| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.9 L+₹37,202 (10.5%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹3.9 L+₹37,295 (10.5%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹4.1 L+₹51,995 (14.7%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹4.6 L
Closing Date
22 Feb 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
EandM Division, APWD, Prothrapur, Port Blair
Commissioning of Community Radio Station at BRAIT SW Providing IEI
2021_APWD_2326_1
NIT No. 70/EE/EandM/20-21
Open Tender
Electrical Works
Item Rate
30 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
1 Apr 2021
11 Feb 2021
23 Feb 2021
11 Feb 2021
22 Feb 2021
16 Feb 2021
12 Feb 2021 - 15 Feb 2021
75 days
Amount
1. WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required a) Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing suitable size Plastic Surface box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required a) 5/6 A switch
b) 3 pin 5/6 A socket outlet
Supplying and fixing suitable size Plastic Surface box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
2. MCB & DB Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 4 way (4 + 12), Double Door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 12 way , Double Door
Supplying and fixing 4 way MCB sheet steel Enclosure, phosphatised, powder painted with Din rail for mounting MCBs (but without MCBs and incomer) as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole
b) Single pole and neutral
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 40 A
3. Fitting & Fixtures Supplying and fixing of square type recessed mounted panel Trim LED Panel Square 15W LED 6000K/ 3000K similar to Havells Ordering code LHEBLEP7IN1W015/ LHEBLEP5IN1W015 or its equivalent to ISI standard complete with all accessories including connections etc. as required in false ceiling.
Supplying of A.C ceiling Fan (1200 mm) sweep (Colour: White) ISI marked 1 star rated (As per 2019 BEE Star Rating) without regulator i/c down rod of standard length 30 cm with all accessories similar to Bajaj Energy Smart 50 or its equivalent.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying of Spike guard 10A, 240V, 4 Socket with individual switch, Cable Length - 1.5 mtr similar to Anchor Code 22053 or its equivalent.
4. Earthing Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Providing and fixing 6 sq mm. FRLS PVC insulated copper conductor, single core on surface or in recess for loop earthing as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required a) 25 mm
5. UG Cable Supplying of following sizes of XLPE insulated Heavy duty armoured Aluminium conductor UG Cable of 1.1 KV grade conforming to IS:7098 (Part-I) and IS No. 1554 (Part-I) 1988 as applicable Make: CCI/Gloster/Havells/ Polycab/ Finolex etc., as required. a) 16 Sqmm x 4 Core
Supplying and Laying of One Number DWC HDPE Pipe having corrugation on the outer wall and plain surface on the inner wall along with all accessories like socket, bend, couplers etc. confirming to IS: 14930 Part -II directly on the surface or wall, etc. with suitable size clamp as required. a) 50mm outer and 38 mm inner dia Nominal size
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required a) 4 X 16 sq. mm (28mm
6. Air Conditioner Supplying, Installation, Testing and Commissioning of 1.5 Ton 5 Star (As per 2018 BEE star rating) High Wall Inverter Split Air Conditioner (Single Compressor 1 Phase 220 Volt) make:- VOLTAS model no. 185VJZJ or equivalent with minimum cooling capacity 5200W on top floor of 4 storeyed building. (Condenser Coil must be of copper materials) i/c cutting, drilling holes on the wall for passing gas pipes, fixing extra length of Copper connecting pipes, connecting cable and suitable size PVC Pipe on the Wall through the holes and Cementing, Painting to give an even look and smooth finish, wrapping PVC non adhesive white tape over insulation of gas pipe, etc., as required and as per the direction of E-in-C or its Equivalent.
Supplying, Installation, Testing and Commissioning of 1.0 Ton 5 Star (As per 2018 BEE star rating) High Wall Inverter Split Air Conditioner (Single Compressor 1 Phase 220 Volt) make:- VOLTAS model no. 125VDZX or equivalent with minimum cooling capacity 3600W on top floor of 4 storeyed building. (Condenser Coil must be of copper materials) i/c cutting, drilling holes on the wall for passing gas pipes, fixing extra length of Copper connecting pipes, connecting cable and suitable size PVC Pipe on the Wall through the holes and Cementing, Painting to give an even look and smooth finish, wrapping PVC non adhesive white tape over insulation of gas pipe etc., as required and as per the direction of E-in-C or its Equivalent.
Supplying and installation of Voltage stabilizer 4KVA, 170-270V operation,12A suitable for 1.0/ 1.5 ton Air Conditioner similar to V-Guard Model -VG 400 or its equivalent as required.
Fabrication and mounting of Stand made of MS angle of size 1.0 mtr x 0.4 mtr using 40 x 40 mm angle and UV stabilised 2 mm thick corrugated FRP sheet sloping roof, with stand legs embedded in PCC work/ wall surface, painted with one coat of Primer and 2 Coat of finishing water proof Paint, etc. for keeping outdoor unit of 1.0/ 1.5 Ton capacity Spilt type Air Conditioner, on top of 4 storeyed building as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
7. Electric Panel Supplying, Installation, Testing and Commissioning of Outdoor type floor mounted Sub Feeder pillar of size 0.50 mtr x 0.50 mtr x 0.30 mtr - 3 Phase 440 V with sloping roof and hinged door on front and rear side along with locking arrangement made of 2 mm thick CRCA sheet, MS Angle, MS Flat, etc. i/c supplying and fixing of following items i/c interconnection with suitable rating copper conductor cable. The panel should have inner earthing stud, one coat of Primer and 2 Coat of finishing water proof Paint, fixing of danger plate and should be grouted in PCC work on its four legs etc. as required. a) MCCB 63A Four Pole- 35 KA Breaking Capacity - 01 No., b) Rewirable Porcelain fuse unit with neutral link 63A (RYBN) - 01 Set., i/c Inter Connection of fuse and MCCB with suitable rating conductor cable c) Charging of this panel by laying of incoming UG Cable from nearby Feeder panel bus bar to porcelain fuse unit with necessary end termination using Aluminium lugs, nut bolt, etc as required.
M K ENGINEERING
M/s Sameer Decorative Corner
M/s Sai Electrical Works
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .