the cable to gripper structure anchors and the other end passing through the bottom end cable adjuster. The height and level of the panels can be adjusted using the bottom end cable adjusters. Suspend the Acoustical Clouds/Shapes by locating and screwing the bottom end of the cable adjuster into the threading of the connector. LOWER GROUND FLOOR
GROUND FLOOR
ACOUSTICAL WOODWOOL FALSE CEILING: Providing and fixing of 100% Natural Material- Magnesite (Hygroscopic and biologically sound binding agent) bonded woodwool Heradesign planks of 600 millimetre *1200 millimetre *25 millimetre thickness made out of wood wool fiber of width 1 millimetre Fiber thickness mixed with Natural water and Magnesite (No-Cement) with open and smooth surface texture, Weight of panel to be 11.3 kilogramme /m2. A Completely harmless Environment and Human Friendly and also a disposable or recyclable Material and can last for more than 80 Years in building interiors As it has long lifespan and suitable for Indoor conditions with relative air humidity of upto 90%. Magnesite protects the wood cells against ageing and fungal attack. To achieve upto NRC=1.00 it should be a clear gap of 200 millimetre from wall slab along with the backing of Mineral wool of 50 millimetre thick with 64 kilogramme /m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 and EN13964 with flying colors and A sustainable material (PEFC and FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Environmental Product declaration). Manufacturing tolerance for nominal size: Length, Width and Thickness ± 1 millimetre , and In a Standard Climate of 23° C and 50% rel. humidity. FIXING and SUBSTRUCTURE: Impact Resistant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel and Centre Distance Support of 300 millimetre and Centre distance of Cross Profile would be at 600 millimetre and Main Profile at 900 millimetre CD Profile is made out of GI( Sections Profile 60/27/0.6 millimetre -0.6 millimetre Thick x 60 millimetre Width x 0.27 millimetre height). The Main Profile is in the length of 3000 millimetre and to form a section of 600 millimetre x 1200 millimetre . The CD Profile is to be suspended from soffit with the help of nonius hanger at a center distance of 900 millimetre . UD Profile 28/27/0.6 millimetre to be fixed on wall at the perimeter of the wall. If the main CD profile needs to extended, it needs to be connected with CD profile connector 60/27. The CD profiles to be connected to each other at the intersection by CD cross connector. Heradesign Superfine panels to be fixed to the ceiling with a minimum of 200 millimetre void or gap with Galvanized screws of length 50 millimetre and Dia 4.5 millimetre with a backing of Mineral Wool of density 64 kilogramme /m3 density (50 millimetre thick). Colour pf Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted. SECOND FLOOR
METAL BAFFLE CEILING : Providing and fixing of horizontal level suspended ceiling comprising of Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600 millimetre in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black and White).. The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25±5 at 60˚ as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U-profile of 20 x 30 x 3700 millimetre (Thk-1.5 millimetre ) having slots in module of 25 millimetre to keep baffles at an on-center spacing in multiples of 25 millimetre . Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps..SUSPENSION: Shall be hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U – profile to comprise of alternate square and rectangular slots of 6.5x6.5 millimetre and 28x6.5 millimetre respectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve uniform spacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L) millimetre and is rolled form from1.5 millimetre thick mild steel with a powder coating thickness of 6080micron. U- Profile to be connected to each other using U –Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. The Baffle along with suspension system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate. INSTALLATION: Installation of U-Grid: The U profile to be suspended at every 1200 millimetre center to center using 6 millimetre threaded rod from the structural soffit using U-profile hanger. U-profile splice to be used to join more than one U profiles of length 3.7M. 1st U-Grid Channel must be no more than 400 millimetre from the perimeter. Installation of Baffles: Locate the slot for Baffle Hangers in U Profile section at 1200 millimetre centers. Hangers are inserted into the slot, then rotated 90° and fixed into position by tightening the grub screw. Baffle to be lifted into position and hangers engage over lip of U-Grid Channel. Each Hanger to be secured into position by inserting the Locking Clip. When doing continuous installation, Baffles blades are to be connected at ends with Baffle Joiner, which are inserted into the top and bottom slots of the Baffle closed profile for alignment only. The bottom Joiner to be located first and fastened on one side only. The top Joiner to be fitted then and secured with grub screws on one side. Then the two Baffle sections shall be joined and the top Joiner is screw fastened on the 2nd Baffle profile. End Caps to be located by pushing the End Cap tongues into open Baffle slots. Installation should be carried out as per Manufacturer reco millimetre ended procedure. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
CUSTOM PRINTED ACOUSTICAL FALSE CEILING :Providing and Fixing of Custom color Printed Mineral Fibre Acoustical Suspended Ceiling System with 19 millimetre thick Microlook 90 Edge Tiles with 15 millimetre face exposed grid. The tiles shall have smooth bright laminated visual with Humidity Resistance (RH) of 99%, NRC 0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 41db as per ASTM E1414, Light Reflectance ≥87% as per ASTM E-1477, Thermal Conductivity k = 0.045 - 0.048 W/mK, Colour Global White, Fire Performance of Class 0/1 as per BS 476 Part6/7 and Class A as per ASTM E 84 with 19 millimetre Square Tegular/Microlook 90˚ edge and 8 millimetre drop in module size of 600 x 600 millimetre . The scrim on the face of the tile shall be cleanable, soil and scratch resistant and having superior scrub-ability (Gardner Test). The tiles shall be classified as ISO 14644-1 cleanroom class 5. The tile shall have a rating of 8 or above for tests conducted for Resistance to growth of Mold in accordance to ASTM D3273. It shall be suitable for Green Building application, with Recycled content of 36%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on with 15 millimetre wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 38 millimetre (all sections). The deflection loading of the system shall be 12.5 kilogramme /m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15 kilogramme /m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between ―cross tee to cross tee‖ and ―cross tee to main beam‖. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100 kilogramme . The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. INSTALLATION: To comprise main runner spaced at 1200 millimetre securely fixed to the structural soffit using suspension system (specifications above) at 1200 millimetre maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450 millimetre from the adjacent wall along with the first and the last main beam shall be at less than 600 millimetre from the wall. Flush fitting 1200 millimetre long cross tees to be interlocked between main runners at 600 millimetre to form 1200 x 600 millimetre module. Cut cross tees longer than 600 millimetre require independent support. 600 x 600 millimetre module to be formed by fitting 600 millimetre long flush fitting cross tees centrally between the 1200 millimetre cross tees. Perimeter trim to be wall angles of size 3000x19x19 millimetre , secured to walls using screws at 450 millimetre centre to centre maximum. Installation shall be carried out as per Manufacturer reco millimetre ended procedure. SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 millimetre of 1.80 metre length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kilogramme s. (Optionally, adjustable hook clips made of 0.7 millimetre thick Grade 1 C55 galvanized spring steel of dimension 100 x 20 millimetre and 4 millimetre aquiline wire to be used for level adjustment during installation purpose in main runners).. SECOND FLOOR
Providing and fixing in position false ceiling made up of 19 millimetre Plywood Conforming to ISI-303 finished with 3/4 millimetre thick veneer of approved make, shade on one side, with 4 millimetre grooves in veneer, including with support framework, pasting, screwings, cutting, jointing, finishing, fixing to the walls etc. as shown in the drawing and design provided by the Architect, and antitermite treatment to wood, plywoods etc. complete as directed by Engineer -In-Charge. EIGHTH FLOOR
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 millimetre minimum size, crossings of mild steel flats of size 18 x 5 millimetre T or E section for runner of minimum 40 x 6 millimetre size for flange, mild steel flat for top runner of minimum size 40 x 12 millimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 millimetre max. spacing of vertical channels be 100 millimetre enclosed gate position and clear space of 150 millimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). LOWER GROUND FLOOR
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diameter and vertical pipe of 38 millimetre dia at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre dia in three rows, all pipes of 2 millimetre thick including ffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre dia above newel post of 75 millimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing 40 millimetre diameter and 1.5 millimetre thick Stainless steel hand railing in Stainless steel 304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete BASEMENT2
BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one no SS 304 hinged rail 76 centimetre s and three no SS 304of (Grab Bar) 60 centimetre s all including cutting and making good the walls and floors wherever required ,seat cover, cistern and wash basin fittings,nuts, bolts and gasket etc complete as per the direction of Engineer-In-charge. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying texture plaster of STONETEX - TRAVERTINE SERIES - ST-2002 special luxurious stone finish coating (3 product type – 6 coat system) for exteriors and interiors. Texture midcoat incorporating natural stone granules like natural Sandstone, Granite, Limestone, Ceramic chips, natural sand etc. including grooves to be provide as per design and drawings. Apply two coats of under coat primer by roller or brush then apply masking tape to create grooves as per design and drawings. First coat of texture midcoat finish by spray gun, evenly over the entire surface. Apply second coat of texture midcoat finish by spray sprinkle method, evenly on the whole sea of the previously dried first coat. Apply two coats of top protective coat evenly on the surface including grooves with roller or brush. It should be water based and ecofriendly product including preparing the surface, scaffolding etc. complete as directed by Engineer in-charge. LOWER GROUND FLOOR
Providing and fixing CLADDING TYPE - 84R louvers of approved color consisting of panel 84 millimetre wide 16 millimetre deep x 0.6 millimetre thick with 30 millimetre gap with round edges panel length up to 6 Mt coil coated on continues paint Line double baked and roll formed from enameled corrosion resistance. Aluminium Alloy AA3005 (Al. Mg.) for higher strength and good roll forming characteristics Panel shall be clipped to baked enameled aluminium cladding type panel stringer of 33 millimetre wide and 86 millimetre deep X 0.95 millimetre thick in a standard Length of 5 Mt made of double baked enameled Aluminium alloy AA5050 (Al. Mg.) black with cut-outs to hold the panel in a module of 86 millimetre center to center at a distance of 1 Mt. The Carrier shall be fixed to suitable structure by means of rigid fixing details including Paint Finish : Aluminium panels shall be cromotised for maximum bond between metal and paint enameled twice under high temperature one side with full primer and luxacoat finish. The other side (Inner side) with a primer coat and skin coat on a continuous paint line etc.complete as directed by Engineer-in-charge. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Aluminum Cladding: Providing and fixing Aluminum Jali Laser cut of 2 millimetre thickness with pure polyester Matt finish exterior grade UV resistant powder coating. The jali to be fixed to the sub framing using self drilling screws which shall not be visible in the elevation. The sub framing to be anchored to the main building using Anchor fasteners. Test report to be submitted for structural stability of the system for its self weight and wind load of 120kmph. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on site. Work shall be carried our including all lead and lifts GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Structural Glazing : Providing and fixing structural glazing work of 5 millimetre tk tinted toughened glass with frame work made of aluminum RHS of size 64 millimetre x 58 millimetre color anodized as per design and drawing, aluminum sections should be confirming Indian Standard 63400 , glass pasted to frame work with approved spacer tape and DOW CORNING 995 silicon sealant and gaps between glass panels should be filled by clear Dow CORNING 789 silicon weather proofing sealant , with all necessary fasteners and accessories complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
75 millimetre thick Gypserra™ stud or equivalent partition which includes single layer of tapered edge 12.5 millimetre thick Gypboard or equivalent Plain (conforming to IS 2095 Part 1:2011, Certified board) of size 1219x2438 millimetre is screw fixed to C-stud. 48x0.5 millimetre Gypserra or equivalent C-stud {Material-IS 513, Y/S-300Mpa, Finish - AZ150 (IS 15961)} placed at 610 millimetre c/c in 50x0.5 millimetre Gypserra or equivalent {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} floor and ceiling channel. Floor and Ceiling channel is anchored to the floor and True ceiling using Gyproc or equivalent Rawl plug Ø8x45 millimetre {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti X-GN20MX anchor fasteners at 600 millimetre c/c in center line. Floor channel to be wrapped with 70µ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. A Gypserra or equivalent noggin channel {Material-IS 513,Y/S-300 Mpa, Finish - AZ150 (IS 15961)} of 48x0.5 millimetre width has to be provided at the horizontal joints of the two boards. Gyproc or equivalent boards to be screw fixed with Gyproc or equivalent drywall screws of 25 millimetre at minimum spacing of 300 millimetre at centre and 150 millimetre at periphery. 25 millimetre Glass wool slab of density 20 kilogramme /m³ shall be placed in metal framework. Glass wool holding clip should be used to hold Glass wool slab in its position. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc or equivalent Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape or fiber tape. The junction of the partition with masonry and all penetration through the partition has to be treated with Hilti/Pyroplex acoustic sealant. All other detailing and specifications to be followed as per approved drawing of Gyproc or equivalent. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
Providing and fixing Aluminium anodised logo of size 5.5m x 3.5m with building name including all fittings and fixing as per selction of project Architect. Logo image must be approved and verified by project Architect. etc complete as per direction of the Engineer-in-Charge
Conveyance of material/debris at a distance of 10 Km as directed by the Engineer-In-Charge.
PLUMBING WORK C P and Sanitary Fixtures and FittingsProviding and fixing white european type wall-hung, of size 360 millimetre x 360 millimetre x 575 millimetre with flush valve of Parriware / Hindware including soil pipe, vent pipe upto outside face of wall, 100 millimetre diameter cast iron plug bend inlet pipe all fittings,cutting and making good walls, floors etc as directed by Engineer in charge. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing white Wash basin with half pedestal of size 515 millimetre X 615 millimetre X 460 millimetre including pillar cock auto-closing system chromium plated angular stop cock long thread of approved make continental including stainless steel bottle trap of necessary pipe connection upto the outside face of the wall. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing Table top white wash basin of size 120x635x405 millimetre rubber plugs and brass chain, with pillar cock, chromium plated .Angular stop cock long thread, continental including stainless steel bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing white glazed urinal of size 710 x 460 x 300 millimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 millimetre diameter Poly vinyl chloride flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap and soil pipe connection upto the outside face of wall etc complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. Lower Ground Floor
Ground Floor
Eighth Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 millimetre incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing chromoum plated Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing chromoum plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing chromoum plated 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing 450 millimetre x 550 millimetre size superior type Belgium mirror with 16 millimetre diameter nickel plated towel rod etc. complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing Hand shower (health faucet) with 8 millimetre diameter 1 metre long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Sewarage System Providing and fixing 75 millimetre diameter stabilizer pipe / Poly vinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. (As per IS 13592-1992 Type B, 6 kilogramme /sq. centimetre pipes are reco millimetre ended for use in soil and waste discharge system) Basement 2 Floor
Basement1 Floor
Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing 100 / 110 millimetre diameter stabilizer pipe / Poly vinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. (As per IS 13592-1992 Type B, 6 kilogramme per square centimetre pipes are reco millimetre ended for use in soil and waste discharge system) Basement 2 Floor
Basement1 Floor
Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing Poly vinyl chloride Rain water pipes of 110 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Basement 2 Floor
Basement1 Floor
Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing Poly vinyl chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Basement 2 Floor
Basement1 Floor
Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing 15 centimetre rigid upoly vinyl chloride Nahani trap (Multi Floor traps, water seal not less than 50 millimetre ) including bend, connectingpiece of Upoly vinyl chloride pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete . Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Water Supply System Providing and fixing on walls/ceiling/floor 20 millimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing on walls/ceiling/floor 25 millimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing on walls/ceiling/floor 32 millimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing on walls/ceiling/floor 40 millimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing on walls/ceiling/floor 50 millimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and laying in trenches 40 millimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and laying in trenches 50 millimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and making ISI Mark ferrule connection of 50 millimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Providing and laying in trenches 50 millimetre diameter heavy grade having embossed as ISI Mark galvanised iron pipes of 6.33 kilogramme per metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and laying in trenches 80 millimetre diameter heavy grade having embossed as ISI Mark galvanised iron pipes of 10.15 kilogramme per metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and fixing screw down for 20 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing screw down for 25 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Lower Ground Floor
Ground Floor
Second Floor
Eighth Floor
Providing and fixing screw down for 32 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing screw down for 40 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Lower Ground Floor
Ground Floor
Second Floor
Eighth Floor
Providing and fixing screw down for 50 millimetre diameter wheeled stop tap of brass including necessary sockets/ union nut complete. Basement 2 Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing screw down for 65 millimetre diameter wheeled stop tap of brass including necessary sockets/ union nut complete. Basement 2 Floor
Eighth Floor
Providing and fixing screw down for 80 millimetre . diameter wheeled stop tap of brass including necessary sockets/union nut complete. Basement 2 Floor
Eighth Floor
Providing and fixing reinforced cement concrete cover of size 90 centimetre x 45 centimetre with frame over inspection chamber etc. complete. Heavy duty (225 kilogramme ) For GWT
Providing and fixing reinforced cement concrete cover of size 90 centimetre x 45 centimetre with frame over inspection chamber etc. complete. Medium duty (140 kilogramme ) For OHT
Providing and fixing 50 millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber]
Providing and fixing 45 centimetre wide mild steel ladder of 40 millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diameter mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre x 30 centimetre x 30 centimetre and painting the ladder complete. (Anti Corossive Paint)
Providing and fixing 40 millimetre diameter Ball cock medium type with poly vinyl chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
External Drainage and Rain Water System Providing , constructing and fixing 250 millimetre diameter Inspection chamber made up of Upoly vinyl chloride material of thickness 3.5 millimetre and height of 259 millimetre with inlet and outlet of 110 millimetre diameter with 75 millimetre diameter U Trap, Ultra shaft pipe of Upoly vinyl chloride material having height of 470 millimetre and fixing Ultra 250 millimetre diameter Upoly vinyl chloride cover and frame in 150 millimetre thick in cement concrete 1:2:4, having crushed sand bed of 100 millimetre thick of size 550 millimetre diameter Including excavation and refilling the sides of chamber by crushed sand cushioning 150 millimetre thickness, connecting all required Upoly vinyl chloride fittings with rubber lubricant etc. complete
Providing , constructing and fixing 450 millimetre diameter Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 millimetre and height of 388 millimetre with 160 or 200 millimetre main inlet (s) outlet and 110 and / or 160 millimetre branch inlets, with 450 millimetre diameter Ultra shaft pipe of HDPE material having height of 460 millimetre , having Reinforced cement concrete cover and frame fixing in 150 millimetre thick in c.c.1:2:4, having crushed sand bed of 150 millimetre thick of size 750 millimetre diameter Including excavation and refilling the sides of chamber by sand crushed cushioning 150 millimetre thickness, connecting all required Upoly vinyl chloride fittings with rubber lubricant etc. complete.
Providing , constructing and fixing 600 millimetre diameter Inspection chamber made up of Polypropylene / polyethylene material Having 315 millimetre diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 millimetre and 200 millimetre pipes having thickness of 5 millimetre and 600 millimetre in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 millimetre having Reinforced cement concrete cover and frame fixing in 150 millimetre thick in c.c.1:2:4, having crushed sand bed of 150 millimetre thick of size 750 millimetre diameter Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 millimetre thickness, connecting all required Upoly vinyl chloride fittings with rubber lubricant etc.complete.
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying 100 millimetre diameter salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.
Providing and laying concrete pipes of Indian Standard Non-pressure class of 150 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of Indian Standard Non-pressure class of 225 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of Indian Standard Non-pressure class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying cement concrete pipe of Indian Standard 458:2003 Non-pressure -2 class of 450 millimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and laying cement concrete pipe of Indian Standard 458:2003 Non-pressure class of 600 millimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and laying cement concrete pipe of Indian Standard 458:2003 Non-pressure-2 class of 900 millimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round glazed stoneware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced cement concrete Cover medium duty 140 kilogramme with frame etc complete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round glazed stoneware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced cement concrete Cover medium duty 140 kilogramme with frame etc complete.
Providing and Fixing 40 millimetre thick Fibrocat FRP grating (Cover) of size 1009 millimetre x 529 millimetre For gutters including loading unlonding, other taxes excluding GST etc. complele
Providing and constructing Brick Masonry inspection trap Chamber 90 centimetre x 45 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with Reinforced cement concrete Cover medium duty 140 kilogramme . etc complete
RWH - Recharge Pit Providing and constructing recharge pit of 2.0 metre deep and 1.0 metre diameter of pre-cast Reinforced cement concrete rings with 6.5 inch diameter x 25 metre deep borewell at the floor of recharge pit including installation of combination of solid/perforated poly vinyl chloride casing pipe wrapped around with netlon mesh including 300 millimetre thick sidefilling around outside of Reinforced cement concrete rings (annular space) with 40 millimetre size boulders including filling of recharge pit up to 0.5m depth with 25-75 millimetre clean washed gravels from bottom up followed by 0.5m depth of 10-25 millimetre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) media layer including covering with RCC slab, manhole frame and cover, poly vinyl chloride rungs, poly vinyl chloride end-caps, fittings etc. including arrangement for inlet and outlet pipe excavation and backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Providing, Supplying, Fixing, testing and commissioning of 15 millimetre diameter CP Brass Foot Operated Faucet Protector with Spout etc complete including all accessories as per Approved C.P and Sanitary Product sheet. All work Complete as per direction of the Engineer-in-Charge. i) Providing and Fixing of Foot Operated Faucet Protector with Spou with all accessories and required connections.(Cara SKU: F9025102) ii) Connecting the above to the waste line using CP brass connection, wall flange and 600 millimetre Long Braided Hoses with Two 15 millimetre Nuts and Rubber Washers Without Nipple etc.including core drilling slab,cutting and making good the walls where required.
Providing, Supplying, Fixing, testing and commissioning of Double Robe Hook (kohler 15247IN-CP) and Towel Rod (kohler K-25065IN-CP) Square 610 millimetre long with all necessary fixtures and fitting etc complete as directed by the Engineer-in-Charge. (Fixtures and fittings as per Approved C.P and Sanitary Product sheet). All work Complete as per direction of the Engineer-in-Charge.
Providing and Fixing it in position, Alighning to correct position, testing and commissioning of CP brass Grating (Viking 41615) of Rectangular type with openable circular lid 150 millimetre nominal size square 100 millimetre diameter of the inner hinged round grating. including setting in floor with cement motor to match with floor finish as per architect requirement complete including all accessories. All work Complete as per direction of the Engineer-in-Charge.
Providing and Fixing it in position, Alighning to correct position, testing and commissioning of CP brass Grating of Close on Top type (Viking 45290) with openable circular lid 150 millimetre nominal size square 100 millimetre diameter of the inner hinged round grating. including setting in floor with cement motor to match with floor finish as per architect requirement complete including all accessories. All work Complete as per direction of the Engineer-in-Charge.
Providing, fixing, testing and commissioning of Brass Housing Pressure Reduce Valve with balanced seat, standard pattern, set point scale, high quality synthetic material valve insert, SS wire mesh, NBR diaphragm, NBR seats, pressure gauge, complete as required in water supply drop pipes. To be installed inside shaft, on-line type. Pressure range Complete as per direction of the Engineer-in-Charge. Pressure Reduce Valve 25 millimetre diameter Lower Ground Floor
Ground Floor
First Floor
Second Floor
Providing, fixing, testing and commissioning of Brass Housing Pressure Reduce Valve with balanced seat, standard pattern, set point scale, high quality synthetic material valve insert, SS wire mesh, NBR diaphragm, NBR seats, pressure gauge, complete as required in water supply drop pipes. To be installed inside shaft, on-line type. Pressure range Complete as per direction of the Engineer-in-Charge.
Pressure Reduce Valve 32 millimeter diameter Providing, fixing, testing and commissioning of Brass Housing Pressure Reduce Valve with balanced seat, standard pattern, set point scale, high quality synthetic material valve insert, stainless steel wire mesh, NBR diaphragm, NBR seats, pressure gauge, complete as required in water supply drop pipes. To be installed inside shaft, on-line type. Pressure range Complete as per direction of the Engineer-in-Charge.
Pressure Reduce Valve 40 millimeter diameter Providing, fixing, testing and commissioning of Brass Housing Pressure Reduce Valve with balanced seat, standard pattern, set point scale, high quality synthetic material valve insert, SS wire mesh, NBR diaphragm, NBR seats, pressure gauge, complete as required in water supply drop pipes. To be installed inside shaft, on-line type. Pressure range Complete as per direction of the Engineer-in-Charge.
Pressure Reduce Valve 50 millimeter diameter Providing, fixing, testing and commissioning of Brass Housing Pressure Reduce Valve with balanced seat, standard pattern, set point scale, high quality synthetic material valve insert, SS wire mesh, NBR diaphragm, NBR seats, pressure gauge, complete as required in water supply drop pipes. To be installed inside shaft, on-line type. Pressure range Complete as per direction of the Engineer-in-Charge.
Pressure Reduce Valve 65 millimeter diameter Providing and constructing on sewer, burnt brick masonry circular manhole with concentric cone 1.2 Metre diameter at bottom and 0.5 Metre diameter at top and upto a depth of 2.00 Metre with 23 centimetre brick work in centimetre 1:4 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kilogramme , 1:2:4 coping and providing and fixing approved make and quality FRP (Fibre-reinforced plastic). frame and cover of 56 centimetre dia.etc. complete as directed by Engineerin-charge.
Providing and constructing on sewer, Burnt brick masonry circular manhole concentric cone 1.5 Metre diameter at bottom and 0.5 M diameter at top and upto a depth of 5.00 Metre with 23 centimetre brick work, upto depth of 2 Metre from top and 35 centimetre thick brick work for balance depth in centimetre 1:4 proportion with 20 millimetre thick smooth plaster on both sides in centimetre 1:2 proportion excluding excavation including foundation concrete 250 millimetre thick and haunches and channels in cement concrete 1:2:4 proportion, finishing channels in smooth rendering, providing cast iron dapuri type steps each weighing 5.5 kilogramme ., 1:2:4 coping and providing and fixing approved make and quality FRP (Fibre-reinforced plastic) frame and cover of 56 centimetre diameter etc. complete as directed by Engineerin-charge.
Providing and constructing Burnt brick masonry valve chamber with 15 centimetre thick 1:3:6 proportion plain cement concrete bedding, excluding excavation, burnt brick masonry in centimetre 1:5 proportion precast FRP. frame and cover, etc. complete as directed by Engineer-in-charge. As above of 90 x 60 centimetre internal size and depth upto 1.2 M with FRP. frame and cover.
As above of 90 x 90 centimetre internal size and depth upto 1.2 M with FRP. frame and cover.
Providing and Fixing Chlorinated Polyvinyl Chloride (chlorinated poly vinyl chloride ) Pipes of 65 millimetre nominal outer dia pipes, having thermal stability for hot and cold water supply, including all chlorinated poly vinyl chloride plain and brass threaded fittings. This includes jointing of pipes and fittings with one step chlorinated poly vinyl chloride solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer. Basement 2 Floor
Basement1 Floor
Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and Fixing Chlorinated Polyvinyl Chloride (chlorinated poly vinyl chloride ) Pipes of 80 millimetre nominal outer dia pipes, having thermal stability for hot and cold water supply, including all chlorinated poly vinyl chloride plain and brass threaded fittings. This includes jointing of pipes and fittings with one step chlorinated poly vinyl chloride solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer. Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Providing and fixing Cast Iron Wafer Type Butterfly Valve Without Lugs, Lever Operated, stainless steel-304 Disc, Nitrile/EPDM Rubber Lining with hand lever operation. Tested to a pressure not less than 16 kilogramme per square centimetre . Including rubber gasket, flanges, nuts, bolts, washers and painting complete as required. Complete as per direction of the Engineer-in-Charge. 65 millimetre diameter
80 millimetre diameter
Providing and Fixing Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required. All work Complete as per direction of the Engineer-in-Charge. 50 millimetre diameter
65 millimetre diameter
80 millimetre diameter
Providing supplying and fixing of approved make 25 millimetre dia Auto Air vent for cold water supply risers. Body in brass UNI EN-12165:98, Plug in brass UNI EN-12165:98, Flot in polypropylene (PP). suitable for pressure not less than 10 kilogramme per square centimetre , with unions etc. Complete as per direction of the Engineer-in-Charge.
RT1 -RECEPTION TABLE TABLE Providing and fixing table in "C" shape of size 3.3 metre x 1.20 metre having height of 750/1200 millimetre as shown in drawing,Table to be made up of 19 millimetre thick plywood for verticle, top, drawers, cabinates, foot rest of Century make COMMERCIAL ply BWR grade Conforming to ISI-303 or equivalent make, The top and facia shall be finished with , 4 millimetre thick veneer finish to ply surface as per detailed drawing, inner side to be finished with 0.8 millimetre thick laminate of royal touch or equivalent make confirming to (ISI 2046) including antitermite treatment, melamine polishing 2 coat to all veneer surface, fevicol, nails, cable manager, hinges, knobs, slidding chanels of hafele or equivalent make,with required labours etc. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Ground Floor
T2 -MEETING TABLE, Providing and fixing meeting hall table of size 5.6 m x 0.75 m, having height of 0.75 m as shown in drawing made up of 19 millimetre thick plywood of Century make COMMERCIAL ply BWR grade Conforming to ISI-303 or equivalent make, The top, front and facia shall be finished with solid surface 6 millimetre thick, veneer 4 millimetre thick finish to ply surface as per detailed drawing, top surface bottom to be finished with 0.8 millimetre thick laminate of royal touch or equivalent make confirming to (ISI 2046), antitermite treatment, melamine polishing two coat to all veneer surfaces fevicol, nails, cable manager, labours, material testing charges etc.. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Second Floor
TABLE Director Cabin Providing and fixing table in "C" shape of size 2.7 metre x 1.05 metre, side table 1.0 m x 0.45 metre, back side table 2.7 metre x 0.45 metre having height of 750 millimetre as shown in drawing made up of 12 millimetre and 19 millimetre thick plywood conforming to ISI-303, The top and exposed surface shall be finished with 4 millimetre thick of approved veneer , at top surface only wooden beading 12 millimetre x 40 millimetre finished with melamine polish, all the support Plywood with 19 millimetre thick plywood Conforming to ISI-303 , internal surfaces finished with 0.8 millimetre thick laminate, including provision for cable manager,, plywood foot rest finished with 1 milimeter thick laminate, including shutters and drawers with telescopic sliders of required sizes, handles, lock, hinges, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
CORNER WORKSTATION 1350x1350x600x1200 millimetre height. (CLUSTER OF 1) Providing and fixing of workstations System 50 millimetre thick Tile Base Partition System at 1200 millimetre height, 1st Module with Prelam particle board Tile, 2nd Module Pin-up, Marker and Fabric Tile, Electrical connection below the worktop on Raceway and Skirting Level, Table Top considered in 25 millimetre thick prelam particle board finish with poly vinyl chloride lipping 2 millimetre thick having height 727 millimetre from Ground Level, Understructure with Prelam Gable Ends with Brackets and Return Prelam Combo Storage having size 750x400x 727 millimetre etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
CORNER WORKSTATION 1350x1350x600x1200 millimetre height . (CLUSTER OF 6) Providing and fixing of workstations system 50 millimetre thick Tile Base Partition System at 1200 millimetre height,1st Module with Prelam particle board Tile, 2nd Module with Pin-up, Marker and Fabric Tile, Electrical fitting Below the worktop on Raceway and Skirting Level, Table Top considered in 25 millimetre thick prelam particle board finish with poly vinyl chloride lipping 2 millimetre thick. Worktop height 727 millimetre from Ground Level, Understructure with Prelam Gable Ends with Brackets, Return Prelam Combo Storage having size 750x400x 727 millimetre etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Seventh Floor
CORNER WORKSTATION 1350x1350x600x1200 millimetre height. (CLUSTER OF 4) Providing and fixing of workstations System 50 millimetre thick. Tile Base Partition System at 1200 millimetre height, 1st Module with Prelam particle board Tile, 2nd Module with Pin-up, Marker and Fabric Tile, Electrical fitting below the worktop on Raceway and Skirting Level, Table Top considered in 25 millimetre thick prelam particle board finish with poly vinyl chloride lipping 2 millimetre thick having height 727 millimetre from Ground Level, Understructure with Prelam Gable Ends with Brackets, Return Prelam Combo Storage having size 750x400x 727 millimetre . etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
CORNER WORKSTATION 1350x1350x600x1200 millimetre height. (CLUSTER OF 2) Providing and fixing of workstations System 50 millimetre thick Tile Base Partition System at 1200 millimetre height, 1st Module with Prelam particle board Tile, 2nd Module with Pin-up, Marker and Fabric Tile, Electrical fitting below the worktop on Raceway and Skirting Level, Table Top considered in 25 millimetre thick prelam particle board finish with poly vinyl chloride lipping 2 millimetre thick. having height 727 millimetre from Ground Level, Understructure with Prelam Gable Ends with Brackets. Return Prelam Combo Storage having size 750x400x 727 millimetre .etc complete. All samples muct be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
CORNER WORKSTATION 1350x1350x600x1200 millimetre height. (CLUSTER OF 3) Providing and fixing of workstations System 50 millimetre thick Tile Base Partition System at 1200 millimetre height, 1st Module with Prelam particle board Tile, 2nd Module Pin-up, Marker and Fabric Tile, Electrical connection below the worktop on Raceway and Skirting Level, Table Top considered in 25 millimetre thick prelam particle board finish with poly vinyl chloride lipping 2 millimetre thick having height 727 millimetre from Ground Level, Understructure with Prelam Gable Ends with Brackets and Return Prelam Combo Storage having size 750x400x 727 millimetre etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
High Back Revolving Chairs Providing and fixing High Back Revolving Chair Chair in Moulded Ply with Head rest, PU foam in Back and Moulded PU Seat, "T" Adjustable Arms , Synchronized Multi Lock Mechanism, Aluminium Base, and Gas Lift. as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Back Height - High Back Back Finish - Mesh with Adjustable Lumber Support Back Mesh Color - Black Seat Finish - Fabric (with centimetre Foam) Seat Fabric Color - Black Seat Height Adjustment - Pneumatic Mechanism Type - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - 1-D Adjustable Armpads Type - Polyurethane Base Type - 5-Star in Black Nylon Lower Gropund Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Mid Back Sledge Base Providing and fixing Medium Back Chair with SS sledge base Chair in Moulded Ply, PU foam in Back and Moulded PU Seat, "T" Adjustable Arms , with SS sledge base.as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. SPECIFICATIONS: Back Height - Medium Back Back Finish - Mesh with Adjustable lumber support Back mesh colour and seat colour - Black Seat Height Adjustable with gas Lift. Mechanism Type - Synchronized Tilt Back Lock - Upright position Back Tilt Tension - Adjustable Armrests Type -1D PU Arms Base Type - Black Nylon 5-Star Base. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Low Back Sledge Base Providing and fixing Low Back Chair with SS sledge base Chair in Moulded Ply with Head rest, PU foam in Back and Moulded PU Seat, Adjustable Arms, With SS sledge baseas per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Fix Chair with Four Leg Providing and fixing Fix Lounge Chair Chair With Stainless Steel Frame in front 25 millimetre dia and Back Leg Rectangle pipe . 12 millimetre Moulded ply in Seat and Back duly Cushioned with PP Arms as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Dinning Chairs Providing and placing injection molded Polypropylene without handle chair of size 450 millimetre x 560millimetre and height 815 millimetre made up of primarily of 7/16" diameter steel rod with fire retardant power coating, injection molded Polypropylene seat and back etc. complete as per drawing and image. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Ground Floor
Ground Floor
Eight Floor
Three Seater Sofa Providing and fixing Frame in Hardwood fully Cushioned in Seat and Back, with arms. Stainless Steel Legs at the base. Three Seater Sofa - 1950 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve- Seat 550 millimetre , as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Gropund Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Two Seater Sofa in Waiting Area Providing and fixing Frame in Hardwood fully Cushioned in Seat and Back, with arms. Stainless Steel Legs at the base. Two Seater Sofa - 1350 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve- Seat 550 millimetre , as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
One Seater Sofa in Waiting Area Providing and fixing Frame in Hardwood fully Cushioned in Seat and Back, with arms. Stainless Steel Legs at the base. One Seater Sofa - 750 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve- Seat 550 millimetre , as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Gropund Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Center Table in Ante Chamber Providing and fixing Table in Stainless Steel Square pipe frame of 25 millimetre x 16g. Top and bottom with Smoke Glass with polished edges of 12 millimetre thk. Size:- 750 millimetre L x 750 millimetre W x 450 millimetre height as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Center Table in Waiting Area ( 750 millimetre x 750 millimetre ) Providing and fixing Table Table With Top in BSL of 25 millimetre thk with all Sides Edge Banding, Frame in Stainless Steel / M.S Powder Coating with 25 millimetre square pipe of 16g.table Size 750 millimetre L x 750 millimetre W x 450 millimetre height as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Side Table in Ante Chamber Providing and fixing Table in Stainless Steel Square pipe frame of 25 millimetre x 16g. Top and bottom with Smoke Glass with polished edges of 12 millimetre thk. Size:- 900 millimetre L x 600 millimetre W x 450 millimetre height as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
eventh Floor
Eight Floor
Side Table in Waiting Area Providing and fixing Table With Top in BSL of 25 millimetre thk with all Sides Edge Banding, Frame in Stainless Steel / M.S Powder Coating with 25 millimetre square pipe of 16g, table Size 600 millimetre L x 600 millimetre W x 450 millimetre height, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Curtains_AT 8TH FLOOR Zebrano Providing and fixing curtains MAC - Zebrano for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete as directed by Engineer In Charge. Eight Floor
Curtains_For al floor except 8th floor and conference and meeting Providing and fixing Roller Blind MAC - SCREEN LI-S3 - Sand for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete as directed by Engineer In Charge. Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Curtains_Conference and Computer Lab Providing and fixing Curtains/Blinds MAC - BLACKOUT TORINO TR 5408 for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Help desk _Credenza- AT VIP LIFT LOBBY Providing and fixing Table of size 1.7 Metre x 0.4 Metre and top portion 1.7 Metre x 0.4 Metre having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, knobs etc. as per working drawing, at Ground floor.etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Help desk _Credenza- AT OTHER LOCATIONS Providing and fixing Table of size 1.5 M x 0.45 M and top portion 1.5 M x 0.45 M having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Help desk _Credenza Deluxe Room Providing and fixing Table of size 1.35 Metre x 0.4 Metre and top portion 1.35 Metre x 0.4 Metre having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Eighth Floor
Help desk _Credenza Reception ( 3.3 metre X 0.45 metre ) Providing and fixing Table of size 3.3 Metre x 0.45 Metre and top portion 2.4 Metre x 0.45 Metre having finished with white unicore laminate having height of 0.75 meter made up of 19 millimetre thick plywood and back made up of 12millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
Conference Table Providing and fixing conference room table top of 'C' shape size 5.3 m x 0.75 m, and 2.13m x 0.75m having height of 0.75 m with verticle supports, footrest, architectural shape as shown in drawing made up of 12 millimetre and 19 millimetre thick plywood of Century make COMMERCIAL ply BWR grade Conforming to ISI-303 or equivalent make, The top and facia shall be finished with solid surface 6 millimetre thick, veneer finish to ply surface as per detailed drawing,inner sides to be finished with 1 millimetre thick laminate , foot rest to be finished with 0.8 millimetre thick laminate of royal touch or equivalent make confirming to (ISI 2046), , antitermite treatment, melamine polishing two coat to all veneer surface, fevicol, nails, cable manager, labours,material testing charges . All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Veneer Wall Panelling P1,P2,P3 Providing and fixing wall panal 19 millimetre thick plywoods shown in drawing made up of BWR grade 19 millimetre thick plywood panel fixed on 19 millimetre ply grid finished with 4 millimetre veneer and provide 4 millimetre thick groove on panal as shown in drawing and design supplied by the project architect and work must be done as directed by engineer in charge Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
TV UNIT Providing and fixing TV Unit of size 1.5 metre x 0.30 metre, having height of 450 millimetre as shown in drawing made up of 19+19 millimetre thick plywood conforming to ISI-303, The top shall be finished with veneer, all the support Plywood Conforming to ISI-303 19 millimetre thick finished with white laminate, internal surfaces finished 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires,including shutters, handles, lock, hinges, cable manager, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Double Bed Providing and fixing Double Bed of size 1.86 x 2.2 metre having height of 450 millimetre as shown in drawing. Bed to be made up of 19 millimetre thick plywood for framework of bed and head board confirming to ISI- 303 .The top and headboard shall be finished with 19 millimetre thick ply and 1milimetre thick laminate as shown in the design and drawing provided and supplied by the project architect including labour ,fixtures and fastenings ,nails,fevicol,material testing charges etc. and work must be done as directed by Engineer -In-Charge. Eighth Floor
WALL Painting Providing and fixing Wall Painting up to size 0.9 Metre X 1.2 Metre as shown in drawing and design supplied by the Architect etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Gropund Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Compactor- TM2 - TWIN MOBILE Providing and fixing in position Godrej MakeTM2 - TWIN MOBILE Drive 3 Bay Push Pull Type Unit of Optimizer ( Storage solution of size 457DX915WX1980H milimeter made out of 0.8 millimetre thick CRCA (Colled Rolled Colad Annealed) Steel Conferming to indinan Standard:513 grade, Having 5 Loading level Formed by 4 no Adjustable Shelves, finished with fire retardent epoxy polyster powder coating of approved colour and shade with dry film Thickness of millimetre 40 microns overbaked with a controleed temprature of 180 deg. C to 200 degree C the undercarriage made up welded frame of HR sheet 3.15 millimetre Thick Conferming to Indian standard: 10748 suitably fabruicated to taken the load base on confriguation having fastners labour etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Gropund Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Compactor- LD3-single last drive unit Providing and fixing in position Godrej Make LD3-single last drive unit 3 Bay Push Pull Type Unit of Optimizer ( Storage solution of size 457DX915WX1980H milimeter made out of 0.8 millimetre thick CRCA (Colled Rolled Colad Annealed) Steel Conferming to indinan Standard 513 grade, Having 5 Loading level Formed by 4 no. Adjustable Shelves, finished with fire retardent epoxy polyster powder coating of approved colour and shade with dry film Thickness of millimetre 40 microns overbaked with a controleed temprature of 180 deg C to 200 degree C the undercarriage made up welded frame of HR sheet 3.15 millimetre Thick Conferming to Indian standard 10748 suitably fabruicated to taken the load base on confriguation having fastners labour etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Gropund Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Compactor- SD3-single Static Drive cover unit Providing and fixing in position Godrej Make SD3-single Static Drive cover unit 3 Bay Push Pull Type Unit of Optimizer (Storage solution of size 457DX915WX 1980H milimeter made out of 0.8 millimetre thick CRCA (Colled Rolled Colad Annealed) Steel Conferming to indinian Standard 513 grade. Having 5 Loading level Formed by 4 no. Adjustable Shelves, finished with fire retardent epoxy polyster powder coating of approved colour and shade with dry film Thickness of millimetre 40 microns overbaked with a controleed temprature of 180 deg. C to 200 degree C the undercarriage made up welded frame of HR sheet 3.15 millimetre Thick Conferming to Indian standard: 10748 suitably fabruicated to taken the load base on confriquation having fastners labour etc.complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Gropund Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Compactor- TM2 - TWIN MOBILE Providing and fixing in position Godrej Make TM2 - TWIN MOBILE Drive 2 Bay Push Pull Type Unit of Optimizer ( Storage solution of size 457DX915WX1980H milimeter made out of 0.8 millimetre thick CRCA (Colled Rolled Colad Annealed) Steel Conferming to indinan Standard:513 grade, Having 5 Loading level Formed by 4 no. Adjustable Shelves, finished with fire retardent epoxy polyster powder coating of approved colour and shade with dry film Thickness of millimetre 40 microns overbaked with a controleed temprature of 180 deg C to 200 degree C the undercarriage made up welded frame of HR sheet 3 15 millimetre Thick Conferming to Indian standard: 10748 suitably fabruicated to taken the load base on confriguation having fastriers labour etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Gropund Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Guide Rails Providing and fixing Guide Rails made out of 28 millimetre dia bar placed on 1.2 millimetre thick MS plate above the floor level having standard of safety etc. Complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Basement 1
Lower Gropund Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
8 Seater Dining Table Providing and Fixing 8 Seater Dining Table of Size :1200x2500 750 millimetre height. Main table tops to be made up of 25 millimetre thick prelaminated particle board positioned at 750 millimetre high from ground level. understructure Legs should be made of CRCA pipe with round shape with Powder coated etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Lower Ground Floor
Eight Floor
4 Seater Round Dining Table Providing and Fixing 4 Seater Round Dining Table of Size :600 millimetre and 750 millimetre height. Main table tops to be made up of 25 millimetre thick prelaminated particle board positioned at 750 millimetre high from ground level. understructure Legs should be made of CRCA pipe with round shape with Powder coated etc. complete as directed by Engineer -IN-Charge. Lower Gropund Floor
Ground Floor
L-Size Table Pa cabin Providing and fixing table in "L" shape of size 1.35 metre x 0.6 metre, side table 1.05 metre x 0.38 metre, having height of 750 millimetre as shown in drawing made up of 12 millimetre / 19 millimetre thick plywood conforming to ISI-303, The top shall be finished with 4 millimetre thick veneer with wooden beading 12 millimetre x 40 millimetre finished with neutral matte polish, all the support Plywood Conforming to ISI-303 19 millimetre thick finished with partly grey and white laminate, internal surfaces finished 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires, plywood foot rest finished with 0.8 millimetre thick laminate, including shutter and drawers with telescopic sliders , handles , lock, magent, cable manager, hinges etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc.complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
Auditorium Chair Providing and fixing Auditorium Chair in Moulded Ply with Head rest, PU foam in Back and Moulded PU Seat, "T" Adjustable Arms, Aluminium Base, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
Carpet Providing and fixing 100% Nylon carpet with rubber backing (Flotex Flooring) having thickness of 4.3 millimetre with 600 GSM by using pidilite white glue on leveled surface and colour, design as approved by Architect etc complete. Carpet fabric must be hand washable and colour should not get dull after washing. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Cabinet In Conference Providing and fixing 0.60 metre height cabinate of 0.45 metre depth and 3.6 metre long having shutters and drawers at frontside, made up of 19 milimeter thick plywood conforming to IS-303, finished with 4 milimeter thick veneer confirming to IS 2046 and inner surfaces with 0.8 millimetre thick laminate , melamine polishing two coats to veneer surfaces including handles, lock, magent, hinges, knobs , material testing charges , Labours etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Round Side Table 200 millimetre in Waiting Area Providing and fixing Table With Top in BSL of 25 millimetre thk with all Sides Edge Banding, Frame in Stainless Steel / M.S Powder Coating with 25 millimetre square pipe of 16g, table Size 300 millimetre . 600 millimetre height, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge.n-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Meeting Hall Chair Providing and fixing Meeting hall Chair in Moulded Ply with Head rest, PU foam in Back and Moulded PU Seat, "T" Adjustable Arms, Aluminium Base, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Library 4 Seater Round Study Table Providing and Fixing 4 Seater Round Study Table of Size :600 millimetre and 750 millimetre height. Main table tops to be made up of 25 millimetre thick prelaminated particle board positioned at 750 millimetre high from ground level. understructure Legs should be made of CRCA pipe with round shape with Powder coated etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Third Floor
Library Book Shelf Providing and Fixing Book Shelf of Size 900 x 300 millimetre and 1800 millimetre height. Main table tops to be made up of 25 millimetre thick prelaminated particle board etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Third Floor
Library Magazine Stand Providing and Fixing Library Magazine Stand Of Size 400 millimetre and 1400 millimetre height Positioned At height of 400 millimetre From Floor Level As Shown In Drawing etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Second Floor
Third Floor
Library Study Table Providing and Fixing 1 Seater Study Table of Size :950 millimetre x 600 millimetre and 750 millimetre height. Main table tops to be made up of 25 millimetre thick prelaminated particle board positioned at 750 millimetre high from ground level. understructure Legs should be made of CRCA pipe with round shape with Powder coated etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Third Floor
Wardrobe In Deluxe Room Providing and fixing factory readymade Wardrobe in "L" shape of one side size 2.4 metre long x 0.6 metre wide, and another side size 1.5 metre x 0.6 metre, having height of 2.1 metre as shown in drawing made up of plywood and finished with laminate. Wardrobe must have key and lock system with inbuilt legs at bottom of height 50 millimetre . laminate colour shade must be as per selction and approval of project Architect. Product must have at least one year manufacturer waranty for defects in plywood, fixers, locks etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Eight Floor
Curtains_Conference 1 Room con/meeting Providing and fixing Roller Blind MAC - BLACKOUT GRACIA BGR5606 for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Dressing Table Providing and fixing factory made Dressing Table of size 1.35 metre long x 0.4 metre wide of height 1.8 metre dressing table must be fixed at height of 450 millimetre from floor level with 8 millimetre thick saint gobain mirror of size 1.35 metre x 1.5 metre with back support as per requirement including fixing clips, holdfasts, chrome plated fixers etc complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Eight Floor
Mattress for Double Bed Providing and supplying mattress for Double Bed of size 1.86 metre x 2.2 metre, having 150 millimetre thick twin support with high resilience layer, rebonded foam of Medium grade: 25-28 kilogramme /m³ +/- 5% with germ protection layer for the same, Matterss must be well finished appearance, homogenous quality, free of any visible imperfections and/or defects No damage like cracks or holes etc complete. All samples muct be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Eight Floor
Mattress for Single Bed Providing and supplying mattress for Single Bed of size 1.05 metre x 2.2 metre, having 115 millimetre thick twin support with high resilience layer, rebonded foam of Medium grade: 25-28 kilogramme /m³ +/- 5% with germ protection layer for the same, Matterss must be well finished appearance, homogenous quality, free of any visible imperfections and/or defects No damage like cracks or holes etc complete. All samples muct be approved by the Project Architect and work must be done as directed by Engineer -In-Charge. Eight Floor
Single Bed Providing and fixing Single Bed of size 1.05 x 2.2 metre having height of 450 millimetre as shown in drawing. Bed to be made up of 19 millimetre thick plywood for framework of bed and head board confirming to ISI- 303 .The top and headboard shall be finished with 19 millimetre thick ply and 1milimetre thick laminate as shown in the design and drawing provided and supplied by the project architect including labour ,fixtures and fastenings nails,fevicol,material testing charges etc. and work must be done as directed by Engineer -In-Charge. Eight Floor
SUB WORK -1 : Providing Internal electrification for new adminsitrative building for Education Department (B2+B1+LG+G+8 Floor) at city serve no -832 ,Final Plot no 173, Bhamburda, Shivajinagar, Pune LT Panels -Supply Installation, testing and commissioning of Main LT Auto changeover Panel . Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. As per spacification (SW-MCB,SW-MCCB, SW-ACB,CP-BB,CP,WG MA/BW,WG-MA CON )Panel shall be Indoor type (IP-42). Panel Shall Be As per IEC-60439. FORM OF SEPERATION SHALL BE FORM-4. ALL ACBS WITH - PHASE INDICATION WITH SWITCH POSITION. FOR ALL MCCB OUTGOINGS FOR SWITCH ON OFF & TRIP INDICATION. PROTECTIONS: SURGE PROTECTION ON INCOMER SINGLE PHASING PREVENTER ON INCOMING BUS FOR PHASE INBALANCE AND SINGLE PHASE PREVENTIONS PANEL SHALL CONSIST OF AUTO CHANGEOVER LOGIC ALL INCOMER SHALL HAVE MULTIFUNCTION METER ALL METERS SHALL BE COMMUNICATION CAPABLE INCOMER-1- MSEDCL Incomer- 800 A FP ACB, 42 KA AS INCOMER FOR MAIN LT PANEL-1 WITH LSI MP BASED PROTECTION With Bowden Wire for interlocking INCOMER-2- DG SET Incomer 800 A FP ACB, 42 KA EDO TYPE AS INCOMER FOR CHANGE OVER PANEL DG 1 INCOMER WITH LSI MP BASED PROTECTION OUTGOING-315 A TP MCCB 36 KA AS OUTGOING FEEDER FOR BBT -1 WITH LSI MP BASED PROTECTION OUTGOING-315 A TP MCCB 36 KA AS OUTGOING FEEDER FOR BBT -2 WITH LSI MP BASED PROTECTION OUTGOING-125 A TP MCCB 16 KA AS OUTGOING FEEDER FOR LIFT LOAD DB WITH LS TMD PROTECTION OUTGOING-63 A TP MCB 10 KA AS OUTGOING FEEDER FOR PLUMBING DB WITH LS TMD PROTECTION OUTGOING-315 A TP MCCB 36 KA AS OUTGOING FEEDER FOR FIRE FIGHTING PANEL WITH LSI MP BASED PROTECTION OUTGOING- 160 A TP MCCB 16 KA AS OUTGOING FEEDER FOR AUDITORIUM MAIN LT PANEL WITH LS TMD PROTECTION OUTGOING- 100 A TP MCCB 16 KA AS OUTGOING FEEDER FOR COMMON UTILITY LOAD PANEL WITH LS TMD PROTECTION OUTGOING- 63 A TP MCB 10 KA AS OUTGOING FEEDER FOR UPS PANEL-1 WITH LS TMD PROTECTION OUTGOING-63 A TP MCB 10 KA AS OUTGOING FEEDER FOR UPS PANEL-2 WITH LS TMD PROTECTION OUTGOING-315 A TP MCCB, 36 KA AS OUTGOING FEEDER FOR MAIN LT PANEL-1 APFC PANEL WITH LSI MP BASED PROTECTION 2 NOS OF OUTGOING-315 A TP MCCB, 36 KA AS OUTGOING FEEDER FOR SPARE WITH LSI MP BASED PROTECTION 2 NOS OF OUTGOING- 160 A TP MCCB, 16 KA AS OUTGOING FEEDER FOR SPARE PANEL WITH LSI MP BASED PROTECTION
Supplying and erecting 250kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP/APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
Distribution Boards with RCCB, MCB & MCCB Supplying, erecting & marking SPMCB 6A to 32A, C-series Each (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series Each (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6 A to 32A in Each provided distribution board as per specification no. SW- SWR/MCB
Supplying, erecting & marking TPN MCB 40A to 63A, C- Each series in provided distribution board as per specification no. SW-SWR/MCB
Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/ 25A complete as per specification no. SW-RCCB/RCCB
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW- RCCB/RCCB
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 6 poles for outgoing SP MCB’s on iron/GI frame as per specification no.SW- WR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 10 poles for outgoing SP MCB’s on iron/ GI frame as per specification no. SW- SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 poles, on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 24 poles, on iron/ GI frame/wooden board.(horizontal busbar type) as per specification no. SW- SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP /TP MCBs of 12 poles/4 ways, on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles) on iron/ GI frame. (vertical busbar type) as per specification no. SW- SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution Each board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) , on iron/ GI frame. (vertical busbar type) as per specification no. SW- SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP / TP MCBs of 36 poles/12 ways on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Providing & erecting 3 Pole MCCB upto 100A, 415V, withshort circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 3 Pole MCCB of 200A,415V capacity with short circuit rating 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
LT Cables & End Termination Supplying, erecting & terminating XLPE armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
pplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating 1100 V. 3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½core 240 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Mains Wiring Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & erecting mains with 4x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG- MA/BW
Supplying & erecting mains with 1x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG- MA/BW
Supplying and erecting HMS PVC conduit 20 mm dia. with PVC accessories on wall / ceiling as per specification No:WG-MA/CON.
Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG- MA/BW
Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 1x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG- MA/BW
Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG- MA/BW
Supplying & erecting mains with 1x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Point Wiring Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete Note: Add Rs 57/- for additional two module box with double mounting plate if required.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting ISI mark modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting ISI mark modular type bell indicator, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular pop up Box 8 module erected with provided AV/ HDMI , RJ 45,6 A electrical sockets and switch on provided table .
Light Fittings & Fans Supplying and erecting LED square / circular 5 to 8W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED flexible strip light 5m length upto 25W conforming IP 65 of any colour with driver complete.
Supplying & erecting 15W LED series PAR lights by making necessary arrangement/recess in wall to make it flush with surface.
Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fresh air cum exhaust fan of light duty250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner
BUS BAR TRUNKING- Supplying, installing, testing and commissioning of 315 A Al , FP 4W+PE , IP-55, Air Insulated Type Aluminium Busduct, 415V 25kA for 0.1 Sec Straight Length 3 Mtrs With 3 + 3 outlets. Earthing type shall be Integral. Neutral Shall be 100%. Busbar truncking Compliance Standards shall be IEC-61439-6. General Construction of Busduct Air-Insulated Type of Conductor Aluminum alloy Compliance with Standards :- C61439-6 Type Test Certification for Plug in Points :- IEC61439-6 Configuration of Busway 3L+N+PE Neutral 100% Earthing Type Integral Degree of Protection IP55 for Indoor Mechanical Impact Resistance IK10 Joint Block Single Bolt joint, Insulation Class F (155C), mechanical Strength certification up 1k 10 Material Conductor Material Aluminium Enclosure Material Galvanized sheet steel - 0.8 mm thickness
Supplying, installing, testing and commissioning of Flange End, Flange end shall be suitable for 315 Amp busbar truncking with required all accessories.
Supplying, installing, testing and commissioning of End Cover suitable for 315 Amp Busbar truncking with required all accessories.
Supplying, installing, testing and commissioning of cable termination Box suitable for 315 Amp Busbar truncking with required all accessories. End termination boq shall be sutable for inddor application
Supplying, installing, testing and commissioning of Hanger Bracket supports. Hanger Brackets supports shall be suitable for 315 Amp Busbar truncking with required all accessories complete. .
Supplying, installing, testing and commissioning of Vertical Spring Hanger. Vertical spring hanger support shall be suitable for 315 Amp Busbar truncking with required all accessories complete.
Supplying, installing, testing and commissioning of 100 A TP MCCB Tap Off Boxes
Cable Trays Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware in approved manner.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
UPS & Inveter Supplying & erecting on line UPS pure sine wave of 10 Each kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per
Supplying, erecting, testing and commissioning self?contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres/hr and storage capacity 80 litres with partially stainless steel body complete. specification no. APWCR/ WC
Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps, storage capacity of purified water 7 to 8 litre with activated carbon filter and softener operating on 230 V single phase A.C. supply.
SUB WORK -2 : Providing external electrification for new adminsitrative building for Education Department (B2+B1+LG+G+8 Floor) at city serve no -832 ,Final Plot no 173, Bhamburda, Shivajinagar, Pune - HT Cable & Termination Supplying , erecting & terminating 3 x 240 sq. mm. aluminium 11 kV(E), XLPE armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no. CB-HT (NOTE:- For round armouring)
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying & erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification no. CB-CIP
Earthing & Lightning Conductor Providing pipe type earthing with 40mm. dia. G.l. pipe or Each 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.
Providing earthing with galvanized iron earth plate size 60 x Each 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner.
HT Equipments Supplying, erecting, testing and commissioning 11 KV HT metering cubical (compact type) approved by MSEDCL/licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25 x 6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( CT, PT cover) interlock with meter doors, epoxy coated 3 nos CT having required ratio between 5/5A to 50/5A, VA10,Class0.5S, 11000/V3/110/V3 VA 50, class 0.5 epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc. complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation
Supplying , erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 5 way outdoor, extensible motorised SCADA compatible RMU as per electric supply company specification consisting of 2 nos. feeder with load break switch and 3 nos. feeder with VCB as per specification no. SW-HTS / RMU SCADA (2LBS +3VCB)
Supplying and Erecting approved make compact substation with 500 kVA, 3 phase, 50 Hz. ONAN type thermal class K10, 21 kA for 3 sec. SF6 insulated non-extensible compact switchgear (type DV-NE/ RT2-NE) consisting of one no direct cable module and one no fixed manual vacuum circuit breaker in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMTL + Inst.) protection. interconnection between HT switchgear and transformer shall be using 1Cx3x150 sq.mm aluminium XLPE cable. Copper wound transformer 500 kVA 11 kV/ 433V DYn11 oil filled, indoor type transformer bushings, hermetically sealed transformer with corrugated wall, out conservator type of design & top normal porcelain bushings for HT & LT with off load tap switch of rating +5% to - 10% @2.5%. temp rise - oil/winding 40/45°C losses (subject to IS 1180 energy efficiency level 2 ) - max @ 50% loading : as per IS 1180 and max @ 100% loading : as per IS 1180 and impedance as per IS 1180 with LV panel-800 amps aluminium busbar ( 100% for phase and 50% for neutral, current density - 1amp/sqmm) with outgoings 800 A 433V 4P 50Hz 35 kA ICOG, fixed manual type air circuit breaker (ACB) with microprocessor based release for overload , short circuit & earth fault protection., multifunctional meter with class 1.0Accuracy with RS 485 Port, RYB, ON/OFF trip indications, outdoor enclosure having IP54 degree of protection for HT < switchgear compartment & IP23 degree of protection for transformer compartment, powder /colour coated enclosure, with interconnection between HT switchgear & transformer using 1Cx3x150 Sq.mm XLPE aluminium single core cable. interconnection between transformer & LT switchgear using aluminium busbars. internal earthling connections by using 50x6 mm GI strips including transformer neutral, complete with necessary permissions of Electrical Inspector as per specification no. SS-TR/COMP
DG Set - Supplying, erecting and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of above 400 kVA upto 500 kVA capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN- AMF.
Civil Work Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying & laying (including excavation) 15 cm dia half round RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Supplying & laying (including excavation) 15 cm dia RCC Hume pipe with coupling collar of standard thickness at required depth up to 90 cm below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and spreading stone metal 25 mm size for 100mm depth above the ground level complete.
Making cement concrete foundation in 1:3:6 cement concrete (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminum paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing pair of duly tested rubber hand gloves as per IS:47705 suitable for working upto 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV
Supplying and erecting LED Street light fitting suitable for above 40W to 48W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No . FG-ODF/FLS2
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Pumping System Supplying and erecting D.O.L. Starter 400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P
Supplying and erecting pump protection relay comprising current sensing phase failure and UV+OV relay with dry run and overload protection suitable for 3 phase pumps.
Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying and erecting flat flexible 3 core 1.5 sq mm PVC heathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting Water lavel controller 230/ 415V AC., Four way for under ground & Over head tank operation.
Supplying & erecting automatic control panel for 1 Ph, 230 volt, a.c.. Submersible/centrifugal pump set upto 2 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection.
Supplying & erecting Float sensor switch for water level controller working on 250V & rated current 8A, with 2 mtr.wire & High quality of wire & plastic body
Supplying & erecting Dewatering Submersible pump set 415V, 3 phase, 50C/s, A.C. supply of 1.5 KW/ 2 H.P., of 2 to 17 m head with 600 to 100 LPM discharge, non-clogging minimised abrasive wear, large impeler clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP
Supplying and erecting D.O.L. Starter 400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P
Supply, installation, testing and commissioning of Skid mounted Hydro-pneumatic Fixed speed system with Vertical in line pump set with Siemens / Schneider / ABB, switchgear make control panel along with PLC & all necessary cascade system automation, Power & Control MCB, MPCB, Over load \ Under load, SPP \ RPP, Dry run and all necessary pump & voltage protection, Indication lamp, Digital Pressure indicator cum controller . Danfoss make Pressure Transmitter & Pressure switch, Gauge, Pressure Tank (capacity as per pump design) etc. Skid for pump set with Hot dip Galvanized Suction & Delivery Header Plumbing Accessories along with Ball Valve, NRV, Y Strainer, Butterfly valve (RB / Zoloto make). MS Base frame with Hot dip. Polycab make power cable for pump set & Control cable float switch sensor, control cable for sensor etc complete as per direction of Engineer-in-charge.Vendor to submit performance curves and technical catalog of the proposed model for review & approval by electrical & PHE consultants. Panel diagram to be get approved from electrical consultant.Domestic Water OHT filling Pumping System Capacity per pump - 185 lpm @ Head of Pump - 64m Pump Qty - 2 (1working + 1 standby)
Supply, installation, testing and commissioning of Skid mounted Hydro-pneumatic Fixed speed system with Vertical in line pump set with Siemens / Schneider / ABB, switchgear make control panel along with PLC & all necessary cascade system automation, Power & Control MCB, MPCB, Over load \ Under load, SPP \ RPP, Dry run and all necessary pump & voltage protection, Indication lamp, Digital Pressure indicator cum controller . Danfoss make Pressure Transmitter & Pressure switch, Gauge, Pressure Tank (capacity as per pump design) etc. Skid for pump set with Hot dip Galvanized Suction & Delivery Header Plumbing Accessories along with Ball Valve, NRV, Y Strainer, Butterfly valve (RB / Zoloto make). MS Base frame with Hot dip. Polycab make power cable for pump set & Control cable float switch sensor, control cable for sensor etc complete as per direction of Engineer-in-charge.Vendor to submit performance curves and technical catalog of the proposed model for review & approval by electrical & PHE consultants. Panel diagram to be get approved from electrical consultant.Flushing Water OHT filling Pumping System Capacity per pump - 130 lpm @ Head of Pump - 67m Pump Qty - 2 (1working + 1 standby)
SUB WORK -3: Providing Data ,telephone & CCTV System for new adminsitrative building for Education Department (B2+B1+LG+G+8 Floor) at city serve no -832 ,Final Plot no 173, Bhamburda, Shivajinagar, Pune Data Netwroking System Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, with core dia 50/125 µm (OM4) suitable for 1 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC ( SERVER RACK 1,2,3,4,5,6,7)
Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH– 450x550x367 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 12U wall mount rack (Dimension- DxWxH – 450x550x635 mm) as per specification No. WG- NAS/RAK
Supplying, fixing, and configuring 48 ports managed gigabit switches layer-2 48 10/100/1000Base-T ports L2+ Management Switch with 4 10GE SFP+ ports complete.
Supplying, fixing, and configuring 8-ports 10/100/1000Mbps unmanaged gigabit PoE Switch complete.
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 20 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 10 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Telecummunication System Supplying & erecting telephone copper cable 2 pair with 0.5 mm dia. laid in provided PVC casing capping/ conduit as per specification No. WG-TW
Supplying & erecting jelly filled armoured telephone cable 20 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW
Supplying & erecting jelly filled armoured telephone copper cable 50 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW
Supplying & erecting jelly filled armoured telephone copper cable 100 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TWW
Supplying, erecting & commissioning MDF Box 50 x 50 pairs as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 60 x 60 pairs as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 100 x 100 pairs as per specification No. WG-TW
Supplying, erecting & commissioning junction box suitable for 20 pairs as per specification No. WG-TW
Supplying, erecting & commissioning junction box suitable for 30 pairs as per specification No. WG-TW
Supplying, erecting & commissioning junction box suitable for 50 pairs as per specification No. WG-TW
Supplying, erecting & commissioning junction box suitable for 60 pairs as per specification No. WG-TW
Supplying, erecting & commissioning junction box suitable for 100 pairs as per specification No. WG-TW
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID unit as per specification complete.
Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete.
Supplying & installing expansion cabinet for extension of digital hybrid EPABX to expand system by 32 ports with programming and configuration of extensions and direct lines with required accessories complete.& Note Add Rs. 17089/= for additional 8 extension card)
CCTV SYSTEM Supply Installation commissioning of 4 MP Full HD IP Dome /Bullet Camera Image Sensor 1/3" 4 megapixel progressivescan CMOS Effective Pixels 2304 (H) × 1296 (V) Electronic Shutter Speed Auto/Manual 1-1/100000 s Min. Illumination 0.5 lux F2.1 (Color); 0 lux (IR LEDs on IR Distance - nUp to 100 ft (30 m) Day/Night -auto (ICR)/Color/BW Backlight Compensation - BLC/HLC/DWDR White Balance - Auto/Manual Gain Control - Auto/Manual Noise Reduction - 3D Privacy Masking- Up to 4 areas Lens Focal Length- 2.8 -12 mm Horizontal Angle of View 92° 86°-28 Compression H.265 (Main/High/Baseline Profile) /MJPEG Resolution 3 MP (2304×1296) 1080p Main Stream 4 MP ,30 fps 16x Digital zoom 60 fps, Resolution- Verifocal lens, 320 db Corridor Mode Support Network Protocol IPv4/IPv6 HTTP HTTPS TCP/IP UDP UPnP ICMP IGMP RTSP RTP SMTP NTP DHCP DNS PPPoE DDNS FTP IP Filter QoS Compatibility -nONVIF Profile S CGI Max. User Access 20 users Mobile App - for iPhone iPad Android Phone and Tablet Power Supply PoE (802.3af) 12 V DC Working Environment -22°F to 140°F (-30°C to 60°C); 10% to 100% RH condensing Ingress Protection IP66 Vandal Resistance - IK10 Regulatory FCC Part 15B Class B (3 years warranty)
Supplying and erecting Supplying, erecting, testing & commissioning of NVR 64 Channel professional series 4K HD Network Video Server : Processor : Industrial embedded micro-processor Operating System : LINUX Two-way Talk : 1 channel Input, 1 channel Output, RCA Video Output : 1 HDMI, 1 VGA Video Resolution : 3840×2160, 1920×1080, 1280×1024, 1280×720, 1024×768 Channel : 64 channel Bandwidth Incoming : Max. 200Mbps Incoming and 96Mbps outgoing bandwidth Motion Detection : MD Zones: 396(22×18). Alarm Input : 16 Channel, Low Level Effective, Green Terminal Interface Alarm Output : 4 Channel, NO/NC Programmable, Green Terminal Interface Smart Phone : iPhone, iPad, Android PhoneHard Disk : 8 SATA III ports, up to 10TB Each Trigger Events : Recording, PTZ, Tour, Alarm out, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips Recording Mode : Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Tampering, Video Loss), Stop Search Mode : Time/Date, Alarm, MD & Exact search (accurate to second), Smart search Backup Mode : USB Device/Network Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup section,Digital zoom Max User Account : 128 users Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec Ethernet : 2 RJ-45 ports Interface Ports : 2 USB (1USB 3.0), 1 RS485, 1 RS232 ( 3 Years Warranty)
Supply and Installation of 8 TB (7200 RPM) Surveillance hard disk 8 TB storage capacity with SATA support 6GB/s NCQ 64 MB cache 3.5 inches
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 modules duly erected.
Supply,Installation,Testing & Commissioning of Allir one Computer For Factor - All-in-one Processor Type Core i5 Family Processor Spec 2.3 GHz Ram 8 GB Memory Technology DDR4 Computer Memory Type GDDR4 Hard Drive Size 1 TB Hard Disk Description HDD hard Drive Interface Serial ATA SSD 256 GE Additional Graphics Coprocessor Intel UHD Graphics 630 Graphics Chipsel Standing Screen display Size 21.5 Inches Connectivity Type Bluetooth Wireless Type Bluetooth 801.11ac. Hardware Platform Windows Operating System Windows 10 Professional Warranty - 3 years
Supplying, Erecting, Testing & Commissioning of Full HD commercial display DISPLAY-Screen Size 55-inch Aspect Ratio 16:9 Backlight Scanning 100Hz Resolution 1920 x 1080 pixels Viewing Angle178°/178° TERMINAL- VIDEO IN RCA X 1 AUDIO IN (L/R) RCA Pin Type X 2 HDMI IN HDMI 1.4 X 3 USB Input USB 2.0 X 2 RS232C Yes HDMI CEC Yes VGA IN Yes PC AUDIO IN Yes (1) (Share with AC)
Supplying, fixing, and configuring 8-ports 10/100/1000Mbps unmanaged gigabit PoE Switch complete..
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & installing UTP networking cat-6 cable with rodent proof jacket suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying, Installation, Testing & Commissioning of Professional Quality Imported Power Amplifier 480 W with Built in Temperature controlled Fan,Overload Protection, Short circuit Protection. Voltage 24 VDC +15% / -15%, Current max 30 A, Performance, Output power (rms/maximum) 480 W / 720 W, Power reduction on backup power -1 dB, Frequency response 50 Hz to 20 kHz (+1/3dB @ 10 dB, ref. rated output) Distortion <1% @ rated output - power, 1 kHz, S/N (flat at max volume) >90 dB (2 Working + 1 Std. By),
Supplying, erecting, testing and commissioning microphone complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning stand for microphone complete.
PA SYSTEM FOR CONFERENCE ROOMS Supplying Installation Testing & Commissioning of Chairman Unit,Priority button for chairman microphone, Microphone on/off button, two headphone sockets, Acoustic input at the microphone- 85 dB SPL, frequency Response- 400Hz to 10KHz length of the microphone with flexible stem of 488 mm in length and operating tempreture -5 °C to + 45 °C
Supplying, Installing, Testing & Commissioning of DCN Multi core extension cable for Conference Technical specifications Mechanical Dimensions (dia.) 6 mm (0.24 in), Material PVC Color Grey.
Supplying, erecting, testing and commissioning amplifier 120 W for public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying Installation Testing & Commissioning of Delegate Unit Microphone on/off button, Two headphone sockets, Acoustic Input at the microphone- 85dB SPL, Frequency Response- 400Hz to 10Khz , Length of the microphone from the base of the stem- 488mm, Operating temperature: -5 rC to +45 rC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete
VIDEO CONFERNCING Supply Installation and commissioning of Full High Definition Video Conference System, Simultaneous Connection Sites-4 with add on cloud based VC connectivity : Communication Method -SIP, H.323, Video Compression Method- H.261 (mainstream only), H.263, H263+, H.263++ (reception only), H.264 High Profile, H.264 Baseline Profile, Remote Camera Control- H.224, H.281 (Zoom/Pan/Tilt/Preset), Dual Stream Method- H.239 (H.323), BFCP (SIP), Multi-Monitor- 2 displays, Encryption- SRTP (AES 128 bit), H.235 (AES 128 bit), Communication Bandwidth- 256 kbps to 18 Mbps, Compatible Resolutions- min: 176 x 144p, max : 1920 x 1080p, Screen Display- Full-screen, Picture in Picture, Picture with Picture, Side by Side, Audio - Echo canceller, Auto gain control, Stationary noise reduction, Lip synch, Equalizer, Mic mute, I/O Terminals Video Input: Camera - HDMI main x 1, HDMI sub x 1 (Input resolution: 1280 x 720p, 1920 x 1080i, 1920 x 1080p), PC- RGB x 1 (Mini D-sub 15pin), HDMI x 1, Video Output -HDMI x 2, Audio Input- Boundary Omnidirectional Microphone (Digital Interface Type) x 1, Boundary Omnidirectional Microphone (Analogue Interface Type) x 1, HDMI, Stereo mini-plug*4 x 1 (ø3.5 mm), RCA (Stereo) x 1, Audio Output- HDMI*5, Stereo mini-plug*4 x 1 (ø3.5 mm), RCA x 1 (Stereo), Network- RJ45 x 1 1000BASE-T/100BASE-TX/10BASE-T Full Duplex, External Control- RS-232C x 1, USB 2.0 x 1, Camera Control Terminal x 1, No. of Simultaneous Connection Sites-4 - Unauthorized Incoming Call Security- Identification Number / Terminal Verification (HDVC, HDVC Mobile) / Whitelist, Content Sharing- PC (RGB/HDMI), Sub video camera (HDMI sub), Network Functions- Packet resending (ARQ), Forward Error Correction (FEC), Adaptive Rate Control (ARC), Reorder, Packet Shaping, Arbitrary Port Setting, NAT Compatibility, Encryption, IP Precedence/DiffServ Support, External Control- Control via web browser/HTTP CGI, TELNET, RS-232C, Connection Modes- IP mode, NAT Traversal Service, IP/NAT Traversal Service, Pan Tilt Zoom ,12x Optical Zoom HD Boundary Microphone :- Maximum Pickup Range- Approx. 4 m (radius), Pickup Method- Stereo / Monaural ,Microphone Unit-Unidirectional ECM, microphone parts x 4, Number of Connections- Maximum 4 microphones, Maximum Input Sound Pressure- 110 dBspl, Number of Terminals for Microphone Connection-2, Cable Length- Approx. 8.5 m , Operating Temperature- 0 °C to 40 °C, Operating Humidity- 10 % to 90 % (non-condensing) HD Communication Camera :- Effective Pixels- 1920 x 1080p, Pan / Tilt Pan: ±130°, Tilt: +90°-25° , Zoom (optical/digital)- 12x / 10x, Angle of view Horizontal angle of view- 72.5 º (Wide end) - 6.3º (Tele end), Vertical angle of view- 44.9º (Wide end) - 3.8º (Tele end) F1.8 (Wide end) - F2.8 (Tele end), Presets- 12 positions, Connection Cable- HDMI , Operating Temperature- 0 °C to 40 °C, Operating Humidity- 20 % to 90 % (non-condensing)
Supply and installation of Video Conferencing Cart with caster wheels- top shelf for mounting video conferencing camera and a shelf to keep the conferencing codec unit. made with a heavy duty steel and a shelf for added storage capacity. TV Stand to accommodates screens
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 25 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 20 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 5 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying & installing Audio Video cable low voltage grade as per specification having 15mtr cord length with required connectors 3RCA X 3RCA CABLE complete.
Supplying & erecting HDMI extender over RJ45 Ethernet Cable Cat5e/6/7 60M 200ft complete..
Supplying Installation Testing & Commissioning of 16 Channel Streo Mixer with phantom power mic inputs 26 inputs as standard 16 mono channels with high quality UltraMic™ pre-amps 4 stereo returns 4-bus architecture with sub-group routable to mix Built-in Lexicon dual effects processor Direct outputs for multitask recording individually switchable for prepost- fade operation Inserts on all mono channels Inserts on stereo mix bus3-band British EQ with swept mid-band Stereo 18dB/octave 100Hz highpass filter to cut stage rumble +48V phantom power Channel Mute control 10-segment tri-colored metering Two sub-group outputs Separate mono sum output
RACEWAYS Supply & Installation of Junction boxes for direct acess to cables at the intersection of raceways. Supply completely with base and cover plate (Lid) with height adjustable feature from 65mm to 90 mm. Confirms to standard EN 60-670,EN 50 085 - 2 - 2 & IEC 61534-22. . For adjustable junction box, resistance to vertical load applied over a small surface area should be 500N & resistance to vertical load applied over a large surface area should be 2000N. Use junction box with fly over for direct acess to cables at the intersection of floor raceways while maintaining perfect separation and 90 degree cross overs between data and power cables. 225mm X 225 mm X 65-90mm Junction Box
Supply & Installaion of GI raceways made of pre-galvanished sheet with thickness of 1.5mm for distributing LV and ELV cabling in screed floors installations. Can be combined with junction boxes, backboxes (floorboxes) for wiring devices, fixing and coupler accessories. Consist of body & cover. Cover fitted on to the body with screws & can be opened easily if required. Particularly suitable for applications requiring EMC screening. Protection level should be IP 20 & IK 08. Standard length should be 2.44 mtrs. Confirms to standard EN 60-670, EN 50 085 - 2 - 2 & IEC 61534-22.. Resistance to vertical load applied through small surface area should be 1500 N & Resistance to vertical load applied through large surface area should be 3000 N. Race ways should be supplied with complete accessories i.e. fixing brackets & couplers for joining raceways from the same manufacturer. 50 mm X 38mm GI/Metal Raceway- One Compartment
Supply of GI raceways made of pre-galvanished sheet with thickness of 1.5mm for distributing LV and ELV cabling in screed floors installations. Can be combined with junction boxes, backboxes (floorboxes) for wiring devices, fixing and coupler accessories. Consist of body & cover. Cover fitted on to the body with screws & can be opened easily if required. Particularly suitable for applications requiring EMC screening. Protection level should be IP 20 & IK 08. Standard length should be 2.44 mtrs. Confirms to standard EN 60-670, EN 50 085 - 2 - 2 & IEC 61534-22.. Resistance to vertical load applied through small surface area should be 1500 N & Resistance to vertical load applied through large surface area should be 3000 N. Race ways should be supplied with complete accessories i.e. fixing brackets & couplers for joining raceways from the same manufacturer.- 150 mm X 38mm GI/Metal Raceway- One Compartment
Supply & Installaion of 38mm pre-galvanised Raceway Connector for coonection of two raceways
Supply & Installaion 50 mm X 38mm pre-galvanised Fixing Brackets
Supply & Installaion 150 mm X 38mm pre-galvanised Fixing Brackets
Subwork No.4 : Fire Fighting System, Fire Alarm & P.A. System for New Adminsitrative Building for Education Department (B2+B1+LG+G+8 Floor) at city serve no -382 ,Final Plot no 173, Bhamburda, Shivajinagar, Pune - FIRE FIGHTING SYSTEM Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main multi stage pump, of 2800 LPM at 105 m Head centrifugal type, 120 HP, (90 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/MSC
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 105 m head 20 HP (15 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of booster pump of 450 LPM at 35 m head 7.5 HP (5.5 KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/BP
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Supplying and erecting D.O.L. Starter 400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P
Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF FFA/ARV
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting G.I. pipe above ground of „C‟ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of „C‟ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of „C‟ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of „C‟ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of „C‟ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of „C‟ class ERW of size 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Excavating hard Rock or bituminous road by chiselling for reparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete.
Excavating hard murum / metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
Supplying and erecting cast iron foot valve ball type/flap type of size 150 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and erecting 100 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 200 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting cast iron double flange sluice valve 75/80 mm dia. complete as per specification no. FF-VL/SV
Supplying and erecting cast iron double flange sluice valve 100 mm dia. complete as per specification no. FF-VL/SV
Supplying and erecting cast iron double flange sluice valve 150 mm dia. complete as per specification no. FF-VL/SV
Supplying and erecting cast iron double flange sluice valve 200 mm dia. complete as per specification no. FF-VL/SV
Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 200 mm dia. complete as per specification no. FF-VL/BFV
Supplying and erecting cast iron double flange ball type NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange ball type NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange ball type NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange ball type NRV of size 200 mm dia complete as per specification no. FF-VL/NRV
Supplying & erecting gun metal gate valve of 25mm dia size complete as per specification no. FF-VL/GV
Supplying & erecting gun metal gate valve of 50mm dia size complete as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying & erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FF- FA/FBC
Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting one no. brass orifice plate having 6 mm. thickness, 140 mm outer dia and required/proper diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying, erecting, testing and commissioning of 15 mm (½") dia.NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR
Supplying, erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 100 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes
Providing Round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Supplying and erecting D.C.P. type Fire Extinguisher 9 kg capacity cartridge type with Gun Metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985 and complete rected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878 /15683Complete erected with necessary clamp made from 50x6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 1 kg capacity with necessary clamp for erection on wall.
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP. 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism. 12/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling. coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads 2850 lpm at 83 m Head
Providing and fixing 150 mm dia installation valve with Hydraulic trim type automatic alarm to be connected with control valve drain and test valve as per manufacturer's recommendations . with accessories like water motor gong bell, Test & drain valve , Flow switch etc UL listed etc complete to satisfaction of Architect/ PM
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread withmaximum working pressure of 175 PSI test pressure of875 PSI (Burst) with branch line (Inlet) 25mm NPTmale thread to sprinkler head (Outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete asrequired. (1500 mm long)
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required
Providing, laying, testing & commissioning of 'C' class heavy duty 250 mm dia (wall thickness 6.3 mm) MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required
Supplying, fixing, testing and commissioning of 250 mm dia butterfly valve of PN 1.6 rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Providing, installation, testing and commissioning of 250 mm dia non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required :
Providing, installation, testing and commissioning of 15 mm dia quartzoid bub type sprinkler of rating 68 degree centigrade with requred accessoriss: upright Sprinkler
Providing, laying, testing & commissioning of 80mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge.
Providing, laying, testing & commissioning of 150mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge.
Providing and fixing 25 mm dia Inspection & Testing Assembly with 25mm gunmetal ball valve, gun metal sight glass bypass valve & connected to drain line etc complete as per drawing.
FIRE ALARM -Supply,Installation ,Testing and Commissioning of wall mounting ,8 loop microprocessor based analog addressable fire alarm control panel expandable by minimum 2 additional loops with minimum 80 character LCD display 4 access level 1000 events, historical logging , flash E-PROM , 240 volts AC power Supply, Automatiac battery charger ,240V SLA batteries suitable for operating the entire system incluiding tack back units and he hooters/strobes for a minimum of 4 hours in battery condition shall have suitable power amplifires for hooter / Strobes the panel shall be capable beeing integrated with the BMS system and Shall include cost of supply,installation of any additional modulesof interface required for the same. the panel Shall be completed as perUL and FM/EN54 & VDS standards and as required fixing of 6 loop microprocessor based fire alaram control panel with Zonal indication and battery back up as per . detailed specification
SITC of microprocessor based LCD Repeater panel with Min 168 LCD charater & capable of Features like of acknowledging / silencing of alarams complete PSU ( min 168 LCD character
Supply and insallation of intallegent analogue addressables smoke detector including cost of base plate etc. complete as per specifcation with required fittings and accessories
Supply and insallation of intallegent analogue addressables smoke detector above false ceiling with response indicator including cost of base plate etc. complete as per specifcation with required fittings and accessories
Supply and insallation of intallegent analogue addressables rate of rise cum fixcing temprature heat detector including the cost of ase plate 75mm Dia MS outlet box for fixcing the detector base, mounting accessories etc.complete as per secification
Supply ad insallation of intallegent analogue addressables analouge manual call point with resetable flexible elements to initiate alaram incluiding the cost of mounting accessories etc. complete
Supply and fixing od addressable Wall mounting Strobes cum hooter incluiding the cost of mounting accssories complete as per specification and as required including testing nad commissoning
Supply , installation and testing & Commissioning of approved intelligent Addressable Fault isolatorModules.
Supply, installing, Testing & Commissioning of Addressable Control modules for Sounders / Strobes / Sounder cum Strobes. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device. The control module shall have operating temperature range from 0°C to 49°C. The module shall have Electronic addressing. The module shall have Electronic addressing and shall be supplied with mounting plate from OEM for ease of installation & maintenance.
Supply,insatalling,Testing & Commissioning of Addressable Control Relay modules for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs.. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The control module shall have operating temperature range from 0°C to 49°C. The module shall have Electronic addressing and shall be supplied with mounting plate from OEM for ease of installation & maintenance.
Supply,insatalling,Testing & Commissioning of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The Monitor Module shall have operating temperature range from 0°C to 70°C. The module shall have Electronic addressing. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU Note:- 1. For item no 13-8-8 to 13-8-11 increase overall rate by 7.5% for FRLS.
PA System Supplying, Installation, Testing and Commissioning of 19" Rack Mountable 12 Zones Switcher Console With 8 I/O , . This Unit Can Play, Stop And Play Again Announcement Automatically Across The Each Zone According To The Program Settings For Systematic Evacuation Capable Of Connecting Booster Amplifier. (With All Required Accessories, Equipment’s Required For Connection & Smooth Functioning Of The System Whether It Is Mentioned Or Not) along with suitable call station for 12 zone
Supplying, Installation, Testing and Commissioning of 240 W, total output power at 70.7 Vrms Amplifier with The amplifiers shall be placed in the field on different designated floors with all accessories like cabinet etc required to complete the installation.
Supply, insatalling, Testing & Commissioning of 4W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling Mount Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms.
Supplying, installing, testing of 2c x 40/0.2 mm twin twisted cables multi- standerd shielded insulated straight FRLS armoured cable ( for 12 w speaker ,booster amplifier to centeral mixer amplifier and call center )
TELEPHONE TALK BACK SYSTEM - Supply,insatalling,Testing & Commissioning of Fire Fighter's Telephone Panel for two way communication between Remote Fire Fighter & Fire Command Center. UL Listed as per Below spacification Primary power : 220VAC - Secondary power : 24VDC - Max no of Zones : 8 - Operating Temperature : 0 – 49° C / 32-120° F. - Relative Humidity : 93 ± 2% RH (non-condensing)at 32 ±2° C / 90 ±3° F
Supply,insatalling,Testing & Commissioning of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center.
Supply,insatalling,Testing & Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center
Sub work 5 : Providing solar System for new adminsitrative building for Education Department (B2+B1+LG+G+8 Floor) at city serve no -832 ,Final Plot no 173, Bhamburda, Shivajinagar, Pune SOLAR SYSTEM Supplying, installing, testing and commissioning of 101 kWp capacity on grid solar power pack with GI mounting structure and inter connecting wires / cables without battery bank SPV modules and solar power conditioning unit of required capacity complete, with 5 years on site performance warrantee. Specification no. ESD-RT-ONG
Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
Subwork No.6: Providing 4 nos of 10 passanger Lift for new adminsitrative building for Education Department (B2+B1+LG+G+8 Floor) at city serve no -382 ,Final Plot no 173, Bhamburda, Shivajinagar, Pune SITC of Electric Traction Passenger Lift with Rated capacity :- 10 Passenger/680Kg Floors :- B1+B2+LG+G+8 floor (12 Stops/12 Landings) Travel :- 3 to 45 mtrs Location of Lift Machine:-MRL Rated speed :- 1.5mps VS Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/framesLift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc.COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor Clear Car size of 1300 mm wide x 1350 mm deep x 2200 mm highLOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/ control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class ARD complete with necessary SMF VRLA batteries Fireman controller having fireman switch at fire Landing, CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of 2000 mm wide x 2000mm deep. 1500 mm Pit depth, 4200 mm Overhead.NOTES: 1)General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2)Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.A1-2 : For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete C2 -For Lift travelling above Sixth floor & up to Fifteenth floor
SITC of Electric Traction Passenger Lift with Rated capacity :- 10 Passenger/680Kg Floors :- LG+G+8 floor (10Stops/10 Landings) Travel :- 3 to 37 mtrs Location of Lift Machine:- MRL Rated speed :- 1.5mps VS Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/framesLift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc.COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor Clear Car size of 1300 mm wide x 1350 mm deep x 2200 mm highLOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/ control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class ARD complete with necessary SMF VRLA batteries Fireman controller having fireman switch at fire Landing, CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of 2000 mm wide x 2000mm deep. 1500 mm Pit depth, 4200 mm Overhead.NOTES: 1)General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2)Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.A1-2 : For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete C2 -For Lift travelling above Sixth floor & up to Fifteenth floor
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB
Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB
Supplying & fixing CRCA sheet Box with earthing terminals for housing 2 Pole RCCB on iron frame/laminated board complete.
Supplying & fixing CRCA sheet Box with earthing terminals for housing 4 Pole RCCB on iron frame/laminated board complete.
Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 modules duly erected.
Supplying and erecting bulkhead fitting suitable for upto LED upto 12W fixed on wall. As per specification no. FG-IDF/BHF
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws in an approved manner. [density 0.11kg/mtr .'. 60m x 0.11=6.6]
Subwork No. 7 : Providing HVACSystem for (B2+B1+LG+G+8 Floors) New Administration Building for Education Department at City Survey No. 383, Final plot No. 173, Bhamburda, Shivajinagar, Pune. Air Conditiong and Ventilation System - Supply Installation Testing and Commissioning of double skin single-decker Air Handling Unit (AHU) following specification : - Construction : - Sheet metal sectionized cabinet type AHU fabricated from Al extruded section frame structure. Inner Skin:0.7 mm plain galvanized sheet. Outer Skin: 0.7 mm Precoated galvanized steel sheet. Panel: 50mm thick PUF insulation having 38±2kg/m3 density. Profiles: Thermal break profile. Internal/Outer Sheet: GI with internal coving, Coving shall be an integral part of AHU. - AHU Sections:- Mixing chamber with return air damper and fresh air damper. Pre-filter section with G4 filter in an aluminum construction. Filter shall be as per EN 779 Standard. Coil Section with DX coil., and with Differential pressure transmitter and Canvass connection att outlet Sandwich type SS 304 drain pan shall be provided. Drain pan shall be with suitable slope to avoid water stagnation and insulated with Nitrile rubber of suitable thickness to avoid condensation. Supply air blower section: Direct driven Plug fan and High Energy Efficient motor ( EFF1/IE2). Motor RPM shall be 1440 / 2880. AHU -01 -22000CFM @ 80mm Static 41 TR Motor -15 kW
Supply Installation Testing and Commissioning of double skin single-decker Air Handling Unit (AHU) following specification : - Construction : - Sheet metal sectionized cabinet type AHU fabricated from Al extruded section frame structure. Inner Skin:0.7 mm plain galvanized sheet. Outer Skin: 0.7 mm Precoated galvanized steel sheet. Panel: 50mm thick PUF insulation having 38±2kg/m3 density. Profiles: Thermal break profile. Internal/Outer Sheet: GI with internal coving, Coving shall be an integral part of AHU. - AHU Sections:- Mixing chamber with return air damper and fresh air damper. Pre-filter section with G4 filter in an aluminum construction. Filter shall be as per EN 779 Standard. Coil Section with DX coil., and with Differential pressure transmitter and Canvass connection att outlet- Sandwich type SS 304 drain pan shall be provided. Drain pan shall be with suitable slope to avoid water stagnation and insulated with Nitrile rubber of suitable thickness to avoid condensation. Supply air blower section: Direct driven Plug fan and High Energy Efficient motor ( EFF1/IE2). Motor RPM shall be 1440 / 2880. AHU -02 -13500 CFM @ 80mm Static 22 TR Motor -10 kW
SITC of Electronic Expansion Valve Kit as per OEM standard to connect AHU with VRF ODU. Expansion Valve should also have thermostat included and complete with all necessary accessories to install complete. AHU - 01 - 3 Nos. and AHU-02 - 2Nos.
Supply, installation, testing and comissiong of starter panel (IP 54 Rating) with DOL/Star Delta/VFD starter of required capacity incoming switch gear (MPCB), overload relay , control accessories like Elmex connectors, ferrules etc. with ON/OFF push button & indicating lamps (ON/OFF/TRIP), facility of control wiring for remote operation. Also potential free contacts to be provided for BMS. The panels to be designed considering 'Type 2' coordination. AHU -01 - 15kW
Supply, installation, testing and comissiong of starter panel (IP 54 Rating) with DOL/Star Delta/VFD starter of required capacity incoming switch gear (MPCB), overload relay , control accessories like Elmex connectors, ferrules etc. with ON/OFF push button & indicating lamps (ON/OFF/TRIP), facility of control wiring for remote operation. Also potential free contacts to be provided for BMS. The panels to be designed considering 'Type 2' coordination. - AHU -02 - 10 kW
VRV / VRF Outdoor Condensing Units- Supplying, erecting, testing and commissioning of 6 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 10 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 12 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 14 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 18 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 20 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 22 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 24 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 26 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
VRF INDOOR UNITS - Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.4TR ( 512 cfm ) to 2.0TR ( 618 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.1TR ( 671 cfm ) to 2.7TR ( 918 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.0TR ( 441 cfm ) / 1.3TR ( 512 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.5TR ( 512 cfm ) / 1.8TR ( 618 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.0TR ( 618 cfm ) / 2.3TR ( 671 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.6TR ( 918 cfm ) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 3.0TR ( 1100 cfm ) to 3.2TR ( 1165 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 3.3TR ( 1165 cfm ) to 4.0TR ( 1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to 2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Refrigerant Piping: - Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/25A complete as per specification no. SW-RCCB/RCCB
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 63A complete as per specification no. SW-RCCB/RCCB
Supplying & fixing CRCA sheet Box with earthing terminals for housing 4 Pole RCCB on iron frame/laminated board complete
Supply Installation Testing and Commissioning of Cordless Center Remote Controller (Suitable for Indoor unit operations)
Supply Installation Testing and Commissining of Central remote controller - (suitable to connect up to multiple AHU and outdoor units) including integration with a fire alarm system, operate or monitor on / off, temperature setting, etc., individually. Note Central Remote controller to be BMS compatible with necessary accessories and software
SITC of Drain Piping shall be Hard PVC 25mm dia for single unit, 50mm, 40mm dia for two or more units. Drain Piping shall be insulated 12mm Nitrile rubber- 25mm Dia
SITC of Drain Piping shall be Hard PVC 25mm dia for single unit, 50mm, 40mm dia for two or more units. Drain Piping shall be insulated 12mm Nitrile rubber- 50mm Dia
INLINE FAN: - SITC of Inline fans for Fresh air shall be complete with speed control, louver shutter, starter panel, rain protection louver, bird screen. Fans to be ring mounted on suitable frame provided by AC Contractor. Power will be provided 5 ft away from the fan and necessary wiring with a plug will be provided by AC contractor. Starter panel shall be BMS compatible.Fresh Air Fans with G2 filter 400 CFM to 790 CFM @ 15mm static
SITC of Inline fans for Fresh air shall be complete with speed control, louver shutter, starter panel, rain protection louver, bird screen. Fans to be ring mounted on suitable frame provided by AC Contractor. Power will be provided 5 ft away from the fan and necessary wiring with a plug will be provided by AC contractor. Starter panel shall be BMS compatible.Fresh Air Fans with G2 filter 900 CFM to 1200 CFM @15mm static
SITC of Inline fans for Exhaust air shall be complete with speed control, louver shutter, starter panel, rain protection louver, bird screen. Fans to be ring mounted on suitable frame provided by AC Contractor. Power will be provided 5 ft away from the fan and necessary wiring with a plug will be provided by AC contractor. Starter panel shall be BMS compatible.1150 CFM @15mm static
SITC of Inline fans for Exhaust air shall be complete with speed control, louver shutter, starter panel, rain protection louver, bird screen. Fans to be ring mounted on suitable frame provided by AC Contractor. Power will be provided 5 ft away from the fan and necessary wiring with a plug will be provided by AC contractor. Starter panel shall be BMS compatible.400 CFM @15mm static
Supplying and erecting fresh air cum exhaust fan of light duty 250V duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body
SITC of factory fabricated box type GI ducting complete with splitter dampers, turning vanes, access doors, supports etc. as per drawings and specifications. Ducts shall be made of either galvanized steel sheets or aluminium sheets. The galvanized steel sheet shall conform IS: 277 – 1975. Aluminium shall be of grade SIC of B-3 as specified in IS: 177 – 1974. - 24 Gauge GI Ducting
SITC of factory fabricated box type GI ducting complete with splitter dampers, turning vanes, access doors, supports etc. as per drawings and specifications. Ducts shall be made of either galvanized steel sheets or aluminium sheets. The galvanized steel sheet shall conform IS: 277 – 1975. as specified in IS: 177 – 1974. - 22 Gauge GI Ducting
SITC of factory fabricated box type GI ducting complete with splitter dampers, turning vanes, access doors, supports etc. as per drawings and specifications. Ducts shall be made of either galvanized steel sheets or aluminium sheets. The galvanized steel sheet shall conform IS: 277 – 1975. as specified in IS: 177 – 1974. - 20 Gauge GI Ducting
SITC of factory fabricated box type GI ducting complete with splitter dampers, turning vanes, access doors, supports etc. as per drawings and specifications. Ducts shall be made of either galvanized steel sheets or aluminium sheets. The galvanized steel sheet shall conform IS: 277 – 1975. as specified in IS: 177 – 1974. - 18 Gauge GI Ducting
SITC of Extruded Aluminium Powder coated Jet Nozzel with coller damper suitable for longer throw of air more than 4m- 400mm Dia
SITC of Extruded Aluminium Powder coated Square Diffuser Corners of inner and outer cores shall be assembled to provide precise mitered corners. Supply air diffusers shall be provided with butterfly dampers and plenums. Damper flaps shall be provided with a nylon worm gear assembly to enable ease in operation. Diffusers will be powder coated with coller damper
SITC of Extruded Aluminium Double louvered Double Deflection Powder coated Grill with Coller Damper
SITC of Extruded Aluminium Opposed blade Volume Control dampers in Duct
SITC of closed-cell class '0' elastomeric nitrile rubber insulation of suitable density (40 - 60 kg / m3) as per BS 476 Part 1 applied with adhesive. The insulation will be with factory-backed ribbed Aluminum foil. (19mm Thickness)
Providing and applying of accoustic insulation for air ducts with 25 mm thick, 48kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.
Supplying, installing, testing and commissioning of axial fans. Motors shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply with IP 55 protection, static pressure shall be as indicated. Each fan shall be with TEFC squirrel cage induction motors, all fan shall be with safety wire mesh (factory fitted) at inlet and outlet. Suitable spring isolators to provided along with the fans. Spring mount Isolater to have Efficiency of above 90%. Quoted price to include MS structural work required for mounting the fans as indicated in the drawing. All fans operating in fire mode only to have EFF2 motors, fans operating in normal mode to have EFF1 Motors.Dual Speed Fan CFM : 16500 CFM Normal Mode & 33000 CFM Fire Mode @ 15 mm WG - (Basement 1 - 2 Nos. & Basement 2 : 2 Nos. )
Supplying, installing, testing and commissioning of smoke spill fans. Fan, casing, motor, drive shall be suitable for smoke exhaust application & thermally rated for 250ºC for 2 hours as per [BS-7346 Part-2 : 1090] Class-B. Motors shall be High Temperature resistance smoke venting type suitable for 415+10% volts, 50 cycles , 3 phase AC supply with IP 55 protection, static pressure shall be as indicated. Each fan shall be with TEFC squirrel cage induction motors, all fan shall be with flexible fire proof connection at inlet and outlet. Suitable spring isolators to provided along with the fans. Spring mount Isolater to have Efficiency of above 90%. Quoted price to include MS structural work required for mounting the fans as indicated in the drawing. All Normal mode fans to have EFF1 motors Dual Speed Fan CFM : 16500 CFM Normal Mode & 33000 CFM Fire Mode @ 15 mm WG (Basement 1 : 2 Nos. & Basement 2 - 2 No).
SITC of Induced Air Axial Jet fans. Fan shall be AMCA certified for Air & Sound performance, balanced to vibration grade of G2.5 as per AMCA 204. Fan shall be complete with GSS casing ( 220 GSM ), Aluminium impeller, Motor Class H, special rated motor certified for 250 Deg C for 2 Hrs - 415/3P/50Hz. Inlet & outlet attenuators , inlet & outlet protection net. Complete assembly shall be certified for 250 Deg C for 2 Hrs. fire rating as per BS 7346 Part 2: 1990 Class B or EN 12101-3 & the copy of the Fire-test report has to be submitted for the approval.The Locationing of the jet fans has to be done in such a way that the Air velocity at any point on the plane of 1m from the ground level should not be less than 0.25m/s during the normal mode.Ø 400 MM 4500 CMH Normal mode 9000 CMH Fire Mod
SITC of CO Sensors of 700 Sqmtr Coverage Area. Sensors to be suitable to work in Hot conditions Sensors to send signal to PLC panels
SITC of the PLC Panels. The PLC panel shall operate the main Fresh air and exhaust fans (normal & fire mode) based on the signal from CO sensor. During a CO SENSOR signal for 30-90 ppm (i.e polution mode) the normal mode fans shall operate and at 100 ppm and above and smoke mode (i.e fire mode) or during emergency the fire mode exhaust fans shall operate along with the normal mode fans. Otherwise the entire system i.e jet fans,normal mode fans shall run on a timer based system (say 5min per hour) in order to remove the stale air, the setting should be adjustable by the operator at site. The PLC panel should have the provision of hooking up the panel with the fire alarm / fire fighting panel in case of emergecny. The PLC panel should have the provision for monitoring the whole system through BMS. PLC Panels for Fresh air and Exhaust fans to include the starter panel for all the fans with DOL/Star Delta starter of required capacity for the respective ventilation zone, incoming switch gear, overload relay , control accessories like Elmex connectors, ferrules etc. with ON/OFF push button & indicating lamps (ON/OFF/TRIP), facility of control wiring for remote operation. Also potential free contacts to be provided for BMS. The panels to be designed considering 'Type 2' coordination. Fresh Air Fan (5.5 KW x 2 Nos) Exhaust Air Fan (5.5 KW x 2 Nos.) For each Basement
SITC of PLC Panels for Jet fans PLC Panel to include the starter panel for all the jet fans with DOL/Star Delta starter of required capacity for the respective ventilation zone, incoming switch gear, overload relay , control accessories like Elmex connectors, ferrules etc. with ON/OFF push button & indicating lamps (ON/OFF/TRIP), facility of control wiring for remote operation. Also potential free contacts to be provided for BMS. The panels to be designed considering 'Type 2' coordination. During a CO SENSOR signal for 30-90 ppm (i.e polution mode) the normal mode fans shall operate and at 100 ppm and above and smoke mode (i.e fire mode) or during emergency the fire mode exhaust fans shall operate along with the normal mode fans. Otherwise the entire system i.e jet fans,normal mode fans shall run on a timer based system (say 5min per hour) in order to remove the stale air, the setting should be adjustable by the operator at site. The PLC panel should have the provision of hooking up the panel with the fire alarm / fire fighting panel in case of emergecny. The PLC panel should have the provision for monitoring the whole system through BMS.Jet Fan (0.55 KW x 8 Nos.) Each Basement
SITC of Fire Dampers with Motorized actuators. In case of Fire the power supply to actuator will be cut off and damper to be shut
Supplying, erecting & terminating XLPE armoured cable copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU. 3C X 6 Sq.mm. XLPE, FRLS, Armoured Cable with Copper Conductor.
Supplying, erecting & terminating XLPE armoured cable copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU.3C X 4 Sq.mm. XLPE, FRLS, Armoured Cable with Copper Conductor.
Supplying, erecting & terminating XLPE armoured cable copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU.4C X 6 Sq.mm. XLPE, FRLS, Armoured Cable with Copper Conductor.
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supply, Installation, Testing & Commissioning of Cabling from PLC Panel to Jet Fan - 3 core X2.5 sqmm FRLS armoured copper cable with copper earthing wire on saddle. 1 run per jet fan.
Supplying, erecting & terminating XLPE armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Nyati Engineers And Consultants PVT Ltd
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid